Search NASA⌕ Search

SEARCH · Search NASA

Results for “characterization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Report on Development of Critical Field Testing and Site Characterization Techniques

Characterizing subsurface structures is crucial for used fuel disposition. It is necessary to apply the-state of-art geophysical techniques to ensure safe and cost-effective used fuel disposition. This report summarizes the most up-to-date geophysical techniques to achieve this goal, particularly for fault and fracture characterization. These techniques include non-invasive methods that are suitable for the early stage of site characterization, and invasive methods that can be applied when the sites are under development. These methods can provide subsurface mechanical and electrical properties, which can help determine surface structures and rock types. Particularly, these methods can determine various parameters of fault and fracture zones, such as the location, dip, width, and activeness.

Earth Sciences↗

Advanced Characterization Techniques in Promoting Mechanism Understanding for Lithium-Sulfur Batteries

Due to the numerous advantages, such as high specific capacity, etc., lithium-sulfur batteries (Li-S batteries) have attracted much attention as next-generation energy storage systems. To meet future needs for commercial application, Li-S batteries will require both improved cycle life and high energy density. It is of critical importance to understand the fundamental mechanisms in Li-S system to further improve the whole battery performance. Various advanced characterization techniques, over the past few years, have proven their important role in promoting the mechanism understanding for Li-S batteries. Here, we review the recent progress of mechanism understanding, including redox reactions, Li polysulfides dissolution, and etc., in Li-S systems based on the advanced characterization techniques. Special focus is placed on how these advanced characterization techniques are being employed and what characteristic or capability they possess. The necessity of combination of multiple characterization, difference between ex situ and in situ experimental methods, as well as importance of characterization conditions in Li-S batteries are also discussed.

Zhao, Enyue↗

On-Shot Focal-Spot Characterization Technique Using Phase Retrieval

We present an on-shot focal-spot characterization technique based on a phase-retrieval scheme that retrieves near-field phase from multiplane focal-spot measurements in an experimental target chamber. The technique is easy to implement inside a target chamber and is demonstrated in a multiterawatt laser system. It is also found that phase retrieval can quantitatively detect residual angular dispersion coming from the pulse compressor misalignment.

Bahk, S -W↗

Design and optimization of stepped austempered ductile iron using characterization techniques

Conventional characterization techniques such as dilatometry, X-ray diffraction and metallography were used to select and optimize temperatures and times for conventional and stepped austempering. Austenitization and conventional austempering time was selected when the dilatometry graphs showed a constant expansion value. A special heat color-etching technique was applied to distinguish between the untransformed austenite and high carbon stabilized austenite which had formed during the treatments. Finally, it was found that carbide precipitation was absent during the stepped austempering in contrast to conventional austempering, on which carbide evidence was found. - Highlights: • Dilatometry helped to establish austenitization and austempering parameters. • Untransformed austenite was present even for longer processing times. • Ausferrite formed during stepped austempering caused important reinforcement effect. • Carbide precipitation was absent during stepped treatment.

36 MATERIALS SCIENCE↗

Evaluation of Characterization Techniques for Iron Pipe Corrosion Products and Iron Oxide Thin Films

A common problem faced by drinking water studies is that of properly characterizing the corrosion products (CP) in iron pipescor synthetic Fe (hydr)oxides used to simulate the iron pipe used in municipal drinking-water systems. The present work compares the relative applicability of a suite of imaging and analytical techniques for the characterization of CPs and synthetic Fe oxide thin films and provide an overview of the type of data that each instrument can provide as well as their limitations to help researchers and consultants choose the best technique for a given task. Crushed CP from a water distribution system and synthetic Fe oxide thin films formed on glass surfaces were chosen as test samples for this evaluation. The CP and synthetic Fe oxide thin films were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive spectroscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray powder diffractometry (XRD), grazing incident diffractometry (GID), transmission electron microscopy (TEM), selected area electron diffraction, X-ray photoelectron spectroscopy (XPS), Fourier transform infrared, Mössbauer spectroscopy, Brunauer-Emmett-Teller N2 adsorption and Fe concentration was determined by the ferrozine method. XRD and GID were found to be the most suitable techniques for identification of the mineralogical composition of CP and synthetic Fe oxide thin films, respectively. AFM and a combined ToF-SIMS-AFM approach proved excellent for roughness and depth profiling analysis of synthetic Fe oxide thin films, respectively. Corrosion products were difficult to study by AFM due to their surface roughness, while synthetic Fe oxide thin films resisted most spectroscopic methods due to their limited thickness (118 nm). XPS analysis is not recommended for mixtures of Fe (hydr)oxides due to their spectral similarities. SEM and TEM provided great detail on mineralogical morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization Techniques Investigated for Characterization of Anomalous Materials in Plutonium Oxide – 25666

The DOE has adopted a Dilute and Dispose approach for processing surplus plutonium which consists of blending plutonium oxide with adulterants and packaging it in a form which is acceptable for disposal at the Waste Isolation Pilot Plant. The feed material for the downblend process is intended to be pure plutonium oxide powder, however other objects are occasionally encountered within the oxide, particularly with legacy material. Potential technologies which could assist in the resolution of incidents where such anomalies are encountered have been investigated. Resolution of these incidents requires characterization of the anomalous object so that plutonium oxide processing can resume and so that a disposition pathway can be determined for the anomalous material. Technologies including gamma ray spectroscopy, alpha-gamma coincidence, LiDAR volumetric measurements, and surface conductivity measurements were investigated for this purpose, with a focus on systems which can be easily introduced into the processing environment when an anomaly is encountered, then removed from the environment after resolution to avoid impeding normal processing activities. This places an emphasis on small and portable measurement systems and systems that can operate in a high-background, oxide-processing environment. Gamma ray systems investigated include the GR1™a CZT detector and the MicroGe™a germanium detector, with a focus on detecting characteristic gamma rays from Pu-239 and other actinides. A gamma ray and alpha particle coincidence method was investigated with the goal of identifying actinides in the presence of a gamma ray background produced by adjacent plutonium oxide material. Leica™b BLK360 G1 and Keyence™c LJ-X8300 LiDAR systems were investigated for use in conjunction with mass measurements to gain accurate material density values, and a Foerster Sigmatest™d 2.070 was tested to determine surface conductivity. The combination of these properties would allow improved identification and characterization of a wide variety of potential anomalous material.

