Search NASA⌕ Search

SEARCH · Search NASA

Results for “changes made 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nonlinear optical crystal optimized for Ytterbium laser host wavelengths

A material for harmonic generation has been made by substitutional changes to the crystal LaCa.sub.4 (BO.sub.3).sub.3 also known as LaCOB in the form Re1.sub.xRe2.sub.yRe3.sub.zCa.sub.4(B0.sub.3).sub.3O where Re1 and Re2, (rare earth ion 1 and rare earth ion 2) are selected from the group consisting of Sc, Yttrium, La, Ce, Pr, Nd, Sm, Eu, Gd, Th, Dy, Ho, Er, Tm, Yb, and Lu; Re3 is Lanthanum; and x+y+z=1.

36 MATERIALS SCIENCE↗

Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changes made on a 2.7-m long superconducting solenoid magnet cryogenic system that allowed the magnet to be kept cold using 4 K pulse tube coolers

Two 2.7-m long solenoid magnets with a cold mass of 1400 kg were fabricated in between 2007 and 2010. The magnet cryostat outside diameter is ∼1.4 meters and the cryostat length is ∼2.73 meters. The magnet warm bore is 0.4 meters. The magnet was designed to be cooled using three 1.5 W two-stage coolers. In both magnets, three coolers could not keep the cryostat filled with liquid helium. The temperatures of the shield and the tops of the HTS leads were too warm. A 140 W single stage cooler was added to magnet 2 to cool the HTS leads, the shield and the cold mass support intercepts. When the magnet 2 was retested in 2010, the net cooling at 4.2 K was −1.5 W with first-stage temperatures of the four coolers at ∼42 K. The tops of the HTS leads were <50 K, but the shield and cold mass support intercepts remained too warm. The solenoid cryostat and shield were modified during 2011 and 2012 to reduce the 4.2 K heat load and increase the cooling. This magnet was tested in 2012, with five 1.5 W two-stage coolers and the single stage cooler. The changes made in the magnet are described in this report. As a result of the cryostat and shield changes, and adding 3.0 W of cooling at 4.2 K, the net 4.2 K cooling changed from −1.6 W to +5.0 W. About half of the change in net cooling to this magnet was due changes that reduced the shield temperature. This report demonstrates the importance of running the shield cold (∼40 K) and reducing the heat loads from all sources on both the shield and the cold mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

(U) Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-METFAST-086) identifies two corrections that need to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-METFAST-086 Case 4 in order to estimate the effect on k eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused k eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF-B/VIII.0, have also been used; this caused k eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil and at three external point detectors. Within the fission foil, using ENDF/B-VIII.0 for Godiva-IV induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the point detectors, using ENDF/B-VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in k eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-476: Improving KCl:Eu2+ Dosimeter Sensitivity: The Role of Oxygen

Purpose: Recent research has shown that KCl:Eu2+ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. The purpose of this work is to determine if increased signal could be realized in KCl:Eu2+ by incorporating oxygen in the material fabrication process. Methods: The prototype KCl:Eu2+ dosimeters have a physical makeup similar to thermoluminescent dosimeter chips. The photostimulation light source consists of either a He-Ne laser or a UV enhanced Xe arc lamp with wavelength selection provided by a motorized monochromator. X-ray diffraction is used to determine the phase composition of the dosimeters. Photoluminescence (PL) and photostimulated luminescence (PSL) emission spectra are obtained using a Nanolog Spectrofluoremeter. Results: Europium activator is completely incorporated into the KCl parent-matrix without the formation of a noticeable secondary phase. Regardless of synthesis atmosphere, air or pure nitrogen, PSL amplitude shows a maximum at 1.0 mol % Eu. Depending on europium concentration, dosimeters fabricated in air exhibit stronger PSL by a factor of 2 to 4 compared to those made in N2. There is no change in PSL stimulation spectrum while noticeable shifts in both PL and PSL emission spectra are observed for air versus nitrogen. Almost all charge-storage centers are spatially correlated, suggesting oxygen’s stabilization role in the PSL process. KCl:Eu2+ made in oxygen-rich air is capable of measuring a dose-to-water as low as 0.01 cGy from a 6MV photon beam with a signal-to-noise ratio greater than 6. Conclusions: Synthesis in a reduction atmosphere, for example, nitrogen, was thought to be mandatory in order to retain europium activator’s divalent status to be PSL active. Fortunately, divalent europium can be well preserved in an oxygen-rich atmosphere. More importantly, oxygen can enhance PSL by a factor of 2 to 4. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

36 MATERIALS SCIENCE↗

A Collaborative Proposal: Simulating and Understanding Abrupt Climate-Ecosystem Changes During Holocene with NCAR-CCSM3

We have made significant progress in our proposed work in the last 4 years (3 years plus 1 year of no cost extension). In anticipation of the next phase of study, we have spent time on the abrupt changes since the last glacial maximum. First, we have performed further model-data comparison based on our baseline TRACE-21 simulation and made important progress towards the understanding of several major climate transitions. Second, we have made a significant effort in processing the model output of TRACE-21 and have put this output on a website for access by the community. Third, we have completed many additional sensitivity experiments. In addition, we have organized synthesis workshops to facilitate and promote transient model-data comparison for the international community. Finally, we have identified new areas of interest for Holocene climate changes.

