Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Examining the effects of chemical cleaning, leaching, and partial dissolution on zinc and cadmium isotope fractionation in marine carbonates

The application of zinc (Zn) and cadmium (Cd) isotopes as palaeo-proxies in carbonate sediment is rapidly expanding due to their potential for tracing changes in biological productivity in the modern and past oceans. However, there are limited investigations into the chemical cleaning methods required to produce the most consistent and accurate data for these novel isotope systems. This could impact their use as palaeo-proxies to reconstruct ocean-atmosphere-climate interactions throughout Earth's history. To address this concern and expand the utility of the Zn and Cd stable isotope systems as palaeo-productivity tracers, the performance of two standard chemical cleaning protocols for acquiring robust and reliable Zn and Cd isotope datasets were assessed. These include (i) the Cd-cleaning method that uses a reductive step to selectively leach contaminating secondary iron (Fe)-manganese (Mn) (oxyhydr)oxide coatings from the carbonate surface, and an oxidative step that is used to remove post-depositional organic matter and sulphide precipitates; and (ii) the magnesium/calcium cleaning protocol that includes an oxidative step only, leaving secondary Fesingle bondMn (oxyhydr)oxide coatings largely intact. Well-preserved Holocene-, and Mesozoic-aged carbonate sediments were used to test the reliability of these two chemical cleaning methods. The Holocene samples comprised not only aliquots of bulk sediment, but also individual species of planktic and benthic foraminifera. Our results show that the best practice chemical cleaning method for retrieving consistent and accurate Zn and Cd isotope, and Zn/Ca and Cd/Ca datasets for carbonate sediments, requires both reductive and oxidative cleaning following the Cd-cleaning method. This differs from most methodological approaches applied to date that remove the reductive step from the chemical cleaning protocol and apply an oxidative step only, or no chemical cleaning at all. Inclusion of the reductive step in the chemical cleaning method typically shifts δ 66 Zn by ~0.1‰ lower and δ 114 Cd by 0.3‰ higher in the solid phase, while Zn/Ca and Cd/Ca typically decrease 2-fold. The benthic foraminifera, C. wuellerstorfi, that live in ocean bottom waters where the seawater Zn and Cd isotope composition is homogeneous display evidence of Zn and Cd isotope fractionation between seawater and carbonate on the order of 0.08 ± 0.08‰ (2SE, n = 4) and -0.25 ± 0.13‰ (2SE, n = 4), respectively, in agreement with experimental constraints. Furthermore, evidence of Zn isotope fractionation effects are recorded in a naturally-dissolved carbonate sediment, together with laboratory-controlled carbonate dissolution experiments. Based on these results, we recommend the Cd-cleaning method and the application of Zn and Cd isotope fractionation factors to accurately reconstruct past seawater Zn and Cd isotope compositions from carbonate sediments.

58 GEOSCIENCES↗

Optimizing a chemical cleaning protocol to determine the nickel isotopic composition of ancient seawater from carbonates

Reconstructing the ancient marine cycle of Ni, a trace metal in the oceans essential to enzymes regulating the C, N, and O cycles, would inform how Ni bioavailability shaped early life. The Ni isotopic composition of seawater (δ 60 Ni SW ) through time could provide insight, but this approach requires sedimentary archives that faithfully record δ 60 Ni SW . Carbonates are an often-used record of seawater chemistry, but contaminants could bias the measured δ 60 Ni of bulk sediment. To isolate the true carbonate-bound δ 60 Ni signal, we optimized a chemical cleaning protocol designed to minimize non‑carbonate Ni contributions and maximize carbonate recovery. We analyzed ODP Site 1007 sediments and evaluated oxidative and reductive pre-cleaning steps and carbonate dissolution protocols. Our results show that only reductive cleaning significantly altered the subsequent carbonate leachate composition, lowering Ni/Ca ratios by up to 60% and δ 60 Ni values by as much as 0.4 ‰. In contrast, δ 60 Ni values were largely insensitive to premature carbonate dissolution during pre-cleaning or to partial leaching of silicates during carbonate dissolution, even at higher acid molarities or longer reaction times. We recommend an evidence-based protocol that removes hydro-soluble salts and clays, applies reductive cleaning and oxidative cleaning for certain sample compositions, and dissolves carbonate using 0.5 M acetic acid, adjusted to pH 5. Using these results, we infer a ∼ 0.9 ‰ Ni isotopic fractionation between chemically cleaned deep-water carbonates (+0.4 ± 0.1 ‰) and deep seawater. This method development is a key step toward accurately reconstructing ancient marine Ni cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Non-Ozone-Depleting-Chemical Cleaning Methods for Space Mechanisms Using a Vacuum Spiral Orbit Rolling Contact Tribometer

