Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimal coherent image amplification by two-wave coupling in photorefractive BaTiO3

Coherent image amplification by two-wave coupling in a crystal of photorefractive BaTiO3 is analyzed. This amplifier is optimized with respect to such operational characteristics as gain versus amplified image quality and space-bandwidth product. Experimental results that demonstrate coherent image amplification of 4000, space-bandwidth product of 1,000,000, and gray-level dynamic range of greater than 100 are presented.

Fainman, Y.↗

2D coherence imaging measurements of C 2+ ion temperatures in the divertor of Wendelstein 7-X

For the first time, 2D ion temperature values are derived from coherence imaging spectroscopy (CIS) fringe contrast measurements by taking Zeeman line broadening effects into account during the analysis procedure of a spatial-heterodyne CIS instrument. This allowed 2D images of C 2+ ion temperatures (T i ) across the 3D-shaped island divertor of the Wendelstein 7-X stellarator. Ion temperatures ranging from 10 to 20 eV are observed for the C 2+ impurity species in the region above the divertor targets. During the transition from the attached to the detached plasma state, the C 2+ radiation zone moves from close to the divertor target towards the last closed flux surface. Within this radiation zone, C 2+ temperature does not decrease significantly. Experimentally, the coherence imaging measurements were cross-calibrated at one poloidal cross-section using a high resolution Echelle spectrometer, that shared its sightlines with the coherence imaging diagnostic. The spectra demonstrated that, apart from Doppler broadening, the Zeeman effect significantly contributes to the spectral line broadening and cannot be neglected when analyzing the CIS contrast data for T i extraction in the edge and scrape-off-layer of Wendelstein 7-X (W7-X), due to the relatively low temperatures (T i < 100 eV) and high magnetic fields (B ≈ 2.5 T).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of Doppler coherence imaging for 2D ion velocity measurements on DIII-D

Coherence Imaging Spectroscopy (CIS) has emerged as a powerful tool for investigating complex ion phenomena in the boundary of magnetically confined plasma devices. The combination of Fourier-transform interferometry and high-resolution fast-framing cameras has made it possible to make sensitive velocity measurements that are also spatially resolved. However, this sensitivity makes the diagnostic vulnerable to environmental effects including thermal drifts, vibration, and magnetic fields that can influence the velocity measurement. Additionally, the ability to provide an absolute calibration for these geometries can be impacted by differences in the light-collection geometry between the plasma and reference light source, spectral impurities, and the presence of thin-films on in-vessel optics. This work discusses the mitigation of these effects and demonstration that environmental effects result in less than 0.5 km/s error on the DIII-D CIS systems. A diagnostic comparison is used to demonstrate agreement between CIS and traditional spectroscopy once tomographic artifacts are accounted for.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser calibration of the DIII-D coherence imaging system

Here, we describe an in situ calibration technique for Coherence Imaging Spectroscopy (CIS) that measures 2-D images of ion flows on DIII-D. A low power CW diode laser that is tuneable in the range 464-468 nm along with a precision wavemeter (10 –5 nm resolution) is used to characterize the interferometer phase as a function of wavelength in the region of C iii (465 nm) and He ii (468 nm). The interferometer is stabilized both mechanically and thermally to minimize drift during the calibration. Optical stirring and an integration sphere are utilized to obtain spatially uniform calibration images. The quality of the calibration data enables a measurement of phase versus wavelength over approximately 10 fringes of the interferometer. These coefficients can also be related to the geometry of the optics and the birefringent crystal of the interferometer. On DIII-D, the integration sphere with the laser light is inserted into the CIS optical system between shots and the laser image and wavelength are automatically recorded, providing a zero velocity reference

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

A new calibration implementation for Doppler Coherence Imaging Spectroscopy

A new widely tunable, continuous-wave laser named C-Wave enables direct calibration at the unshifted, center-of-mass wavelength for most plasma lines in the range between 450 and 650 nm for Doppler Coherence Imaging Spectroscopy. It also provides the ability to scan around each desired wavelength over a small range of ±50pm, thus enabling an easy way to translate the measured phase difference ΔΦ of the diagnostic to the desired Doppler line shift Δλ, that corresponds to the physical parameter of interest, the particle velocity of an observed plasma species. A first wavelength scan of the C-Wave laser ±50pm around a single plasma line of interest, C III at 464.881 nm, is presented and compared to a simulated wavelength scan. It demonstrates not only the C-Wave capability as a Doppler CIS calibration source, but also its potential to immensely simplify Doppler CIS analysis for nearly all visible plasma lines of interest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Localization and coherent imaging of hidden moving objects using laser speckle

