Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Real-World Evaluation of National Energy Efficiency Potential of Cold Storage Evaporator Technology in the Context of Engine Start-Stop Systems

National concerns over energy consumption and emissions from the transportation sector have prompted regulatory agencies to implement aggressive fuel economy targets for light-duty vehicles through the U.S. National Highway Traffic Safety Administration/Environmental Protection Agency (EPA) Corporate Average Fuel Economy (CAFE) program. Automotive manufacturers have responded by bringing competitive technologies to market that maximize efficiency while meeting or exceeding consumer performance and comfort expectations. In a collaborative effort among Toyota Motor Corporation, Argonne National Laboratory (ANL), and the National Renewable Energy Laboratory (NREL), the real-world savings of one such technology is evaluated. A commercially available Toyota Highlander equipped with two-phase cold storage technology was tested at ANL’s chassis dynamometer testing facility. The cold storage technology maintains the thermal state of air-conditioning evaporators to enable longer and more frequent engine-off operation in vehicles equipped with start-stop functionality. Test results were analyzed and provided to NREL where a novel simulation framework was developed and calibrated to the test data. The vehicle model was then exercised over a large set of real-world drive cycle and ambient condition data to estimate national-level fuel economy benefits. Results indicate that the cold storage evaporator provided national fuel consumption reductions of 0.113% relative to a conventional evaporator in the same vehicle. In addition, when the cold storage evaporator engine stop/start was enabled for any temperature and the baseline was limited to the EPA menu, Start and Stop credit assumption of 27°C, a national fuel savings of 0.497% was found. Fuel savings resulted from a combination of extended engine-off duration during idle events and increased frequency of deceleration fuel cutoff, both enabled by the ability of the cold storage evaporator to maintain thermal state in situations where air conditioning is active.

DIRECT ENERGY CONVERSION↗

Holocene cold storage practices on the eastern Snake River Plain: A risk-mitigation strategy for lean times

Previous archaeological research in southern Idaho has suggested that climate change over the past 8000 years was not dramatic enough to alter long-term subsistence practices in the region. However, recent isotopic analyses of bison remains from cold storage caves on the Snake River Plain contest this hypothesis. Our results, when examined against an archaeoclimate model, suggest that cold storage episodes coincided with drier, warmer phases that likely reduced forage and water, and thus limited the availability of bison on the open steppe. Within this context we build a risk model to illustrate how environment might have motivated cold storage behaviors. Caching bison in cold lava tubes would have mitigated both intra-annual and inter-annual food shortages under these conditions. This analysis also suggests that skeletal fat, more than meat, may have influenced the selection, transport and storage of bison carcass parts. We deciphered when and how cold storage caves which was used to provide a more comprehensive understanding of foraging behaviors in a broad range of hunting-gathering economies.

54 ENVIRONMENTAL SCIENCES↗

Use of a silver-based sanitizer to accelerate Escherichia coli die-off on fresh-cut lettuce and maintain produce quality during cold storage: Laboratory and pilot-plant scale tests

Outbreaks and product recalls involving romaine and iceberg lettuce are frequently reported in the United States. Novel technologies are needed to inactivate pathogens without compromising product quality and shelf life. In this study, the effects of a process aid composed of silver dihydrogen citrate, glycerin, and lactic acid (SGL) on Escherichia coli and Listeria monocytogenes concentrations on lettuce immediately after washing and during cold storage were evaluated. Sensory and quality attributes of fresh-cut iceberg lettuce were also evaluated. Laboratory results indicated that application of SGL solution for 30 s as a first step in the washing process resulted in a 3.15 log reduction in E. coli O157:H7 immediately after washing. For E. coli O157:H7 a significant difference between SGL treatment and all other treatments was maintained until day 7. On day zero, SGL led to a 2.94 log reduction of L. monocytogenes. However, there was no significant difference between treatments with or without SGL regardless of storage time. Pilot-plant results showed that samples receiving SGL spray followed by chlorinated flume wash exhibited a greater reduction (1.48 log) in nonpathogenic E. coli populations at the end of shelf life than other treatments (p < 0.05). Additional pilot plant tests were conducted to investigate the hypothesis that SGL residues could continue to impact microbial survival on the final washed lettuce. Results show that pathogens introduced subsequent to flume washing of lettuce pretreated with SGL solution were not affected by antimicrobial residues. Here, the final quality and shelf life of flume washed lettuce were also unaffected by pretreatment with SGL. In conclusion, the results of this study demonstrate that this new technology has the potential to accelerate E. coli die-off on fresh-cut lettuce during cold storage and improve product safety, while not affecting quality throughout the shelf life of the finished products.

