Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Collimator challenges at SuperKEKB and their countermeasures using nonlinear collimator

In SuperKEKB, movable collimators reduce the beam background noise in the Belle II particle detector and protect crucial machine components, such as final focusing superconducting quadrupole magnets (QCS), from abnormal beam losses. The challenges related to the collimator, which were not properly considered at the time of SuperKEKB design, have surfaced through experience with its operation. In this paper, we report the collimator operation strategy in SuperKEKB. In addition, a significant challenge of beam collimation due to the future increase in the beam background is highlighted. We also discuss another issue caused by unexpected and sudden beam losses in the machine that damage collimators, leading to weaker beam collimation performance and an increase in transverse impedance. Furthermore, we introduce a novel collimation approach called the nonlinear collimator (NLC) to address these challenges. We detail the concept of NLC and evaluate their effectiveness by assessing the collimator impedance, beam background reduction, and impact on the dynamic aperture. The possibility of using NLCs as absorber collimators to counteract events that damage the collimator is also shown to be helpful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A rotor-based multileaf collimator for beam shaping

We introduce a new style of multileaf collimator which employs rotors with angularly dependent radius to control the masking aperture: a rotor-based multileaf collimator (RMLC). Using a padlock-inspired mechanism, a single motor can set dozens of rotors, i.e. leaves, independently. This is especially important for an ultra-high vacuum (UHV) compatible MLC, since this reduces the number of actuators and vacuum feedthroughs required by more than an order of magnitude. This new RMLC will complement previous work employing a UHV compatible MLC with an emittance exchange beamline to create arbitrarily shaped beams on demand. A feed-forward control system which abstracts away the complexity of the RMLC operation, and is adaptable to real beamline conditions, is discussed and demonstrated in simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimation Systems for the PSR

This note provides a review of collimator systems being used or considered in high-intensity proton accelerators like SNS, J-PARC, LHC, and PIP-II. These facilities use collimators to remove beam halo, restrict transverse size and momentum in the beam to constrain beam losses around collimators and minimize beam losses downstream, particularly losses arising from particles missing the design location at the stripping foil when injected into the proton storage ring. Collimators are placed either in the transport injection lines (single-pass collimators) or in the rings (multi-pass collimators). Collimators in the transport line are placed around stripping foils in H- accelerators, allowing the beamline optics to get rid of the unstripped protons into well localized absorbers. Rings and proton accelerators mostly rely on tungsten scrapers and collimators in a multi-stage configuration to clean the scattered beam particles mainly responsible for heavy losses at high energies. Placement of the collimators is carefully chosen in terms of the right phase advance to maximize the collimating efficiency, whether the collimation is intended to match an injection stripping foil or a downstream acceptance. Collimation systems are designed with the specific concerns of each facility in mind, although all of them prioritize the minimization of activation due to beam losses to enable hands-on access during maintenance periods. At LANSCE, there are no high-energy collimators, although pairs of horizontal and vertical jaws are routinely used in the LEBT to clean and control the transverse beam profile delivered downstream. This report will help in understanding, together with the beam dynamics simulations, which collimation schemes would be most effective for the PSR upgrade. For example, SNS designed off-momentum collimators to be placed in a 90° arc bend, a high-dispersion region in the beam injection line, very similar to the bend at Line D in LANSCE. This system was very effective at minimizing losses during injection into the SNS accumulator ring and is being re-designed for future operation.

43 PARTICLE ACCELERATORS↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

Advanced manufacturing of 3D custom boron-carbide collimators designed for complex environments for neutron scattering

Scattered-beam collimation is a very useful method to reduce unwanted backgrounds and to boost the desired sample signal instead. This approach is of particular interest for samples contained within a complex environment that gives rise to much unwanted parasitic scatter. As neutron scattering instrument and techniques advances, small samples are becoming of more and more interest, which necessitates optimized collimation. Here, in this work, we describe a concept for the design and fabrication of advanced scattered-beam collimation 3D printed from B 4 C specifically tailored for samples contained within a complex environment. This concept is demonstrated through the use of a diamond anvil cell for high pressure experimentation, a technique that very typically requires small samples. The collimators here are designed through a modeling procedure via Monte Carlo neutron ray tracing that encompasses the entire system: the instrument, the complex environment and the collimator. Since the first approach of simply scaling up of the print-size was not successful, a novel concept of a multi-part alternate-blade collimator was developed. This approach addresses printing constraints but gives greater flexibility in design. Its performance is computationally compared against an unprintable progressively tighter blade collimator to assess the effect of alternating blades. No strong difference was observed. Its performance was validated through experimentation at the Spallation Neutron Source. The results emphasize the critical importance of ultra-high precision alignment while showing good overall agreement between simulation and experiment and underscore the feasibility of the method and its real-world application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High energy collimating fine grids

