Search NASA⌕ Search

SEARCH · Search NASA

Results for “commercial field study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Mapping Environmental Contaminants at Ray Mine, AZ

Airborne Visible and InfraRed Imaging Spectrometer (AVIRIS) data was collected over Ray Mine as part of a demonstration project for the Environmental Protection Agency (EPA) through the Advanced Measurement Initiative (AMI). The overall goal of AMI is to accelerate adoption and application of advanced measurement technologies for cost effective environmental monitoring. The site was selected to demonstrate the benefit to EPA in using advanced remote sensing technologies for the detection of environmental contaminants due to the mineral extraction industry. The role of the Jet Propulsion Laboratory in this pilot study is to provide data as well as performing calibration, data analysis, and validation of the AVIRIS results. EPA is also interested in developing protocols that use commercial software to perform such work on other high priority EPA sites. Reflectance retrieval was performed using outputs generated by the MODTRAN radiative transfer model and field spectra collected for the purpose of calibration. We are presenting advanced applications of the ENVI software package using n-Dimensional Partial Unmixing to identify image-derived endmembers that best match target materials reference spectra from multiple spectral libraries. Upon identification of the image endmembers the Mixture Tuned Match Filter algorithm was applied to map the endmembers within each scene. Using this technique it was possible to map four different mineral classes that are associated with mine generated acid waste.

McCubbin, Ian↗

Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass

Frequently there is an inability to process and analyze samples of low biomass due to limiting amounts of relevant biomaterial in the sample. Furthermore, molecular biological protocols geared towards increasing the density of recovered cells and biomolecules of interest, by their very nature, also concentrate unwanted inhibitory humic acids and other particulates that have an adversarial effect on downstream analysis. A novel and robust fluorescence-activated cell-sorting (FACS)-based technology has been developed for purifying (removing cells from sampling matrices), separating (based on size, density, morphology), and concentrating cells (spores, prokaryotic, eukaryotic) from a sample low in biomass. The technology capitalizes on fluorescent cell-sorting technologies to purify and concentrate bacterial cells from a low-biomass, high-volume sample. Over the past decade, cell-sorting detection systems have undergone enhancements and increased sensitivity, making bacterial cell sorting a feasible concept. Although there are many unknown limitations with regard to the applicability of this technology to environmental samples (smaller cells, few cells, mixed populations), dogmatic principles support the theoretical effectiveness of this technique upon thorough testing and proper optimization. Furthermore, the pilot study from which this report is based proved effective and demonstrated this technology capable of sorting and concentrating bacterial endospore and bacterial cells of varying size and morphology. Two commercial off-the-shelf bacterial counting kits were used to optimize a bacterial stain/dye FACS protocol. A LIVE/DEAD BacLight Viability and Counting Kit was used to distinguish between the live and dead cells. A Bacterial Counting Kit comprising SYTO BC (mixture of SYTO dyes) was employed as a broad-spectrum bacterial counting agent. Optimization using epifluorescence microscopy was performed with these two dye/stains. This refined protocol was further validated using varying ratios and mixtures of cells to ensure homogenous staining compared to that of individual cells, and were utilized for flow analyzer and FACS labeling. This technology focuses on the purification and concentration of cells from low-biomass spacecraft assembly facility samples. Currently, purification and concentration of low-biomass samples plague planetary protection downstream analyses. Having a capability to use flow cytometry to concentrate cells out of low-biomass, high-volume spacecraft/ facility sample extracts will be of extreme benefit to the fields of planetary protection and astrobiology. Successful research and development of this novel methodology will significantly increase the knowledge base for designing more effective cleaning protocols, and ultimately lead to a more empirical and true account of the microbial diversity present on spacecraft surfaces. Refined cleaning and an enhanced ability to resolve microbial diversity may decrease the overall cost of spacecraft assembly and/or provide a means to begin to assess challenging planetary protection missions.

Benardini, James N.↗