Imaging and sensing of moving objects through opaque scattering media is a challenging but important problem in a variety of applications, including environmental sensing, biomedical imaging, and material inspection. We have previously demonstrated a technique to coherently image a moving object through thick, heavily scattering random media using correlations of speckle images as a function of the object’s spatial translation. Here, we demonstrate that this technique can be combined with localization to achieve imaging without prior knowledge of the object’s motion, greatly extending the application domain. This method is effective beyond the thin or weakly scattering regime and, rather than motion being deleterious, exploits the information available when the hidden object is moving, as could be the case in a cluttered terrestrial environment or through substantial levels of biological tissue scatter.

Hastings, Ryan L. (ORCID:0009000095977807)↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

In situ coherent diffractive imaging

Coherent diffractive imaging (CDI) has been widely applied in the physical and biological sciences using synchrotron radiation, X-ray free-electron laser, high harmonic generation, electrons, and optical lasers. One of CDI’s important applications is to probe dynamic phenomena with high spatiotemporal resolution. Here, we report the development of a general in situ CDI method for real-time imaging of dynamic processes in solution. By introducing a time-invariant overlapping region as real-space constraint, we simultaneously reconstructed a time series of complex exit wave of dynamic processes with robust and fast convergence. We validated this method using optical laser experiments and numerical simulations with coherent X-rays. Our numerical simulations further indicated that in situ CDI can potentially reduce radiation dose by more than an order of magnitude relative to conventional CDI. With further development, we envision in situ CDI could be applied to probe a range of dynamic phenomena in the future.

47 OTHER INSTRUMENTATION↗

Doppler coherence imaging of divertor and SOL flows in ASDEX upgrade and Wendelstein 7-X

Measurement of ion dynamics is of great importance to the study of plasma exhaust and impurity particle flows in the scrape-off-layer (SOL) and divertor in magnetic confinement experiments. Doppler coherence imaging spectroscopy (CIS) is a passive optical diagnostic that produces 2D images of line-integrated ion flow velocity. Doppler CIS flow measurements of neutral deuterium and impurities were conducted for the first time in the divertor of the medium-sized tokamak experiment ASDEX Upgrade. A detailed sightline, emission and magnetic field analysis was undertaken to identify location and direction of flows. Under the assumption of toroidal axisymmetry, they revealed mainly parallel impurity flows in the proximity of the X-point and target plates on the order of 20 km s -1 . Two Doppler CIS systems are currently set up for the optimized stellarator Wendelstein 7-X (W7-X). With this being said, the main task of this diagnostic will be the measurement of impurity ion flows in one of the island divertors of W7-X. EMC3-EIRENE simulations have been carried out to estimate the flow behaviour in the W7-X SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A parametric study of various synthetic aperture telescope configurations for coherent imaging applications

The comparative advantages of synthetic aperture telescopes (SATs) of segmented primary mirror and common secondary mirror type, on the one hand, and on the other those employing an array of independent telescopes, are discussed. The diffraction-limited optical performance of both redundant and nonredundant subaperture configurations are compared in terms of point spread function characteristics and encircled energy plots. Coherent imaging with afocal telescope SATs involves a pupil-mapping operation followed by a Fourier transform one. A quantitative analysis of the off-axis optical performance degradation due to pupil-mapping errors is presented, together with the field-dependent effects of residual design aberrations of independent telescopes.

Harvey, James E.↗

Optimum coherent imaging of a limited field of view in the presence of angular and aperture noise

The question of image distribution reconstruction for coherent illumination of an object located in the aperture far zone is considered from first principles without postulating any particular optical spread function. The object function is mathematically modeled as a complex random function of angular coordinates, and it is assumed that the object distribution of interest is angularly limited to a certain a priori assigned field of view (FOV). A linear reconstruction procedure that is uniformly optimal in the FOV is established by using the methods of statistical estimation. Two special cases are examined: imaging a limited sector of a wide-angle random scene and objects in the FOV immersed in a wide-angle background of angular noise. It is noted that the domain of application of the reconstruction method is restricted to microwave frequencies.

