Search NASA⌕ Search

SEARCH · Search NASA

Results for “color stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

LED Color Stability

DOE Solid-State Lighting program technology fact sheet that addresses key questions about color stability and color shift in LED lighting applications.

DOE, SSL, EERE, fact sheet, LED, color, stability,↗

Prognostication of LED Remaining Useful Life and Color Stability in the Presence of Contamination

The reliability of LED products may be affected by both luminous flux drop and color shift. Previous research on the topic focuses on either luminous maintenance or color shift. However, luminous flux degradation usually takes very long time to observe in LEDs under normal operating conditions. In this paper, the impact of a VOC (volatile organic compound) contaminated luminous flux and color stability are examined. As a result, both luminous degradation and color shift had been recorded in a short time. Test samples are white, phosphorconverted, high-power LED packages. Absolute radiant flux is measured with integrating sphere system to calculate the luminous flux. Luminous flux degradation and color shift distance were plotted versus aging time to show the degradation pattern. A prognostic health management (PHM) method based on the state variables and state estimator have been proposed in this paper. In this PHM framework, unscented kalman filter (UKF) was deployed as the carrier of all states. During the estimation process, third order dynamic transfer function was used to implement the PHM framework. Both of the luminous flux and color shift distance have been used as the state variable with the same PHM framework to exam the robustness of the method. Predicted remaining useful life is calculated at every measurement point to compare with the tested remaining useful life. The result shows that state estimator can be used as the method for the PHM of LED degradation with respect to both luminous flux and color shift distance. The prediction of remaining useful life of LED package, made by the states estimator and data driven approach, falls in the acceptable errorbounds (20%) after a short training of the estimator.

Lall, Pradeep↗

Highly efficient inverted top emitting organic light emitting diodes using a transparent top electrode with color stability on viewing angle

We report a highly efficient phosphorescent green inverted top emitting organic light emitting diode with excellent color stability by using the 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile/indium zinc oxide top electrode and bis(2-phenylpyridine)iridium(III) acetylacetonate as the emitter in an exciplex forming co-host system. The device shows a high external quantum efficiency of 23.4% at 1000 cd/m{sup 2} corresponding to a current efficiency of 110 cd/A, low efficiency roll-off with 21% at 10 000 cd/m{sup 2} and low turn on voltage of 2.4 V. Especially, the device showed very small color change with the variation of Δx = 0.02, Δy = 0.02 in the CIE 1931 coordinates as the viewing angle changes from 0° to 60°. The performance of the device is superior to that of the metal/metal cavity structured device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Full phosphorescent white-light organic light-emitting diodes with improved color stability and efficiency by fine tuning primary emission contributions

In this paper, a novel type of white-light organic light emitting diode (OLED) with high color stability was reported, in which the yellow-light emission layer of (4,4{sup ′}-N,N{sup ′}-dicarbazole)biphenyl (CBP) : tris(2-phenylquinoline-C2,N{sup ′})iridium(III) (Ir(2-phq){sub 3}) was sandwiched by double blue-light emission layers of 1,1-bis-[(di-4-tolylamino)pheny1]cyclohexane (TAPC) : bis[4,6-(di-fluorophenyl)-pyridinato-N,C2{sup ′}]picolinate (FIrpic) and tris[3-(3-pyridyl)mesityl]borane (3TPYMB):FIrpic. And, it exhibited the maximum current efficiency of 33.1 cd/A, the turn-on voltage at about 3 V and the maximum luminance in excess of 20000 cd/m{sup 2}. More important, it realized very stable white-light emission, and its CIE(x, y) coordinates only shift from (0.34, 0.37) to (0.33, 0.37) as applied voltage increased from 5 V to 12 V. It is believed that the new scheme in emission layer of white-light OLED can fine tune the contribution of primary emission with applied voltage changed, resulting in high quality white-light OLED.

36 MATERIALS SCIENCE↗

Using interlayer step-wise triplet transfer to achieve an efficient white organic light-emitting diode with high color-stability

An efficient phosphorescent white organic light emitting-diode with a red-green-blue tri-emitting-layer structure is reported. The host of the red dopant possesses a lower triplet-energy than the green dye. An interlayer step-wise triplet transfer via blue dye → green dye → red host → red dye is achieved. This mechanism allows an efficient triplet harvesting by the three dopants, thus maintaining a balanced white light and reducing energy loss. Moreover, the color stability of the device is improved significantly. The white device not only achieves a peak external quantum efficiency of 21.1 ± 0.8% and power efficiency of 37.5 ± 1.4 lm/W but shows no color shift over a wide range of voltages.

