Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Molecules for Fluorescence Detection of Specific Chemicals

A family of fluorescent dye molecules has been developed for use in on-off fluorescence detection of specific chemicals. By themselves, these molecules do not fluoresce. However, when exposed to certain chemical analytes in liquid or vapor forms, they do fluoresce (see figure). These compounds are amenable to fixation on or in a variety of substrates for use in fluorescence-based detection devices: they can be chemically modified to anchor them to porous or non-porous solid supports or can be incorporated into polymer films. Potential applications for these compounds include detection of chemical warfare agents, sensing of acidity or alkalinity, and fluorescent tagging of proteins in pharmaceutical research and development. These molecules could also be exploited for use as two-photon materials for photodynamic therapy in the treatment of certain cancers and other diseases. A molecule in this family consists of a fluorescent core (such as an anthracene or pyrene) attached to two end groups that, when the dye is excited by absorption of light, transfer an electron to the core, thereby quenching the fluorescence. The end groups can be engineered so that they react chemically with certain analytes. Upon reaction, electrons on the end groups are no longer available for transfer to the core and, consequently, the fluorescence from the core is no longer quenched. The chemoselectivity of these molecules can be changed by changing the end groups. For example, aniline end groups afford a capability for sensing acids or acid halides (including those contained in chemical warfare agents). Pyridine or bipyridyl end groups would enable sensing of metal ions. Other chemicals that can be selectively detected through suitable choice of end groups include glucose and proteins. Moreover, the fluorescent cores can be changed to alter light-absorption and -emission characteristics: anthracene cores fluoresce at wavelengths around 500 nm, whereas perylene cores absorb and emit at wavelengths of about 600 nm.

Fedor, Steve↗

Space Shuttle solid rocket motor exposure monitoring

During the processing of the Space Shuttle Solid Rocket Booster (SRB), segments at the Kennedy Space Center, an odor was detected around the solid propellant. An Industrial Hygiene survey was conducted to determine the chemical identity of the SRB offgassing constituents. Air samples were collected inside a forward SRB segment and analyzed to determine chemical composition. Specific chemical analysis for suspected offgassing constituents of the propellant indicated ammonia to be present. A gas chromatograph mass spectroscopy (GC/MS) analysis of the air samples detected numerous high molecular weight hydrocarbons.

Brown, S. W.↗

Investigating Titan's Atmospheric Chemistry at Low Temperature in Support of the NASA Cassini Mission

Titan's atmosphere, composed mainly of N2 and CH4, is the siege of a complex chemistry induced by solar UV radiation and electron bombardment from Saturn's magnetosphere. This organic chemistry occurs at temperatures lower than 200 K and leads to the production of heavy molecules and subsequently solid aerosols that form the orange haze surrounding Titan. The Titan Haze Simulation (THS) experiment has been developed on the COSMIC simulation chamber at NASA Ames in order to study the different steps of Titan's atmospheric chemistry at low temperature and to provide laboratory data in support for Cassini data analysis. The chemistry is simulated by plasma in the stream of a supersonic expansion. With this unique design, the gas mixture is adiabatically cooled to Titan-like temperature (approx. 150 K) before inducing the chemistry by plasma discharge. Different gas mixtures containing N2, CH4, and the first products of the N2,-CH4 chemistry (C2H2, C2H4, C6H6...) but also heavier molecules such as PAHs or nitrogen containing PAHs can be injected. Both the gas phase and solid phase products resulting from the plasma-induced chemistry can be monitored and analyzed. Here we present the results of recent gas phase and solid phase studies that highlight the chemical growth evolution when injecting heavier hydrocarbon trace elements in the initial N2-CH4 mixture. Due to the short residence time of the gas in the plasma discharge, only the first steps of the chemistry have time to occur in a N2-CH4 discharge. However by adding acetylene and benzene to the initial N2-CH4 mixture, we can study the intermediate steps of Titan's atmospheric chemistry as well as specific chemical pathways. These results show the uniqueness of the THS experiment to help understand the first and intermediate steps of Titan fs atmospheric chemistry as well as specific chemical pathways leading to Titan fs haze formation.