Munson, Justin M.↗

Effect of Jitter on Linear Pulse-Characterization Techniques

Linear pulse-characterization techniques based on electrically driven temporal modulators can measure the electric field of optical pulses with high sensitivity and accuracy. Synchronization of the electric-drive signal to the optical source under test is paramount to their implementation, and it is important to understand the impact of relative synchronization jitter on the measured experimental trace and on the reconstructed electric field. Derivations and simulations are presented for linear spectrography, spectral shearing interferometry, and simplified chronocyclic tomography. For these three techniques, accurate characterization is obtained for relative jitter with a standard deviation as high as several times the pulse duration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A quantifiable and automated volume fraction characterization technique for secondary and tertiary γ′ precipitates in Ni-based superalloys

Highlights: • A new, automated γ′ volume fraction characterization technique has been introduced for Ni-base superalloys. • New image processing techniques can automatically and accurately segment γ′ precipitates from the surrounding γ matrix. • CALPHAD and γ′ phase extraction measurements validate the new characterization technique. - Abstract: Ni-based superalloys are extensively used in high temperature, high stress applications. The presence of coherent γ′-Ni{sub 3}Al precipitates provides the requisite elevated temperature strength and creep resistance in these alloys. Therefore, quantification of the precipitate size distribution and volume fraction is essential for accurate model predictions and future alloy design. Current γ′ volume fraction characterization techniques suffer from a lack of precision and repeatability. Without a reproducible procedure, unacceptable variations and errors have plagued the past 6 decades of superalloys research and have inhibited the implementation of accurate precipitation models for these alloys. Through the use of high resolution, low kV, scanning electron microscopy and state-of-the-art image post-processing, a new, accurate γ′ characterization technique is presented. Using the new technique, secondary γ′ volume fractions in superalloy ME3 were calculated, and confirmed through phase extraction, thus opening the possibility for validation of presently used superalloy precipitation databases.

36 MATERIALS SCIENCE↗

Electro-analytical method for the quantities evaluation of the silicon solar cell by DC and AC characterization technique

Highlights: • Exact electro-analytical method for evaluation of silicon solar cells. • DC and AC characterization technique to determine the performance limiting parameters of solar cells. • EIS is used to get an insight into the solar cells and parameter optimization. - Abstract: Mono and Poly- crystalline silicon (Si) based solar cell has proven to be the most efficient and matured technology till date. The present work reports an exact electro-analytical method for the evaluation of different performance parameters in the current voltage response of the Si solar cell by DC and AC characterization technique. The extracted solar cell parameters from DC and AC techniques were compared with each other under the proper limiting conditions of low and high forward bias. The DC and AC characterization are used to determine the bias dependence of ideality factor and series resistance, respectively. The current-voltage (J-V) characteristics is combined with the impedance spectroscopy (IS) measurements to reveal the various interfacial, resistive and recombination analysis of the silicon solar cell. Herein the experimentally obtained J-V characteristics under the illumination condition have been reconstructed by individually extracted parameters from DC and AC measurements. Moreover, the present mechanistic provides a simple tool for analysing the commercial Si solar cell with a wide applicability for other solar cells.

14 SOLAR ENERGY↗

TU-F-CAMPUS-I-02: Validation of a CT X-Ray Source Characterization Technique for Dose Computation Using An Anthropomorphic Thorax Phantom

Purpose: To experimentally validate a rotational kV x-ray source characterization technique by computing CT dose in an anthropomorphic thorax phantom using an in-house dose computation algorithm (kVDoseCalc). Methods: The lateral variation in incident energy spectra of a GE Optima big bore CT scanner was found by measuring the HVL along the internal, full bow-tie filter axis. The HVL and kVp were used to generate the x-ray spectra using Spektr software, while beam fluence was derived by dividing the integral product of the spectra and in-air mass-energy absorption coefficients by in-air dose measurements along the bow-tie filter axis. Beams produced by the GE Optima scanner were modeled at 80 and 140 kVp tube settings. kVDoseCalc calculates dose by solving the linear Boltzmann transport equation using a combination of deterministic and stochastic methods. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima scanner were measured using a (0.015 cc) PTW Freiburg ionization chamber, and compared to computations from kVDoseCalc. Results: The agreement in relative dose between dose computation and measurement for points of interest (POIs) within the primary path of the beam was within experimental uncertainty for both energies, however points outside the primary beam were not. The average absolute percent difference for POIs within the primary path of the beam was 1.37% and 5.16% for 80 and 140 kVp, respectively. The minimum and maximum absolute percent difference for both energies and all POIs within the primary path of the beam was 0.151% and 6.41%, respectively. Conclusion: The CT x-ray source characterization technique based on HVL measurements and kVp can be used to accurately compute CT dose in an anthropomorphic thorax phantom.

60 APPLIED LIFE SCIENCES↗