Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reflectance spectroscopy of fresh whole leaves for the estimation of chemical concentration

Remotely sensed plant-canopy data in the visible and near-IR ranges are used to establish relations between the canopy reflectance and the chemical content of the leaves. The mathematical relation is generated by means of stepwise regression based on the derivative reflectance at certain wavelengths. Fourier filtering and sample control are used to minimize instrument noise and spectral overlap respectively, and absorption features are noted that correspond to sugar and protein. The coefficients of determination between estimated and measured concentrations are at least 0.82 for such substances as starch and chlorophyll. It is recommended in the analysis of remotly sensed canopy data that the chemicals with strong spectral overlaps with the chemical of interest be accounted for in order to estimate foliar chemical concentrations accurately.

Curran, Paul J.↗

Fiber-Optic Chemiluminescent Biosensors for Monitoring Aqueous Alcohols and Other Water Quality Parameters

A "reagentless" chemiluminescent biosensor and method for the determination of hydrogen peroxide, ethanol and D-glucose in water is disclosed. An aqueous stream is basified by passing it through a solid phase base bed. Luminol is then dissolved in the basified effluent at a controlled rate. Oxidation of the luminol is catalyzed by the target chemical to produce emitted light. The intensity of the emitted light is detected as a measure of the target chemical concentration in the aqueous stream. The emitted light can be transmitted by a fiber optic bundle to a remote location from the aqueous stream for a remote reading of the target chemical concentration.

Verostko, Charles E.↗

Flame characteristics of a NASA contra swirler module

The structure of unconfined flames stabilized on a NASA contra-swirl can has been examined. The structure depends on reference velocity and fuel-air ratio, and photographic illustrations of representative examples of each flame type are shown. A highly compact flame is obtained over a narrow band of fuel-air ratios, within the total range over which flames may be stabilized, at high reference velocity (27.8 m/s). The compact structure can only be obtained with careful fuel nozzle location. Chemical concentration profiles, temperature profiles and sodium chloride seeding experiments all confirm the visual impression of compactness. A flame with 50% greater fuel throughput has a much less compact structure, which is reflected in lower maximum temperature, much more complex chemical concentration distributions and a more diffuse recirculation boundary as observed by sodium chloride seeding than in the compact flame. Each of these flames has not only an evident axial recirculation core but also a toroidal recirculation region over the bluff region between the inner and outer swirlers. In contrast, laser Doppler velocimetry measurements carried out on a flame with lower reference velocity (5.65 m/s) do not indicate the presence of a secondary recirculation region in this flame.

Thompson, D.↗

Evaluation of surface water resources from machine-processing of ERTS multispectral data

The surface water resources of a large metropolitan area, Marion County (Indianapolis), Indiana, are studied in order to assess the potential value of ERTS spectral analysis to water resources problems. The results of the research indicate that all surface water bodies over 0.5 ha were identified accurately from ERTS multispectral analysis. Five distinct classes of water were identified and correlated with parameters which included: degree of water siltiness; depth of water; presence of macro and micro biotic forms in the water; and presence of various chemical concentrations in the water. The machine processing of ERTS spectral data used alone or in conjunction with conventional sources of hydrological information can lead to the monitoring of area of surface water bodies; estimated volume of selected surface water bodies; differences in degree of silt and clay suspended in water and degree of water eutrophication related to chemical concentrations.

Mausel, P. W.↗

Preliminary results of determination of chemical element concentrations in the aerosol of Venus clouds

An X-ray radiometeric experiment is described along with the results of measurements of the elemental composition of aerosols in Venusian clouds. A preliminary analysis of the data showed that sulfur is present in the range of heights 63 to 47 km with mean content of 5.8 mg/cu m and that chlorine is present in the height range 61 t0 52 km with a mean content of 4.1 mg/cu m. The results of measurements in the range 52 to 47 km may come to an agreement if phosphorus is present in the aerosol with a mean concentration of 7.7 mg/cu m.