Sciamma-O'Brien, Ella↗

Interstellar Processes Leading to Molecular Deuterium Enrichment and Their Detection

Large deuterium (D) enrichments in meteoritic materials indicate that interstellar organic materials survived incorporation into parent bodies within the forming Solar System. These enrichments are likelier due to one or more of four distinct astrochemical processes. These are (1) low temperature gas phase ion-molecule reactions; (2) low temperature gas-grain reactions; (3) gas phase unimolecular photodissociation, and (4) ultraviolet photolysis in D-enriched ice mantles. Each of these processes should be associated with molecular carriers having, distinct regiochemical signatures (D placement on the product molecules, correlation with specific chemical functionalities, etc.). These processes are reviewed and specific spectroscopic signatures for the detection of these processes in space are identified and described.

Sandford, Scott A.↗

Nanowire Electron Scattering Spectroscopy

Nanowire electron scattering spectroscopy (NESS) has been proposed as the basis of a class of ultra-small, ultralow-power sensors that could be used to detect and identify chemical compounds present in extremely small quantities. State-of-the-art nanowire chemical sensors have already been demonstrated to be capable of detecting a variety of compounds in femtomolar quantities. However, to date, chemically specific sensing of molecules using these sensors has required the use of chemically functionalized nanowires with receptors tailored to individual molecules of interest. While potentially effective, this functionalization requires labor-intensive treatment of many nanowires to sense a broad spectrum of molecules. In contrast, NESS would eliminate the need for chemical functionalization of nanowires and would enable the use of the same sensor to detect and identify multiple compounds. NESS is analogous to Raman spectroscopy, the main difference being that in NESS, one would utilize inelastic scattering of electrons instead of photons to determine molecular vibrational energy levels. More specifically, in NESS, one would exploit inelastic scattering of electrons by low-lying vibrational quantum states of molecules attached to a nanowire or nanotube.

Hunt, Brian↗

Progress towards computer simulation of NiH2 battery performance over life

The long-term performance of rechargeable battery cells has traditionally been verified through life-testing, a procedure that generally requires significant commitments of funding and test resources. In the situation of nickel hydrogen battery cells, which have the capability of providing extremely long cycle life, the time and cost required to conduct even accelerated testing has become a serious impediment to transitioning technology improvements into spacecraft applications. The utilization of computer simulations to indicate the changes in performance to be expected in response to design or operating changes in nickel hydrogen cells is therefore a particularly attractive tool in advanced battery development, as well as for verifying performance in different applications. Computer-based simulations of the long-term performance of rechargeable battery cells have typically had very limited success in the past. There are a number of reasons for the lack in progress in this area. First, and probably most important, all battery cells are relatively complex electrochemical systems, in which performance is dictated by a large number of interacting physical and chemical processes. While the complexity alone is a significant part of the problem, in many instances the fundamental chemical and physical processes underlying long-term degradation and its effects on performance have not even been understood. Second, while specific chemical and physical changes within cell components have been associated with degradation, there has been no generalized simulation architecture that enables the chemical and physical structure (and changes therein) to be translated into cell performance. For the nickel hydrogen battery cell, our knowledge of the underlying reactions that control the performance of this cell has progressed to where it clearly is possible to model them. The recent development of a relative generalized cell modelling approach provides the framework for translating the chemical and physical structure of the components inside a cell into its performance characteristics over its entire cycle life. This report describes our approach to this task in terms of defining those processes deemed critical in controlling performance over life, and the model architecture required to translate the fundamental cell processes into performance profiles.

