Search NASA⌕ Search

SEARCH · Search NASA

Results for “color quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Beam Quality↗

CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank-ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members' ranking of color quality did not always match the rank according to the color rendering index (CRI).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mining Unexplored Chemistries for Phosphors for High-Color-Quality White-Light-Emitting Diodes

There is a critical need for new earth-abundant phosphors to enable next-generation, highly efficient solid-state lighting. Here we report the discovery of Sr 2 LiAlO 4 , the first known Sr-Li-Al-O quaternary crystal, via a carefully targeted data-driven structure prediction and screening effort using density functional theory calculations. Sr 2 LiAlO 4 is predicted and experimentally confirmed to be a thermodynamically and thermally stable phosphor host that can be excited with near-UV/blue sources. The Eu 2+ - and Ce 3+ -activated Sr 2 LiAlO 4 phosphors exhibit broad emissions at λ max ~ 512 nm (green-yellow) and λ max ~ 434 nm (blue), respectively, with excellent thermal quenching resistance of >88% intensity at 150°C. A prototype phosphor-converted white LED utilizing Sr 2 LiAlO 4 -based phosphors yields an excellent color-rendering index exceeding 90. Sr 2 LiAlO 4 therefore exhibits great potential for industrial applications in low-cost, high-color-quality WLEDs.

Wang, Zhenbin↗

Phosphorescent Pt(II) and Pd(II) Complexes for Efficient, High-Color-Quality, and Stable OLEDs

Phosphorescent organic light-emitting diodes (OLEDs) are leading candidates for next-generation displays and solid-state lighting technologies. Much of the academic and commercial pursuits in phosphorescent OLEDs have been dominated by Ir(III) complexes. Over the past decade recent developments have enabled square planar Pt(II) and Pd(II) complexes to meet or exceed the performance of Ir complexes in many aspects. In particular, the development of N-heterocyclic carbene-based emitters and tetradentate cyclometalated Pt and Pd complexes have significantly improved the emission efficiency and reduced their radiative lifetimes making them competitive with the best reported Ir complexes. Furthermore, their unique and diverse molecular design possibilities have enabled exciting photophysical attributes including narrower emission spectra, excimer -based white emission, and thermally activated delayed fluorescence. These developments have enabled the fabrication of efficient and “pure” blue OLEDs, single-doped white devices with EQEs of over 25% and high CRI, and device operational lifetimes which show early promise that square planar metal complexes can be stable enough for commercialization. These accomplishments have brought Pt complexes to the forefront of academic research. The molecular design strategies, photophysical characteristics, and device performance resulting from the major advancements in emissive Pt and Pd square planar complexes are discussed.

36 MATERIALS SCIENCE↗

Four-color laser white illuminant demonstrating high color-rendering quality

Solid-state lighting is currently based on light-emitting diodes (LEDs) and phosphors. Solid-state lighting based on lasers would offer significant advantages including high potential efficiencies at high current densities. Light emitted from lasers, however, has a much narrower spectral line-width than light emitted from LEDs or phosphors. Therefore it is a common belief that white light produced by a set of lasers of different colors would not be of high enough quality for general illumination. We tested this belief experimentally, and found the opposite to be true. This result paves the way for the use of lasers in solid-state lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Definition Television (HDTV) Images for Earth Observations and Earth Science Applications

As part of Detailed Test Objective 700-17A, astronauts acquired Earth observation images from orbit using a high-definition television (HDTV) camcorder, Here we provide a summary of qualitative findings following completion of tests during missions STS (Space Transport System)-93 and STS-99. We compared HDTV imagery stills to images taken using payload bay video cameras, Hasselblad film camera, and electronic still camera. We also evaluated the potential for motion video observations of changes in sunlight and the use of multi-aspect viewing to image aerosols. Spatial resolution and color quality are far superior in HDTV images compared to National Television Systems Committee (NTSC) video images. Thus, HDTV provides the first viable option for video-based remote sensing observations of Earth from orbit. Although under ideal conditions, HDTV images have less spatial resolution than medium-format film cameras, such as the Hasselblad, under some conditions on orbit, the HDTV image acquired compared favorably with the Hasselblad. Of particular note was the quality of color reproduction in the HDTV images HDTV and electronic still camera (ESC) were not compared with matched fields of view, and so spatial resolution could not be compared for the two image types. However, the color reproduction of the HDTV stills was truer than colors in the ESC images. As HDTV becomes the operational video standard for Space Shuttle and Space Station, HDTV has great potential as a source of Earth-observation data. Planning for the conversion from NTSC to HDTV video standards should include planning for Earth data archiving and distribution.