Andreychikov, B. M.↗

Extensive Characterization of Aerosol Optical Properties and Chemical Component Concentrations: Application of the GRASP/Component Approach to Long-term AERONET Measurements

A recently developed GRASP/Component approach (GRASP: Generalized Retrieval of Atmosphere and Surface Properties) was applied to AERONET (Aeronet Robotic Network) sun photometer measurements in this study. Unlike traditional aerosol component retrieval, this approach allows the inference of some information about aerosol composition directly from measured radiance, rather than indirectly through the inversion of optical parameters, and has been integrated into the GRASP algorithm. The newly developed GRASP/Component approach was applied to 13 AERONET sites for different aerosol types under the assumption of aerosol internal mixing rules to analyze the characteristics of aerosol components and their distribution patterns. The results indicate that the retrievals can characterize well the spatial and temporal variability of the component concentration for different aerosol types. A reasonable agreement between GRASP BC retrievals and MERRA-2 BC products is found for all different aerosol types. In addition, the relationships between aerosol component content and aerosol optical parameters such as aerosol optical depth (AOD), fine-mode fraction (FMF), absorption Ångström exponent (AAE), scattering Ångström exponent (SAE), and single scattering albedo (SSA) are also analyzed for indirect verifying the reliability of the component retrieval. It was demonstrated the GRASP/Component optical retrievals are in good agreement with AERONET standard products [e.g., correlation coefficient (R) of 0.93–1.0 for AOD, fine-mode AOD (AODF), coarse-mode AOD (AODC) and Ångström exponent (AE); R = ~ 0.8 for absorption AOD (AAOD) and SSA; RMSE (root mean square error) < 0.03 for AOD, AODF, AODC, AAOD and SSA]. Thus, it is demonstrated the GRASP/Component approach can provide aerosol optical products with comparable accuracy as the AERONET standard products from the ground-based sun photometer measurements as well as some additional important inside on aerosol composition.

Xindan Zhang↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

Comparison of dermal and inhalation routes of entry for organic chemicals

The quantitative comparison of the chemical concentration inside the body as the result of a dermal exposure versus an inhalation exposure is useful for assessing human health risks and deciding on an appropriate protective posture. In order to describe the relationship between dermal and inhalation routes of exposure, a variety of organic chemicals were evaluated. The types of chemicals chosen for the study were halogenated hydrocarbons, aromatic compounds, non-polar hydrocarbons and inhalation anesthetics. Both dermal and inhalation exposures were conducted in rats and the chemicals were in the form of vapors. Prior to the dermal exposure, rat fur was closely clipped and during the exposure rats were provided fresh breathing air through latex masks. Blood samples were taken during 4-hour exposures and analyzed for the chemical of interest. A physiologically based pharmacokinetic model was used to predict permeability constants (cm/hr) consistent with the observed blood concentrations of the chemical. The ratio of dermal exposure to inhalation exposure required to achieve the same internal dose of chemical was calculated for each test chemical. The calculated ratio in humans ranged from 18 for styrene to 1180 for isoflurane. This methodology can be used to estimate the dermal exposure required to reach the internal dose achieved by a specific inhalation exposure. Such extrapolation is important since allowable exposure standards are often set for inhalation exposures, but occupational exposures may be dermal.

Jepson, Gary W.↗

Ion-assisted tropospheric OH measurement technique

The present technique measures atmospheric OH concentrations by first titrating OH into isotopically labeled H2(exp 34)SO4 by a series of gas phase reactions in an effectively wall-less flow tube reactor on a time-scale which is short in comparison to the OH lifetime. The gas phase H2SO4 concentration is then determined by reacting it with NO3(-)(center dot)HNO3 ions in a flow tube, and subsequently measuring the resulting (HSO4(-))/(NO3(-)) ion ratio. Since the determination of H2SO4 concentration does not depend on the measurement of an absolute photon flux or chemical concentration but rather only on the relative concentration measurement of two fairly similar mass ions in conjunction with a fixed reaction time and reaction rate coefficient, no in-field calibration technique should be required. The ion-assisted OH measurement technique provides a concentration measurement about once each 10 to 20 seconds and had a detection sensitivity less than or equal to 1 x 10(exp 5) molecules/cu cm (2 standard deviations) with an integration time of 5 minutes during the past field study. Typically, the total background signal level is in the low 10(exp 6) molecule/cu cm range with the scatter in this background (or background noise in 5 minutes) in the mid 10(exp 4) molecules/cu cm range.

