Search NASA⌕ Search

SEARCH · Search NASA

Results for “certification testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Certification testing of production superconducting quarter-wave and half-wave resonators for $\mathrm{FRIB}$

We report the Facility for Rare Isotope Beams (FRIB) is designed to accelerate ion beams to 200 MeV per nucleon with 46 superconducting radio-frequency cryomodules. The FRIB driver linac uses quarter-wave resonators and half-wave resonators; with a total of 324 resonators, the linac is currently the largest heavy ion accelerator in the world. Production of jacketed resonators began in January 2014 and was completed in December 2019. Dewar certification testing of all the cavities was done before they were installed into cryomodules. The experience and lessons from more than 5 years of FRIB resonator production and certification testing are analyzed and summarized in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On-Road Heavy-Duty Low-NOx Technology Cost Study

The National Renewable Energy Laboratory (NREL) conducted a cost analysis for emission control technologies under contract to the California Air Resources Board (CARB). CARB sought incremental cost analysis for emission control technologies for on-road heavy-duty (HD) engines, used in vehicle greater than 14,000 pounds (lbs) gross vehicle weight rating (GVWR) to achieve oxides of nitrogen (NOx) emissions rates significantly lower than those required by current emissions standards. Specifically, incremental costs (without any retail price mark-up) were estimated for representative diesel, natural gas, and gasoline engine and emission aftertreatment systems that were selected to represent potential technology packages that could achieve 0.02 grams per brake horsepower hour (g/bhp-hr) NOx on certification test cycles, including a proposed updated certification test cycle that includes additional low load operating conditions. NREL surveyed stakeholders including industry association groups, Tier 1 suppliers, and engine original equipment manufacturers (OEMs) to estimate incremental direct and indirect costs. Incremental costs were considered for current engine full useful life (FUL) definitions, as well as with proposed increased FUL and warranty period. The incremental costs were subsequently incorporated in life-cycle cost analyses examining the incremental engine and aftertreatment costs along with life-cycle costs over the various engine FUL scenarios. Life-cycle costs analysis included the incremental upfront cost, fuel consumption changes (changes in fuel economy), diesel exhaust fluid (DEF) consumption changes, and the maximum FUL of the aftertreatment package (major overhaul intervals).

33 ADVANCED PROPULSION SYSTEMS↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validating the Test Procedures Described in UL 1741 SA and IEEE P1547.1: Preprint

This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of key the components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1. This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of key the components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1.

14 SOLAR ENERGY↗

Consumer-Oriented Energy Use and Range Metrics for Battery Electric Vehicles

The present study was motivated by a need to expand information for consumers offered through the FuelEconomy.Gov website. To that end, a power-based modeling approach has been used to examine the effect of steady-speed driving on estimated range for model year 2020 – 2023 battery electric vehicles (BEVs). This approach allowed rapid study of a broader range of BEV models than could be accomplished through vehicle tests. Publicly accessible certification test results and other data were used to perform a regression between cycle-average tractive power requirements and the resulting electrical power. Importantly, this regression enabled estimation of electric power and energy use over a range of steady highway speeds. These analyses in turn allowed projection of vehicle range at differing speeds. The projections agree within 6% with available 65 MPH manufacturer test data. Analyses of vehicles from model years 2020 – 2023 show that the 5-cycle range and energy use values from the window stickers of new vehicles are reasonable values for steady-speed driving at 65 MPH. Range decreases by a median value of approximately 15% for each 10 MPH increase in speed. The 5-cycle energy use (in kW-Hr / 100 miles) and energy economy (in miles / kW-Hr) derived from the 5-cycle energy use are reasonable estimates for 65 MPH steady speed driving. Energy economy decreases by about 0.5 miles / kW-Hr for every 10 MPH increase in speed.

