Search NASA⌕ Search

SEARCH · Search NASA

Results for “code validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SMR safety through HTTF modeling and benchmark efforts for code validation for gas-cooled reactor applications

Accurate modeling and simulation tools for thermal-hydraulics calculations are a key element needed to design and license new advanced reactors including Small Modular Reactors (SMR) and Microreactors. Uncertainties in modeling and simulation can have significant safety and economic implications. The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled prismatic-block nuclear reactors. High-quality measurement data is available from the HTTF that is suitable for a thermal-hydraulics code validation benchmark for gas-cooled reactor simulations. Here, this paper summarizes individual HTTF modeling efforts to date for tool validation at Idaho National Laboratory (INL), Argonne National Laboratory (ANL), Oregon State University (OSU) and Canadian Nuclear Laboratories (CNL) using system thermal-hydraulics codes, Computational Fluid Dynamics (CFD) codes and system-CFD code couplings. Also, the paper introduces the ongoing OECD Nuclear Energy Agency (NEA) High Temperature Gas Reactor Thermal-Hydraulics (HTGR T/H) benchmark that allows for better comparisons of results between different international modeling teams. The benchmark provides well defined computational problems that include code-to-code comparisons and comparisons to measured data. These problems provide an avenue for quantifying accuracy and identifying sources of uncertainty in thermal-hydraulics calculations, including in measured thermophysical properties, as part of validation for gas-cooled reactor simulation tools.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗

Using Calibrated Sodium Data for Preliminary Validation of the SRT Code for Advanced Reactors

Various types of non-light water reactors are currently engaged in the U.S. licensing process. Because of inherent differences compared with well-established large light water reactors, appropriate assessment tools are needed. Specifically, source term analysis, which determines environmental dose impacts from potential accident scenarios, is a crucial part of design and licensing. The U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic source term analysis for advanced reactor deployments. To align with these needs, Argonne National Laboratory has developed the Simplified Radionuclide Transport (SRT) source term analysis code for metal fuel Sodium-cooled Fast Reactors (SFRs) and microreactors. SRT conducts time-dependent radionuclide transport and retention in SFRs for core and ex-core radionuclide source accident sequences. The main objective of SRT is to provide rapid sensitivity and uncertainty analyses, incorporating parametric uncertainties and summarizing probabilistic results. As part of the code validation process, a study focused on the bubble scrubbing module was performed using an experiment recently carried out by the University of Wisconsin-Madison. Based on the analysis, the modeling approach in SRT provides accurate results for small and large aerosols, while slight underprediction of radionuclide aerosol removal are observed for medium sized aerosols. However, the deviation is minor, considering the highly uncertain phenomenon and range of results, and is in the conservative direction. In addition, uncertainty information derived from the experiments is further implemented, reflecting the actual span of parameters, which leads to enhanced agreement with code predictions. The results demonstrate that SRT provides reasonable predictions for the bubble scrubbing process in sodium pool.

Kam, Dong Hoon↗

Thermal Hydraulics Validation Activities in the ART-GCR Campaign

The Advanced Reactor Technologies - Gas Cooled Reactor Campaign (ART-GCR) is part of the United States Department of Energy - Office of Nuclear Energy's Advanced Reactor Technologies program aimed at developing a High Temperature Gas-cooled Reactor (HTGR) which will offer enhancements in safety and efficiency. The Design, Methods, and Validation arm of the ART-GCR program provides experience and advanced tools for HTGR design and analysis. The Methods and Validation arm is developing data to validate predictions of decay heat removal through an extensive experimental campaign the Natural Convection Shutdown Heat Removal Test Facility at Argonne National Laboratory. In-core thermal hydraulics validation is being facilitated through the OECD/NEA's Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data. That benchmark contains code-to-code and code-to-data comparisons for 3 sets of HTGR thermal hydraulics phenomena. This ongoing benchmark activity has 16 participants from 9 countries developing leading insights into HTGR thermal hydraulics code validation. The ART-GCR campaign is also working on the development of state-of-the-art MOOSE-based models of the High Temperature Engineering Test Reactor (HTTR). Through the OECD/NEA's HTTR Loss of Forced Cooling (LOFC) program, the ART-GCR campaign is developing a multiphysics transient code validation benchmark based on 3 HTTR experiments that will provide an opportunity for international collaboration on multiphysics code validation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiphysics Modeling of Microreactors with NEAMS codes, and Validation Based on KRUSTY Reactivity Insertion

