Cold Weather Impacts on Electric School Buses
School bus fleets considering electric school buses (ESBs) can start here to learn how cold weather impacts ESBs and considerations for optimizing bus performance when temperatures drop.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
School bus fleets considering electric school buses (ESBs) can start here to learn how cold weather impacts ESBs and considerations for optimizing bus performance when temperatures drop.
Transit fleets exploring the adoption of battery-electric buses (BEBs) can start here to learn about the effects of cold weather and how to enhance bus performance in low temperatures.
This brief highlight details the key takeaways from a project that utilized NLR's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline related to electric school bus (ESB) operation. ESBs using battery energy as their primary heating source have a higher energy consumption rate in cold weather, which fleet managers can account for when planning ESB purchases and making dispatching and charging decisions. Researchers found that electric school buses operate 2-5 times more efficiently than conventional buses, on average. Cold weather can double electric school bus energy demands, but strategies such as thermal pre-conditioning significantly reduce this effect. Understanding these impacts can help fleets plan charging, dispatching, and purchase decisions.
Learn how electric school buses can work for your district by understanding the basics of electrification. Understand what is needed to electrify your fleet, how much it costs, and how the process will effect your greenhouse gas emission impacts.
While the power grid is designed to have an adequate supply of electricity generating capacity under hot and cold conditions well above or below average, weather in recent years has approached the bounds of anticipated conditions, in both magnitude and duration. Extreme weather can result in unanticipated levels of electricity demand and correlated power plant outages driven by extreme temperatures. How power system planners account for the changing role of wind and solar also plays an important role in the power grid's ability to supply enough electricity during extreme weather. In response to recent significant outages, power system planners have been focusing on ensuring methods to evaluate reliability during periods of "net peak demand" consider availability of renewable resources and capture the impact of extreme weather on power plants of all types. In particular, there is significant emphasis on the ability of natural gas-fueled power plants to operate during periods of extreme cold temperatures. The impact of extreme weather on the need to change planning processes is demonstrated in this fact sheet that discusses three significant outages that occurred in recent years.
Abstract Atmospheric fronts embedded in extratropical cyclones are high‐impact weather phenomena, contributing significantly to mid‐latitude winter precipitation. The three vital characteristics of the atmospheric fronts, high wind speeds, abrupt change in wind direction, and rapid translation, force the induced surface waves to be misaligned with winds exclusively behind the cold fronts. The effects of the misaligned waves under atmospheric cold fronts on air‐sea fluxes remain undocumented. Using the multi‐year in situ near‐surface observations and direct covariance flux measurements from the Pioneer Array off the coast of New England, we find that the majority of the passing cold fronts generate misaligned waves behind the cold front. Once generated, the waves remain misaligned, on average, for about 8 hr. The parameterized effect of misaligned waves in a fully coupled model significantly increases the roughness length (185%), drag coefficient (19%), and air‐sea momentum flux (11%). The increased surface drag reduces the wind speeds in the surface layer. The upward turbulent heat flux is weakly decreased by the misaligned waves because of the decrease in temperature and humidity scaling parameters being greater than the increase in friction velocity. The misaligned wave effect is not accurately represented in a commonly used wave‐based bulk flux algorithm. Yet, considering this effect in the current formulation improves the overall accuracy of parameterized momentum flux estimates. The results imply that better representing a directional wind‐wave coupling in the bulk formula of the numerical models may help improve the air‐sea interaction simulations under the passing atmospheric fronts in the mid‐latitudes.
The Department of Energy funded Berkeley Lab to provide technical assistance to two municipal utilities on how energy efficiency and demand flexibility can mitigate the peak demand impacts of building and transportation electrification. Berkeley Lab worked with these utilities, Sacramento Municipal Utility District (SMUD) and Fort Collins Utilities, to identify research questions that supported their planning needs. For both utilities, Berkeley Lab developed scenario-based load forecasts that considered baseline and high-efficiency building electrification. For SMUD, the forecast also explored the sensitivity of peak demand to extreme weather (a winter cold snap) at the system-level. For Fort Collins Utilities, the forecast addressed the impacts of low, medium, and high levels of building and transportation technology adoption on select distribution feeders. Berkeley Lab is also developing a guidance document for utilities that will draw on lessons learned from the technical assistance and provide a framework for conducting similar analyses.
Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.
