Search NASA⌕ Search

SEARCH · Search NASA

Results for “color fidelity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Chroma Shift and Gamut Shape: Going Beyond Average Color Fidelity and Gamut Area

Though sometimes referred to as a two-measure system for evaluating color rendition, IES TM-30-15 includes other key components that go beyond the high-level average values IES Rf and IES Rg. This article focuses on the Color Vector Graphic and Local Chroma Shift (IES Rcs,hj), discussing the calculation methods for these evaluation tools and providing context for the interpretation of the values. It also presents alternatives for quantifying the same characteristics, which can inform the development of future measures. The Color Vector Graphic (CVG) is a visual representation of hue and chroma shifts across different hues. It quickly communicates complex information about how object colors will be rendered by a light source, although it is difficult or impossible to use for writing a specification. CVGs demonstrate that increases in chroma for certain hues sometimes means a decrease in chroma for other hues, and illustrates hue shifts for intermediate colors. The combination of shifts over different hues can be referred to as gamut shape. Complementing this information are the IES Rcs,hj values, which quantify the average relative chroma shift for samples in each of the 16 hue-angle bins (j) specified in IES TM-30-15. Unlike measures of average color fidelity and gamut area, gamut shape and hue-specific chroma shift are new concepts with no directly-comparable historical references. It will be critical to incorporate the Color Vector Graphic and Local Chroma Shift values into practice because they capture information about color rendition that is impossible to describe with average measures (such as CIE Ra, IES Rf, or IES Rg), but that is critical to understanding human evaluations of color quality in architectural environments.

Chroma Shift↗

Comparing Measures of Average Color Fidelity

The introduction of new measures of color rendition, especially IES TM-30-15, has stirred debate within the lighting industry on the relative merits of the tools, as well as the amount of difference between the new tools and prior tools, such as CIE Ra. This article focuses on comparing three measures of average color fidelity: IES Rf, CIE Ra, and CIE Rf. Using a large set of commercially-available, experimental, and theoretical spectral power distributions (SPDs), the analysis contrasts past efforts to make similar comparisons using smaller or more focused datasets. It highlights the interactive effect of gamut shape and color space non-uniformity, which results in a range of IES Rf values of at least to 50 to 86 for SPDs having a CIE Ra value of 80. It also examines how these differences can be overlooked in psychophysical experiments relying on a small number of SPDs, which can present misleading findings on the value and meaning of the measures. When considering the results, it is important to remember that average color fidelity is only one aspect of color rendition.

Royer, Michael P.↗

Development of the IES method for evaluating the color rendition of light sources

We have developed a two-measure system for evaluating light sources’ color rendition that builds upon conceptual progress of numerous researchers over the last two decades. The system quantifies the color fidelity and color gamut (change in object chroma) of a light source in comparison to a reference illuminant. The calculations are based on a newly developed set of reflectance data from real samples uniformly distributed in color space (thereby fairly representing all colors) and in wavelength space (thereby precluding artificial optimization of the color rendition scores by spectral engineering). The color fidelity score R f is an improved version of the CIE color rendering index. The color gamut score R g is an improved version of the Gamut Area Index. In combination, they provide two complementary assessments to guide the optimization of future light sources. This method summarizes the findings of the Color Metric Task Group of the Illuminating Engineering Society of North America (IES). It is adopted in the upcoming IES TM-30-2015, and is proposed for consideration with the International Commission on Illumination (CIE).

47 OTHER INSTRUMENTATION↗

Color Rendering: What do we want?

This article is for LD+A. It describes the difference between color fidelity and color preference, and explores so hypotheses for why we don't always prefer high fidelity lighting.