54 ENVIRONMENTAL SCIENCES↗

Collaborative Proposal. Development of an Isotope-Enabled CESM for Testing Abrupt Climate Changes

We have made significant landmarks in our proposed work in the last 4 years (3 years plus 1 year of no cost extension). We have developed the simulation capability of the major isotopes in CESM. In particular, we have completed the implementation of the stable water isotopes (δ 18 O, δD) into the components for the atmosphere, ocean, land surface, runoff transport, sea ice, and coupler. In addition, the carbon isotopes (abiotic and biotic radiocarbon, δ 13 C) have been implemented into the CESM ocean and land models, and long spinup simulations have been completed (Jahn et al., 2015). Furthermore, we have added abiotic Neodymium to the CESM ocean model as a tracer of ocean circulation, also measured by the proxy data community. Fullycoupled simulations with the stable water isotopes and ocean radiocarbon are currently being run for the preindustrial and also the Last Glacial Maximum. We have secured 19 million core-hours on the NWSC Yellowstone supercomputer for 12 months. Together with some CESM Paleoclimate Working Group CSL Yellowstone core hours, we are guaranteed sufficient computing for the spin-up experiments and deglaciation simulations for 21 to 15ka.

54 ENVIRONMENTAL SCIENCES↗

Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Call Response for NEPA Supplement Analysis of CMRR

The Department of Energy/National Nuclear Security Administration (DOE/NNSA) is proposing to provide analytical chemistry (AC) and materials characterization (MC) capabilities at the Los Alamos National Laboratory (LANL) by using a combination of existing space in two existing buildings: the Radiological Laboratory/Utility/Office Building (RLUOB) and the Plutonium Facility, Building 4 (PF-4) in TA-55. This represents a change from decisions made by DOE as informed by previous National Environmental Policy Act (NEPA) analyses. In accordance with Council on Environmental Quality (CEQ) and DOE requirements, NNSA is preparing a Supplement Analysis (SA) to evaluate the potential environmental impacts of the proposed action. The focus of this analysis is on determining whether the proposal to provide AC and MC laboratory capabilities in existing space in RLUOB and PF-4 rather than building a new nuclear facility (NF) is a substantial change that is relevant to environmental concerns or whether new circumstance or information relevant to environmental concerns and bearing on the proposed action or its impacts are significant. The end result of the analysis is a determination whether the existing Chemistry and Metallurgy Research Building Replacement Environmental Impact Statement (CMRR EIS) should be supplemented, a new EIS should be prepared, or no further NEPA analysis is necessary. This report provides data for incorporation into the Supplement Analysis being written by Leidos, Inc. under contract to NNSA. Responding to the data call requires several areas of expertise. Los Alamos subject matter experts estimate equipments lists, facility modifications, waste quantities, labor needs and radiological doses. Los Alamos NEPA experts assist Leidos in compiling existing data from the LANL Site-Wide Environmental Impact Statement (SWEIS) and CMRR EIS for public and other impacts. Bounding conditions are used to determine NEPA estimates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Data Analysis for NEPA Supplement Analysis of Chemistry and Metallurgy Research Building Replacement Project at LANL - 16017

The Department of Energy/National Nuclear Security Administration (DOE/NNSA) is proposing to provide analytical chemistry (AC) and materials characterization (MC) capabilities at the Los Alamos National Laboratory (LANL) by using a combination of existing space in two existing buildings: The Radiological Laboratory/Utility/Office Building (RLUOB) and the Plutonium Facility, Building 4 (PF-4) in TA-55. This represents a change from decisions made by DOE as informed by previous National Environmental Policy Act (NEPA) analyses. In accordance with Council on Environmental Quality and DOE requirements, NNSA prepared a Supplement Analysis to evaluate the potential environmental impacts of the proposed action. The focus of this analysis is on determining whether the proposal to provide AC and MC laboratory capabilities in existing space in RLUOB and PF-4 rather than building a new nuclear facility is a substantial change that is relevant to environmental concerns or whether new circumstance or information relevant to environmental concerns and bearing on the proposed action or its impacts are significant. The determination of the analysis is that the existing Chemistry and Metallurgy Research Building Replacement Environmental Impact Statement (CMRR EIS) need not be supplemented, nor is a new EIS required, because 'the proposed changes do not represent a substantial change that is relevant to environmental concerns.'[1 p.49] No further NEPA analysis is necessary. This report describes the analysis used to create data needed for the Supplement Analysis. Los Alamos subject matter experts estimated equipment lists, facility modifications, waste quantities, labor needs and radiological doses. Los Alamos NEPA experts assisted in compiling existing data from the LANL Site-Wide EIS and CMRR EIS for public and other impacts. Bounding conditions were used to determine NEPA estimates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microstructural and electrical properties of PVA/PVP polymer blend films doped with cupric sulphate