36 MATERIALS SCIENCE↗

Failure Mechanisms and Color Stability in Light-Emitting Diodes during Operation in High- Temperature Environments in Presence of Contamination

The energy efficiency of light-emitting diode (LED) technology compared to incandescent light bulbs has triggered an increased focus on solid state luminaries for a variety of lighting applications. Solid-state lighting (SSL) utilizes LEDs, for illumination through the process of electroluminescence instead of heating a wire filament as seen with traditional lighting. The fundamental differences in the construction of LED and the incandescent lamp results in different failure modes including lumen degradation, chromaticity shift and drift in the correlated color temperature. The use of LED-based products for safety-critical and harsh environment applications necessitates the characterization of the failure mechanisms and modes. In this paper, failure mechanisms and color stability has been studied for commercially available vertical structured thin film LED (VLED) under harsh environment conditions with and without the presence of contaminants. The VLED used for the study was mounted on a ceramic starboard in order to connect it to the current source. Contamination sources studied include operation in the vicinity of vulcanized rubber and adhesive epoxies in the presence of temperature and humidity. Performance of the VLEDs has been quantified using the measured luminous flux and color shift of the VLEDs subjected to both thermal and humidity stresses under a forward current bias of 350 mA. Results indicate that contamination can result in pre-mature luminous flux degradation and color shift in LEDs.

Lall, Pradeep↗

The effect of solvents on the stabilities (color and Fe) of anthocyanin isolated from the red-color-melinjo peels

Anthocyanin from the red-color-melinjo peels could be isolated using a polar solvent (ethanol) [ermiziar, 2010]. The amount of hydrocarbons in the structure of anthocyanin might cause that anthocyanin could be isolated using a non polar solvent. The purpose of research is to isolate anthocyanin using non polar solvents (hexane and petroleum ether) with maceration steps for 24 hours and separate solvents using rotary evaporator equipment. The stability of anthocyanin could be observed every week (1,2,3 and 4 weeks) in various environmental conditions (with or without light in refrigerator and open or closed storage). The characterization of anthocyanin was analyzed with visual (physic photo) and or using equipments such as Fourier Transform Infrared Spectroscopy (FTIR) for determining functional groups, Ultraviolet–Visible Spectroscopy (UV/Vis) with 500-550 nm wavelengths for deciding absorption of anthocyanin and atomic absorption spectroscopy (AAS) for analyzing Fe element. The result showed that anthocyanin isolation with hexane solvent has yield higher than petroleum eter solvent. From the results of physic observation for 4 weeks looked that there are changing colors of samples significant after 3 and 4 weeks in cooler with or without light. The stability of anthocyanin color was the best on the storage time until 2 weeks using hexane solvent in refrigerator and closed condition that it has absorption of 0.6740 with 500 nm wavelengths and Fe concentration 6.29 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient Blue Phosphorescent OLEDs with Improved Stability and Color Purity through Judicious Triplet Exciton Management

Abstract Highly efficient and stable blue phosphorescent organic light‐emitting diodes are achieved by employing a step‐wise graded doping of platinum(II) 9‐(pyridin‐2‐yl)‐2‐(9‐(pyridin‐2‐yl)‐9 H ‐carbazol‐2‐yloxy)‐9 H ‐carbazole (PtNON) in a device setting. A device employing PtNON demonstrates a high peak external quantum efficiency (EQE) of 17.4% with an estimated LT 70 lifetime of over 1330 h at a brightness of 1000 cd m −2 . PtNON is then investigated as a “triplet sensitizer” in an alternating donor–acceptor doped emissive layer to further improve the device emission color purity by carefully managing an efficient Förster resonant energy transfer from PtNON to 2,5,8,11‐tetra‐ tert ‐butylperylene as a selected acceptor material. Thus, such OLED devices demonstrate an EQE of 16.9% with color coordinates of (0.16, 0.25) and an estimated luminance (LT 70 ) lifetime of 628 h at a high brightness of 1000 cd m −2 .

