Ultrafast Electron Microscopy Module to Upgrade Existing Commercial Electron Microscopes
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Electronic parts used in Nuclear Security Enterprise (NSE) applications have varying pedigrees. Understanding the differences among these "part classes" will better enable Kansas City National Security Campus (KCNSC) and Sandia National Laboratories (SNL, or Sandia) to effectively manage factors such as risk, effort, cost, etc. across all functional areas which have a shared interest in the definition and acquisition process. Regardless of the pedigree and complexity, all parts are expected to meet necessary quality and reliability requirements. This activity has been conducted as part of the COTS Transformation Initiative (CTI).
Explore the source record for details and available documents.
A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.
The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.
The majority of radioisotopes used in the United States today come from foreign suppliers or are generated parasitically in large government accelerators and nuclear reactors. Both of these restrictions limit the availability of radioisotopes and discourage the development and evaluation of new isotopes and for nuclear medicine, science, and industry. Numerous studies have been recommending development of dedicated accelerators for production of radioisotopes for over 20 years (Institute of Medicine, 1995; Reba, et al, 2000; National Research Council, 2007; NSAC 2009). The 2015 NSAC Long Range Plan for Isotopes again identified electron accelerators as an area for continued research and development. Recommendation 1(c) from the 2015 NSAC Isotope report specifically identifies electron accelerators for continued funding for the purpose of producing medical and industrial radioisotopes. Recognizing the pressing need for new production methods of radioisotopes, the United States Congress passed the American Medical Isotope Production Act of 2012 to develop a domestic production of 99 Mo and to eliminate the use of highly enriched uranium (HEU) in the production of 99 Mo. One of the advantages of high power electron linear accelerators (linacs) is they can create both proton- and neutron-rich isotopes by generating high energy x-rays that knock out protons or neutrons from stable atoms or by fission of uranium. This allows for production of isotopes not possible in nuclear reactors. Recent advances in superconducting electron linacs have decreased the size and complexity of these systems such that they are economically competitive with nuclear reactors and large, high energy accelerators. Niowave, Inc. has been developing a radioisotope production facility based on a superconducting electron linac with liquid metal converters.
We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.
Explore the source record for details and available documents.
A method for achieving good position resolution of low-intensity electron signals using a microchannel plate resistive anode detector is demonstrated. Electron events at a rate of 7 counts s{sup −1} are detected using a Z-stack microchannel plate. The dependence of position resolution on both the distance and the potential difference between the microchannel plate and resistive anode is investigated. Using standard commercial electronics, a measured position resolution of 170 μm (FWHM) is obtained, which corresponds to an intrinsic resolution of 157 μm (FWHM)
Characterization of unintended radiated emissions (URE) from electronic devices plays an important role in many research areas from electromagnetic interference to nonintrusive load monitoring to information system security. URE can provide insights for applications ranging from load disaggregation and energy efficiency to condition-based maintenance of equipment-based upon detected fault conditions. URE characterization often requires subject matter expertise to tailor transforms and feature extractors for the specific electrical devices of interest. We present a novel approach, named dimensionally aligned signal projection (DASP), for projecting aligned signal characteristics that are inherent to the physical implementation of many commercial electronic devices. These projections minimize the need for an intimate understanding of the underlying physical circuitry and significantly reduce the number of features required for signal classification. We present three possible DASP algorithms that leverage frequency harmonics, modulation alignments, and frequency peak spacings, along with a two-dimensional image manipulation method for statistical feature extraction. To demonstrate the ability of DASP to generate relevant features from URE, we measured the conducted URE from 14 residential electronic devices using a 2 MS/s collection system. Furthermore, a linear discriminant analysis classifier was trained using DASP generated features and was blind tested resulting in a greater than 90% classification accuracy for each of the DASP algorithms and an accuracy of 99.1% when DASP features are used in combination. Furthermore, we show that a rank reduced feature set of the combined DASP algorithms provides a 98.9% classification accuracy with only three features and outperforms a set of spectral features in terms of general classification as well as applicability across a broad number of devices.
Optocouplers, also called optoisoloators and photocouplers, are devices that use a light emitting diode (LED) to conduct an electrical signal. The LED receives an electrical signal and emits light proportional to that signal. The light is then received by a photodetector and the signal is propagated. Optocouplers provide a high degree of electrical isolation and are therefore used extensively in commercial electronic equipment. Variations in optocouplers come from the type of photodetector used, the anatomy of the contents and the encapsulating polymers used. Current research involves investigating the tolerance of optocouplers to radiation for the purpose of improving spacecraft and satellites, as well as identifying failure mechanisms and improving design.