Color rendering↗

Evaluating tradeoffs between energy efficiency and color rendition

Color rendition and energy efficiency have long been considered characteristics of light sources that cannot be maximized simultaneously. The tradeoff has been studied extensively, but usually considering only average color fidelity. This work examines the color rendition versus energy efficiency tradeoff in the context of ANSI/IES TM-30-18, Method for Evaluating Light Source Color Rendition, which provides numerous measures beyond average color fidelity. The analysis demonstrates that color rendition criteria based on combinations of ANSI/IES TM-30-18 values can be used to improve color quality with less of an effect on spectral efficiency (luminous efficacy of radiation) than increasing CIE Ra alone. No change in the direction of LED emitter or downconverter development is needed.

Royer, Michael P.↗

PNNL Report: New Study Validates Color-Rendition Specification Criteria Based on TM-30

Pacific Northwest National Laboratory (PNNL) has released the results of a study – published in Lighting Research & Technology – that validates color-preference specification criteria based on ANSI/IES TM-30-18. The result provides additional data to support TM-30 Annex E (in press), which will include tiers of recommended specification criteria for different goals (color preference, color vividness, and color fidelity), among other information related to color rendition specification. Standardized methods for evaluating the color rendition of light sources have progressed rapidly in the past five years, beginning with the publication of IES TM-30-15, followed by the adoption of CIE 224:2017, and culminating with the issuance of ANSI/IES TM-30-18 (which revised TM-30-15, made it a national standard, and unified the calculation framework of CIE 224 and IES TM-30). Importantly, none of these documents provided guidance on how to specify color rendition using the included measures; that is, no value or combination of values was identified that leads to any desired quality of the light. Dozens of experiments over the past 60 years have examined subjective evaluations of color quality—such as preference, naturalness, or vividness—although the focus has traditionally been on developing a single-number color quality metric rather than specification criteria. Further, many of these pre-LED and pre-TM-30 studies were limited in their ability to vary the lighting characteristics, preventing them from generating a complete and accurate picture of what influences color rendering quality in architectural spaces. A renewed emphasis in this area of research over the past four years has yielded a growing consensus about how measures of color fidelity (Rf), gamut area (Rg), and red chroma (Rcs,h1) can be used in combination to effectively describe several important perceptual attributes. In the new study, which was the third in a series conducted at PNNL, 90 lighting conditions with systematically varied color rendition and chromaticity were evaluated by 25 participants, who provided ratings for normalness, saturation, preference, and acceptability. The lighting conditions were specifically designed to test the bounds of previously proposed color preference criteria, while simultaneously verifying the applicability of the criteria across different values of CCT and Duv. In line with the preceding work, there were substantial differences in ratings based on color rendition, but minimal differences based on chromaticity. The tested criteria performed well, although after the experiment, some small adjustments in lower limits provided more effective divisions between tiers of performance. The adjusted criteria are: • Level 1: Rf = 78, Rg = 95, -1% = Rcs,h1 = 15% • Level 2: Rf = 74, Rg = 92, -7% = Rcs,h1 = 19% • Level 3: Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. These criteria were concurrently checked against the results from other, independent experiments, and will be included in ANSI/IES TM-30 Annex E as the specifications for color preference. The new criteria will be a valuable tool for improving lighting quality and balancing the tradeoff between color rendition and energy efficiency.

Royer, Michael P.↗

Experiment M410: Color patch photography

A slate that supported four calibrated color targets was photographed during Gemini 10 mission extravehicular activity to determine if existing outdoor-type color films can reproduce colored objects accurately in the space environment. The experiment resulted in the acquisition of sufficient information to confirm that objects can be photographed in space with good color fidelity by the use of existing materials. Available color film is balanced to the solar spectrum in space, and the effect of ultraviolet energy on film degradation appears to be negligible.

Brinkmann, J. R.↗

Tunability of the circadian action of tetrachromatic solid-state light sources

An approach to the optimization of the spectral power distribution of solid-state light sources with the tunable non-image forming photobiological effect on the human circadian rhythm is proposed. For tetrachromatic clusters of model narrow-band (direct-emission) light-emitting diodes (LEDs), the limiting tunability of the circadian action factor (CAF), which is the ratio of the circadian efficacy to luminous efficacy of radiation, was established as a function of constraining color fidelity and luminous efficacy of radiation. For constant correlated color temperatures (CCTs), the CAF of the LED clusters can be tuned above and below that of the corresponding blackbody radiators, whereas for variable CCT, the clusters can have circadian tunability covering that of a temperature-tunable blackbody radiator.

