Search NASA⌕ Search

SEARCH · Search NASA

Results for “color vision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

It's Time for Color Vision Deficiency Friendly Color Maps in the Radar Community

Color Vision Deficiency (CVD) is a decreased ability to discern between particular colors. 8% of men and 0.4% of women have some form of CVD. An informal poll of AGU and AMS twitter followers yielded 10% of 70 respondents self identifying as having CVD. When presenting data on a two-dimensional plane it is common to use colors to represent values, the mapping between values and colors is known as a colormap. Colormap choice is personal and is influenced by: (1) Ability to highlight scientifically interesting data. (2) Institutional choices (supervisor insists on a certain colormap). (3) Domain dominance of a particular colormap (common in the radar community). Colormap choice should be influenced by: (1) Ability to highlight scientifically interesting data. (2) Perceptual uniformity (thus not creating artificial structure). (3) Approachability by those with visual impairments (CVD). (4) Ideally, but not always achievable, reproducibility in greyscale.

Colormap↗

Effective Visualization of Radar Data for Users Impacted by Color Vision Deficiency

Color vision deficiency (CVD) is a decreased ability to discern between particular colors. Eight percent of genetic males and half a percent of genetic females have some form of CVD, with many in the radar community falling into this group. When presenting data on a two-dimensional plane, it is common to use colors to represent values via a colormap. Colormap choice in the radar community is influenced by the ability to highlight scientifically interesting features in data, institutional choices, and domain dominance of legacy colormaps. The problem with these current colormaps is that many do not project well for those with CVD (i.e., green next to red). In working with the CVD community to address this problem, multiple colormaps for moments such as equivalent reflectivity factor and Doppler velocity were created for users with forms of CVD such as deuteranomaly, protanomaly, protanopia, and deuteranopia using Python tools such as colorspacious and viscm. We show how these colormaps can improve interpretability for four cases: a mesoscale convective system, a pyrocumulonimbus storm, a wintertime midlatitude cyclone, and widespread storms with a large bird migration. These new radar equivalent reflectivity factor, Doppler velocity, and polarization colormaps are designed to highlight rain, frozen precipitation, nonmeteorological targets, and velocity-based items, are perceptually uniform, and are visually friendly for those with CVD.

54 ENVIRONMENTAL SCIENCES↗

Effective Visualization of Radar Data for Users Impacted By Color Vision Deficiency

Color Vision Deficiency (CVD) is a decreased ability to discern between particular colors. Eight percent of genetic males and half a percent of genetic females have some form of CVD, with many in the radar community falling into this group. When presenting data on a two-dimensional plane, it is common to use colors to represent values via a colormap. Colormap choice in the radar community is influenced by the ability to highlight scientifically interesting features in data, institutional choices, and domain dominance of legacy colormaps. The problem with these current colormaps is that many do not project well for those with CVD (i.e., green next to red). In working with the CVD community to address this problem, multiple colormaps for moments such as equivalent reflectivity factor and Doppler velocity were created for users with forms of CVD such as deuteranomaly, protanomaly, protanopia, and deuteranopia using Python tools such as colorspacious and viscm. We show how these colormaps can improve interpretability for four cases: a mesoscale convective system, a pyrocumulonimbus storm, a wintertime mid-latitude cyclone, and widespread storms with a large bird migration. These new radar equivalent reflectivity factor, Doppler velocity, and polarization colormaps are designed to highlight rain, frozen precipitation, non-meteorological targets, velocity-based items, be perceptually uniform, and visually friendly for those with CVD.

Zachary Sherman↗

Effect of elimination of nitrogen and/or hypoxia or restricted visual environment on color vision and range of accommodation

The effects upon range of accommodation and color vision of reduced atmospheric pressure, at partial and complete elimination of nitrogen, of hypoxia, and of exposure for varying periods of time to restricted visual environment, have been studied alone or in various combinations. Measurements were made on the electroretinogram, the electrooculogram, and the diameter of the retinal vessels as an indicator of blood flow to the retina at the time of total elimination of nitrogen. An objective method was used to test range of accommodation. In the color vision test the flicker colors of a Benham's top were matched with a colorimeter.