Optocouplers, also called optoisolators and photocouplers, are devices that use a light emitting diode (LED) to conduct an electrical signal. The LED receives an electrical signal and emits light proportional to that signal. The light is then received by a phototransistor and the signal is propagated. Optocouplers provide a high degree of electrical isolation and are therefore used extensively in commercial electronic equipment. Variations in optocouplers come from the type of photodetector used, the anatomy of the contents and the encapsulating polymers used. Current research involves investigating the tolerance of optocouplers to radiation for the purpose of improving spacecraft and satellites, as well as identifying failure mechanisms and improving design. My project involvement at LANL includes conducting thermal and mechanical tests on three different cure profiles of epoxy to collect data about shrinkage, coefficient of thermal expansion, and degree of cure for a group wanting to produce their own optocoupler.
Commercial light emitting diode (LED) materials - blue (i.e., InGaN/GaN multiple quantum wells (MQWs) for display and lighting), green (i.e., InGaN/GaN MQWs for display), and red (i.e., Al 0.05 Ga 0.45 In 0.5 P/Al 0.4 Ga 0.1 In 0.5 P for display) are evaluated in range of temperature (77–800) K for future applications in high density power electronic modules. The spontaneous emission quantum efficiency (QE) of blue, green, and red LED materials with different wavelengths was calculated using photoluminescence (PL) spectroscopy. The spontaneous emission QE was obtained based on a known model so-called the ABC model. This model has been recently used extensively to calculate the internal quantum efficiency and its droop in the III-nitride LED. At 800 K, the spontaneous emission quantum efficiencies are around 40% for blue for lighting and blue for display LED materials, and it is about 44.5% for green for display LED materials. The spontaneous emission QE is approximately 30% for red for display LED material at 800 K. The advance reported in this paper evidences the possibility of improving high temperature optocouplers with an operating temperature of 500 K and above.
Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.
Modern electron microscopy analysis can provide detailed insight into the microstructure and chemistry of high burnup UO{sub 2} fuel. This more complete understanding of fuel evolution and performance in reactor can provide critical insight necessary to validate fuel performance models and optimize reactor operations. Preliminary results from the investigation of a polished cross-section of high burnup UO{sub 2} fuel (seven cycles) from the H.B. Robinson pressurized water reactor will be discussed. The analysis focuses on scanning electron microscopy (SEM) of the complete cross-section, while scanning transmission electron microscopy (S/TEM) was performed on targeted features identified by SEM where specimens were fabricated by traditional focused ion beam lift-out techniques. Analysis of the complete cross-section allowed for investigation of the microstructural variations from centerline to fuel/clad interface, pellet/pellet interface, and cladding. Secondary electron imaging and backscatter electron imaging was performed to identify variations in the distribution of fission product secondary phases and bubbles/voids. The analysis of the pellet/pellet interface is a unique feature of this sample where initial analysis shows segregation of fission product phases at the pellet/pellet interface and also indicates an interface microstructure lacking of bubbles and voids. X-ray spectrum imaging was performed by both SEM and STEM techniques to identify the composition of the secondary phases present in the fuel. Multivariate statistical analysis (MVSA) of the X-ray spectrum images has been applied to improve the sensitivity of the analysis and highlight minor variations in the fuel chemistry and secondary phases comprised of fission product as well as the distribution of sub-surface Xe gas bubbles in the high burnup structure. The results presented demonstrate the level of microstructural understanding that is attainable with a combination of SEM techniques along with S/TEM techniques.
Commercial-Off-The-Shelf (COTS) electronics offer cutting-edge capability at lower prices compared to their space-grade counterparts. However, their use in space missions has been limited due to concerns around survivability in a space environment; COTS devices are not designed to survive the harsh radiation environment of space. Nonetheless, for space missions with short durations it may be possible to use COTS electronics. This study evaluates the use of several families of COTS electronics for a specific short-term mission. An assembled database including selected space grade and COTS components is discussed. High confidence FPGAs, microprocessors, and optocouplers COTS are identified. Medium confidence Memory, ADCs, DACs, power electronics, and RFMMICs COTS are also included, as well as testing to improve confidence in medium confidence parts. An experimental approach for evaluating tin whisker susceptibility for tin-leaded COTS components is described. Using COTS electronics in Short-Term Geostationary Satellites is feasible; this report includes enabling tools.
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.