59 BASIC BIOLOGICAL SCIENCES↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Cold Spray Deposition of 304L Stainless Steel to Mitigate Chloride-Induced Stress Corrosion Cracking in Canisters for Used Nuclear Fuel Storage

A feasibility study of the cold spray deposition process of 304L stainless steel on 304L stainless steel substrates as a mitigation method for chloride-induced stress corrosion cracking (CISCC) has been investigated under various substrate conditions. The study is aimed at the application of this technology to mitigate CISCC that may potentially occur in or nearthe fusion welded regions of stainless steel canisters in Dry Cask Storage System (DCSS) for used nuclear fuels. Spherical gas-atomized 304L stainless steel powder, in the size range of 25 µm to 44 µm, was used as a feedstock powder for the cold spray process. The powder was deposited on four types of 304L substrates with various surface conditions: as-polished, oxidized, cold-rolled, plates with prototypical CISCC. The effects of cold spray parameters on quality of cold spray coatings were investigated. Thickness, porosity, and phases in the as-deposited materials were evaluated using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and correlated with microhardness and adhesion strength measured via micro-indentation and ASTM C633 pulling test, respectively. XRD analysis of the coatings was also conducted to examine the effects of cold spray condition on residual stress state in the coating. Detailed cross-sectional examination of coating/substrate interfaces was performed with transmission electron microscopy (TEM) equipped with energy dispersive spectroscopy (EDS). Dense and continuous coatings with good adhesion strength and hardness were produced for the various substrate conditions by adjusting cold spray parameters. The results demonstrate that cold spray stainless steel coating is a viable option to provide a physical barrier against CISCC in fusion weld regions of stainless steel in corrosive chloride salt-bearing environments.

Dry Cask Storage Systems, cold spray, 304L stainle↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Single bi-temperature thermal storage tank for application in solar thermal plant

Thermocline storage tanks for solar power systems are disclosed. A thermocline region is provided between hot and cold storage regions of a fluid within the storage tank cavity. One example storage tank includes spaced apart baffles fixed relative to the tank and arranged within the thermocline region to substantially physically separate the cavity into hot and cold storage regions. In another example, a flexible baffle separated the hot and cold storage regions and deflects as the thermocline region shifts to accommodate changing hot and cold volumes. In yet another example, a controller is configured to move a baffle within the thermocline region in response to flow rates from hot and cold pumps, which are used to pump the fluid.

14 SOLAR ENERGY↗

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Cinnamon essential oil vapor alleviates the reduction of aroma-related volatiles in cold-stored “Feicheng” peach using HS-GC-IMS

