Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗

Development of the Science Data System for the International Space Station Cold Atom Lab

Cold Atom Laboratory (CAL) is a facility that will enable scientists to study ultra-cold quantum gases in a microgravity environment on the International Space Station (ISS) beginning in 2016. The primary science data for each experiment consists of two images taken in quick succession. The first image is of the trapped cold atoms and the second image is of the background. The two images are subtracted to obtain optical density. These raw Level 0 atom and background images are processed into the Level 1 optical density data product, and then into the Level 2 data products: atom number, Magneto-Optical Trap (MOT) lifetime, magnetic chip-trap atom lifetime, and condensate fraction. These products can also be used as diagnostics of the instrument health. With experiments being conducted for 8 hours every day, the amount of data being generated poses many technical challenges, such as downlinking and managing the required data volume. A parallel processing design is described, implemented, and benchmarked. In addition to optimizing the data pipeline, accuracy and speed in producing the Level 1 and 2 data products is key. Algorithms for feature recognition are explored, facilitating image cropping and accurate atom number calculations.

bose einstein condensate↗

Ion-Atom Cold Collisions and Atomic Clocks

This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime.

Ion-Atom↗

A Compact, High-Flux Cold Atom Beam Source

The performance of cold atom experiments relying on three-dimensional magneto-optical trap techniques can be greatly enhanced by employing a highflux cold atom beam to obtain high atom loading rates while maintaining low background pressures in the UHV MOT (ultra-high vacuum magneto-optical trap) regions. Several techniques exist for generating slow beams of cold atoms. However, one of the technically simplest approaches is a two-dimensional (2D) MOT. Such an atom source typically employs at least two orthogonal trapping beams, plus an additional longitudinal "push" beam to yield maximum atomic flux. A 2D atom source was created with angled trapping collimators that not only traps atoms in two orthogonal directions, but also provides a longitudinal pushing component that eliminates the need for an additional push beam. This development reduces the overall package size, which in turn, makes the 2D trap simpler, and requires less total optical power. The atom source is more compact than a previously published effort, and has greater than an order of magnitude improved loading performance.

Kellogg, James R.↗

Cold atoms in space: community workshop summary and proposed road-map

We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

Little, Bethany J. (ORCID:0000000332892798)↗

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

Generation of a Cold Atom Beam from a Pyramidal Magneto-Optical Trap

Techniques to generate cold atom beams are of great interest in a variety of applications, from atomic frequency standards and atom optics to experimental studies of Bose-Einstein condensation. Cold atom beams have been produced by slowing thermal atomic beams using the Zeeman-slowing technique or chirped lasers, or using laser-cooling techniques to extract a slow atomic beam from the background gas in a low-pressure vapor cell. These laser-cooling techniques include "atomic funnels" or two-dimensional magneto-optical traps, as well as a variation of the conventional vapor cell magneto-optical trap called the "low-velocity intense source" (LVIS). Variations of the LVIS have been realized with unique trap geometries such as conical or pyramidal mirror traps. The present work implements a simple and robust design based on the pyramidal trap geometry and allows use of a single large diameter (<less than or = 20 cm) laser beam to obtain large capture rates of atoms from the background vapor. The four 45 deg mirrors are truncated just before the apex of the pyramid, and the 1 sq cm region at the center of the incident laser beam is retro-reflected by lambda /4 plate with a high-reflectance gold coating on the second surface. A small (1 mm diameter) hole in this retro-optic forms an extraction column for the atoms while maintaining a low conductance between the source region and an adjacent UHV chamber.

Kohel, J.↗

Demonstration of a MOT in a sub-millimeter membrane hole

Abstract We demonstrate the generation of a cold-atom ensemble within a sub-millimeter diameter hole in a transparent membrane, a so-called “membrane MOT”. With a sub-Doppler cooling process, the atoms trapped by the membrane MOT are cooled down to 10 $$\upmu$$ μ K. The atom number inside the unbridged/bridged membrane hole is about $$10^4$$ 10 4 to $$10^5$$ 10 5 , and the $$1/e^2$$ 1 / e 2 -diameter of the MOT cloud is about 180 $$\upmu$$ μ m for a 400 $$\upmu$$ μ m-diameter membrane hole. Such a membrane device can, in principle, efficiently load cold atoms into the evanescent-field optical trap generated by the suspended membrane waveguide for strong atom-light interaction and provide the capability of sufficient heat dissipation at the waveguide. This represents a key step toward the photonic atom trap integrated platform (ATIP).

