Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

code compliance↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

Energy Codes, code compliance↗

Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% to 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of 2006 IECC and 2009 IECC Commercial Energy Code Requirements for Kansas City, MO

This report summarizes code requirements and energy savings of commercial buildings in climate zone 4 built to the 2009 IECC when compared to the 2006 IECC. In general, the 2009 IECC has higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment (HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted). The energy analysis results show that residential and nonresidential commercial buildings meeting the 2009 IECC requirements save between 6.1% and 9.0% site energy, and between 6.4% and 7.7% energy cost when compared to 2006 IECC. Analysis also shows that semiheated buildings have energy and cost savings of 3.9% and 5.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OM Code Requirements For MOVs -- OMN-1 and Appendix III

The purpose or scope of the ASME OM Code is to establish the requirements for pre-service and in-service testing of nuclear power plant components to assess their operational readiness. For MOVs this includes those that perform a specific function in shutting down a reactor to the safe shutdown condition, maintaining the safe shutdown condition, and mitigating the consequences of an accident. This paper will present a brief history of industry and regulatory activities related to MOVs and the development of Code requirements to address weaknesses in earlier versions of the OM Code. The paper will discuss the MOV requirements contained in the 2009 version of ASME OM Code, specifically Mandatory Appendix III and OMN-1, Revision 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metallic Fuel Performance Code Requirements for the Versatile Test Reactor Project

Metallic nuclear fuels have been proposed for use in several emerging nuclear reactor designs, and a number of codes have been developed to model these fuels and assess their performance. Qualification of these metallic nuclear fuels will ultimately require monitored irradiation of lead test assemblies, but the use of fuel performance codes can reduce the uncertainty associated with these efforts by quantifying uncertainties and estimating margins to failure ahead of time. In this work, metallic fuel performance code requirements are defined for the Versatile Test Reactor (VTR) project using input from the Experimental Breeder Reactor II functional requirements, operational requirements, and design criteria. This work focuses on the thermomechanical responses and irradiation behaviors of metallic fuel elements that are representative of the proposed VTR driver fuel design concepts. As such, many of the code requirements and physics/modeling discussions in this work are expected to be broadly applicable to metallic fuel applications outside of the VTR project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Utah

The 2009 International Energy Conservation Code (IECC) contains several major improvements in energy efficiency over the current Utah code, the 2006 IECC. The most notable changes are improved duct sealing and efficient lighting requirements. A limited analysis of these changes resulted in estimated savings of $168 to $188 for an average new house in Utah at recent fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Mesa, Arizona

The 2009 International Energy Conservation Code (IECC) contains several major improvements in energy efficiency over the 2006 IECC and the 2003 IECC. The notable changes are: (1) Improved duct sealing verified by testing the duct system; (2) Increased duct insulation; (3) Improvement of window U-factors from 0.40 to 0.35; and (4) Efficient lighting requirements. An analysis of these changes resulted in estimated annual energy cost savings of $145 a year for an average new house compared to the 2003 IECC. This energy cost saving decreases to $125 a year for the 2009 IECC compared to the 2006 IECC. Construction cost increases (per home) for complying with the 2009 IECC are estimated at $1256 relative to the 2003 IECC and $800 for 2006 IECC. Home owners will experience an annual cost savings of about $80 a year by complying with the 2009 IECC because reduction to energy bills will more than compensate for increased mortgage payments and other costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri

The 2009 International Energy Conservation Code (IECC) contains several major improvements in energy efficiency over the 2006 IECC. The notable changes are: (1) Improved duct sealing verified by testing the duct system; (2) Increased duct insulation; (3) Improvement of window U-factors from 0.40 to 0.35; and (4) Efficient lighting requirements. An analysis of these changes resulted in estimated annual energy cost savings of about $145 a year for an average new house. Construction cost increases are estimated at $655. Home owners will experience an annual cost savings of close to $100 a year because reduction to energy bills will more than compensate for increased mortgage payments and other costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification and Analysis of Critical Gaps in Nuclear Fuel Cycle Codes Required by the SINEMA Program

The current state of the art in nuclear fuel cycle (NFC) modeling is an eclectic mixture of codes with various levels of applicability, flexibility, and availability. In support of the advanced fuel cycle systems analyses, especially those by the Advanced Fuel Cycle Initiative (AFCI), Unviery of Cincinnati in collaboration with Idaho State University carried out a detailed review of the existing codes describing various aspects of the nuclear fuel cycle and identified the research and development needs required for a comprehensive model of the global nuclear energy infrastructure and the associated nuclear fuel cycles. Relevant information obtained on the NFC codes was compiled into a relational database that allows easy access to various codes' properties. Additionally, the research analyzed the gaps in the NFC computer codes with respect to their potential integration into programs that perform comprehensive NFC analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview of Nuclear vs. Non-Nuclear Design Code Requirements for a Candidate Steam Supply System for Commercial Applications

The objective is to identify (mostly for industrial end-users) the difference between a Section III nuclear steam generator (classified as Structures, Systems and Components (SSC)) and a Section VIII steam generator in the same general conditions, but used in a conventional application. Specifically, applicable temperature and pressure ranges and a more quantitative description of how materials change, design margins change and required design rigor changes are of interest. This overview focuses on the steam generator pressure boundary but the downstream piping will also be considered. Within the designations of Section III and Section VIII there are subcategories with their specific regions of applicability. Each of these subcategories has evolved their own unique features with respect to design rules and their implementation. A general overview of the various design codes will be provided in sufficient detail to illustrate the major differences; however, a detailed discussion of the various design requirements and their implementation is beyond the scope of this discussion. References (1) and (2) are sources of more detailed information. Also, example wall sizing calculations will be provided to illustrate the application of the relevant design codes under the candidate design conditions. The candidate steam supply Design Conditions are 600C (1112F) and 24MPa (3,480psi). The Operating Conditions or Service Levels will be somewhat lower and the difference shows up in some of the various design methodologies employed.

42 ENGINEERING↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

O(N) Quantum Molecular Dynamics (QMD) Algorithms, Code Requirements, Release Notes, and Library Deployment

The Exascale Computing Project (ECP) Co-design Center for Particle Applications (CoPA) is addressing the challenges for particle applications to run on upcoming exascale computing architectures. This includes short- and long-range molecular dynamics (MD), particle-in-cell (PIC), and quantum molecular dynamics (QMD). This document addresses $\mathcal{O}(N)$ QMD. The goal of this CoPA team is to develop $\mathcal{O}(N)$ linear scaling methods for QMD optimized for new and next generation architectures. This will provide the capability to simulate larger systems and run for longer timeframes than is possible today. Focus is initially on the density matrix construction. This requires efficient matrix formats and linear algebra operations for distributed architectures. A significant reduction in the wallclock time for an MD timestep is necessary to achieve practical large scale QMD. Equally challenging is to develop scalable distributed implementations. This requires the exploration of efficient data formats (dense, sparse, etc.), data decomposition and distribution across compute nodes using block- and graph-based methods. Traditional programming models such as MPI/OpenMP, hybrid MPI/OpenMP/Accelerator, as well as asynchronous task-based models will be explored to achieve maximum parallelism. Parallelism at the level of a matrix operation, solver, and/or application needs to be explored to gain the most benefit on new and emerging architectures. This report serves as a “living document” of the additions and enhancements throughout the ECP CoPA project for $\mathcal{O}(N)$ QMD. The following sections address the applications we are working with, the quantum chemistry libraries (BML and PROGRESS), and our co-design exploration through the use of a proxy application.

36 MATERIALS SCIENCE↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