Search NASA⌕ Search

SEARCH · Search NASA

Results for “commercial-off-the-shelf”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Environmental Chamber Testing and Headspace Evaluation of a Commercial-Off-The-Shelf Foam Fixative to Support Deactivation and Decommissioning Activities

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with identifying high priority technical needs and the Technology Development (TD) tasks required to meet those needs in support of ongoing deactivation and decommissioning (D&D) of Department of Energy infrastructure across the United States. This work consists of placing a radioactively contaminated facility in stable condition to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning will leave the buildings in an agreed upon end state to provide future protection against a wide range of hazards that include radiation, asbestos, polychlorinated biphenyls, and other environmental and public health risks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Super-Resolution Approaches in Three-Dimensions for Classification and Screening of Commercial-Off-The-Shelf Components

X-ray computed tomography is generally a primary step in characterization of defective electronic components, but is generally too slow to screen large lots of components. Super-resolution imaging approaches, in which higher-resolution data is inferred from lower-resolution images, have the potential to substantially reduce collection times for data volumes accessible via x-ray computed tomography. Here we seek to advance existing two-dimensional super-resolution approaches directly to three-dimensional computed tomography data. Multiple scan resolutions over a half order of magnitude of resolution were collected for four classes of commercial electronic components to serve as training data for a deep-learning, super-resolution network. A modular python framework for three-dimensional super-resolution of computed tomography data has been developed and trained over multiple classes of electronic components. Initial training and testing demonstrate the vast promise for these approaches, which have the potential for more than an order of magnitude reduction in collection time for electronic component screening.

47 OTHER INSTRUMENTATION↗

CROWBAR: Natively Fuzzing Trusted Applications Using ARM CoreSight

Abstract Trusted execution environments (TEE) are deployed on many platforms to provide both confidentiality and integrity, and their extensive use offers a secure environment for privacy-sensitive operations. Despite TEE prevalence in the smartphone and tablet market, vulnerability research into TEE security is relatively rare. This is, in part, due to the strong isolation guarantees provided by its implementation. In this paper, we propose a hardware assisted fuzzing framework, CROWBAR, that bypasses TEE isolation to natively evaluate trusted applications (TAs) on mobile devices by leveraging ARM CoreSight components. CROWBAR performs feedback-driven fuzzing on commercial, closed source TAs while running in a TEE protected environment. We implement CROWBAR on 2 prototype commercial-off-the-shelf (COTS) smartphones and one development board, finding 3 unique crashes in 5 closed source TAs that are previously unreported in the TrustZone fuzzing literature.

Shan, Haoqi↗

Ultra-low radioactivity Kapton and copper-Kapton laminates

Polyimide-based materials, like Kapton, are widely used in flexible cables and circuitry due to their unique electrical and mechanical characteristics. This study is aimed at investigating the radiopurity of Kapton for use in ultralow background, rare-event physics applications by measuring the 238U, 232Th, and natK levels using inductively coupled plasma mass spectrometry. Commercial-off-the-shelf Kapton varieties, mea- sured at approximately 950 and 120 pg/g 238U and 232Th (1.2×104 and 490 µBq/kg), respectively, can be a significant background source for many current and next-generation ultralow background detectors. This study has found that the dominant contamination is due to the use of dicalcium phosphate (DCP), a nonessential slip additive added during manufacturing. Alternative Kapton materials were obtained that did not contain DCP and were determined to be significantly more radiopure than the commercially- available options with 12 and 19 pg/g 238U and 232Th (150 and 77 µBq/kg), respectively. The lowest radioactivity version produced (Kapton ELJ, which contains an adhesive) was found to contain single digit pg/g levels of 238U and 232Th, two-to-three orders of magnitude cleaner than commercial-off-the- shelf options. Moreover, copper-clad polyimide laminates employing Kapton ELJ as the insulator were obtained and measured and showed to be very radiopure at 8.6 and 22 pg/g 238U and 232Th (110 and 89 µBq/kg), respectively.