74 ATOMIC AND MOLECULAR PHYSICS↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Cold Atom Source Containing Multiple Magneto-Optical Traps

An apparatus that serves as a source of a cold beam of atoms contains multiple two-dimensional (2D) magneto-optical traps (MOTs). (Cold beams of atoms are used in atomic clocks and in diverse scientific experiments and applications.) The multiple-2D-MOT design of this cold atom source stands in contrast to single-2D-MOT designs of prior cold atom sources of the same type. The advantages afforded by the present design are that this apparatus is smaller than prior designs.

Ramirez-Serrano, Jaime↗

Cold atomic hydrogen in the inner galaxy

The VLA is used to measure 21 cm absorption in directions with the absolute value of b less than 1 deg., the absolute value of 1 less than 25 deg. to probe the cool atomic gas in the inner galaxy. Abundant H I absorption is detected; typical lines are deep and narrow, sometimes blending in velocity with adjacent features. Unlike 21 cm emission not all allowed velocities are covered: large portions of the l-v diagram are optically thin. Although not similar to H I emission, the absorption shows a striking correspondence with CO emission in the inner galaxy: essentially every strong feature detected in one survey is seen in the other. The provisional conclusion is that in the inner galaxy most cool atomic gas is associated with molecular cloud complexes. There are few or no cold atomic clouds devoid of molecules in the inner galaxy, although these are common in the outer galaxy.

Dickey, J. M.↗

Generation of a Cold Atom Beam from a Pyramidal Magneto-Optical Trap

We have built an atomic beam source utilizing a simple and robust design based on the pyramidal trap geometry of Kim et al. Our design allows use of a single large diameter (\le20 cm) laser beam to obtain large capture rates of atoms from a background vapor. A small (about 1mm diameter) hole in the retro-optic at the apex of the pyramid provides an extraction column for the atoms. We have operated the apparatus both as a magneto-optical trap (using an auxiliary plug laser beam), and as a cold atomic beam source. The characterization of this large pyramidal beam source will be reported, including an investigation of scaling to very large (10--20cm) high power (about 1W) laser beams which should allow significant improvements in atomic beam flux.

Bliss, J. L.↗

Preparation for quantum simulation of the ( 1 + 1 ) -dimensional O(3) nonlinear σ model using cold atoms

The 1+1D O(3) non-linear σ-model is a model system for future quantum lattice simulations of other asymptotically-free theories, such as non-Abelian gauge theories. We find that utilizing dimensional reduction can make efficient use of two-dimensional layouts presently available on cold atom quantum simulators. A new definition of the renormalized coupling is introduced, which is applicable to systems with open boundary conditions and can be measured using analog quantum simulators. Monte Carlo and tensor network calculations are performed to determine the quantum resources required to reproduce perturbative short-distance observables. In particular, we show that a rectangular array of 48 Rydberg atoms with existing quantum hardware capabilities should be able to adiabatically prepare low-energy states of the perturbatively-matched theory. Furthermore, these states can then be used to simulate non-perturbative observables in the continuum limit that lie beyond the reach of classical computers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel light field imaging device with enhanced light collection for cold atom clouds

We present a light field imaging system that captures multiple views of an object with a single shot. The system is designed to maximize the total light collection by accepting a larger solid angle of light than a conventional lens with equivalent depth of field. This is achieved by populating a plane of virtual objects using mirrors and fully utilizing the available field of view and depth of field. Simulation results demonstrate that this design is capable of single-shot tomography of objects of size $\mathcal{O}$(1 mm 3 ), reconstructing the 3-dimensional (3D) distribution and features not accessible from any single view angle in isolation. In particular, for atom clouds used in atom interferometry experiments, the system can reconstruct 3D fringe patterns with size $\mathcal{O}$(100 μm). We also demonstrate this system with a 3D-printed prototype. The prototype is used to take images of $\mathcal{O}$(1 mm 3 ) sized objects, and 3D reconstruction algorithms running on a single-shot image successfully reconstruct $\mathcal{O}$(100 μm) internal features. The prototype also shows that the system can be built with 3D printing technology and hence can be deployed quickly and cost-effectively in experiments with needs for enhanced light collection or 3D reconstruction. Imaging of cold atom clouds in atom interferometry is a key application of this new type of imaging device where enhanced light collection, high depth of field, and 3D tomographic reconstruction can provide new handles to characterize the atom clouds.

47 OTHER INSTRUMENTATION↗

Laboratory Apparatus Generates Dual-Species Cold Atomic Beam

A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.

Thompson, Robert↗