A series of polyvinyl alcohol (PVA)/polyvinyl pyrrolidone (PVP) polymer blends added with different concentrations of cupric sulphate (CuSO{sub 4}) were prepared by solution casting method and were subjected to X-ray diffraction (XRD) and Ac conductance measurements. An attempt has been made to study the changes in crystal imperfection parameters in PVA/PVP blend films with the increase in concentration of CuSO{sub 4}. Results show that decrease in micro crystalline parameter values is accompanied with increase in the amorphous content in the film which is the reason for film to have more flexibility, biodegradability and good ionic conductivity. AC conductance measurements in these films show that the conductivity increases as the concentration of CuSO{sub 4} increases. These films were suitable for electro chemical applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integral Experiment Request 554: CED-2 Summary Report

This report summarizes the critical experiment design 2 (CED-2) or final design study for Integral Experiment Request 554 (IER-554). This experiment describes the effects and importance of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments (7uPCX) at Sandia National Laboratories. The neutron absorber plates considered for the experiment are known as Boralcan and are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum were changed as well as the thickness and the positions of the plates, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 6 critical configurations, each with a neutron absorber plate inserted, are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. As part of the final design of the experiment, a safe plate holder made of 3003 aluminum was designed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly, and the CED-3 phase can start when funding allows.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hexagonal Geometries in MPACT

The MPACT code is a high-fidelity light-water reactor analysis code using whole-core pin-resolved neutron transport calculations on modern parallel-computing hardware. MPACT uses the 2D/1D method to solve 3D neutron transport problems by decomposing the problem into a stack of 2D slices, each of which is solved independently using the method of characteristics (MOC). The slices are then coupled axially using the P3 nodal expansion method (NEM-P3) for the 1D axial calculations. MPACT also employs the coarse mesh finite difference (CMFD) method to accelerate calculations. This manuscript details work supporting advanced reactor designs using hexagonal pins and hexagonal assemblies such as the VVER-1000. If performed correctly, MOC is geometry agnostic. However, MPACT previously had optimizations in place for Cartesian geometries, specifically in the modularization and current calculations. Sections 2 and 3 detail the changes made to MPACT to support MOC and CMFD calculations on hexagonal geometries. Section 4 reports results demonstrating solution consistency for problems run with and without CMFD acceleration, results demonstrating solution consistency when run in serial and parallel, and pincell results using the Monte Carlo code, McCard’s benchmark results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MO-E-18C-03: Incorporating Active Learning Into A Traditional Graduate Medical Physics Course

Purpose: To improve the ability of graduate students to learn medical physics concepts through the incorporation of active learning techniques. Methods: A traditional lecture-based radiological physics course was modified such that: (1) traditional (two-hour) lectures were provided online for students to watch prior to class, (2) a student was chosen randomly at the start of each class to give a two minute synopsis of the material and its relevance (two-minute drill), (3) lectures were significantly abbreviated and remaining classroom time used for group problem solving, and (4) videos of the abbreviated lectures were made available online for review. In the transition year, students were surveyed about the perceived effects of these changes on learning. Student performance was evaluated for 3 years prior to and 4 years after modification. Results: The survey tool used a five point scale from 1=Not True to 5=Very True. While nearly all students reviewed written materials prior to class (4.3±0.9), a minority watched the lectures (2.1±1.5). A larger number watched the abbreviated lectures for further clarification (3.6±1.6) and found it helpful in learning the content (4.2±1.0). Most felt that the two-minute drill helped them get more out of the lecture (3.9±0.8) and the problem solving contributed to their understanding of the content (4.1±0.8). However, no significant improvement in exam scores resulted from the modifications (mean scores well within 1 SD during study period). Conclusion: Students felt that active learning techniques improved their ability to learn the material in what is considered the most difficult course in the program. They valued the ability to review the abbreviated class lecture more than the opportunity to watch traditional lectures prior to class. While no significant changes in student performance were observed, aptitude variations across the student cohorts make it difficult to draw conclusions about the effectiveness of active learning.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Corrigendum to “Cross-sectoral assessment of CO2 capture from U.S. industrial flue gases for fuels and chemicals manufacture” [International Journal of Greenhouse Gas Control 135 (2024) 1-20 / 104137]

The authors regret the inaccuracy in the vertical axis title of Fig. 4 and the distortion in the legend of Fig. 13. Corrections have been made to the vertical axis title and legend of Figs. 4 and 13, respectively. These changes do not affect the analysis, calculations, or results in any way. The authors apologize for any inconvenience caused. The corrected figures are as follows:

Zuberi, M Jibran S↗

Towards an Understanding of Enhanced Biomass Digestibility by In Planta Expression of a Family 5 Glycoside Hydrolase

In planta expression of a thermophilic endoglucanase (AcCel5A) reduces recalcitrance by creating voids and other irregularities in cell walls of Arabidopsis thaliana that increase enzyme accessibility without negative impacts on plant growth or cell wall composition. Furthermore, our results suggest that cellulose β-1–4 linkages can be cut sparingly in the assembling wall and that these minimal changes, made at the proper time, have an impact on plant cell wall recalcitrance without negative effects on overall plant development.

09 BIOMASS FUELS↗