Delta-doped CCD's as low-energy particle detectors and imagers

The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to detect very low-energy particles that penetrate less than 1.0 nm into the CCD, including electrons having energies less than 1000 eV and protons having energies less than 10 keV.

Nikzad, Shouleh↗

Using a delta-doped CCD to determine the energy of a low-energy particle

The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to determine the energy of a very low-energy particle that penetrates less than 1.0 nm into the CCD, such as a proton having energy less than 10 keV.

Nikzad, Shouleh↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Characterization of skipper CCDs for cosmological applications

We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise &sigma; 0.18 e - rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Applications of charge-coupled device transversal filters to communication

The paper discusses the computational power of state-of-the-art charged-coupled device (CCD) transversal filters in communications applications. Some of the performance limitations of CCD transversal filters are discussed, with attention given to time delay and bandwidth, imperfect charge transfer efficiency, weighting coefficient error, noise, and linearity. The application of CCD transversal filters to matched filtering, spectral filtering, and Fourier analysis is examined. Techniques for making programmable transversal filters are briefly outlined.

Buss, D. D.↗

Design of an Event-Driven Random-Access-Windowing CCD-Based Camera

Commercially available cameras are not design for the combination of single frame and high-speed streaming digital video with real-time control of size and location of multiple regions-of-interest (ROI). A new control paradigm is defined to eliminate the tight coupling between the camera logic and the host controller. This functionality is achieved by defining the indivisible pixel read out operation on a per ROI basis with in-camera time keeping capability. This methodology provides a Random Access, Real-Time, Event-driven (RARE) camera for adaptive camera control and is will suited for target tracking applications requiring autonomous control of multiple ROI's. This methodology additionally provides for reduced ROI read out time and higher frame rates compared to the original architecture by avoiding external control intervention during the ROI read out process.

event driven↗

Fabricating a hybrid imaging device having non-destructive sense nodes

A hybrid detector or imager includes two substrates fabricated under incompatible processes. An array of detectors, such as charged-coupled devices, are formed on the first substrate using a CCD fabrication process, such as a buried channel or peristaltic process. One or more charge-converting amplifiers are formed on a second substrate using a CMOS fabrication process. The two substrates are then bonded together to form a hybrid detector.

Wadsworth, Mark↗

Fabricating a hybrid imaging device

A hybrid detector or imager includes two substrates fabricated under incompatible processes. An array of detectors, such as charged-coupled devices, are formed on the first substrate using a CCD fabrication process, such as a buried channel or peristaltic process. One or more charge-converting amplifiers are formed on a second substrate using a CMOS fabrication process. The two substrates are then bonded together to form a hybrid detector.

Wadsworth, Mark↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic pictures from charged-coupled devices

Imaging system uses charge-coupled devices (CCD's) to generate TV-like pictures with high resolution, sensitivity, and signal-to-noise ratio. It combines detectors for five spectral bands as well as processing and control circuitry all on single silicon chip.

Mccann, D. H.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