33 ADVANCED PROPULSION SYSTEMS↗

Southwest Wind Power R&D Test Site Development at the National Wind Technology Center (CRADA CRD-12-00472 Final Report)

Southwest Windpower, Inc. (SWWP) has been designing and distributing small wind turbines for more than 22 years and is the recognized global leader in the design, manufacturing and distribution of small wind systems (400-3000 watts). The company has been a pioneer in the development of wind technology and has built and shipped more than 170,000 wind turbines to over 120 countries worldwide. Headquartered in Flagstaff AZ, SWWP has sales representatives in over 88 countries. Applications for SWWP systems include residential homes, commercial properties, micro grids, remote cabins, telecom transmitters, offshore platforms, water pumping and sailboats. In addition, U.S. Department of Defense uses SWWP’s products in Forward Operating Bases (FOB’s), USGS uses them for remote monitoring of glacier movements and the CIA uses them to provide power seismic monitoring. Today, SWWP plans development of new technologies to address distributed energy market needs and become even more aggressive in international markets. This strategy includes extensive Research, Development, Demonstration & Deployment (RDD&D) activities to improve existing production line into more simple, reliable, and cost-effective wind turbine systems. Important part of such activities is the field testing of the new systems, which should provide: (i) validation of the reliable operation of hardware and software; (ii) validation of numerical models of the system and its components; (iii) field comparison of various control and optimization strategies; (iv) customized reliability testing; (v) customized monitoring and analysis testing; and (vi) IEC certification testing (vii) filed demonstration of system performance and reliability. Such field testing facility should encompass multiple towers and appropriate data acquisition systems. SWWP is exploring to move part of the engineering department to Colorado, and execute its RDD&D strategies in this new location. Partnership with NREL will provide great insights into SWWP’s RDD&D processes and more efficient commercialization by utilizing NWTC as the field testing site, and working close with NREL personnel. NWTC is ideally suited to strain the design. NREL is very experienced with customized and IEC testing. During this project, Southwest Windpower aims to improve the value proposition of distributed renewable energy, and make it a competitive choice in the energy markets. As of today, more then 170,000 small wind turbines, manufactured in the U.S., are installed in more then 180 countries. With the improved value proposition, Southwest Windpower wants to create and address new market needs, substantially increase its sales domestically and internationally, which should have positive impact on the creation of American jobs, competitiveness of U.S. economy, export or U.S. products, and the use of renewable energy.

17 WIND ENERGY↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Validating the Test Procedures Described in UL 1741 SA and IEEE P1547.1

This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of the key components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1.

14 SOLAR ENERGY↗

Black carbon emissions from modern automated cordwood stoves for space heating

Wood burning stove design is improving as regulation become stricter for particulate matter emissions. Here, this study describes results of black carbon (BC) emissions from three modern automated wood stoves when tested in common failure modes using a test protocol that included cold-starts, high and low fuel loading densities, and use of overly large pieces of fuel. Emission sampling was performed using a dilution sampling system in tandem with an aethalometer to measure BC with high time resolution. Results show that the time-weighted average BC emission rates were 0.91, 4.30, and 1.74 g/h for the three stoves tested (A, B, and C respectively), the values, both higher and lower than the United States 2020 certification test emission limit of 2.5 g/h. The results demonstrate good performance overall, given the rigorous nature of the testing protocol used. The aethalometer data showed that the performance was relatively poor during cold-start, when the fuel was ignited and combusted without a coalbed, and when stoves failed to optimize air delivery due to specific loading and output conditions. During the cold-start test section, the average BC emission rate was seven times higher than the overall average for Stove A, 10 times above the average for Stove B, and two times above the average emission rate for Stove C. Calculations of the Average Angstrom Absorption Exponent (AAE) of the exhaust aerosol showed little correlation with BC concentration. The results show that automation results in a quantifiable reduction in particular BC emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of SLOWPOKE-2 HEU Irradiated Fuel Transportation from Canada to USA - 19123(2)