Arnquist, Isaac J.↗

Uranium corrosion characterization by handheld laser-induced breakdown spectroscopy

In this study, a commercial-off-the-shelf handheld laser-induced breakdown spectroscopy system was modified, calibrated and tested for discrimination between uranium oxide and uranium hydride when assessing uranium corrosion products. Operating parameters, system modifications, and onboard data analysis were developed to accomplish the analytical task. This work represents the first laser-induced breakdown spectroscopy analysis of bulk uranium hydride, a pyrophoric material, within an inert glovebox. Finally, the work shown here illustrates a rapid identification technique for uranium corrosion types from pure UO 2 or U 3 O 8 to pure UH 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

Computational Modeling of a 3D Printed Recuperator and Subsequent Experimental Loop for Supercritical Carbon Dioxide Cycles

Oak Ridge National Laboratory (ORNL), in collaboration with mechanical-thermal energy storage (mTES) provider EarthEn, a US Department of Energy (DOE) Lab-Embedded Entrepreneurship Program (LEEP) recipient at ORNL’s Innovation Crossroads 2023, is utilizing a state-of-the-art patented 3D printing technique to design an additively manufactured (AM) supercritical CO2 (sCO2) recuperator (REC) for EarthEn’s charge/discharge cycle. The AM REC will be printed at ORNL’s Manufacturing Demonstration Facility using Inconel Alloy 718 and tested on a closed-loop, ∼100 kW scale experimental facility that is under construction. The testing will compare the printed design against a commercial-off-the-shelf Printed Circuit Heat Exchanger (PCHE) REC. The design of the sCO2 facility is guided by a Modelica-based system model which is primarily dependent on the open-source TRANSFORM library developed at ORNL and uses the open-source CoolProp library for thermophysical properties of sCO2 via the External Media library. It is envisioned that an iterative process will be followed between the physical loop and the system model wherein the initial experimental data will be used to tune the model, which in turn will be used to guide future loop operation. Simultaneously, the AM REC is being designed using computer-aided design models, and it is also being analyzed for hydraulic and thermomechanical response using commercial computational fluid dynamics software, Simcenter STAR-CCM+, on highperformance computing resources.1

See, Nate [ORNL] (ORCID:0000000178581202)↗

Reconfigurable Framework for Resilient Semantic Segmentation for Space Applications

Deep learning (DL) presents new opportunities for enabling spacecraft autonomy, onboard analysis, and intelligent applications for space missions. However, DL applications are computationally intensive and often infeasible to deploy on radiation-hardened (rad-hard) processors, which traditionally harness a fraction of the computational capability of their commercial-off-the-shelf counterparts. Commercial FPGAs and system-on-chips present numerous architectural advantages and provide the computation capabilities to enable onboard DL applications; however, these devices are highly susceptible to radiation-induced single-event effects (SEEs) that can degrade the dependability of DL applications. In this article, we propose Reconfigurable ConvNet (RECON), a reconfigurable acceleration framework for dependable, high-performance semantic segmentation for space applications. In RECON, we propose both selective and adaptive approaches to enable efficient SEE mitigation. In our selective approach, control-flow parts are selectively protected by triple-modular redundancy to minimize SEE-induced hangs, and in our adaptive approach, partial reconfiguration is used to adapt the mitigation of dataflow parts in response to a dynamic radiation environment. Combined, both approaches enable RECON to maximize system performability subject to mission availability constraints. We perform fault injection and neutron irradiation to observe the susceptibility of RECON and use dependability modeling to evaluate RECON in various orbital case studies to demonstrate a 1.5–3.0× performability improvement in both performance and energy efficiency compared to static approaches.