Because CFC 113, an ozone depleting chemical (ODC), can no longer be produced, alternative bearing cleaning methods must be studied. The objective of this work was to study the effect of the new cleaning methods on lubricant lifetime using a vacuum bearing simulator (spiral orbit rolling contact tribometer). Four alternative cleaning methods were studied: ultra-violet (UV) ozone, aqueous levigated alumina slurry (ALAS), super critical fluid (SCF) CO2 and aqueous Brulin 815GD. Baseline tests were done using CFC 113. Test conditions were the following: a vacuum of at least 1.3 x 10(exp -6) Pa, 440C steel components, a rotational speed of 10 RPM, a lubricant charge of between 60-75 micrograms, a perfluoropolyalkylether lubricant (Z-25), and a load of 200N (44.6 lbs., a mean Hertzian stress of 1.5 GPa). Normalized lubricant lifetime was determined by dividing the total number of ball orbits by the amount of lubricant. The failure condition was a friction coefficient of 0.38. Post-test XPS analysis was also performed, showing slight variations in post-cleaning surface chemistry. Statistical analysis of the resultant data was conducted and it was determined that the data sets were most directly comparable when subjected to a natural log transformation. The natural log life (NL-Life) data for each cleaning method were reasonably normally (statistically) distributed and yielded standard deviations that were not significantly different among the five cleaning methods investigated. This made comparison of their NL-Life means very straightforward using a Bonferroni multiple comparison of means procedure. This procedure showed that the ALAS, UV-ozone and CFC 113 methods were not statistically significantly different from one another with respect to mean NL-Life. It also found that the SCF CO2 method yielded a significantly higher mean NL-Life than the mean NL-Lives of the ALAS, UV-ozone and CFC 113 methods. It also determined that the aqueous Brulin 815GD method yielded a mean NL-Life that was statistically significantly higher than the mean NL-Lives of each of the other four methods. Baseline tests using CFC 113 cleaned parts yielded a mean NL-Life 3.62 orbits/micro-g. ALAS and UV-ozone yielded similar mean NL-Life (3.31 orbits/mg and 3.33 orbits/micro-g, respectively). SCF CO2, gave a mean NL-Life of 4.08 orbits/mg and aqueous Brulin 8l5GD data yielded the longest mean NL-Life (4.66 orbits/micro-g).

Jansen, Mark J.↗

Cleaning chemistry of InSb(100) molecular beam epitaxy substrates

InSb has been used as a substrate for molecular beam epitaxy. For good epitaxial growth, a substrate surface which is smooth and clean on an atomic scale is required. Chemical cleaning procedures provide an oxide film to passivate the surface. This film is then desorbed by in situ heating. The material forming the film should, therefore, have a high vapor pressure at some temperature less than the substrate melting temperature. A chloride film appears to satisfy the latter requirement. The present investigation is, therefore, concerned with the formation of a chloride film rather than an oxide film. Carbon contamination has been found to cause problems in chemical cleaning procedures. The level of carbon contamination found in the case of chloride film formation, is therefore compared with the corresponding level observed in procedures using oxide films. It appears that a chloride film grown in connection with a short exposure time to a Cl2 plasma is preferable to other passivation films studied.

Vasquez, R. P.↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluidized-Bed Cleaning of Silicon Particles

Fluidized-bed chemical cleaning process developed to remove metallic impurities from small silicon particles. Particles (250 micrometer in size) utilized as seed material in silane pyrolysis process for production of 1-mm-size silicon. Product silicon (1 mm in size) used as raw material for fabrication of solar cells and other semiconductor devices. Principal cleaning step is wash in mixture of hydrochloric and nitric acids, leaching out metals and carrying them away as soluble chlorides. Particles fluidized by cleaning solution to assure good mixing and uniform wetting.

Rohatgi, Naresh K.↗

Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

Goreva, Y. S.↗

Retrieving Tarnished Daguerreotype Content Using X-ray Fluorescence Imaging—Recent Observations on the Effect of Chemical and Electrochemical Cleaning Methods

We report a study on the effect of chemical and electrochemical cleaning of tarnished daguerreotypes observed using X-ray fluorescence (XRF) microscopy with a micro-focussed X-ray beam from a synchrotron source. It has been found that, while both techniques result in some success depending on the condition of the plate and the experimental parameters (chemical concentration, voltage, current, etc.) the effect varies, and cleaning is often incomplete. The XRF images using Hg Lα,β at an excitation energy just above the L3 edge threshold produce fine images, regardless of the treatment. This finding confirms previous observations that if the bulk of the image particles remains intact, the surface tarnish has little effect on the quality of the original daguerreotype image retrievable from XRF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Genesis Concentrator Target Particle Contamination Mapping and Material Identification

The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report are fully intact and do not show any signs of material fractures. However, previous ellipsometry results and overview imaging of both flown SiC targets show a solar wind irradiation gradient from the center focal point to the outer edge [3]. In addition, due to the hard landing, each target has experienced varying degrees of impacts, scratches, and particle debris from the spacecraft and Utah impact site.