Zimmerman, Albert H.↗

Determination of the Complex Refractive Indices of Aerosol Analogs Formed at Low Temperatures with the NASA Ames Optical Constants Facility (OCF)

The NASA Ames COsmic SImulation Chamber (COSmIC) [1] is a unique experimental facility that allows: 1) cooling a gas mixture to low temperature (150 K) in a jet expansion before inducing chemistry by plasma; and 2) controlling the extent of the chemical reactions by employing a pulsed plasma discharge. This enables the study of the early stages of aerosol production, as well as specific chemical pathways in planetary environments (e.g. Titan’s and Pluto’s atmospheres). Both the gas and solid products can be studied. For a decade COSmIC has been used to simulate Titan’s atmospheric chemistry at low, Titan-like temperature [2]. New developments on the COSmIC facility are investigating formation of aerosols in tenuous, or transitory, atmospheres of other icy bodies [3-5], as well as cool exoplanets atmospheres having a hydrocarbon component, that results in formation of hazes and/or surface deposits of refractory materials. The new Ames Optical Constants Facility enables determination of the aerosol analogs' complex refractive indices, n and k, from 0.59 to 200 μm [2]. Here we report efforts of determining n and k from ex-situ transmission measurements of solid samples produced from binary N-CH and Ar-CH, and tertiary N-CH-CH and Ar-CH-CHgas mixtures in COSmIC, and deposited onto various substrates. A computational technique [6] that addresses interference fringes observed in the laboratory transmission data, particularly at wavelengths < 3 μm, has been implemented and applied to determine n and k for the samples. At visible and near-infrared wavelengths(0.4-1.6 μm) the deposit thickness, and its variation, as well as n and k were determined by a commercial entity. These data provide the ability to compare results, from independent methods, in the region of overlap between the two approaches.

Ella M Sciamma-O'Brien↗

Viking and Mars Rover exobiology

Other than Earth, Mars is the planet generating the greatest interest among those researching and contemplating the origin and distribution of life throughout the universe. The similarity of the early environments of Earth and Mars, and the biological evolution on early Earth provides the motivation to seriously consider the possibility of a primordial Martian biosphere. In 1975 the Viking project launched two unmanned spacecraft to Mars with the intent of finding evidence of the existence of present or past life on this planet. Three Viking Biology experiments were employed: the Labeled Release experiment, the Gas Exchange Experiment, and the Pyrolytic Release experiment. Each of these three experiments tested for microbial existence and utilization of a substrate by examining the gases evolved from specific chemical reactions. Although the results of these experiments were inconclusive, they inferred that there are no traces of extant life on Mars. However, the experiments did not specifically look for indication of extinct life. Therefore, most of the exobiologic strategies and experiments suggested for the Mars Rover Sample Return Mission involve searching for signature of extinct life. The most significant biological signatures and chemical traces to detect include: isotopic and chemical signatures of metabolic activity, anomalous concentrations of certain metals, trace and microfossils, organically preserved materials, carbonates, nitrates, and evaporites.

Schwartz, D. E.↗

Aromatic proteinaceous surfactants stabilize long-lived gas microbubbles from natural sources

Three different types of protein-specific chemical tests were performed on long-lived gas microbubbles derived from aqueous solutions of agarose powder and from filtered aqueous extracts of Hawaiian forest soil. The separate protein-specific tests involved use of either 0.3% (w/v) ninhydrin, 100 microM methylene blue dye, or 0.7-1.0 M 2-hydroxy-5-nitrobenzyl bromide. The chemical test results obtained with each of the two natural substances, i.e., agarose powder and Hawaiian forest soil, were very similar and indicate that the biological surfactants which surround and stabilize long-lived gas microbubbles are proteinaceous compounds that contain, and whose surface activity depends upon, aromatic amino acid residues, particularly tryptophan.

Darrigo, J. S.↗

Parallelization and visual analysis of multidimensional fields: Application to ozone production, destruction, and transport in three dimensions

Atmospheric modeling is a grand challenge problem for several reasons, including its inordinate computational requirements and its generation of large amounts of data concurrent with its use of very large data sets derived from measurement instruments like satellites. In addition, atmospheric models are typically run several times, on new data sets or to reprocess existing data sets, to investigate or reinvestigate specific chemical or physical processes occurring in the earth's atmosphere, to understand model fidelity with respect to observational data, or simply to experiment with specific model parameters or components.

