Small-scale validation tests for MFIX-Exa CFD-DEM
This report describes several bench-scale fluidization experiments that can be used to validate the CFD-DEM method as encapsulated in the MFIX-Exa code. The five cases considered are the cold-flow fluidized beds of Müller et al., Link et al. (spout-fluid), and Goldschmidt et al. (bi-disperse), the hot fluidized bed of Patil et al., and the adsorbing fluidized bed of Li et al. and Janssen. In most cases, MFIX-Exa with “standard” or “typical” CFD-DEM settings, the Gidaspow drag model, and the Gunn heat transfer provide a relatively good prediction of the quantities considered: mean void fraction profiles, mean velocity profiles, fluctuating velocity profiles, mean particle temperature and segregation index. These results, with other verification and validation tests reported elsewhere, contribute to a body of work providing confidence and credibility in CFD predictions from the MFIX-Exa code.