Search NASASearch

SEARCH · Search NASA

Results for “clocks oscillators linear ion trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.

Progress Report on the Improved Linear Ion Trap Physics Package

This article describes the first operational results from the extended linear ion trap frequency standard now being developed at JPL. This new design separates the state selection/interrogation region from the more critical microwave resonance region where the multiplied local oscillator (LO) signal is compared to the stable atomic transition. Hg+ ions have been trapped, shuttled back and forth between the resonance and state selection traps. In addition, microwave transitions between the Hg+ clock levels have been driven in the resonance trap and detected in the state selection trap.

Linear Ion Trap

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric

Ultra-stable Hg(+) trapped ion frequency standard

We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.

Prestage, J. D.

A high-performance Hg(+) trapped ion frequency standard

A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.

Prestage, J. D.

Modifying Operating Cycles to Increase Stability in a LITS

The short-term instability in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced by modifying two cycles involved in its operation: (1) the bimodal (bright/dim) cycle of a plasma discharge lamp used for state preparation and detection and (2) a microwave-interrogation cycle. The purpose and effect of the modifications is to enable an increase in the microwave- interrogation cycle time, motivated by the general principle that the short-term uncertainty or instability decreases with increasing microwave-interrogation time. Stated from a slightly different perspective, the effect of modifications is to enable the averaged LITS readings to settle to their longterm stability over a shorter total observation time. The basic principles of a LITS were discussed in several NASA Tech Briefs articles. Here are recapitulated only those items of background information necessary to place the present modifications in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of a ground-state hyperfine transition of Hg-199(+) ions. In a LITS of the type to which the modifications apply, the comparison involves a combination of optical and micro wave excitation and interrogation of the ions in two collinear ion traps: a quadrupole trap wherein the optical excitation used for state preparation and detection takes place, and a multipole (e.g., 12-pole) trap wherein the microwave interrogation of the clock transition takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. This concludes the background information.

Burt, Eric