The SLOWPOKE-2 (Safe Low-Power Kritical Experiment) was designed by AECL (Atomic Energy of Canada Limited) in the late 1960's. The core consists of HEU (highly enriched uranium) fuel with an enrichment of 93%. The fuel cage typically has approximately 300 fuel pins assembled in a triangular pitch between the two plates. The fuel pins are made from uranium-aluminum alloy cladded with aluminum. The SLOWPOKE-2 reactor is rated at a nominal 20 kW. with varying neutron flux, maximum being 1 E12 n/cm{sup 2}/s. The mass of the fuel cage is 5.06 kg. The life of the core can be extended by adding layers of beryllium reflector. The transportation flask for the irradiated fuel is a Type B(U)F. The shipment classification is UN3328 Class 7. To date, 4 SLOWPOKE-2 reactors have been decommissioned. The fuel from all these reactors was transported to the U.S. The CNSC (Canadian Nuclear Safety Commission) joint Canada-United States guide for approval of Type B(U) and fissile material transportation packages (RD-364) satisfies the requirements stipulated in International Atomic energy Agency (IAEA) TS-R-1 1996 edition (revised) and is acceptable to the DOT (Department of Transportation) and NRC (Nuclear Regulatory Commission) for complying with U.S. code of federal regulations 10 CFR Part 71. The export license is issued by the CNSC. The transportation licence is issued by CNSC after approval from TC (Transport Canada) and also by DOT after approval from NRC. The final home of the HEU SLOWPOKE-2 irradiated fuel is in Savannah River Site of DOE (Department of Energy). The transportation licence requires that the Type B(U)F flask is structurally sound in case of a crash. The US DOT provides a CAC (Competent Authority Certificate) which describes the irradiated fuel specifications that can be transported in the designated flask. The U.S. DOT also requires a leak test certification in accordance with ANSI N14.5-2014 to verify a leakage rate not to exceed 1 E-7 std-cm{sup 3}/s. As most SLOWPOKE-2 facilities are not located on the existing approved routes for nuclear fuel transportation, a route survey needs to be performed and submitted to the NRC. The route survey report is assessed by the NRC and issues a route approval for the transportation of the fissile material. This technical paper will discuss the detailed processes required to obtain approvals in order to transport the HEU SLOWPOKE-2 irradiated fuel from Canada to U.S. based upon recent experiences of decommissioning SLOWPOKE-2 reactors in Canada. It will provide details on the requirements of various regulators in Canada and the U.S. that govern and regulate this shipment including transportation, safety and security. It will also present lessons learned from previous experiences that can be utilized for best practice on other similar projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Combined-Accelerated Stress Testing for Advanced Reliability Assessment of Photovoltaic Modules

New and previously undiscovered degradation mechanisms continue to be identified after field exposure in new photovoltaic module designs or materials oftentimes results in significant losses in investment. This is despite passing certification tests. Testing is insufficient largely due to their single-or double-stress nature. A Combined-Accelerated Stress Test (C-AST) has recently been developed. The test combines multiple stress factors of the natural environment to better replicate conditions experienced by modules in the field and detect mechanisms not a-priori known in new materials and designs.

accelerator factor modeling↗

2022 Small Turbine Certification Awardee: Eocycle America Corporation

Eocycle's Competitiveness Improvement Project (CIP) award will fund certification testing of the company's EOX S-16 25-kW turbine to make sure it meets UL electrical safety standards. In addition to validating the turbine's reliability and anticipated reduced maintenance requirements, UL certification will also boost consumer confidence in the technology, with the potential to increase the market for the entire small-wind industry.

Competitiveness Improvement Project↗

2022 Small Turbine Certification Awardee: Ryse Energy LLC - Americas

To meet the growing demands of the distributed wind market and comply with current U.S. standards, Ryse Energy LLC-Americas (Ryse Energy, formerly Primus Wind Power) plans to update all six products in its AIR Range family of micro wind turbines. A new, more cost-effective circuit board will be paired with other hardware upgrades, advanced control algorithms, and a Bluetooth function that allows users to more easily program and control the turbine. This Competitiveness Improvement Project (CIP) award will fund certification testing of the new circuit board to make sure it meets American National Standards Institute/American Clean Power Association (ANSI/ACP) and UL Federal Communications Commission (FCC) safety and quality standards. Primus Wind Power developed the prototype for the new circuit board with an earlier round of CIP funding, and Primus has received CIP awards supporting other certification and optimization projects.

CIP↗