Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock ensemble”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A review of reduced Kalman filters for clock ensembles

This paper reviews the author’s previous work on free-running timescales based on Kalman filters that act upon clock comparisons. The natural Kalman clock ensemble algorithm tends to optimize long-term timescale stability at the expense of short-term stability. By subjecting each postmeasurement error covariance matrix to a non-transparent reduction operation, one obtains corrected clocks with improved short-term stability and little sacrifice of long-term stability. A new result on covariance matrix reduction is also stated.

Greenhall, Charles A.↗

Reduced Kalman Filters for Clock Ensembles

This paper summarizes the author's work ontimescales based on Kalman filters that act upon the clock comparisons. The natural Kalman timescale algorithm tends to optimize long-term timescale stability at the expense of short-term stability. By subjecting each post-measurement error covariance matrix to a non-transparent reduction operation, one obtains corrected clocks with improved short-term stability and little sacrifice of long-term stability.

Kalman filter↗

Application of Millisecond Pulsar Timing to the Long-Term Stability of Clock Ensembles

We review the application of millisecond pulsars to define a precise long-term standard and positional reference system in a nearly inertial reference frame. We quantify the current timing precision of the best millisecond pulsars and define the required precise time and time interval (PTTI) accuracy and stability to enable time transfer via pulsars. Pulsars may prove useful as independent standards to examine decade-long timing stability and provide an independent natural system within which to calibrate any new, perhaps vastly improved atomic time scale. Since pulsar stability appears to be related to the lifetime of the pulsar, the new millisecond pulsar J173+0747 is projected to have a 100-day accuracy equivalent to a single HP5071 cesium standard. Over the last five years, dozens of new millisecond pulsars have been discovered. A few of the new millisecond pulsars may have even better timing properties.

Foster, Roger S.↗

Estimating the instability of a composite clock

A composite clock created from a local clock ensemble is known by its time offsets from the ensemble clocks. By a geometrical argument, estimate for the instability of the composite clock are calculated from the instabilities of the ensemble clocks, individually and against the composite clock. The method is illustrated by examples using simulated and real ensembles.

timescale↗

Addition of random run FM noise to the KPW time scale algorithm

The KPW (Kalman plus weights) time scale algorithm uses a Kalman filter to provide frequency and drift information to a basic time scale equation. This paper extends the algorithm to three-state clocks nd gives results for a simulated eight-clock ensemble.

time scale clock ensemble clock noise↗

Using GPS and VLBI technology to maintain 14 digit synchronization

To facilitate the navigation of spacecraft to the outer planets, Jupiter and beyond, the JPL-NASA Deep Space Network (DSN) has implemented three ensembles of atomic clocks at widely separated locations. These clocks must be maintained, synchronized, to with a few parts in 10 to the 13th power of each other and, the entire group must be maintained, to a lesser degree, in synchronism with Coordinated Universal Time (UTC)NBS/USNO. Over the last 1 1/2 years the DSN has been using Global Positioning Satellites (GPS) and Very Long Baseline Interferometry (VLBI) technology to perform these critical Frequency and Time (F&T) synchronization tasks. A year of F&T synchronization data collected from the intercomparison of 3 sets of cesium and hydrogen maser driven clock ensembles through the use of GPS and VLBI techniques are covered. Also covered, are some of the problems met and limitations of these two techniques at their present level of technology.

Ward, S. C.↗

Appendix A: The Impact of the HP 5071A on International Atomic Time

The international clock ensemble, which contributes to the generation of International Atomic Time (TAI and UTC) has improved dramatically over the last few years. The main change has been the introduction of a significant number of HP 5071A clocks. Of the 313 clocks contributing to TAI/UTC during 1994, 94 of these were HP 5071As. The environmental insensitivity of the HP 5071A clocks is more than an order of magnitude better than that of previously contributing clocks. This environmental insensitivity translates to outstanding long-term stability - with a typical flicker floor of a few x10(sup -15). in addition, there are now several hydrogen masers with cavity tuning contributing to TAI/UTC. These not only have outstanding short-term stability, but comparatively low frequency drifts and excellent intermediate-type frequency stability. By analyzing data available from the international ensemble, we have obtained two important results. First the frequency stability obtainable with an optimum algorithm is about 10(sup -15) for both the intermediate and long-term regions. It could be as good in the short-term (if time transfer measurement instabilities were reduced sufficiently. Second, with cooperation, this performance can be made available on an international basis in near real time. The recent enhancements in the contributing clocks are already providing a significant improvement in the accuracy with which UTC is made available to the world from several of the national timing centers, such as the National Institute for Standards and Technology (NIST) and the US Naval Observatory (USNO).