The NEAMS Multiphysics Applications team continues to assess code usability and functionality for microreactor design and safety analyses, while demonstrating that NEAMS tools capture both steady-state and transient behavior across distinct microreactor concepts. In FY2025, the team advanced full-core, high-fidelity, multiphysics models that solve more complex problems and strengthen verification/validation for several microreactor systems: heat-pipe microreactor (HPMR), gas-cooled microreactor (GCMR), and the KRUSTY experiment. These models employ the MOOSE MultiApp/Transfers architecture with Griffin for neutronics, BISON for heat conduction/thermomechanics, Sockeye for heat pipes, SAM/THM for coolant channels and loops, and SWIFT for hydride behavior, with meshes generated via the MOOSE Reactor Module. The graphite models available in the Grizzly code were also investigated for future analyses. For the HPMR, a Na-HPMR variant was constructed to align with recently validated heat-pipe experiments and Sockeye’s LCVF capability, enabling mechanistic heat-pipe transients and startup modeling. The Na-HPMR will serve as the primary model for HPMR investigations in upcoming tasks. The load-following and single heat-pipe failure scenarios (Griffin/BISON/Sockeye), which were previously modeled for the K-HPMR, were replicated for the Na-HPMR, showing strong negative temperature feedback and highly localized thermal effects, respectively, while the startup case captured vapor-front progression and heat-removal activation. Solid mechanics was added to the previously built K-HPMR full-core model in BISON, showing minimal impact on steady-state reactivity yet enabling stress-field predictions that prepare the path for full-core TRISO performance analyses. For the GCMR, automated steady-state and four transient scenarios were executed using Griffin/BISON/SAM/SWIFT. Results confirm robust inherent safety: power collapses promptly in loss-of-cooling events, the inlet-temperature drop settles to a new equilibrium, and a single-channel blockage yields only a ~30 K local fuel-temperature rise with <0.4% power decrease. SWIFT-predicted hydrogen redistribution affects reactivity during both steady-state and transient conditions, underscoring its importance. A Brayton-cycle balance of plant (BOP) model in SAM/THM demonstrated stable startup behavior, and xenon-driven reactivity during load following was analyzed. To improve TRISO-compact temperature fidelity, a fast multiscale Heat Source Decomposition (HSD) treatment was implemented. Against heterogeneous benchmarks, HSD reduces underprediction of kernel temperatures and lowers predicted peak powers in reactivity-insertion transients compared to previous homogenized models. KRUSTY warm-critical validation progressed from FY2024 baselines: the 15Ȼ insertion shows excellent agreement in peak power (~2% high) and temperature trends, and the 30Ȼ case was automated via a feedback controller that maintained power near 3 kW for ~150 s with close agreement to data. The successful modeling of the warm critical tests has laid a strong foundation for simulating more complex nuclear system tests in the years ahead. Throughout FY2025, developer feedback was provided (e.g., MOOSE batch mesh generation, distributed pre-split meshes, Griffin sweeper on displaced meshes), several new models were contributed to the Virtual Test Bed, and an OECD-NEA WPRS multiphysics benchmark based on the HPMR was initiated to enable broader cross-comparison and best-practice development with the nuclear community at large.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Single Primary Heat Extraction and Removal Emulator (SPHERE) Power Transient Testing

