Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent elastic neutrino-nucleus scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment

We present searches for light dark matter (DM) with masses 3–9 GeV/𝑐 2 in the presence of coherent elastic neutrino-nucleus scattering (CE⁢𝜈⁢NS) from 8 B solar neutrinos with the LUX-ZEPLIN experiment. This analysis uses a 5.7 tonne-yr exposure with data collected between March 2023 and April 2025. In an energy range spanning 1–6 keV, we report no significant excess of events attributable to dark matter nuclear recoils, but we observe a significant signal from 8 B CE ⁢𝜈 ⁢NS interactions that is consistent with expectation. We set world-leading limits on spin-independent and spin-dependent-neutron DM-nucleon interactions for masses down to 5 GeV/𝑐 2 . In the no-dark-matter scenario, we observe a signal consistent with 8 B CE⁢ 𝜈 ⁢NS events, corresponding to a 4.5⁢𝜎 statistical significance. This is the most significant evidence of 8 B CE 𝜈 ⁢NS interactions and is enabled by robust background modeling and mitigation techniques. This demonstrates LZ’s ability to detect rare signals at keV-scale energies.

Dark matter detectors↗

New physics versus quenching factors in Coherent Neutrino Scattering

Recent results on the Coherent Elastic Neutrino-Nucleus Scattering (CEνNS) on germanium present significant discrepancies among experiments. We perform a combined analysis of the Dresden-II, CONUS+ and COHERENT data, quantifying the impact of quenching factor uncertainties on their CEνNS cross section measurement. No choice of quenching factor can bring these three data sets into mutual agreement, whereas the combination of COHERENT with either Dresden-II or CONUS+ agrees well albeit for very different quenching factors. We further study the quenching factor dependence on the sensitivity of these experiments to a large neutrino magnetic moment, finding that the constraints can vary by up to an order of magnitude. Our work highlights the importance of reducing this uncertainty on quenching factors in order to probe new physics from neutrinos at the low-energy frontier.

neutrino interactions↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Low-Energy Neutrino-Nucleus Scattering and New Physics

The interactions of low-energy neutrinos with nuclei provide a unique window to explore various Standard Model (SM) and Beyond the Standard Model (BSM) processes. In particular, the recent observation of coherent elastic neutrino-nucleus scattering (CEvNS), predicted over five decades ago, has generated significant interest across disciplines. With its high cross section and suitability for compact detectors, particularly with stopped pion neutrinos, CEvNS offers a powerful probe for light, weakly coupled new physics. Ongoing global experimental efforts now aim to leverage CEvNS to test SM predictions and search for BSM signals, where deviations in event rates or spectra could reveal new physics. We present here an estimate of the number of recoil events obtained from CEvNS using the current and upcoming liquid argon based experiments. Furthermore, the event rate due to the inclusion of neutrino magnetic moment is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak-charge radius of 40 Ar: From CREX constraints to CE⁢𝜈⁢NS sensitivity

Despite significant theoretical efforts, the CREX-PREX dilemma remains unresolved, preventing the reliable prediction of neutron (or weak-charge) radii that, besides their intrinsic nuclear-structure interest, often serve to quantify the impact of nuclear uncertainties in searches for new physics. Coherent elastic neutrino-nucleus scattering is a clean and attractive portal to new physics, whose sensitivity may be impacted by such nuclear uncertainties. In this paper I use CREX as the basis, together with a strong calcium-argon correlation, to provide a robust baseline for the weak radius of 40 Ar : 𝑅$^{40}_{wk}$ = 3.452 ± 0.028 (stat) ± 0.022 (syst) fm. Here, the weak radius of argon is an observable, highly relevant to ongoing and future liquid-argon campaigns, that encodes the loss of coherence at small momentum transfers.

39 ≤ A ≤ 58↗

Prospects for exploring non-standard neutrino properties with argon-based CEvNS experiments

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful frame-work for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilab’s Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.

Carey, Sam [Wayne State U.] (ORCID:000900029607531↗

Modeling and Characterization of TES-Based Detectors for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE nu NS) offers a valuable approach in searching for physics beyond the standard model. The Ricochet experiment aims to perform a precision measurement of the CE nu NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass of around 30 g and an energy threshold of below 100 eV. The array includes nine detectors read out by transition-edge sensors (TES). These TES-based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article, we present an update on the characterization and modeling of a prototype TES detector.

Chang, C. L.↗

Aluminum relaxation as the source of excess low energy events in low threshold calorimeters

A previously unexplained background called the Low Energy Excess has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminum films as mediated by the motion of dislocations may account for these observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications of first neutrino-induced nuclear recoil measurements in direct detection experiments: Probing nonstandard interaction via CE ν NS

PandaX-4T and XENONnT have recently reported the first measurement of nuclear recoils induced by the B 8 solar neutrino flux, through the coherent elastic neutrino-nucleus scattering ( CE ν NS ) channel. As long anticipated, this is an important milestone for dark matter searches as well as for neutrino physics. This measurement means that these detectors have reached exposures such that searches for low mass, ≲ 10 GeV dark matter cannot be analyzed using the background-free paradigm going forward. It also opens a new era for these detectors to be used as neutrino observatories. In this paper we assess the sensitivity of these new measurements to new physics in the neutrino sector. We focus on neutrino nonstandard interactions (NSI) and show that—despite the still moderately low statistical significance of the signals—these data already provide valuable information. We find that limits on NSI from PandaX-4T and XENONnT measurements are comparable to those derived using combined COHERENT CsI and LAr data. Furthermore, they provide sensitivity to pure τ flavor parameters that are not accessible using stopped-pion or reactor sources. With larger exposures and consequently improvements of statistical uncertainties, forthcoming data from these experiments will provide important, novel results for CE ν NS -related physics. Published by the American Physical Society 2025

Sierra, D. Aristizabal↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress of the CHILLAX Experiment (HEPCAT Year 1 Report)

A significant facet of modern experimental particle physics research is that of searching for hypothetical rare events. In this context, “rare” means “unusual to detect in the laboratory”, and can be a confirmed phenomenon (e.g. coherent elastic neutrino-nucleus scattering, which has a high cross section at low, difficult to detect energies), or an as-of-yet unobserved phenomenon that may not exist (e.g. dark matter - standard model matter non-gravitational interaction). A salient challenge for experimentalists is to devise detectors optimized for observing such rare events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium

Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.

Kavner, Alexander R.↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

A neutrino floor for the Migdal effect

Neutrino-nucleus scatterings in the detector could induce electron ionization signatures due to the Migdal effect. We derive prospects for a future detection of the Migdal effect via coherent elastic solar neutrino-nucleus scatterings in liquid xenon detectors, and discuss the irreducible background that it constitutes for the Migdal effect caused by light dark matter-nucleus scatterings. Furthermore, we explore the ionization signal induced by some neutrino electromagnetic and non-standard interactions on nuclei. In certain scenarios, we find a distinct peak on the ionization spectrum of xenon around 0.1 keV, in clear contrast to the Standard Model expectation.

Experimental Nuclear Physics↗