Klimes, Kody↗

High performance flexible top-emitting warm-white organic light-emitting devices and chromaticity shift mechanism

Flexible warm-white top-emitting organic light-emitting devices (TEOLEDs) are fabricated onto PET substrates with a simple semi-transparent cathode Sm/Ag and two-color phosphors respectively doped into a single host material TCTA. By adjusting the relative position of the orange-red EML sandwiched between the blue emitting layers, the optimized device exhibits the highest power/current efficiency of 8.07 lm/W and near 13 cd/A, with a correlated color temperature (CCT) of 4105 K and a color rendering index (CRI) of 70. In addition, a moderate chromaticity variation of (-0.025, +0.008) around warm white illumination coordinates (0.45, 0.44) is obtained over a large luminance range of 1000 to 10000 cd/m{sup 2}. The emission mechanism is discussed via delta-doping method and single-carrier device, which is summarized that the carrier trapping, the exciton quenching, the mobility change and the recombination zone alteration are negative to color stability while the energy transfer process and the blue/red/blue sandwiched structure are contributed to the color stability in our flexible white TEOLEDs.

36 MATERIALS SCIENCE↗

Stabilizing shallow color centers in diamond created by nitrogen delta-doping using SF{sub 6} plasma treatment

Here we report the fabrication of stable, shallow (<5 nm) nitrogen-vacancy (NV) centers in diamond by nitrogen delta doping at the last stage of the chemical vapor deposition growth process. The NVs are stabilized after treating the diamond in SF{sub 6} plasma, otherwise the color centers are not observed, suggesting a strong influence from the surface. X-ray photoelectron spectroscopy measurements show the presence of only fluorine atoms on the surface, in contrast to previous studies, indicating very good surface coverage. We managed to detect hydrogen nuclear magnetic resonance signal from protons in the immersion oil, revealing a depth of the NVs of about 5 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A single-phase Ba{sub 9}Lu{sub 2}Si{sub 6}O{sub 24}:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} phosphor with tunable full-color emission for NUV-based white LED applications

Highlights: • A single phase Ba{sub 9}Lu{sub 2}Si{sub 6}O{sub 24}:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} phosphor with full-color emission was obtained by solid-state reactions. • Eu{sup 2+}, Ce{sup 3+}, and Mn{sup 2+} acts as blue, green, and red luminescence centers, respectively. • The BLS:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} phosphor shows a high quantum efficient of ∼62% and a good color stability. • Combining this single phosphor with a 395 nm NUV-chip, an ideal white LED with a high CRI of 85 and a CCT of 6300 K was obtained. - Abstract: We obtained a single phase BLS:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} phosphor by solid-state reactions. Eu{sup 2+}, Ce{sup 3+}, and Mn{sup 2+} gives rise to the blue, green, and red emission, respectively. The Mn{sup 2+} red emission can be effectively enhanced via energy transfers from both Eu{sup 2+} and Ce{sup 3+}. Thus a tunable full color emission from 410 to 750 nm was realized in this single phosphor. The Eu{sup 2+} → Mn{sup 2+} energy transfer mechanism was investigated by the fluorescence decay curves. This single phosphor exhibits an efficient excitation band covering from 390 to 410 nm, which matches well with the emission light of the efficient NUV chips. The optimized BLS:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} phosphor shows a high quantum efficient of ∼62% and a good color stability. When this single phosphor was combined with a 395 nm NUV-chip, an ideal white LED with a high color render index (CRI) of 85 and a correlated color temperature (CCT) of 6300 K was obtained. This demonstrates the promising application of the BLS:Eu{sup 2+}, Ce{sup 3+}, Mn{sup 2+} single phosphor for the NUV-based white LEDs.