For heat pipe cooled microreactor development, it is essential to understand the characteristics of heat pipes and how they function under a wide range of operating conditions. Modeling the startup and shutdown of heat pipe cooled microreactors has been a major challenge for the modeling code. Validating these parameters within the code is key for the development and licensing of heat pipe cooled microreactor designs. Idaho National Laboratory (INL) has completed testing on power transients of a heat pipe with a range of operating conditions. The resulting temperature profiles from this testing can be utilized to aid in the validation of the startup and shutdown portions of the heat pipe modeling code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HTGR Multiphysics Application Drivers FY26 Updates

This report summarizes FY26 progress under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program's high-temperature gas-cooled reactor (HTGR) application driver work, covering a wide range of activities such as code validation and multi-physics code assessment. 1) A detailed SAM model of the High-Temperature Engineering Test Reactor (HTTR) was developed using a unique-block grouping approach, with an extended parallel thermal network method to capture block-to-block conduction and radiation heat transfer, and applied to steady-state simulations of the HTTR 30~MW and 9~MW cases. 2) In another activity, SAM's newly implemented multi-component gas flow model was validated against the Natural convection Shutdown heat removal Test Facility (NSTF) argon ingress experiment, correctly capturing the density-driven suppression and thermal recovery of natural circulation observed when argon is introduced into the air-cooled Reactor Cavity Cooling System (RCCS) loop. 3) For the OECD/NEA High Temperature Test Facility (HTTF) benchmark, we co-led the international benchmark activities as well as the OECD/NEA final benchmark report to be released at the end of this year. 4) Finally, the coupled Griffin-SAM modeling capability for pebble-bed HTGRs was advanced by verifying the Griffin neutronics solution against Serpent Monte Carlo for a realistic non-uniform temperature distribution, resolving several deficiencies in the SAM-to-Griffin temperature transfer scheme, and enabling distinct fuel kernel, moderator, and coolant temperatures for cross section feedback. These new features were demonstrated in a PBR load-following transient.

Lee, Alvin↗

Second-order wave excitation forces in WEC-Sim/MOST: Implementation, experimental validation, and code-to-code comparison

Accurate prediction of second-order hydrodynamic loads is essential for floating bodies, including floating offshore wind turbines, wave energy converters, and hybrid wind–wave platforms. These nonlinear effects, arising from both sum- and difference-frequency forcing, are critical for capturing key response characteristics but remain challenging to model efficiently. In this work, we extend the open-source Wave Energy Converter Simulator / MATLAB for Offshore Simulation Tool by implementing second-order wave excitation forces, supporting both the full Quadratic Transfer Function formulation and the Newman approximation. The full Quadratic Transfer Function method is used for all code-to-code comparisons and experimental validation, while the Newman approximation is provided as a computationally lighter alternative. To benchmark the new capability, we perform a code-to-code comparison with OpenFAST and OrcaFlex. We then validate the enhanced model using wave-tank measurements of a 1:96 scale DeepCwind semi-submersible, showing that second-order effects are required to reproduce platform motions. The implementation employs a computationally efficient pre-computation strategy for second-order wave excitation forces, reducing simulation cost while maintaining engineering accuracy. Overall, this work advances the tool as an open-source and versatile tool for modelling floating offshore renewable-energy systems requiring second-order hydrodynamic fidelity.

17 WIND ENERGY↗

Participation in and Assessment of the Third DNCSH Public Workshop

Advanced reactor development and deployment is introducing fuel forms, materials, and configurations that differ from those used in traditional light-water reactors (LWRs), including tristructural-isotropic (TRISO)-based fuels, moderators, high-temperature materials, and compact core designs. These attributes can fall outside the range of applicability of existing criticality safety validation bases and may require additional work in code validation and benchmark applicability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Correlation Methods for Use in Criticality Safety