Calaway, Michael J.↗

Preparation and cleanliness verifications of a space simulation chamber for contamination sensitive test specimens

Contamination sensitive optical devices were to be evaluated under thermal vacuum conditions. Test specifications called for an extremely clean chamber environment, ambient temperature chamber walls, and optical surface temperatures at approximately - 30 C. Chamber preparation included the replacement of diffusion pumps with cryopumps and the cleaning of the chamber walls to reduce contamination levels. Chamber cleaning using vacuum bake was tried and abandoned as time consuming and ineffective. Chemical cleaning and cleanliness verification methods were developed. Gas chromatograph analysis techniques were used extensively throughout the cleaning process to verify cleanliness levels prior to evacuating the chamber. A chamber cleanliness verification test using a thermoelectric quartz crystal microbalance and witness samples was performed to demonstrate that an appropriate cleanliness level was achieved.

Koch, W. R.↗

Distinguishing Desirable and Undesirable Reactions in Multicomponent Systems for Redox Activation of the Uranyl Ion

Although it has been established that covalent functionalization of the U–O bonds in the uranyl dication (UO 2 2+ ) generally requires use of strong reductants and electrophiles, little work has examined how interactions between the individual reaction components could affect final outcomes in solution. Here, the patterns of such reactivity have been studied in a UO 2 2+ -containing model system supported by a workhorse pentadentate ligand, 2,2′-[(methylimino)bis(2,1-ethanediylnitrilomethylidyne)]bis-phenol. Oxo activation and functionalization have been tested with (i) electrochemical and chemical reduction, and (ii) coordinating and noncoordinating solvents. In acetonitrile, uranyl reduction was achieved cleanly, but treatment of the reduced species with tris(pentafluorophenyl)borane (BCF) resulted in a mixture of products arising from direct electron transfer to BCF. In dichloromethane (CH 2 Cl 2 ), electrochemical reduction of uranyl was achieved cleanly, but clean chemical reactivity was inaccessible. Despite these challenges, one trinuclear and oxo-deficient uranium-containing product was crystallized from CH 2 Cl 2 solution and characterized; thus, desirable electrophilic reactivity can proceed to some degree in CH 2 Cl 2 with BCF. Computational studies were used to investigate the properties of the trinuclear uranium product and the changes that could be inducible by further reduction. Here, taken together, the reactivity patterns identified here could inform design of improved systems for actinyl oxo functionalization.

cations↗

The Role of Interfaces and Charge for Chemical Reactivity in Microdroplets

A wide variety of reactions are reported to be dramatically accelerated in aqueous microdroplets, making them a promising platform for environmentally clean chemical synthesis. However, to fully utilize the microdroplets for accelerating chemical reactions requires a fundamental understanding of how microdroplet chemistry differs from that of a homogeneous phase. Here, in this work, we provide our perspective on recent progress to this end, both experimentally and theoretically. We begin by reviewing the many ways in which microdroplets can be prepared, creating water/hydrophobic interfaces that have been frequently implicated in microdroplet reactivity due to preferential surface adsorption of solutes, persistent electric fields, and their acidity or basicity. These features of the interface interplay with specific mechanisms proposed for microdroplet reactivity, including partial solvation, possible gas phase channels, and the presence of highly reactive intermediates. We especially highlight the role of droplet charge and associated electric fields, which appears to be key to understanding how certain reactions, like the formation of hydrogen peroxide and reduced transition metal complexes, are thermodynamically possible in microdroplets. Lastly, we emphasize opportunities for theoretical advances and suggest experiments that would greatly enhance our understanding of this fascinating subject.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System