Schwan, Karsten↗

Chemical Analysis and Water Recovery Testing of Shuttle-Mir Humidity Condensate

Humidity condensate collected and processed in-flight is an important component of a space station drinking water supply. Water recovery systems in general are designed to handle finite concentrations of specific chemical components. Previous analyses of condensate derived from spacecraft and ground sources showed considerable variation in composition. Consequently, an investigation was conducted to collect condensate on the Shuttle while the vehicle was docked to Mir, and return the condensate to Earth for testing. This scenario emulates an early ISS configuration during a Shuttle docking, because the atmospheres intermix during docking and the condensate composition should reflect that. During the STS-89 and STS-91 flights, a total volume of 50 liters of condensate was collected and returned. Inorganic and organic chemical analyses were performed on aliquots of the fluid. Tests using the actual condensate were then conducted with scaled-down elements of the Russian condensate recovery system to determine the quality of water produced. The composition and test results are described, and implications for ISS are discussed.

Mudgett, Paul D.↗

Microfluidic Extraction of Biomarkers using Water as Solvent

A proposed device, denoted a miniature microfluidic biomarker extractor (mu-EX), would extract trace amounts of chemicals of interest from samples, such as soils and rocks. Traditionally, such extractions are performed on a large scale with hazardous organic solvents; each solvent capable of dissolving only those molecules lying within narrow ranges of specific chemical and physical characteristics that notably include volatility, electric charge, and polarity. In contrast, in the mu-EX, extractions could be performed by use of small amounts (typically between 0.1 and 100 L) of water as a universal solvent. As a rule of thumb, in order to enable solvation and extraction of molecules, it is necessary to use solvents that have polarity sufficiently close to the polarity of the target molecules. The mu-EX would make selection of specific organic solvents unnecessary, because mu-EX would exploit a unique property of liquid water: the possibility of tuning its polarity to match the polarity of organic solvents appropriate for extraction of molecules of interest. The change of the permittivity of water would be achieved by exploiting interactions between the translational states of water molecules and an imposed electromagnetic field in the frequency range of 300 to 600 GHz. On a molecular level, these interactions would result in disruption of the three-dimensional hydrogen-bonding network among liquid-water molecules and subsequent solvation and hydrolysis of target molecules. The mu-EX is expected to be an efficient means of hydrolyzing chemical bonds in complex macromolecules as well and, thus, enabling analysis of the building blocks of these complex chemical systems. The mu-EX device would include a microfluidic channel, part of which would lie within a waveguide coupled to an electronically tuned source of broad-band electromagnetic radiation in the frequency range from 300 to 600 GHz (see figure). The part of the microfluidic channel lying in the waveguide would constitute an interaction volume. The dimensions of the interaction volume would be chosen in accordance with the anticipated amount of solid sample material needed to ensure extraction of sufficient amount of target molecules for detection and analysis. By means that were not specified at the time of reporting the information for this article, the solid sample material would be placed in the interaction volume. Then the electromagnetic field would be imposed within the waveguide and water would be pumped through the interaction volume to effect the extraction.

Amashukeli, Xenia↗

Improved inhalation technology for setting safe exposure levels for workplace chemicals

Threshold Limit Values recommended as allowable air concentrations of a chemical in the workplace are often based upon a no-observable-effect-level (NOEL) determined by experimental inhalation studies using rodents. A 'safe level' for human exposure must then be estimated by the use of generalized safety factors in attempts to extrapolate from experimental rodents to man. The recent development of chemical-specific physiologically-based toxicokinetics makes use of measured physiological, biochemical, and metabolic parameters to construct a validated model that is able to 'scale-up' rodent response data to predict the behavior of the chemical in man. This procedure is made possible by recent advances in personal computer software and the emergence of appropriate biological data, and provides an analytical tool for much more reliable risk evaluation and airborne chemical exposure level setting for humans.

