Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold district heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal Thermal Energy Storage Program

The Seasonal Thermal Energy Storage (STES) Program designed to demonstrate the storage and retrieval of energy on a seasonal basis using heat or cold available from waste or other sources during a surplus period is described. Factors considered include reduction of peak period demand and electric utility load problems and establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The initial thrust of the STES Program toward utilization of ground water systems (aquifers) for thermal energy storage is emphasized.

Minor, J. E.↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

LNPK 156 Geothermal Coalition: Designing and Deploying Clean Energy in a Justice40 Cold Climate Community

The LNPK 156 Geothermal Coalition formed around the idea of building a new geothermal heating and cooling system in Duluth, MN for the Lincoln Park Justice40 neighborhood. The Coalition has been spearheaded by the City of Duluth and the local non-profit Ecolibrium3, and is named after the census tract of the neighborhood containing large portions of Lincoln Park, as well as a wastewater treatment plant, managed by the Western Lake Superior Sanitary District (WLSSD). The idea of building a geothermal system came to fruition over the period of about a decade, with repeated observations that the warm water discharged from the wastewater treatment plant was an energy-rich resource that has currently been untapped and released into the St. Louis River. The objective of this project was to build a geothermal system that harnesses wastewater heat recovery methods and satisfies the demand in a portion of Lincoln Park – a neighborhood experiencing high energy burdens, low life-expectancy, and where the natural gas and fuel oil used to heat homes and businesses results in decreased air quality and increased carbon emissions. The goal was to utilize this wastewater heat recovery method to benefit the neighborhood hosting the wastewater plant itself.

15 GEOTHERMAL ENERGY↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

Concentrations and Origins of Atmospheric Lead and Other Trace Species at a Rural Site in Northern China

In this study we analyze the ambient levels of lead and other trace species in the bulk aerosol samples from a rural site approx.70 km ESE of Beijing in spring 2005. Lead (0.28+/-0.24 micro-g/cu m, average +/- standard deviation), along with several pollution \related trace elements, was enriched by over 100 fold relative to the Earth's crust. The ambient lead levels showing large synoptic variations were well-correlated with other anthropogenic pollutants (e.g., CO and SO2). The Unmix receptor model resolved four factors in the aerosol composition data: a biomass burning source, an industrial and coal combustion source, a secondary aerosol source, and a dust source. The first three sources were strongest in weak southerly winds ahead of cold fronts, while the dust source peaked in strong northerly winds behind cold fronts. The second source, primarily representing emissions from industrial processes and relatively small \scale coal burning such as in home and institutional heating, was identified as the main source of ambient lead in this study. Mobile sources might also contribute to this factor, but there was no distinct evidence of emissions due to combustion of leaded gasoline, despite a correlation between lead and CO. Potential source contribution function, calculated from backward trajectories and aerosol composition, further reveals that lead observed in this study was predominantly from the populated and industrialized areas to the south and SW of Xianghe, rather than Beijing to the west. Our results and several recent studies show that the lead levels in suburban areas near big cities in China, although generally lower than those in industrial districts and urban areas, are substantial (near or above 0.15 micro-g/cu m). More extensive studies on airborne lead and its emission sources in China are called for.

Li, Can↗

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