Wolbarsht, M. L.↗

Theoretical aspects of color vision

The three color receptors of Young-Helmholtz and the opponent colors type of information processing postulated by Hering are both present in the human visual system. This mixture accounts for both the phenomena of color matching or hue discrimination and such perceptual qualities of color as the division of the spectrum into color bands. The functioning of the cells in the visual system, especially within the retina, and the relation of this function to color perception are discussed.

Wolbarsht, M. L.↗

Analysis of the retinex theory of color vision

Land's (1983) retinex algorithm is a model of human color constancy. The retinex algorithm is analyzed and its general properties are discussed. It is shown that the algorithm is too sensitive to changes in the color of nearby objects to serve as an adequate model of human color constancy.

Brainard, D. H.↗

Relating Standardized Visual Perception Measures to Simulator Visual System Performance

Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

Kaiser, Mary K.↗

A color-coded vision scheme for robotics

Most vision systems for robotic applications rely entirely on the extraction of information from gray-level images. Humans, however, regularly depend on color to discriminate between objects. Therefore, the inclusion of color in a robot vision system seems a natural extension of the existing gray-level capabilities. A method for robot object recognition using a color-coding classification scheme is discussed. The scheme is based on an algebraic system in which a two-dimensional color image is represented as a polynomial of two variables. The system is then used to find the color contour of objects. In a controlled environment, such as that of the in-orbit space station, a particular class of objects can thus be quickly recognized by its color.

Johnson, Kelley Tina↗

Ocular Outcomes Comparison Between 14- and 70-day Head-down Tilt Bed Rest

INTRODUCTION: Ophthalmological changes, including optic disc edema with optic nerve sheath distension, posterior globe flattening with hyperopic shift, choroidal folds and cotton wool spots have been detected in some astronauts involved in long-duration spaceflights. (sup 1) It is hypothesized that elevated intracranial pressure resulting from microgravity-induced cephalad fluid shifts may be responsible for most of these findings. Head-down tilt bed rest (HTDBR) is a ground-based microgravity analog which also produces cephalad fluid shifts. It is conceivable that prolonged HDTBR exposure may induce ocular changes similar to those experienced in microgravity. Therefore, the purpose of the present study was to compare structural and functional ocular outcomes between 14- and 70-day HDTBR in healthy human subjects. It is hypothesized that 70-d HDTBR induced ocular changes of greater magnitude as compared to 14-d HDTBR. METHODS: Two HDTBR studies were conducted at the NASA Flight Analogs Research Unit, located at The University of Texas Medical Branch at Galveston, TX. Identical NASA standard screening procedures and BR conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants spent 14 and/or 70 consecutive days in a 6deg HDT position and did not engage in exercise. Subjects received weekly ocular examinations before, during, and after HDTBR. Ocular testing included: distance and near best-corrected visual acuity (BCVA), cycloplegic refraction, intraocular pressure (IOP) measurement, color vision, red dot test, modified Amsler grid test, confrontational visual field, color fundus photography and Spectral-domain OCT scans of the macula and the optic disc. Pre/post HDTBR differences between the two studies will be evaluated for BCVA, spherical equivalent, IOP, retinal nerve fiber layer (RNFL) thickness and macular OCT parameters. RESULTS: 16 (12 males and 4 females) and 6 (5 males and 1 female) subjects participated in the 14 and 70-day HDTBR studies, respectively. One subject participated in both studies. The demographic and ophthalmological characteristics of the 14-day HDTBR study have been presented elsewhere.2 In the 70- day study, subjects age averaged 39.5 +/- 7.8 years; pre- and post-HDTBR Goldmann IOP were, on average, 15.4 and 14.6 mmHg in the right eye, and 15.3 and 14.4 mmHg in the left eye, respectively; preand post-HDTBR Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) average RNFL thickness were 103.8 and 106 μm in the right eye, and 103 and 104.3 μm in the left eye, respectively. In both studies, color vision, red dot test, modified Amsler grid test and confrontational visual field were within normal limits at all time points; no changes were detected on stereoscopic color optic disc photography. For the above outcomes, preliminary results of the pre/post HDTBR differences between the two studies will be presented at the 2015 Human Research Program Investigators' Workshop. CONCLUSIONS: Although 14-day HDTBR did not seem to induce clinically relevant ocular changes, (sup 2) a systematic evaluation and comparison with the 70-day HDTBR study results will elucidate whether the magnitude of ocular structural and functional changes is affected by the time spent in the recumbent position. Further research will also address the effects of integrated resistance and aerobic training during HDTBR on the ocular outcomes. REFERENCES: 1. Mader TH et al. Optic disc edema, globe flattening, choroidal folds, and hyperopic shifts observed in astronauts after long-duration space flight. Ophthalmology. 2011;118(10):2058-69. 2. Taibbi G et al. Ocular outcomes evaluation in a 14-day head-down bed rest study. Aviat Space Environ Med. 2014;85(10):983-92.