43 PARTICLE ACCELERATORS↗

Three beam-combining schemes in a color projection display

Several beam-combining schemes for on-axis and off-axis optical system layout are presented. The on-axis approaches include two crossed plates with dichroic coatings placed at 90 deg, with respect to each other, and a pentaprism arrangement. The off-axis layout of the cathode ray tubes requires that the images be combined at the display screen. These image-combining approaches are compared for the standard television rates of 525 lines and the high-resolution television at 1200/2000 lines under development in Japan. It is concluded that, for the high-performance, high-color fidelity, and high-resolution projection systems, which are expected to fit into a small volume of space such as a Space Station display or a cockpit panoramic display, a folded configuration with either crossed plates or pentaprism plates will result in an optimum color display.

Scholl, Marija S.↗

LEDs for Extraterrestrial Agriculture: Tradeoffs between Color Perception and Photon Efficacy

Growing food on extraterrestrial surfaces requires the development of efficient lighting technologies to provide photons for photosynthesis. Here we discuss the development and demonstration of LED panels with a high color fidelity index that can achieve a photon efficacy of 3.6 µmol of photons per joule of input electrical energy. As of June 2021, this is higher than commercial LED fixtures on Earth. This high efficacy makes LED technology a preferred option to solar fiber optics for extraterrestrial applications. Increasing the fraction of red LEDs and photons increases the efficacy but decreases the perception of color.

Bioregenerative↗

Correlated color temperature is not a suitable proxy for the biological potency of light

Using a simulation based on a real, five-channel tunable LED lighting system, we show that Correlated Color Temperature (CCT) is not a reasonable predictor of the biological potency of light, whether characterized with CIE melanopic Equivalent Daylight Illuminance (mel-EDI), Equivalent Melanopic Lux (EML) (a scalar multiple of mel-EDI), or Circadian Stimulus (CS). At a photopic corneal illuminance of 300 lx and Rf ≥ 70, spectra can vary in CS from 17 to 41% across CCTs from 2500 to 6000 K, and up to 23% at a single CCT, due to the choice of spectrum alone. The CS range is largest, and notably discontinuous, at a CCT of 3500 K, the location of the inflection point of the CS model. At a photopic corneal illuminance of 300 lx and Rf ≥ 70, mel-EDI can vary from 123 to 354 lx across CCTs from 2500 to 6000 K and can vary by up to 123 lx at a fixed CCT (e.g., 196 to 319 lx at 5000 K). The range of achievable mel-EDI increases as CCT increases and, on average, decreases as color fidelity, characterized with IES TM-30 Rf, increases. These data demonstrate that there is no easy mathematical conversion between CS and mel-EDI when a spectrally diverse spectra set of spectral power distributions is considered.

60 APPLIED LIFE SCIENCES↗

What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of the CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.