Robinson, Julie A.↗

Opinion: Making the Most of Colour Rendition Research

After decades of debate, new methods for characterizing color rendition have been formalized, providing an improved system of tools to aid technology developers and lighting specifiers. Solid-state lighting, previously burdened by legacy measures based on outdated science, is positioned to take advantage of these new tools to provide tailored, efficient lighting that better meets the needs of specific architectural lighting applications. This transition requires new guidance, however, presenting an opportunity for researchers. There are several key methodological considerations specific to experiments investigating color rendition that will help build a base of guidance that can be widely applied. The importance of these ideas mostly stems from new knowledge gained in the last five years, but their origins date back much further. 1.The spectral power distribution must be adequately varied to stress the measure(s) of color rendition being evaluated. Often, this means varying the gamut shape—the pattern of shift across different hues—to probe weaknesses of hue-averaged characterizations, avoiding misleading conclusions resulting from limited variation in the stimuli. 2.Evaluating the role of chromaticity on color quality evaluations requires careful accommodation of chromatic adaptation to prevent a centering bias. Asking for delayed responses may be insufficient if chromaticity changes are apparent to participants, just as side-by-side viewing of different chromaticities may not produce results that can be reliably applied in the field. It is also critical that color rendition and chromaticity conditions are varied independently. 3.The stimulus being viewed is the interaction of light and objects’ spectral reflectances. This interaction should be quantified in order to assess how derived guidelines will apply measures using standardized color sample sets. Although light source characterizations are typically used to model responses, the objects and their presentation may strongly influence evaluations. 4.Context is important. Many factors—some investigated, others hypothesized—can influence subjective evaluations of color quality, including illuminance level, type of scene, object familiarity, color composition, viewing duration, and viewer traits. Although their influence on research results is unavoidable, the effects of these contextual factors must be carefully considered in developing guidance. Appropriate experimental design can often mitigate negative consequences arising from these considerations. At a minimum, it is crucial to understand how each of these considerations can influence experimental outcomes, as well as the interpretation and application of the results in practice. Consulting other experts prior to conducting an experiment can help ensure appropriate, up-to-date research methods will be used, so that the results will be novel and useful—and not rejected during peer review. There is an interesting feedback loop: technology development provides new research tools, which allow for refined research methods and new results that lead to more technology development. It is time to make a concerted, collective effort to improve color rendition research so that the full potential of solid-state lighting and new characterization methods can be realized, ensuring that high-efficiency, high-utility, high-appeal lighting systems become standard.

Royer, Michael P.↗

A method and tool to determine the colorimetric and photobiological properties of light transmitted through glass and other optical materials

Here we describe a framework and provides a computational tool to characterize the color quality and biological potential of light that is transmitted through glass and other optical materials. The IES TM-30 framework and Excel computation tool were adapted to evaluate color quality, with measures from CIE S 026, UL 24480, and the WELL Building Standard v2 added to evaluate biological potential. The user selects a pre-transmittance spectral power distribution (SPD), such as for a CIE D-Series Illuminant, Planckian radiation, electric lamp, or measurement of daylight at a building site. The tool allows a user to populate a database with spectral data for glazing or other optical materials, comprising spectral transmission and the spectral reflectance of both sides. The user creates a unit with one, two, or three panes of glazing or other optical materials, and the tool calculates the composite spectral transmittance accounting for reflections between materials. The tool computes the transmitted SPD, then determines colorimetric and photobiological outputs using the transmitted SPD as the test source. Glass, window, and skylight manufacturers can employ the tool to optimize glazing spectral transmission to achieve intentional colorimetric and photobiological performance with transmitted light. Electric lighting manufacturers, designers, and researchers can use the tool to evaluate the impact of glazing units and other optical materials on the color quality and biological potential of transmitted light.