The objective of this project was to demonstrate the fabrication of extremely tight tolerance collimating grids using a high-Z material, specifically tungsten. The approach taken was to fabricate grids by a replication method involving the coating of a silicon grid substrate with tungsten by chemical vapor deposition (CVD). A negative of the desired grid structure was fabricated in silicon using highly wafering techniques developed for the semiconductor industry and capable of producing the required tolerances. Using diamond wafering blades, a network of accurately spaced slots was machined into a single-crystal silicon surface. These slots were then filled with tungsten by CVD, via the hydrogen reduction of tungsten hexafluoride. Following tungsten deposition, the silicon negative was etched away to leave the tungsten collimating grid structure. The project was divided into five tasks: (1) identify materials of construction for the replica and final collimating grid structures; (2) identify and implement a micromachining technique for manufacturing the negative collimator replicas (performed by NASA/JPL); (3) develop a CVD technique and processing parameters suitable for the complete tungsten densification of the collimator replicas; (4) develop a chemical etching technique for the removal of the collimator replicas after the tungsten deposition process; and (5) fabricate and deliver tungsten collimating grid specimens.

Arrieta, Victor M.↗

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗

First experimental report of nonlinear collimator in the SuperKEKB

SuperKEKB collimator system protects the superconducting final focusing magnets (QC1 and QC2) from quenching caused by beam halo particles. For effective shielding, the minimum aperture of vertical collimators is set smaller than the physical aperture of QC1. However, such collimators become dominant sources of beam coupling impedance, which can limit the maximum beam current due to impedance-driven instabilities. To address this issue, a nonlinear collimator (NLC) was introduced in February 2024. NLC is designed to reduce both beam backgrounds and collimator impedance, thereby suppressing beam instabilities caused by short-range wakefields. In this paper, we describe the results on impedance effects, beam background reduction, and beam lifetime when the nonlinear collimation system is turned on and off. These results validate the NLC concept and offer a promising approach for future high-luminosity colliders.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Optimizing collimator positions using bayesian optimization in the Fermilab MI-8 transfer line

Collimators are used to minimize losses and to remove particles that would otherwise get lost downstream and irradiate the machine. Finding the optimal jaw positions is time consuming and with the upstream beam properties changing, the collimation settings would need to be readjusted each time. Therefore, a method to optimize collimator positions and to operate them at full capacity in a short time is required for loss control downstream. A study of collimator positions was conducted and a machine learning (ML) model was developed to predict optimal collimator positions. Bayesian Optimization (BO) was used to calculate new jaw positions from the ML model. The results of BO and usage of ML for better performance of the collimation system are presented in this paper.

Babacan, Betiay [Fermilab]↗

Design and fabrication of multigrid X-ray collimators

The paper considers the design and fabrication of multigrid collimators for use in X-ray astronomy. The most important collimator performance criteria are minimum off-band transmission or leakage, and maximum on-band transmission. Lockheed experience with multigrid collimator is summarized: (1) an Oda type with one-dimensional collimation of 1.7 arc minute FWHM and using only the central transmission band, (2) an Oda type with 2 arc minute one-dimensional collimation using up to 27 transmission bands, each separated by 42 arc min. and (3) a modified Parkinson type with two-dimensional collimation of 40 arc sec. Attention is given to grid materials, precision, plating, hole quality, and results of acceptance testing.

Acton, L. W.↗

A Novel Two Stage Collimation Unit for Fermilab Booster

A new two-stage collimation unit (2SC) for Fermilab Booster will be installed during 2024 summer shutdown. It is a supplementary collimator for existing single stage Booster collimators. Design details of this 2SC adapted to Booster conditions are described. Results of beam dynamics simulations on collimation efficiency and evaluation of collimator shielding with MARS code on this new system are presented. The analysis on beam dynamics shows that the system will help to collimate up to about 1% of the beam in a confined way and, prompt and residual activation meet Fermilab Radiological Control limits in current as well as during PIP-II era high intensity operation of the Booster.

43 PARTICLE ACCELERATORS↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