Eisele, Fred L.↗

A Study of the Relationship Between Anthropogenic Sulfate and Cloud Drop Nucleation

The characteristics of the cloud drop size distribution near cloud base are initially determined by the aerosol particles that serve as CCN and by the local updraft velocity. Chemical reactions of the emitted gaseous sulfur compounds due to human activities will alter, through gas-to-particle conversion, the aerosol size distribution, total number, and its chemical composition. Recently, Boucher and Rodhe and Jones et.al have each developed parameterizations relating cloud drop concentration to sulfate mass or aerosol number concentration, respectively, and used them to develop estimates of the indirect forcing by anthropogenic sulfate aerosols. THese parameterizations made use of measure relationships in continental and maritime clouds. However, these relationships are inherently noisy, yielding more than a factor of 2 variation in cloud drop concentration for a given aerosol number (or for a given sulfate mass) concentration. The large spatial and temporal variabilities in the concentration, chemical characteristics, and size distribution of aerosols have made it difficult to develop such a parameterization from data. In this paper, our focus is to develop a means for relating the predicted anthropogenic sulfate mass to cloud drop number concentration over the range of expected conditions associated with continental and marine aerosol. We start with an assumed pre-existing particle size distribution and develop an approximation of the altered distribution after addition of anthropogenic sulfate. We thereby develop a conservative estimate of the possible change in cloud drop number concentration due to anthropogenic sulfate.

Chuang, Catherine C.↗

Seasonal Patterns and Remote Spectral Estimation of Canopy Chemistry Across the Oregon Transect

We examined seasonal changes in canopy chemical concentrations and content in conifer forests growing along a climate gradient in western Oregon, as part of the Oregon Transect Ecosystem Research (OTTER) study. The chemical variables were related to seasonal patterns of growth and production. Statistical comparisons of chemical variables with data collected from two different airborne remote-sensing platforms were also carried out. Total nitrogen (N) concentrations in foliage varied significantly both seasonally and among sites; when expressed as content in the forest canopy, nitrogen varied to a much greater extent and was significantly related to aboveground net primary production (r = 0.99). Chlorophyll and free amino acid concentrations varied more strongly than did total N and may have reflected changes in physiological demands for N. Large variations in starch concentrations were measured from pre- to post-budbreak in all conifer sites. Examination of remote-sensing data from two different airborne instruments suggests the potential for remote measurement of some canopy chemicals. Multivariate analysis of high-resolution spectral data in the near infrared region indicated significant correlations between spectral signals and N concentration and canopy N content; the correlation with canopy N content was stronger and was probably associated in part with water absorption features of the forest canopy. The spectral bands that were significantly correlated with lignin concentration and content were similar to bands selected in the other laboratory and airborne studies; starch concentrations were not significantly related to spectral reflectance data. Strong relationships between the spectral position of specific reflectance features in the visible region and chlorophyll were also found.

Matson, Pamela↗

Systematic chemical variations in large 3AB iron meteorites: Clues to core crystallization

Analysis of numerous individual iron meteorites have shown that fractional crystallization of iron cores result in variations in chemical concentration of the solid core which span several orders of magnitude. The magnitude and direction of the resulting spatial gradients in the core can provide clues to the physical nature of the core crystallization process. We have analyzed suites of samples from three large 3AB irons (Cape York, 58t; Chupaderos, 24t; Morito, 10t) in order to estimate local chemical gradients. Initial results for the concentrations of Ge, Pd, Pt (Massey group), Ir, Au, As, Co, Os, and Rh (Dalhouse group), and P (Arizona group) show significant ranges among the Cape York and Chupaderos samples and marginally significant ranges among the Morito samples. Measurements of Au, Ir, Co, Ni, Cu, Ga, As, W, Re (from UCLA) and Ni and Co (Arizona group) are in progress. We find a spatial Ir gradient in Chupaderos with a magnitude similar to the one reported for Agpalilik (Cape York iron) by Esbensen et al.

Haack, H.↗

A theoretical study of a laminar diffusion flame

Theoretical models of an axisymmetric laminar diffusion flame are discussed, with an emphasis on the behavior of such flames at increasing pressures. The flame-sheet or Burke-Schumann model (in terms of Bessel functions) and various boundary layer numerical solutions are presented and their results compared with experimental data. The most promising theoretical model combines the numerical flow field solution of the Patankar-Spalding computer code with the Pratt-Wormeck chemical reaction subroutine. The flame shapes for pressures of 1, 5, 10, 20, and 50 atmospheres were computed and agree remarkably well with experimental data. There is a noticeable shape change with pressure, believed to be a result of buoyancy effects. The chemical concentration profiles do not exhibit much dependence on pressure, a reflection of the fact that only one chemical mechanism was utilized at all pressures.