NASA Kennedy Space Center (KSC) recently entered into a nonexclusive license agreement with Applied Cryogenic Solutions (ACS), Inc. (Galveston, TX) to commercialize its Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System technology. This technology, developed by KSC, is a critical component of processes being developed and commercialized by ACS to replace current mechanical and chemical cleaning and descaling methods used by numerous industries. Pilot trials on heat exchanger tubing components have shown that the ACS technology provides for: Superior cleaning in a much shorter period of time. Lower energy and labor requirements for cleaning and de-scaling uper.ninih. Significant reductions in waste volumes by not using water, acidic or basic solutions, organic solvents, or nonvolatile solid abrasives as components in the cleaning process. Improved energy efficiency in post-cleaning heat exchanger operations. The ACS process consists of a spray head containing supersonic converging/diverging nozzles, a source of liquid gas; a novel, proprietary pumping system that permits pumping liquid nitrogen, liquid air, or supercritical carbon dioxide to pressures in the range of 20,000 to 60,000 psi; and various hoses, fittings, valves, and gauges. The size and number of nozzles can be varied so the system can be built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. The system also can be used to verify if a part has been adequately cleaned.

Parrish, Lewis M.↗

Theoretical considerations of soil retention

The performance of solar energy devices is adversely affected by surface soiling, and generally, the loss of performance increases with increases in the quantity of soil retained on their surfaces. To minimize performance losses caused by soiling, solar devices should not only be deployed in low soiling geographical areas, but employ surfaces or surfacing materials having low affinity for soil retention, maximum susceptibility to be naturally cleaned by wind, rain and snow, and to be readily cleanable by simple and inexpensive maintenance cleaning techniques. This article describes known and postulated mechanisms of soil retention on surfaces, and infers from these mechanisms that low soiling and easily cleanable surfaces should have low surface energy, and be hard, smooth, hydrophobic and chemically clean of sticky materials and water soluble salts.

Cuddihy, E. F.↗

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Isotopic, Chemical and Mineralogical Investigations of Extraterrestrial Materials

The principal aim of our work was to improve our understanding of the earliest evolutionary period of our solar system (i.e. the first tens of millions of years). We have studied its chronology by using short and long term chronometers (based on extinct and long lived radioactive nuclei), explored the bearing of short lived nuclei on planetary heating and differentiation, and the addition of 'exotic' nuclei to solar system matter to help constrain models of nucleosynthesis. Our basic tool is high precision Thermal Ionization Mass Spectrometry (TIMS). Over the years we have developed clean chemical separation procedures for many elements. The chemical elements most relevant to our investigations are Cr, Ni, Rb, Sr, Sm, Nd, Pb, and U, for which highly efficient measurement techniques by TIMS have been developed and have been in use in our laboratory for many years. We have explored the Mn-53 Cr-53 system (T (Mn-53) = 3.7 Ma) and have found it to be a powerful tool to obtain relative ages of meteorite formation and, more general, of early solar system processes with a time resolution of approx. 1 Ma. By measuring the Mn-Cr system in many meteorite types (chondrites, basaltic achondrites, angrites, pallasites, etc.) we have found that this condition is indeed met for most meteorite families.

Lugmair, Guenter W.↗

Corrosion Behavior of Laser-Interference Structured AA2024 Coated with a Chromate-Containing Epoxy Primer

In this study, the corrosion behavior of laser-interference treated AA2024-T3 specimens, which are coated with a primer, is presented. The surface of as-received AA2024-T3 specimens were laser-interference structured by splitting the primary beam of a Q-switched Nd:YAG pulsed nanosecond laser into two beams and focusing them to the same spot on the specimen surface. After being stored in plastic cases for up to 70 d, without any additional cleaning, the specimens were spray painted with a chromate-containing epoxy primer, CA7233, compliant to MIL-PRF-23377 Type I Class C2 specification. The corrosion behavior of laser-interference specimens was assessed against that of specimens prepared by chromated conversion coating and sulfuric acid anodizing treatments. After the ASTM B117 corrosion exposure, it was found that the laser processed specimens exhibited only few blisters. On one hand, most specimens prepared at a laser fluence of 1.78 J/cm 2 , without any additional chemical cleaning, were found to develop one very small blister after only 96 h of exposure. However, the growth of these blisters was not significant even after 1,000 h of salt spray exposure. On the other hand, only a fraction of the specimens prepared at a laser fluence of 1.24 J/cm 2 and acetone wiped right after the laser structuring were found to develop several tiny blisters after 790 h and longer exposure. Overall, it was found that the corrosion damage was minimized at a laser rastering speed of 4 mm/s, a condition for which only 33% of specimens developed very minor corrosion damage. Furthermore, the ASTM D1654 creepage ratings, which was used to evaluate the corrosion damage along the scribe lines, were found to be at least nine for all coated panels. These results indicate that the laser-interference technique with the additional acetone wiping has the potential to be further developed as a nonchemical surface preparation technique for chromate-containing epoxy primers coating systems.

36 MATERIALS SCIENCE↗