“Feicheng” peach is popular for its unique aroma, but its defect of being highly sensitive to chilling injury (CI) often leads to aroma loss and internal browning. Essential oils (EOs) are often used to enhance the antioxidant capacity of plants and fruits, as well as to trigger their defense against biotic/abiotic stresses. This study aimed to examine the effect of cinnamon essential oil (CEO) vapor treatment on the aroma quality of peach fruit during cold storage using HS-GC-IMS. The results showed that 50 μL/L CEO vapor reduced the severity of internal browning (IB) in peaches at the stage of 7 ~ 21 d during refrigeration (Significantly, the L * value was higher and the IB index was lower than that of control, p < 0.05). Meanwhile, the evident reduction or loss of aroma content caused by CI was restored to a higher level than the control ( p < 0.05). Furthermore, CEO treatment promoted the release of aroma-related volatiles as evidenced by more propyl acetate, and the dimer of amyl acetate, isoamyl acetate, butyl acetate detected than that on harvest day and no-treated group after 21 d of cold storage plus 2 d of shelf life. Genes of PpLOX1 , PpLOX2 , PpHPL1 and PpADH1 associated with aroma-related volatile biosynthesis revealed higher transcript abundance in peach fruits treated with CEO than the control ( p < 0.05). Overall, our study demonstrated that CEO in vapor phase may be beneficial to alleviate the quality deterioration in aroma and flesh color of “Feicheng” peaches caused by CI, which lays a theoretical reference for maintaining postharvest quality of peach fruits.

Wang, Dan↗

Accelerated Aging of Fast Pyrolysis Bio-Oils

Carbonyl content is a better metric for tracking aging than viscosity. Existing aging test (24 hours @ 80 °C) is too severe, and correlates to more room temperature aging than would realistically occur. New aging test proposed: 2 hours @ 80 °C correlates to 1-3 months of room temperature storage. Aging is slowed in cold storage, but still occurs.

aging↗

SU-E-T-353: Effects of Time and Temperature On a Potential Reusable 3D Dosimeter

Purpose: Preliminary studies of a novel, optically-clearing PRESAGE 3D dosimeter formulation (Presage-RU) demonstrated potential reusability. This study investigates the effects of time and temperature on the accuracy and reusability of Presage-RU, and reports on progress toward developing a reusable 3D dosimeter. Methods: Presage-RU was cast as small volume samples (1×1×4.5cm). The effect of dose response sensitivity with reirradiation and time was evaluated by irradiating samples from 0–10Gy, measuring change in optical density (ΔOD), clearing at room temperature (RT) (5–7 days to fully clear), and then repeating for a total of 5 irradiations. Effects of heating on clearing rate were investigated by irradiating samples to 8Gy, then tracking measurements with samples held at RT, 35°C, and 45°C. Two cylindrical dosimeters (11cm diameter, 9.5cm length) were evaluated for dosimetric accuracy when stored at RT and −3°C prior to irradiation. Plans delivered were 2 overlapping AP fields (RT) and VMAT (-3°C). Results: Heating the dosimeters reduced the clearing half-life from 16.3h at RT to 5.8h (35°C) and 5.1h (45°C), but also increased background ΔOD by 1.7x (35°C) and 2.3x (45°C). Reductions in dose response were more closely linked to age than reirradiation, and storage at RT showed pronounced desensitization from dosimeter edges. These results suggest desensitization from oxygen diffusion. It should be noted that atmospheric diffusion into the dosimeter is not seen in standard, single-use PRESAGE, and is likely caused by differences in the Presage-RU polyurethane matrix. The dosimeter kept in cold storage, however, showed no evidence of desensitization and exhibited accuracy on par with standard PRESAGE with a 3%/3mm 3D gamma passing rate of 98.1%. Conclusions: Presage-RU is sensitive to storage temperatures and time, both of which affect oxygen diffusion and subsequent desensitization. Development shows promising progress with further formulation optimization as the next step toward achieving a successful reusable 3D dosimeter. This work was supported by NIH R01CA100835. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.

60 APPLIED LIFE SCIENCES↗

Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fortalecimiento de la Electrificación Rural en Honduras: Una Evaluación Integrada de PV+BESS y Usos Productivos de la Electricidad en Gracias a Dios, Honduras [Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios] (Spanish Translation)

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH. This is the Spanish translation of NREL/TP-7A40-90865.

14 SOLAR ENERGY↗