Cromwell, R.L.↗

Comparison of Structural and Functional Ocular Outcomes Between 14- and 70 Day Bed Rest

Purpose: To compare structural and functional ocular outcomes in healthy human subjects undergoing 14- and/or 70-day head-down-tilt bed rest (HDTBR). We hypothesized the amount of HDTBR-induced ocular changes be affected by the HDTBR duration. Methods: The studies were conducted at the NASA Flight Analogs Research Unit, The University of Texas Medical Branch at Galveston, Galveston, TX. Participants were selected using NASA standard screening procedures. Standardized NASA screening procedures and bed rest conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants maintained a 6deg HDTBR position for 14 and/or 70 consecutive days and did not engage in exercise. Weekly ophthalmological examinations were conducted in the sitting (pre/post-bed rest only) and HDT positions. Ocular outcomes of interest included: near best-corrected visual acuity (BCVA); spherical equivalent, as determined by cycloplegic autorefraction; Goldmann applanation tonometry and iCare (Icare Finland Oy, Espoo, Finland) intraocular pressure (IOP) measurement; color vision; red dot test; modified Amsler grid test; confrontational visual field; stereoscopic color fundus photography; Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) retinal nerve fiber layer thickness (RNFLT), peripapillary and macular retinal thicknesses. Mixed-effects linear models were used to compare pre- and post-HDTBR observations between 14- and 70-day HDTBR for our continuously scaled outcomes.

Cromwell, R. L.↗

Color constancy and the natural image

Color vision is useful only if it is possible to identify an object's color across many viewing contexts. Here, consideration is given to recent results on how to estimate the surface reflectance function of an object from image data, despite (1) uncertainty in the spectral power distribution of the ambient lighting, and (2) uncertainty about what other surfaces will be in the field of view.

Wandall, Brian A.↗

On the importance of color in mass spectrometry imaging

Mass spectrometry imaging (MSI) data visualization relies on heatmaps to show the spatial distribution and measured abundances of molecules within a sample. Non-uniform color gradients such as jet are still commonly used to visualize MSI data, increasing the probability of data misinterpretation and false conclusions. Also, the use of non-uniform color gradients and the combination of hues used in common colormaps makes it challenging for people with color vision deficiencies (CVDs) to visualize and accurately interpret data. Here we present best practices for choosing a colormap to accurately display MSI data, improve readability, and accommodate all CVDs. We also provide other resources on the misuse of color in the scientific field and resources on scientifically derived colormaps presented herein.

47 OTHER INSTRUMENTATION↗

Running head: What color is it

Color vision provides low-resolution spectrophotometric information about candidate materials for planetary surfaces that is comparable in precision to wideband photoelectric photometry, and considerably superior to Voyager TV data. Briefly explained are the basic concepts, teminology, and notation of color science. Also shown is how to convert a reflectance spectrum into a color specification. An Appendix lists a simple computer subroutine to convert spectral reflectance into CIE coordinates, and the text explains how to convert these to a surface color in a standard color atlas. Target and printed Solar System colors are compared to show how accurate are the printed colors.

Young, Andrew T.↗