Although their adoption by practitioners has been limited, the introduction of similarity indices in criticality safety was a major step forward in reducing the reliance on expert judgement in discerning applicable experiments for the validation of new appliations in criticality safety analyses. Similarity indices have been successfully employed in bias trending and data assimilation techniques, but it is often unclear which acceptance criteria should be used. In their 2004 paper, Broadhead et al. specify the most widely used similarity parameter, ck, as an acceptance cutoff at 0.9. (Broadhead et al., ”Sensitivity and Uncertainty-Based Criticality Safety Validation Techniques,” Nucl. Sci. Eng. 146, 340–366, 2004). Experiments with a ck < 0.9 are often not considered applicable for code validation. This heuristic is based on quantitative studies and engineering judgement, but in some cases, experiments with ck < 0.9 can be used to accurately estimate computational bias. This suggests that further analysis is needed to determine what components of ck are driving applicability and accuracy in bias estimation. For cases in which applicable experiments may not be available (as is the case with UF6 transport canisters), understanding what distinguishes experiments in providing adequate bias estimates aside from just the similarity index is particularly necessary. To further the goal to better interpret ck values, several visualization tools were developed to assist in the investigation of which components of ck are driving applicability.

ck↗

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems for design, optimization, and licensing calculations requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the OECD/NEA Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). This benchmark contains problems for systems code, computational fluid dynamics (CFD), and coupled systems code/CFD modeling representing lower plenum mixing and both the depressurized and pressurized conduction cooldown (DCC and PCC respectively) transients. Benchmark problems include exercises for code-to-code and code-to-data comparisons as well as an exercise for error scaling between HTTF and the Modular High Temperature Gas-Cooled Reactor, which serves as the basis for the HTTF design. Previous analysis as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. The new model provides a finer nodalization to assess the impact of radial nodalization and allows for asymmetric heating within the core, which was a feature of multiple HTTF experiments. In this paper, we present the new RELAP5-3D model of HTTF. In addition to describing the new model, this paper compares the new and old models and provides results for a full-power steady state, a DCC, and a PCC in HTTF. These analyses are based on the code-to-code comparison exercises for the DCC and PCC problems of the HTGR T/H benchmark. We present the results of these exercises from the new model and compare them to the results of the old model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAS4A/SASSYS-1 Validation with FFTF Tests

The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. In preparation for the Passive Safety Testing program, a series of individual reactivity feedback tests were performed which were designed to simulate and validate specific features and reactivity feedbacks of the FFTF core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of Numerical Tools for Calculating Reactivity Feedback in Sodium Fast Reactors Using SEFOR Experimental Data

The Southwest Experimental Fast Oxide Reactor (SEFOR) was an experimental sodium-cooled fast breeder reactor operated from 1969 to 1972 with experiments designed to measure Doppler reactivity feedback in a wide temperature range from around 350 °F to temperatures approaching the melting point of mixed oxide fuel of around 5000 °F, providing valuable data for code validations. Co-supported by the Department of Energy (DOE) Fast Reactor Program (FRP) and the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the SEFOR benchmark project focused on using the experimental data to validate numerical tools that are used in industry and academia to design and license sodium-cooled fast reactors (SFRs). By the end of FY-25, substantial progress was achieved in the SEFOR benchmark study. A variety of numerical tools commonly used for modeling SFRs were applied to develop models for SEFOR core configurations I-D, I-E, I-I, and I-J. These included Monte Carlo codes such as MCNP, Serpent, and Shift; deterministic codes such as the legacy Argonne Reactor Computation (ARC) suite and the high-fidelity NEAMS code Griffin; and the system analysis code SAS4A/SASSYS-1 (SAS). Using these models, both SEFOR zero-power experiments and power-ascending tests were successfully simulated. Comparisons were performed against experimental measurements of core criticalities, reflector worth, kinetics parameters (Λ/βeff), isothermal reactivity feedback (from 350 °F to 760 °F at zero power), and power-ascending reactivity feedback (as power increased from 0.4 MW to 17 MW). In general, these comparisons demonstrated very good agreement between numerical results and experimental data. In Fiscal Year 26 (FY-26), the SEFOR benchmark project will continue to address the modeling issues identified in FY-25. Effort will focus on the simulation of reactivity insertion transients in SEFOR core II using the ARC/SAS model. Future work will also focus on incorporating BISON into the SEFOR core modeling process to enable the first Multiphysics simulations of the isothermal tests based on the MOOSE framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