36 MATERIALS SCIENCE↗

Scalable, Economical Fabrication Processes for Ultra-Compact Warm-White LEDs

Conventional warm-white LED component fabrication consists of a large number of sequential steps which are required to incorporate electrical, mechanical, and optical functionality into the component. Each of these steps presents cost and yield challenges which multiply throughout the entire process. Although there has been significant progress in LED fabrication over the last decade, significant advances are needed to enable further reductions in cost per lumen while not sacrificing efficacy or color quality. Cree conducted a focused 18-month program to develop a new low-cost, high-efficiency light emitting diode (LED) architecture enabled by novel large-area parallel processing technologies, reduced number of fabrication steps, and minimized raw materials use. This new scheme is expected to enable ultra-compact LED components exhibiting simultaneously high efficacy and high color quality. By the end of the program, Cree fabricated warm-white LEDs with a room-temperature “instant on” efficacy of >135 lm/W at ~3500K and 90 CRI (when driven at the DOE baseline current density of 35 A/cm2). Cree modified the conventional LED fabrication process flow in a manner that is expected to translate into simultaneously high throughput and yield for ultra-compact packages. Building on its deep expertise in LED wafer fabrication, Cree developed these ultra-compact LEDs to have no compromises in color quality or efficacy compared to their conventional counterparts. Despite their very small size, the LEDs will also be robustly electrically integrated into luminaire systems with the same attach yield as conventional packages. The versatility of the prototype high-efficacy LED architecture will likely benefit solid-state lighting (SSL) luminaire platforms ranging from bulbs to troffers. We anticipate that the prototype LEDs will particularly benefit luminaires with large numbers of distributed compact packages, such as linear and area luminaires (e.g. troffers). The fraction of total SSL luminaire cost made up by the LEDs themselves has steadily fallen over the past several years, but can still make up 30% or more of the bill of materials; the new LED design will radically lower this proportion. Ultra-compact, highly efficient LEDs with optimal distribution in the system will further benefit luminaire materials and assembly costs by reducing the complexity and volume of thermal management and optical subsystems.

42 ENGINEERING↗

CALiPER Retail Lamps Study 3

The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other uses, such as in enclosed luminaires, may require more development. At the same price point, lamps purchased in 2013 tended to have higher output and slightly higher efficacy than in 2011 or 2010. Over 30% of the products purchased in 2013 exceeded the maximum efficacy measured in 2011 (71 lm/W), with the most efficacious product measured at 105 lm/W. There appears to be increasing consistency in color quality, with a vast majority of products having a CCT of 2700 K or 3000 K and a CRI between 80 and 85. There were also fewer poor performing products tested and more high-performing products available in 2013 than in previous years. The accuracy of equivalency and performance claims was better than in 2011, but remains a concern, with 43% of tested products failing to completely meet their equivalency claim and 20% of products failing to match the manufacturer’s performance data. Although progress has been substantial, on average LED lamps remain more expensive than other energy efficiency lighting technologies -- although some aspects can be superior. Although not universal to all product lines or all product types, the issue of insufficient lumen output from LED lamps is waning. Thus, manufacturers can focus on other issues, such as reducing cost, improving electrical/dimmer compatibility, eliminating flicker, or improving color quality. While these issues are not inherent to all products, they remain a concern for the broader market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chroma Shift and Gamut Shape: Going Beyond Average Color Fidelity and Gamut Area

Though sometimes referred to as a two-measure system for evaluating color rendition, IES TM-30-15 includes other key components that go beyond the high-level average values IES Rf and IES Rg. This article focuses on the Color Vector Graphic and Local Chroma Shift (IES Rcs,hj), discussing the calculation methods for these evaluation tools and providing context for the interpretation of the values. It also presents alternatives for quantifying the same characteristics, which can inform the development of future measures. The Color Vector Graphic (CVG) is a visual representation of hue and chroma shifts across different hues. It quickly communicates complex information about how object colors will be rendered by a light source, although it is difficult or impossible to use for writing a specification. CVGs demonstrate that increases in chroma for certain hues sometimes means a decrease in chroma for other hues, and illustrates hue shifts for intermediate colors. The combination of shifts over different hues can be referred to as gamut shape. Complementing this information are the IES Rcs,hj values, which quantify the average relative chroma shift for samples in each of the 16 hue-angle bins (j) specified in IES TM-30-15. Unlike measures of average color fidelity and gamut area, gamut shape and hue-specific chroma shift are new concepts with no directly-comparable historical references. It will be critical to incorporate the Color Vector Graphic and Local Chroma Shift values into practice because they capture information about color rendition that is impossible to describe with average measures (such as CIE Ra, IES Rf, or IES Rg), but that is critical to understanding human evaluations of color quality in architectural environments.