Abstract Hydrologic processes associated with intermountain cold-season precipitation in the Upper Colorado River basin have important impacts on avalanche forecasting and water resource management. However, traditional weather radar networks struggle with observations in this complex terrain. Data collected during the Study of Precipitation, the Lower Atmosphere, and the Surface for Hydrometeorology (SPLASH) and its sister campaign, Surface Atmosphere Integrated Field Laboratory (SAIL) in the East River watershed of western Colorado, are used to examine a multistorm period from 23 December 2021 to 1 January 2022 that contributed 35% of the total winter precipitation in this watershed. Dual-polarization X-band radar and disdrometer measurements show ∼30-mm differences in precipitation amount at two sites in proximity over four distinct storm events within the period. Wind patterns, synoptic forcings, microphysical characteristics of precipitation, and surface meteorology are analyzed to explain the observed spatial variability of cold-season precipitation in complex mountainous terrain. Analysis shows that differences over time within this event are mainly accounted for by synoptic forcings, such as frontal passages; differences between sites are accounted for by the impact of variations in local wind patterns on precipitation microphysics. Patterns of surface precipitation intensity are compared and found to be correlated with X-band radar signatures; a relationship between a strong dendritic growth stage and intense low-density surface precipitation is reinforced by this study. This relationship demonstrates the importance of particle growth mechanisms on surface snowfall patterns in high-altitude complex terrain, underscoring the importance of realistic microphysical parameterizations. Significance Statement The amount and density of snowpack from western Colorado winter storms have significant impacts on water resources in the Upper Colorado River basin. Snowpack characteristics are affected by small-scale differences in how snow forms in the atmosphere. These differences are hard to study in the complex terrain of the Rockies, but data from the SPLASH and SAIL field campaigns allows us to investigate how snow crystal formation and mountain-driven wind patterns affect snow near the surface. Our study finds that snow crystal growth varies over small space and time scales and is likely controlled by the terrain beneath a given location and resultant local wind patterns. These results imply that predicting snowpack in the Rockies requires properly representing local wind patterns and crystal growth processes in models.
The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.
Understanding how Gulf Stream variation influences cloud morphology is critical for evaluating cloud feedback in the western North Atlantic Ocean and beyond, where mesoscale air-sea interactions dominate. This study investigates the impact of altered mean sea surface temperature (SST) and SST gradients on post-frontal cloud characteristics during cold-air outbreaks, using the Weather Research and Forecasting (WRF) model. Three sensitivity experiments are conducted: a control simulation (default SST), Plus4 (uniform SST increase of 4 K), and Gradplus (SST gradient enhanced by 25 %, centered around mean SST). Results reveal distinctly different responses in boundary layer dynamics and cloud macro-physics. In Plus4, a warmer and moister boundary layer reduces total cloud cover but promotes larger cloud sizes and elongated cloud streets, with diminished liquid water and enhanced ice-phase hydrometeors. Conversely, Gradplus amplifies impacts in the upwind colder SST regions, yielding a drier, colder boundary layer, weaker energy transport, and higher liquid water path but reduced ice water content and cloud lines. Tracer analysis highlights that SST modifications alter airmass sources near cloud tops due to the entrainment of ambient air, with Plus4 amplifying boundary layer contributions to cloud-top regions. These findings underscore the spatially varying effects of SST gradients and mean SST on cloud organization and microphysics, emphasizing the need to resolve ocean-atmosphere coupling in global models to improve the prediction of marine cloud feedback under warming scenarios.
Cold-air outbreak (CAO) clouds in the Arctic are commonly mixed-phase (MP); however, the partitioning of the amount of ice and water in CAO clouds and precipitation is not always well observed. Understanding how cloud phases partition as a function of cloud life cycle is important for predicting snowfall rates, convective life cycle, and intensity at weather timescales. The partitioning into liquid versus ice also has radiative impacts that are consequential for climate. These concerns motivated the incorporation of an airborne G-band vapor radiometer (GVR) into an National Science Foundation-supported aircraft campaign named the Cold Air outbreak Experiment in the Sub-Arctic Region (CAESAR). The GVR is an upward-pointing passive microwave radiometer using four frequencies centered around the 183.31 GHz water vapor absorption line, displaced by +- 1, 3, 7, and 14 GHz. For context, The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility operates a surface-based GVR at its North Slope of Alaska (NSA) site. The same GVR has been used previously for a field campaign in the southeast Pacific, where an offset was noticed between brightness temperatures (Tbs) measured under clear skies compared to those calculated from a radiative transfer model. To account for any calibration offsets to the Tbs, a request was made to DOE to allow the GVR to operate at ARM’s Southern Great Plains (SGP) observatory and enable comparisons between its measurements and those available at SGP. This request was granted, titled ‘UMGVR_CAL’, short for ‘UMGVR_Calibration’. From October 30 to November 10, 2023, the GVR was deployed to the ARM SGP site to take advantage of their regular, nearby radiosonde launches under clear-sky conditions. The latter were determined using the SGP total sky imagery data. The GVR brightness temperatures in these clear-sky conditions were compared to those calculated by a radiative transfer code (PAMTRA) based on the SGP radiosondes. During the campaign, four suitable clear-sky episodes could be used for the GVR calibration. While few in number, these proved to be enough to satisfy our goal.