36 MATERIALS SCIENCE↗

A comparison of temperature and humidity effects on phosphor-converted LED packages and the prediction of remaining useful life with state estimation

This paper focuses on the failure mechanisms and color stability of a commercially available high power LED under harsh environmental conditions. 3 groups of the same pc-HB warm white LED were used in the experiment. The first group was subjected to both high temperature and high relative humidity (85°C/85%RH) with a 350mA bias current. The second group was subjected to only temperature stress at 105°C with a 350mA bias current. The last group was subjected to extreme high temperature 175°C and high bias current (500mA). Samples were taken out from the chamber for both photometric and colorimetric analysis at periodic intervals to investigate the change of the optical parameters. The physics of failure due to the material degradation has been correlated with the change in the photometric and colorimetric parameters of the LED packages. At the end of the experiment, 6000 hours of data is projected forward with state estimation methods to compare with projections made with the TM-21 method. Experimental results shows that only optical parts degrades at high temperature conditions. However, at both high temperature and high relative humidity condition, the phosphor layer of the pc-LED can swell and the color stability of LEDs degrades significantly. Also, comparison between TM-21 method and state estimation method shows that state estimation can achieve the same goal with a relatively easy method.

Lall, Pradeep↗

Color Maintenance of LEDs in Laboratory and Field Applications

Synopsis: To date, consideration for parametric failure of LED products has largely been focused on lumen maintenance. However, color shift is a cause of early failure for some products, and is especially important to consider in certain applications, like museums, where visual appearance is critical. Example data collected by the GATEWAY program for LED lamps installed in museums shows that many have changed color beyond a reasonable tolerance well before their rated lifetime was reached, necessitating replacement. Similar data collected by the CALiPER program between 2008 and 2010 reveals that many early products shifted beyond acceptable tolerances in as little as a few thousand hours. In contrast, data from the L Prize program illustrates that commercially available LED products can have exemplary color stability that is unmatched by traditional light sources. Beyond presenting data from the aforementioned DOE programs, this report discusses the metrics used for communicating color shift—namely MacAdam ellipses and Δu'v'—as well as providing guidance for end users on how to monitor color shift and what to look for in manufacturer warranties. Also included are descriptions of the physical changes that have been documented as leading to color shift in some example types of LED packages. As with complete products, the data presented herein for LED packages shows that a wide variety of products are available; in order for specifiers and consumers to make educated choices, more detailed and standardized information should be made available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Color Maintenance of LEDs in Laboratory and Field Applications

To date, consideration for parametric failure of LED products has largely been focused on lumen maintenance. However, color shift is a cause of early failure for some products, and is especially important to consider in certain applications, such as museum lighting, where visual appearance is critical. Field data collected by the U.S. Department of Energy's (DOE) GATEWAY program for LED lamps installed in museums shows that many have changed color beyond a reasonable tolerance well before their rated lifetimes have been reached. Laboratory data collected by DOE's CALiPER program between 2008 and 2010 reveals that many early LED products shifted beyond acceptable tolerances in as little as a few thousand hours. In contrast, data from the L Prize® program illustrates that commercially available LED products can have exemplary color stability that is unmatched by traditional light sources. In addition to presenting data from the aforementioned DOE programs, this report discusses the metrics used for communicating color shift, and provides guidance for end users on how to monitor chromaticity and what to look for in manufacturer warranties. Also covered are the physical changes that have been shown to lead to color shift in some types of LED packages. As with lamps and luminaires, the data presented for LED packages shows that a wide variety of products are available; in order for specifiers and consumers to make educated choices, more detailed and standardized information is necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient, Color-Stable, and Long-Lived White Organic Light-Emitting Diodes Utilizing Phosphorescent Molecular Aggregates

Highly efficient and stable single-stack hybrid white organic light-emitting diode (WOLED) devices are developed using two emissive layers: one with amber-colored phosphorescent molecular-aggregate emission from the Pd(II) complex, Pd(II) 7-(3-(pyridine-2-yl-κN)phenoxy-κC)(benzo-κC)([c]benzo[4,5]imidazo-κN)[1,2-a][1,5]naphthyridine, Pd3O8-Py5, and the other with blue fluorescence emission. Here, an optimized device structure achieves high color stability under various current densities, an external quantum efficiency (EQE) of 45.5%, a power efficiency of 97.4 Lm W -1 , and an estimated LT 95 (operational time to 95% of the initial luminance) of 50 744 h at an initial luminance of 1000 cd m -2 .