Stuart, Bruce O.↗

The Effect of Composition on Microstructure and Properties for Additively Manufactured Superalloy 718

Additive manufacturing (AM) represents an exciting new approach towards producing metallic aerospace components. The ability to make complex geometries that were impossible to create using conventional manufacturing methods has sparked interest from the aerospace community, including NASA. The use of AM components for crucial and human rated space missions necessitates a full characterization of the differences between AM and more conventional wrought and cast processes. For this study, sixteen different commercially available superalloy 718 powder feedstocks were obtained, built using laser powder bed fusion(L-PBF), and microstructurally and mechanically analyzed. These measurements revealed a wide range of build qualities and microstructures despite all powder lots falling within the 718chemical specification and being processed using the same prescribed build and heat treatment parameters. Statistical analysis found a strong correlation of the amount of carbon in the powder with the final grain size and strength of the heat-treated 718 part. Ultimately, this study highlights the need of a refined superalloy 718 chemical specification for powder lots to be used in AM.

Timothy M Smith↗

Spacecraft Water Exposure Guidelines For Selected Contaminants

Construction of the International Space Station (ISS)a multinational effort began in 1999. In its present configuration, the ISS is expected to carry a crew of three to six astronauts for up to 180 days (d). Because the space station is a closed and complex environment, some contamination of its internal atmosphere and water system is unavoidable. Several hundred chemical contaminants are likely to be found in the closed-loop atmosphere and recycled water of the ISS. To protect space crews from contaminants in potable and hygiene water, the National Aeronautics and Space Administration (NASA) requested that the National Research Council (NRC) provide guidance on how to develop water exposure guidelines and subsequently review NASA's development of the exposure guidelines for specific chemicals.

Water↗

Quantum chemical study of methane oxidation species

The research funded by this project has focused on quantum chemical investigations of molecular species thought to be important in the chemistry of the earth's upper and lower atmospheres. The body of this report contains brief discussions of the results of the several phases of this investigation. In many instances these results have been presented at scientific meetings and/or published in refereed journals. Those bibliographic references are given. In addition to the study of specific chemical systems, there were several phases during the course of this investigation where much of the effort went into the development and modification of computer codes necessary to carry out these calculations on the wide range of computer equipment used during this study. This type of code maintenance and development work did not generally result in publications and presentations, but a brief review is given.

Jackels, Charles F.↗

Precision Subsampling System for Mars Surface Missions

The ability to analyze heterogeneous rock samples at fine spatial scales would represent a powerful addition to our planetary in situ analytical toolbox. This is particularly true for Mars, where the signatures of past environments and, potentially, habitability are preserved in chemical and morphological variations across sedimentary layers and among mineral pr.ases in a given rock specimen. On Earth, microbial life often associates with surfaces at the interface of chemical nutrients, and ultimately retains sub-millimeter to millimeter-scale layer confinement in fossilization. On Mars, and possibly other bodies, trace chemical markers (elemental, organic/molecular, isotopic, chiral, etc.) and fine-scale morphological markers (e.g., micro-fossils) may he too subtle, degraded, or ambiguous to be detected, using miniaturized instrumentation, without some concentration or isolation. This is because (i) instrument sensitivity may not be high enough to detect trace markers in bulk averages; and (ii) instrument s~lectiviry may not be sufficient to distinguish such markers from interfering/counteracting signals from the bulk. Moreover from a fundamental chemostratigraphic perspective there would be a great benefit to assessing specific chemical and stable isotopic gradients, over millimeter-to-centimeter scales and beyond, with higher precision than currently possible in situ. We have developed a precision subsampling system (PSS) that addresses this need while remaining relatively flexible to a variety of instruments that may take advantage of the capability on future missions. The PSS is relevant to a number of possible lander/rover missions, especially Mars Sample Return. Our specific PSS prototype is undergoing testing under Mars ambient conditions, on a variety of natural analog rocks and rock drill cores, using a set of complementary flight-compatible measurement techniques. The system is available for testing with other contact instruments that may benefit from precision sampling.

Mahaffy, P. R.↗