Increased resolution has enabled kilometer-scale weather and climate models to partially resolve secondary circulations, including horizontal convective rolls (HCRs) and cold pool gust fronts. Although these circulations are ubiquitous in convective boundary layers over land, their impacts on the surface energy balance are largely unknown. Doppler lidar and surface observations were combined with DOE E3SM land model experiments, revealing increased surface winds (5 m/s) and heat fluxes (50 W/m 2 ) in convergent branches of HCRs. Larger wind-driven flux responses (up to 150 W/m 2 ) were found along gust fronts. Surface energy balance shifts to accommodate wind-driven fluxes, reducing ground heat conduction and longwave cooling. Our findings from the US Southern Great Plains are broadly relevant to modeling convective boundary layers. In particular, widely used subgrid wind gust parameterizations were found to be physically inconsistent with resolved secondary circulations and could worsen climate prediction biases at kilometer-scales.
Abstract This study assesses the projected trajectory of Warm Arctic-Cold Continent (WACC) events in East Asia and North America through large ensemble simulation for the upcoming decades. It analyses the evolution of the geographical boundaries of threshold cold temperatures, revealing a significant northward shift as a sign of global warming’s impact on the southward advancement of Arctic cold air. While validating the intensification of the WACC phenomenon until the 2020 s, echoing earlier studies, the findings indicate a marked decrease beginning in the 2030s. If warming is not curbed, this shift suggests a critical modification in the WACC pattern, prompting a re-evaluation of existing theories and models for extreme winter weather events. The results have major implications, spurring communities impacted by WACC to anticipate future changes and encouraging the climate forecasting community to update conceptual models for improved adaptation and mitigation approaches.
Not Available
Anemophilous (wind-driven) pollen is one type of primary biological aerosol particle, which can rupture under high humidity conditions and form smaller sub-pollen particles (SPPs). Both pollen and SPPs can reach the upper troposphere under convective conditions, acting as cloud condensation nuclei (CCN) and ice nucleating particles (INPs), thus influencing cloud formation and precipitation. However, the impacts of these biological aerosols on cold cloud formation and local climate remain unclear as there are large uncertainties on their emission flux and ice nucleating abilities. Here, we incorporate pollen emission and rupture processes in the Weather Research and Forecasting Model with Chemistry (WRF-Chem) simulations and update the Morrison microphysics scheme within WRF-Chem using aerosol-aware INP parameterizations to account for pollen in addition to other anthropogenic and biogenic aerosol. INP parameterizations for pollen and SPP are derived from laboratory experiments. When including pollen rupture rates as observed in a series of chamber studies, SPP concentrations increase, leading to an increase of cloud ice and water by up to 50% and potentially extending the duration of the convective system. Among all simulated hydrometeors, graupel and raindrops exhibit the largest enhancements from the inclusion of SPPs, with intensifying precipitation at the backside of the convective system and a greater spatial extent. Sensitivity simulations indicate that SPPs have a greater effect on cloud microphysical processes than whole pollen grains, and further observational evidence is needed to constrain these processes.
The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.
Abstract Severe convection occurring in high-shear, low-CAPE (HSLC) environments is a common cool-season threat in the southeastern United States. Previous studies of HSLC convection document the increased operational challenges that these environments present compared to their high-CAPE counterparts, corresponding to higher false-alarm ratios and lower probability of detection for severe watches and warnings. These environments can exhibit rapid destabilization in the hours prior to convection, sometimes associated with the release of potential instability. Here, we use self-organizing maps (SOMs) to objectively identify environmental patterns accompanying HSLC cool-season severe events and associate them with variations in severe weather frequency and distribution. Large-scale patterns exhibit modest variation within the HSLC subclass, featuring strong surface cyclones accompanied by vigorous upper-tropospheric troughs and northward-extending regions of instability, consistent with prior studies. In most patterns, severe weather occurs immediately ahead of a cold front. Other convective ingredients, such as lower-tropospheric vertical wind shear, near-surface equivalent potential temperature (θ e ) advection, and the release of potential instability, varied more significantly across patterns. No single variable used to train SOMs consistently demonstrated differences in the distribution of severe weather occurrence across patterns. Comparison of SOMs based on upper and lower quartiles of severe occurrence demonstrated that the release of potential instability was most consistently associated with higher-impact events in comparison to other convective ingredients. Overall, we find that previously developed HSLC composite parameters reasonably identify high-impact HSLC events. Significance Statement Even when atmospheric instability is not optimal for severe convective storms, in some situations they can still occur, presenting increased challenges to forecasters. These marginal environments may occur at night or during the cool season, when people are less attuned to severe weather threats. Here, we use a sorting algorithm to classify different weather patterns accompanying such storms, and we distinguish which specific patterns and weather system features are most strongly associated with severe storms. Our goals are to increase situational awareness for forecasters and to improve understanding of the processes leading to severe convection in marginal environments.