36 MATERIALS SCIENCE↗

Prognostics Health Management Model for LED Package Failure Under Contaminated Environment

The reliability consideration of LED products includes both luminous flux drop and color shift. Previous research either talks about luminous maintenance or color shift, because luminous flux degradation usually takes very long time to observe. In this paper, the impact of a VOC (volatile organic compound) contaminated luminous flux and color stability are examined. As a result, both luminous degradation and color shift had been recorded in a short time. Test samples are white, phosphor-converted, high-power LED packages. Absolute radiant flux is measured with integrating sphere system to calculate the luminous flux. Luminous flux degradation and color shift distance were plotted versus aging time to show the degradation pattern. A prognostic health management (PHM) method based on the state variables and state estimator have been proposed in this paper. In this PHM framework, unscented kalman filter (UKF) was deployed as the carrier of all states. During the estimation process, third order dynamic transfer function was used to implement the PHM framework. Both of the luminous flux and color shift distance have been used as the state variable with the same PHM framework to exam the robustness of the method. Predicted remaining useful life is calculated at every measurement point to compare with the tested remaining useful life. The result shows that state estimator can be used as the method for the PHM of LED degradation with respect to both luminous flux and color shift distance. The prediction of remaining useful life of LED package, made by the states estimator and data driven approach, falls in the acceptable error-bounds (20%) after a short training of the estimator.

Lall, Pradeep↗

The Influence of Phosphor and Binder Chemistry on the Aging Characteristics of Remote Phosphor Products

The influence of phosphor and binder layer chemistries on the lumen maintenance and color stability of remote phosphor disks were examined using wet high-temperature operational lifetime testing (WHTOL). As part of the experimental matrix, two different correlated color temperature (CCT) values, 2700 K and 5000 K, were studied and each had a different binder chemistry. The 2700 K samples used a urethane binder whereas the 5000 K samples used an acrylate binder. Experimental conditions were chosen to enable study of the binder and phosphor chemistries and to minimize photo-oxidation of the polycarbonate substrate. Under the more severe WHTOL conditions of 85°C and 85% relative humidity (RH), absorption in the binder layer significantly reduced luminous flux and produced a blue color shift. The milder WHTOL conditions of 75°C and 75% RH, resulted in chemical changes in the binder layer that may alter its index of refraction. As a result, lumen maintenance remained high, but a slight yellow shift was found. The aging of remote phosphor products provides insights into the impact of materials on the performance of phosphors in an LED lighting system.

Davis, Lynn↗

SU-E-T-675: Remote Dosimetry with a Novel PRESAGE Formulation

Purpose: 3D-gel dosimetry provides high-resolution treatment validation; however, scanners aren’t widely available. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote site for irradiation, then shipped back for scanning and analysis, affording a convenient service for treatment validation to institutions lacking the necessary equipment and resources. Previous works demonstrated the high-resolution performance and temporal stability of PRESAGE. Here the newest formulation is investigated for remote dosimetry use. Methods: A new formulation of PRESAGE was created with the aim of improved color stability post irradiation. Dose sensitivity was determined by irradiating cuvettes on a Varian Linac (6MV) from 0–15Gy and measuring change in optical density at 633nm. Sensitivity readings were tracked over time in a temperature control study to determine long-term stability. A large volume study was performed to evaluate the accuracy for remote dosimetry. A 1kg dosimeter was pre-scanned, irradiated on-site with an 8Gy 4field box treatment, post-scanned and shipped to Princess Margaret Hospital for remote reading on an identical scanner. Results: Dose sensitivities ranged from 0.0194–0.0295 ΔOD/(Gy*cm)—similar to previous formulations. Post-irradiated cuvettes stored at 10°C retained 100% initial sensitivity over 5 days and 98.6% over 10 weeks while cuvettes stored at room temperature fell to 95.8% after 5 days and 37.4% after 10 weeks. The immediate and 5-day scans of the 4field box dosimeter data was reconstructed, registered to the corresponding eclipse dose-distribution, and compared with analytical tools in CERR. Immediate and 5-day scans looked visually similar. Line profiles revealed close agreement aside from a slight elevation in dose at the edge in the 5-day readout. Conclusion: The remote dosimetry formulation exhibits excellent temporal stability in small volumes. While immediate and 5-day readout scans of large volume dosimeters show promising agreement, further development is required to reduce an apparent time dependent edge elevation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