Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent neutrino–nucleus scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment

We present searches for light dark matter (DM) with masses 3–9 GeV/𝑐 2 in the presence of coherent elastic neutrino-nucleus scattering (CE⁢𝜈⁢NS) from 8 B solar neutrinos with the LUX-ZEPLIN experiment. This analysis uses a 5.7 tonne-yr exposure with data collected between March 2023 and April 2025. In an energy range spanning 1–6 keV, we report no significant excess of events attributable to dark matter nuclear recoils, but we observe a significant signal from 8 B CE ⁢𝜈 ⁢NS interactions that is consistent with expectation. We set world-leading limits on spin-independent and spin-dependent-neutron DM-nucleon interactions for masses down to 5 GeV/𝑐 2 . In the no-dark-matter scenario, we observe a signal consistent with 8 B CE⁢ 𝜈 ⁢NS events, corresponding to a 4.5⁢𝜎 statistical significance. This is the most significant evidence of 8 B CE 𝜈 ⁢NS interactions and is enabled by robust background modeling and mitigation techniques. This demonstrates LZ’s ability to detect rare signals at keV-scale energies.

Dark matter detectors↗

New physics versus quenching factors in Coherent Neutrino Scattering

Recent results on the Coherent Elastic Neutrino-Nucleus Scattering (CEνNS) on germanium present significant discrepancies among experiments. We perform a combined analysis of the Dresden-II, CONUS+ and COHERENT data, quantifying the impact of quenching factor uncertainties on their CEνNS cross section measurement. No choice of quenching factor can bring these three data sets into mutual agreement, whereas the combination of COHERENT with either Dresden-II or CONUS+ agrees well albeit for very different quenching factors. We further study the quenching factor dependence on the sensitivity of these experiments to a large neutrino magnetic moment, finding that the constraints can vary by up to an order of magnitude. Our work highlights the importance of reducing this uncertainty on quenching factors in order to probe new physics from neutrinos at the low-energy frontier.

neutrino interactions↗

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Clarity through the neutrino fog: constraining new forces in dark matter detectors

The PandaX-4T and XENONnT experiments present indications of Coherent Elastic Neutrino Nucleus Scattering (CEνNS) from 8 B solar neutrinos at 2.6σ and 2.7σ, respectively. This constitutes the first observation of the neutrino “floor” or “fog”, an irreducible background that future dark matter searches in terrestrial detectors will have to contend with. Here, we first discuss the contributions from neutrino–electron scattering and from the Migdal effect in the region of interest of these experiments, and we argue that they are non-negligible. Second, we make use of the recent PandaX-4T and XENONnT data to derive novel constraints on light scalar and vector mediators coupling to neutrinos and quarks. We demonstrate that these experiments already provide world-leading laboratory constraints on new light mediators in some regions of parameter space.

neutrino interactions↗

Quartz fluorescence backgrounds in xenon particle detectors

It has been known for almost a decade that delayed photon noise with a power law time profile follows scintillation pulses in liquid xenon particle detectors. The origin of the noise has remained unknown, and in the past two years, has become an overwhelming background for low-threshold dark matter searches aimed at 𝒪⁡(10) GeV dark matter particle masses, as well as measurements of coherent neutrino-nucleus scattering of 8 B solar neutrinos. We have performed a comprehensive series of tests in a small liquid xenon cell at LBL, from which we conclude that the dominant component of this delayed photon noise is due to UV-induced fluorescence of quartz photosensor windows.

crystal optics↗

Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids, an understanding of which is essential for interpreting particle interactions at and below the eV scale.

coherent neutrino–nucleus scattering↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Low-Energy Neutrino-Nucleus Scattering and New Physics

The interactions of low-energy neutrinos with nuclei provide a unique window to explore various Standard Model (SM) and Beyond the Standard Model (BSM) processes. In particular, the recent observation of coherent elastic neutrino-nucleus scattering (CEvNS), predicted over five decades ago, has generated significant interest across disciplines. With its high cross section and suitability for compact detectors, particularly with stopped pion neutrinos, CEvNS offers a powerful probe for light, weakly coupled new physics. Ongoing global experimental efforts now aim to leverage CEvNS to test SM predictions and search for BSM signals, where deviations in event rates or spectra could reveal new physics. We present here an estimate of the number of recoil events obtained from CEvNS using the current and upcoming liquid argon based experiments. Furthermore, the event rate due to the inclusion of neutrino magnetic moment is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak-charge radius of 40 Ar: From CREX constraints to CE⁢𝜈⁢NS sensitivity

Despite significant theoretical efforts, the CREX-PREX dilemma remains unresolved, preventing the reliable prediction of neutron (or weak-charge) radii that, besides their intrinsic nuclear-structure interest, often serve to quantify the impact of nuclear uncertainties in searches for new physics. Coherent elastic neutrino-nucleus scattering is a clean and attractive portal to new physics, whose sensitivity may be impacted by such nuclear uncertainties. In this paper I use CREX as the basis, together with a strong calcium-argon correlation, to provide a robust baseline for the weak radius of 40 Ar : 𝑅$^{40}_{wk}$ = 3.452 ± 0.028 (stat) ± 0.022 (syst) fm. Here, the weak radius of argon is an observable, highly relevant to ongoing and future liquid-argon campaigns, that encodes the loss of coherence at small momentum transfers.

39 ≤ A ≤ 58↗

Prospects for exploring non-standard neutrino properties with argon-based CEvNS experiments

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful frame-work for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilab’s Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.

Carey, Sam [Wayne State U.] (ORCID:000900029607531↗

Aluminum relaxation as the source of excess low energy events in low threshold calorimeters

A previously unexplained background called the Low Energy Excess has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminum films as mediated by the motion of dislocations may account for these observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implications of first neutrino-induced nuclear recoil measurements in direct detection experiments: Probing nonstandard interaction via CE ν NS

PandaX-4T and XENONnT have recently reported the first measurement of nuclear recoils induced by the B 8 solar neutrino flux, through the coherent elastic neutrino-nucleus scattering ( CE ν NS ) channel. As long anticipated, this is an important milestone for dark matter searches as well as for neutrino physics. This measurement means that these detectors have reached exposures such that searches for low mass, ≲ 10 GeV dark matter cannot be analyzed using the background-free paradigm going forward. It also opens a new era for these detectors to be used as neutrino observatories. In this paper we assess the sensitivity of these new measurements to new physics in the neutrino sector. We focus on neutrino nonstandard interactions (NSI) and show that—despite the still moderately low statistical significance of the signals—these data already provide valuable information. We find that limits on NSI from PandaX-4T and XENONnT measurements are comparable to those derived using combined COHERENT CsI and LAr data. Furthermore, they provide sensitivity to pure τ flavor parameters that are not accessible using stopped-pion or reactor sources. With larger exposures and consequently improvements of statistical uncertainties, forthcoming data from these experiments will provide important, novel results for CE ν NS -related physics. Published by the American Physical Society 2025

Sierra, D. Aristizabal↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium

Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.

Kavner, Alexander R.↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

Searches for CE ν NS and physics beyond the standard model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering ( CE ν NS ) of reactor antineutrinos off silicon nuclei using thick fully depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with subelectron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing, data quality, and event selection for CE ν NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021–2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits for the neutrino interaction rates, comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model improve the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation by CONNIE obtains the best limits on the DM-electron scattering cross section by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