Search NASA⌕ Search

SEARCH · Search NASA

Results for “coding spatial acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

47 OTHER INSTRUMENTATION↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

iMaNGA: mock MaNGA galaxies based on IllustrisTNG and MaStar SSPs – I. Construction and analysis of the mock data cubes

ABSTRACT Galaxy formation and evolution simulations are essential tools to probe poorly known astrophysics processes, but particular care is needed to compare simulations with galaxy observations, as observed data need to be modelled as well. We present a method to generate mock galaxies from the hydro-dynamical IllustrisTNG simulations which are suited to compare with integral field spectroscopic observation of galaxies from the SDSS-IV/Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. First, we include the same instrumental effects and procedures as adopted in the acquisition and analysis of real data. Furthermore, we generate the galaxy spectra from the simulations using new stellar population models based on the MaNGA stellar library (MaStar). In this way, our mock data cubes have the same spatial sampling, cover the same wavelength range (3600–10 300 Å), and share the same spectral resolution (R ≈ 1800) and flux calibration of real MaNGA galaxy spectra. In this first paper, we demonstrate the method over an early- and a late-type simulated galaxy from TNG50. We analyse the correspondent mock MaNGA-like data cubes with the same full spectral fitting code, firefly, which was used for the observed spectra. We find that the intrinsic and recovered age and metallicity gradients are consistent within 1σ, with residuals over all tassels consistent with 0 at the 68 ${{\ \rm per\ cent}}$ confidence level. We also perform the challenging test at comparing intrinsic and recovered star formation histories, finding a close resemblance between input and output. In follow-up papers, we will present a full simulated MaNGA-like catalogue (≈10 000 galaxies) with a comprehensive comparison of TNG50 simulations to MaNGA observational results.

79 ASTRONOMY AND ASTROPHYSICS↗

Individual Motorist Data - Ohio EV Ownership Trends

The individual motorist dataset contains data and analysis of consumer electric vehicle (EV) ownership trends in rural Appalachian Ohio in comparison with statewide trends. The data span four years, from Q1 2020 to Q2 2023 (partial). They are sourced from the Ohio Bureau of Motor Vehicles registration records and contain detail on drivetrain type (battery-electric vehicle [BEV] or plug-in hybrid electric vehicle [PHEV]); specific vehicle make and model; and registration location at county, city, and ZIP code levels of spatial resolution. Registration data are analyzed at the county level against such indicators as median income, poverty status, urban-rural status, and density of public charging infrastructure. In addition to tabular data, a GIS shapefile with many analysis fields joined is included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