Frair, K. L.↗

On the maintenance of the Marine boundary layer-free tropospheric gradient of transient tracers

A simple model of the marine boundary layer is used to arrive at a steady-state budget for trace gases in this layer. Five processes maintain the tracer balance in the layer. The first is a large-scale horizontal convergence of the tracer; the second is the pumping by clouds of the tracer out of the boundary layer into the free troposphere; the third is penetration by the tracer from the free troposphere into the marine boundary from compensating subsidence in the cloud-free air surrounding cumulus clouds; the fourth is sea surface emission or deposition of the tracer; and the fifth is in situ photochemical production or loss of the tracer within the marine boundary layer. The budget equation is used in deriving an expression for the mixing ratio difference between the two regions. A scale analysis suggests that the mixing ratio difference between the marine boundary layer and the free troposphere can be an order of magnitude smaller in disturbed weather conditions than in suppressed conditions, showing that the difference in chemical concentrations between the free troposphere and the marine boundary layer cannot be rationalized solely on the basis of chemical measurements.

Gidel, L. T.↗

Measurement of the spatial dependence of temperature and gas and soot concentrations within large open hydrocarbon fuel fires

A series of large-scale JP-4 fuel pool fire tests was conducted to refine existing mathematical models of large fires. Seven tests were conducted to make chemical concentration and temperature measurements in 7.5 and 15 meter-diameter pool fires. Measurements were made at heights of 0.7, 1.4, 2.9, 5.7, 11.4, and 21.3 meters above the fires. Temperatures were measured at up to 50 locations each second during the fires. Chemistry samples were taken at up to 23 locations within the fires and analyzed for combustion chemistry and soot concentration. Temperature and combustion chemistry profiles obtained during two 7.5 meter-diameter and two 15 meter-diameter fires are included.

Johnson, H. T.↗

Trace Contaminant Testing with the Orion Atmosphere Revitalization Technology

Every spacecraft atmosphere contains trace contaminants resulting from offgassing by cabin materials and human passengers. An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). Part of the risk mitigation effort for this new technology is the study of how atmospheric trace contaminants will affect and be affected by the technology. One particular area of concern is ammonia, which, in addition to the normal spacecraft sources, can also be off-gassed by the amine-based sorbent. In the first half of 2009, tests were performed with typical cabin atmosphere levels of five of the most common trace gases, most of which had not yet been tested with this technology. A subscale sample of the sorbent was exposed to each of the chemicals mixed into a stream of moist, CO2-laden air, and the CO2 adsorption capacity of the sorbent was compared before and after the exposure. After these typical-concentration chemicals were proven to have negligible effect on the subscale sample, tests proceeded on a full-scale test article in a sealed chamber with a suite of eleven contaminants. To isolate the effects of various test rig components, several extended-duration tests were run: without injection or scrubbing, with injection and without scrubbing, with injection and scrubbing by both the test article and dedicated trace contaminant filters, and with injection and scrubbing by only the test article. The high-level results of both the subscale and full-scale tests are examined in this paper.

Button, Amy Lin↗

Trace Contaminant Testing with the Orion Atmosphere Revitalization Technology

Every spacecraft atmosphere contains trace contaminants resulting from offgassing by cabin materials and human passengers. An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). Part of the risk mitigation effort for this new technology is the study of how atmospheric trace contaminants will affect and be affected by the technology. One particular area of concern is ammonia, which, in addition to the normal spacecraft sources, can also be offgassed by the amine-based sorbent. In the spring of 2009, tests were performed at Johnson Space Center (JSC) with typical cabin atmosphere levels of five of the most common trace gases, most of which had not yet been tested with this technology. A subscale sample of the sorbent was exposed to each of the chemicals mixed into a stream of moist, CO2-laden air, and the CO2 adsorption capacity of the sorbent was compared before and after the exposure. After these typical-concentration chemicals were proven to have negligible effect on the subscale sample, tests proceeded on a full-scale test article in a sealed chamber with a suite of eleven contaminants. To isolate the effects of various test rig components, several extended-duration tests were run: without injection or scrubbing, with injection and without scrubbing, with injection of both contaminants and metabolic CO2 and water vapor loads and scrubbing by both the test article and dedicated trace contaminant filters, and with the same injections and scrubbing by only the test article. The high-level results of both the subscale and full-scale tests are examined in this paper.

Button, Amy B.↗