Allan, David W.↗

An optimal modification of a Kalman filter for time scales

The Kalman filter in question, which was implemented in the time scale algorithm TA(NIST), produces time scales with poor short-term stability. A simple modification of the error covariance matrix allows the filter to produce time scales with good stability at all averaging times, as verified by simulations of clock ensembles.

time scale Kalman filter↗

Kalman plus weights: a time scale algorithm

KPW is a time scale algorithm that combines Kalman filtering with the basic time scale equation (BTSE). A single Kalman filter that estimates all clocks simultaneously is used to generate the BTSE frequency estimates, while the BTSE weights are inversely proportional to the white FM variances of the clocks. Results from simulated clock ensembles are compared to previous simulation results from other algorithms.

time time scales stability Kalman filtering↗

An algorithm for the Italian atomic time scale

During the past twenty years, the time scale at the IEN has been realized by a commercial cesium clock, selected from an ensemble of five, whose rate has been continuously steered towards UTC to maintain a long term agreement within 3 x 10(exp -13). A time scale algorithm, suitable for a small clock ensemble and capable of improving the medium and long term stability of the IEN time scale, has been recently designed taking care of reducing the effects of the seasonal variations and the sudden frequency anomalies of the single cesium clocks. The new time scale, TA(IEN), is obtained as a weighted average of the clock ensemble computed once a day from the time comparisons between the local reference UTC(IEN) and the single clocks. It is foreseen to include in the computation also ten cesium clocks maintained in other Italian laboratories to further improve its reliability and its long term stability. To implement this algorithm, a personal computer program in Quick Basic has been prepared and it has been tested at the IEN time and frequency laboratory. Results obtained using this algorithm on the real clocks data relative to a period of about two years are presented.

Cordara, F.↗

Timescale algorithms combining cesium clocks and hydrogen masers

The United States Naval Observatory (USNO) atomic timescale, formerly based on an ensemble of cesium clocks, is now produced by an ensemble of cesium clocks and hydrogen masers. In order to optimize stability and reliability, equal clock weighting has been replaced by a procedure reflecting the relative, time-varying noise characteristics of the two different types of clocks. Correlation of frequency drift is required, and residual drift is avoided by the eventual complete deweighting of the masers.

Lee A. Breakiron↗

Advances in time-scale algorithms

The term clock is usually used to refer to a device that counts a nearly periodic signal. A group of clocks, called an ensemble, is often used for time keeping in mission critical applications that cannot tolerate loss of time due to the failure of a single clock. The time generated by the ensemble of clocks is called a time scale. The question arises how to combine the times of the individual clocks to form the time scale. One might naively be tempted to suggest the expedient of averaging the times of the individual clocks, but a simple thought experiment demonstrates the inadequacy of this approach. Suppose a time scale is composed of two noiseless clocks having equal and opposite frequencies. The mean time scale has zero frequency. However if either clock fails, the time-scale frequency immediately changes to the frequency of the remaining clock. This performance is generally unacceptable and simple mean time scales are not used. First, previous time-scale developments are reviewed and then some new methods that result in enhanced performance are presented. The historical perspective is based upon several time scales: the AT1 and TA time scales of the National Institute of Standards and Technology (NIST), the A.1(MEAN) time scale of the US Naval observatory (USNO), the TAI time scale of the Bureau International des Poids et Measures (BIPM), and the KAS-1 time scale of the Naval Research laboratory (NRL). The new method was incorporated in the KAS-2 time scale recently developed by Timing Solutions Corporation. The goal is to present time-scale concepts in a nonmathematical form with as few equations as possible. Many other papers and texts discuss the details of the optimal estimation techniques that may be used to implement these concepts.

Stein, S. R.↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

Free Space Ramsey Spectroscopy in Rubidium with Noise below the Quantum Projection Limit

In this work, we demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 87 Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 μ m radius and falls roughly 300 μm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2) × 10 –12 , 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