Borgiotti, G. V.↗

Imaging Coherent Structural Dynamics with Ultrafast Electron Microscopy

Development of ultrafast electron and X-ray scattering methods has enabled direct routes to probing atomic-scale structural dynamics. This in turn has led to new insight into lattice responses to a variety of dynamic processes associated with phase transformations, electron-lattice correlations, and nanoscale mechanical motion, to name a few. Presently, the most wide-spread approaches involve using table-top, laser-driven electron-scattering chambers or femtosecond (fs) X-ray beamlines to probe dynamics in reciprocal space and, in many instances, over specimen regions that are large relative to unit-cell dimensions and discrete (atomic and nanoscale) structural and morphological defects (e.g., vacancies, line and screw dislocations, grain boundaries, interfaces, etc.). As a result, the transients monitored for relatively large-spot-size reciprocal-space measurements – typically some aspect of a Bragg reflection (intensity, position, width, shape) – may be comprised of a range of responses occurring within the probed region. To directly resolve the role of distinct morphologies and structural features on dynamics associated with the nucleation, emergence, evolution, and decay of coherent phenomena, one would ideally directly image the local, nanoscale behaviors and precisely correlate responses to the nature of the feature. Here, I will show how such effects can be directly probed with ultrafast electron microscopy (UEM). After a brief overview of the operating principles of UEM, I will discuss how we are using real-space imaging to directly visualize coherent structural dynamics in a variety of nanostructured and nanoscale materials.

47 OTHER INSTRUMENTATION↗

Bragg Coherent Imaging of Fluctuating Domains

This review presents two examples of domain dynamics in crystalline solid state samples which were imaged recently with synchrotron X-rays by Bragg Coherent Diffraction methods. Domains are associated with sub-atomic phase shifts in the structure which are revealed by the strong phase contrast associated with Bragg diffraction. At low temperatures, La2-xSrxNiO4 has an antiferromagnetic spin-ordered phase with correlation lengths of 200 nm; its domains are imaged with magnetic Bragg Ptychography to visualize their slow fluctuations. Hydrothermally synthesized nanocrystalline BaTiO3 is found to be made up of ~50 nm domains using Bragg Coherent Diffraction Imaging; electric field induced movement of its internal domain walls is a likely explanation of the nano-material's anomalously large dielectric constant, which is used in the manufacture of multilayer ceramic capacitors

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.

42 ENGINEERING↗

Imaging Coherent Acoustic Phonons in LaFeAsO with Ultrafast Electron Microscopy

Several iron pnictide materials, such as LaFeAsO and BaFe 2 As 2 , display high-temperature superconductivity when lightly doped. Such compounds often undergo temperature-dependent structural, magnetic, and electronic transitions, which are generally thought to be linked in some way to the superconducting phase. In order to resolve the interdependencies of the various degrees of freedom, ultrafast spectroscopic methods have frequently been used to determine timescales associated with charge-carrier and switching dynamics in the superconducting materials, and the more-recent advent of ultrafast structural probes (femtosecond X-ray and electron scattering) has led to insights into both the cuprates and the pnictides (both the doped and parent compounds). As with dedicated reciprocal-space methods, ultrafast transmission electron microscopy (UEM) provides a method for directly probing impulsively-excited structural dynamics, with the added benefit of real-space imaging with combined nanometer and sub-picosecond spatiotemporal resolutions. In this work we report the direct imaging of coherent acoustic-phonon dynamics in the 1111-type iron-pnictide parent compound LaFeAsO via UEM.

36 MATERIALS SCIENCE↗

Synthetic-Aperture Coherent Imaging From A Circular Path

Imaging algorithms based on exact point-target responses. Developed for use in reconstructing image of target from data gathered by radar, sonar, or other transmitting/receiving coherent-signal sensory apparatus following circular observation path around target. Potential applications include: Wide-beam synthetic-aperture radar (SAR) from aboard spacecraft in circular orbit around target planet; SAR from aboard airplane flying circular course at constant elevation around central ground point, toward which spotlight radar beam pointed; Ultrasonic reflection tomography in medical setting, using one transducer moving in circle around patient or else multiple transducers at fixed positions on circle around patient; and Sonar imaging of sea floor to high resolution, without need for large sensory apparatus.

Jin, Michael Y.↗