Chroma Shift↗

Human Perceptions of Colour Rendition at Different Chromaticities

An experiment was conducted to evaluate how subjective impressions of a light source’s color quality depend upon color rendition and chromaticity. Thirty-three participants each evaluated 50 lighting scenes in a 3.7 m by 5.5 m room filled with objects selected to cover a range of hue, saturation, and lightness. The lighting scenes included five chromaticity groups, specified here using correlated color temperature (CCT) and Duv¬: 2700 K, 0.000; 2700 K, -0.007; 3500 K, 0.000; 4300 K, 0.000; 4300 K, -0.007. Within each group were the same 10 systematically-varied color rendition conditions. The Illuminating Engineering Society (IES) TM-30-15 Fidelity Index (Rf) values ranged from 60 to 93, IES TM-30 Gamut Index (Rg) values from 88 to 124, and IES TM-30 Hue Angle Bin 1 Chroma Shift (Rcs,h1) values from -15% to 28%. All lighting scenes had the same nominal illuminance. Participants were asked to rate each scene on eight point scales for saturated-dull, normal-shifted, and like-dislike, as well as choosing whether they found the scenes to be acceptable or unacceptable. The findings suggest that color rendition preferences can vary with chromaticity, but do not support absolute preferences for negative Duv values. At 4300 K, there was no difference in rated preference, saturation, normalness, or acceptability between the two groups with different Duv values. However, at 2700 K, there was a significant difference for all four perceptions, with the negative Duv sources being rated more liked (on average)—and for nine of the ten individual color rendition conditions. Further, across all levels of red chroma shift—according to TM-30 values Rcs,h1, Rcs,h15, and Rcs,h16—the room was rated as more saturated at 2700 K than at 3500 K or 4300 K (regardless of Duv); in turn, increases in red saturation were less preferred and less acceptable at 2700 K than the other CCTs. The differences in ratings between the chromaticity groups were substantially smaller than the range in ratings for the 10 color rendition conditions in each group, and on average the best fit model uses a combination of Rf, Rcs,h16, and potentially Rg. Despite the differences in ratings for chromaticity groups, a set of criteria identified in previous research for preferred color rendition in this generic application could be used for all groups. Those criteria are Rf = 74, -1% = Rcs,h1 = 15%, and Rg = 100.

Royer, Michael P.↗

Cibachrome testing

The use of Cibachrome products as a solution to problems encountered when contact printing Kodak film type SO-397 onto Kodak Ektrachrome color reversal paper type 1993 is investigated. A roll of aerial imagery consisting of Kodak film types SO-397 and 2443 was contact printed onto Cibachrome and Kodak materials and compared in terms of color quality, resolution, cost, and compatibility with existing equipment and techniques. Objective measurements are given in terms of resolution and sensitometric response. Comparison prints and transparencies were viewed and ranked according to overall quality and aesthetic appeal. It is recommended that Cibachrome Print material be used in place of Kodak Ektachrome paper because it is more easily processed, the cost is equivalent, and it provides improved resolution, color quality, and image fade resistance.

Weinstein, M. S.↗

Spatial Brightness Perception of Trichromatic Stimuli

An experiment was conducted to examine the effect of tuning optical radiation on brightness perception for younger (18-25 years of age) and older (50 years of age or older) observers. Participants made forced-choice evaluations of the brightness of a full factorial of stimulus pairs selected from two groups of four metameric stimuli. The large-field stimuli were created by systematically varying either the red or the blue primary of an RGB LED mixture. The results indicate that light stimuli of equal illuminance and chromaticity do not appear equally bright to either younger or older subjects. The rank-order of brightness is not predicted by any current model of human vision or theory of brightness perception including Scotopic to Photopic or Cirtopic to Photopic ratio theory, prime color theory, correlated color temperature, V(λ)-based photometry, color quality metrics, linear brightness models, or color appearance models. Age may affect brightness perception when short-wavelength primaries are used, especially those with a peak wavelength shorter than 450 nm. The results suggest further development of metrics to predict brightness perception is warranted, and that including age as a variable in predictive models may be valuable.

Brightness perception↗

TM-30 Guidance

Minimum color quality standards are necessary, because the light sources most efficient at producing lumens are impractical for use in architectural lighting due to poor color rendition. Thus, accurate measures of color rendition and accompanying performance criteria are essential for helping technology developers and users balance tradeoffs between energy efficiency and lighting quality. Setting higher color-rendition criteria while maintaining use of CRI (e.g., CRI ≥ 90) may filter out some unacceptable light sources, but also filters out many highly desirable light sources and requires a greater tradeoff with energy efficiency. In contrast, specifying color rendition using TM-30 Rf, Rg, and Rcs,h1 has been shown to be effective for differentiating desirable sources while maintaining flexibility for technology development and energy efficiency.

Royer, Michael P.↗