Some penetration and charge-detection techniques
Meteoritic dust penetration and charge detection techniques used on Skylark rocket and Ariel II satellite
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Meteoritic dust penetration and charge detection techniques used on Skylark rocket and Ariel II satellite
Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.
Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Finally, combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.
The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. In conclusion, we have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Windowless continuous-channel electron multiplier detecting low energy charged particles in space
Low energy charged particle detection with continuous channel electron multiplier
The primary goal of this report is to develop a universal charge fault detection method that requires only a few experimental data with high prediction accuracy. Currently, pump-down operations is typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repair. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The new charge fault detection and diagnostics method innovatively utilizes the typical pump down operation, the compressor’s low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.
The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.
The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.
The theory of the hyperbolic retarding potential analyzer in the electrostatic mode is developed in detail and verified in the laboratory. A monoenergetic electron beam is used for the laboratory investigation. The analyzer (acronym HARP) has advantages over other conventional electrostatic analyzers; among them are less contact potential influence and high throughput because of the symmetry shape of the analyzer. The most useful application of the HARP is in detecting low-energy charged particles. A sample of low-energy particle data obtained in the earth's ionosphere is given.
Continuous channel electron multiplier with saturated pulse independent of excitation for low energy charged particle detection
The design and characteristics of a gas radiation counter are discussed. The coaxial anode consists of an elongated central wire covered with an electrically insulating sleeve. Several longitudinally discontinuous segments of an electrically conductive coating are disposed about the insulating sleeve in a coaxial pattern along the length of the central wire. The conductive coating segments form a veto or rejection anode at each end of the central wire and a main or primary charge detecting anode between the ends. The segments are coupled together so that the primary charge detecting anode is connected to detection circuitry in anti-coincidence with the veto anodes. Background radiation detected by either of the veto anodes and the primary charge detecting anode is rejected and the sensitivity of the radiation counter device is increased.
Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.
Ionizing radiation from cosmic rays and gammas can induce discontinuous jumps in the environmental charge of superconducting qubits (charge jumps), causing correlated errors that challenge fault-tolerant quantum computing while simultaneously providing a detection signature for quantum sensing applications. Current detection methods operate offline, introducing latency incompatible with in-the-loop qubit control. In this paper, an online detector of charge jumps for superconducting qubits, based on a dilated causal convolutional neural network (DCCNN) designed for in-the-loop deployment on the Quantum Instrumentation Control Kit (QICK) platform, is presented. The network is trained on synthetic Ramsey tomography scans generated from qubit templates measured at the Northwestern Experimental Underground Site (NEXUS) at Fermilab, and translated to FPGA firmware via hls4ml with ap_fixed$\langle 16,6 \rangle$ quantization, reaching a per-inference latency of $6.19 μ$s on the Zynq UltraScale+ RFSoC ZCU216. At this operating point the DCCNN matches the detection efficiency of the established offline $χ^2$ algorithm ($0.843 \pm 0.022$ vs. $0.866 \pm 0.020$ on $|Δq| \in [0.1, 0.5] e$ at matched false-positive rate), while requiring no per-qubit hyperparameter tuning. This shifts charge-jump detection from a post-hoc diagnostic to a control-loop primitive, enabling adaptive protocols that respond to radiation-induced events in situ, with applications to quantum-computing error mitigation and to the use of superconducting qubits as particle detectors.
One electron at a time, photosynthetic biohybrids enable charge accumulation via the flavin semiquinone of ferredoxin-NADP + reductase.