CAM02-UCS↗

EMPLOYING A NEW, BVI{sub c} PHOTOMETRIC SURVEY OF IC 4665 TO INVESTIGATE THE AGE OF THIS YOUNG OPEN CLUSTER

We present a new, BVI{sub c} photometric survey of the young open cluster IC 4665, which improves on previous studies of this young cluster by incorporating a rigorous standardization procedure, thus providing high-fidelity colors and magnitudes for cluster members. We use this new photometric dataset to reevaluate the properties (age and distance) of IC 4665. Namely, using a statistical approach incorporating {tau}{sup 2} color-magnitude diagram modeling, we measure a pre-main-sequence (PMS) isochrone age and distance of 36 {+-} 9 Myr and 360 {+-} 12 pc, as well as an upper-main-sequence turn-off age and distance of 42 {+-} 12 Myr and 357 {+-} 12 pc. These ages and distances are highly dependent on the isochrone model and color used for the fitting procedure, with a possible range of {approx}10-20 Myr in age and {approx}20 pc in distance. This spread in calculated ages and distances seen between colors and models is likely due to limitations in the individual membership catalogs and/or systematic differences in the predicted stellar parameters from the different sets of models. Interestingly, when we compare the isochrone ages for IC 4665 to the published lithium depletion boundary (LDB) age, 28 {+-} 5 Myr, we observe that this cluster does not appear to follow the trend of isochrone ages being 1.5 times smaller than LDB ages. In addition, comparing the overall magnetic activity (X-ray and H{alpha} emission) in IC 4665 with other well-studied open clusters, we find that the observed activity distributions for this young cluster are best characterized by assuming an age of 30-40 Myr, thus in agreement with our PMS and turn-off isochrone ages for IC 4665. Overall, although some age discrepancies do exist, particularly in the ages measured from PMS isochrones, the range of possible IC 4665 ages derived from the various dating techniques employed here is relatively small compared to that found for other well-studied open clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Correspondence: In support of the IES method of evaluating light source colour rendition

In this editorial, written as an open letter to the lighting community, we stand in support of widespread adoption of TM-30-15: The IES Method of Evaluating Light Source Color Rendition. We introduce important considerations related to light source color rendition, define the need for a new method of evaluation, provide a high-level overview of the IES method, discuss some of the practical considerations related to the development of the IES method and the consensus process, and conclude by inviting you to join us in support of the new measures and graphics described in TM-30-15.

36 MATERIALS SCIENCE↗

Application Summary Report 22: LED MR16 Lamps

This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens, or the approximate equivalent of a 50 W halogen MR16 lamp. Many factors beyond photometric performance should be considered during specification. For example, performance over time, transformer and dimmer compatibility, and total system performance are all critical to a successful installation. Subsequent CALiPER reports will investigate more complex issues.

CALiPER↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of short-term exposure to stereoscopic three-dimensional flight displays on real-world depth perception

High-fidelity color pictorial displays that incorporate depth cues in the display elements are currently available. Depth cuing applied to advanced head-down flight display concepts potentially enhances the pilot's situational awareness and improves task performance. Depth cues provided by stereopsis exhibit constraints that must be fully understood so depth cuing enhancements can be adequately realized and exploited. A fundamental issue (the goal of this investigation) is whether the use of head-down stereoscopic displays in flight applications degrade the real-world depth perception of pilots using such displays. Stereoacuity tests are used in this study as the measure of interest. Eight pilots flew repeated simulated landing approaches using both nonstereo and stereo 3-D head-down pathway-in-the-sky displays. At this decision height of each approach (where the pilot changes to an out-the-window view to obtain real-world visual references) the pilots changed to a stereoacuity test that used real objects. Statistical analysis of stereoacuity measures (data for a control condition of no exposure to any electronic flight display compared with data for changes from nonstereo and from stereo displays) reveals no significant differences for any of the conditions. Therefore, changing from short-term exposure to a head-down stereo display has no more effect on real-world relative depth perception than does changing from a nonstereo display. However, depth perception effects based on sized and distance judgements and on long-term exposure remain issues to be investigated.

Busquets, Anthony M.↗

Vertical Isolation for Photodiodes in CMOS Imagers

In a proposed improvement in complementary metal oxide/semi conduct - or (CMOS) image detectors, two additional implants in each pixel would effect vertical isolation between the metal oxide/semiconductor field-effect transistors (MOSFETs) and the photodiode of the pixel. This improvement is expected to enable separate optimization of the designs of the photodiode and the MOSFETs so as to optimize their performances independently of each other. The purpose to be served by enabling this separate optimization is to eliminate or vastly reduce diffusion cross-talk, thereby increasing sensitivity, effective spatial resolution, and color fidelity while reducing noise.

Pain, Bedabrata↗