97 MATHEMATICS AND COMPUTING↗

TCAD-Machine Learning Enabled TID Compact Model Development for Commercial SiC MOSFET

We propose a TCAD (Technology Computer Aided Design)-machine learning coupled approach that combines a TCAD tool (Charon), optimization/uncertainty quantification tool (Dakota), surrogate models, and Bayesian learning capabilities. The coupling approach is used for accurate modeling and calibration of total ionizing dose (TID) induced threshold voltage (V th ) shifts in Commercial-Off-The-Shelf (COTS) semiconductor devices and to develop physics-informed TID compact models. This versatile approach is applied to model the TID effect in an exemplar COTS 3.3 kV SiC power MOSFET (Metal-Oxide-Semiconductor Field-Effect Transistor). With the Charon-Dakota coupling, we can determine key device geometry and doping values based on device physics, which are difficult to obtain or not available for COTS devices but important for TCAD simulation; additionally, we can efficiently generate thousands of simulation results in a large parameter space, which makes it possible to develop data-driven surrogate models and perform Bayesian calibration. Utilizing the full tool-coupling approach, we achieve calibrated TCAD simulation models that accurately capture the average TID-induced V th shifts behavior with total doses and V th shifts saturation at high doses as observed in experimental data. More importantly, the calibrated TCAD simulations are obtained with determined TID model parameters (e.g., hole trap density and capture cross section) values that contain well quantified uncertainties. Furthermore, we can isolate and quantify the noises that are not captured by the TCAD models but exist in the measured data due to measurements and devices variabilities. Lastly, the calibrated surrogate models are used to develop physics-informed TID compact models. The method is generalizable to other devices and/or radiation conditions with few modifications and can provide well-determined uncertainties.

COTS↗

Robust COTS objective for diffraction-limited, high-NA, long front working distance imaging

We present a robust objective lens optimized for applications requiring both high numerical aperture (NA) and long front working distance imaging, comprised of all commercial-off-the-shelf (COTS) spherical singlet lenses. Unlike traditional designs that require separate collimation and refocusing stages, our approach directly converges imaged light to the back focal plane using a single lens group. Our configuration corrects spherical aberrations and efficiently collects light to achieve diffraction-limited performance across a wide range of wavelengths while simplifying alignment and assembly. Using this approach, we design and construct an example objective lens that features a long front working distance of 61 mm and a clipped NA of 0.30 (limited by an aperture in our experimental setup). We experimentally verify that it achieves monochromatic diffraction-limited resolution at wavelengths from 375 nm to 866 nm without requiring replacement of the lenses or changing the inter-lens spacings, and its performance remains robust across a 46 mm range variation in total length (by adjusting mainly the back working distance). Additionally, we develop a quantitative method to measure the field of view (FOV) using an experimentally calibrated pinhole target. Under 397 nm illumination (i.e., from 40 Ca + ion fluorescence), the objective achieves a resolution of 0.87 μm with a 540 μm FOV. This robust, all-COTS, and versatile design is well-suited for a broad range of experiments, supporting high-precision measurements and exploring quantum phenomena.

Cui, Jiafeng [Oak Ridge National Laboratory (ORNL)↗

Triton Field Trials (TFiT) underwater noise - University of New Hampshire Living Bridge turbine Processed Data

In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire's Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory's Triton Field Trials (TFiT) described in a paper published in a Special Issue of Journal of Marine Energy Science and Engineering, this study provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites. The paper can be accessed in the link bellow.

16 TIDAL AND WAVE POWER↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

A novel approach to mitigating the potential release of radioisotopes under fire conditions - enhancing fire resiliency of radiological contamination fixatives during deactivation & decommissioning activities

Savannah River National Laboratory (SRNL), in close collaboration with the Florida International University Applied Research Center (FIU ARC), successfully executed a technology development activity on behalf of the Department of Energy, Office of Environmental Management (DOE EM). The purpose of the activity was to improve the capability of fixative technologies in immobilizing residual contamination when exposed to thermal stressors as postulated in accident scenarios in Basis for Interim Operations (BIO) documents across the DOE EM complex. The effort resulted in the test and evaluation of a down-selected, commercial-off-the-shelf (COTS) intumescent technology in a radioactive environment at the Savannah River Site (SRS) Building 235-F Plutonium Fuel Form (PuFF) Facility and highlighted the potential use of this technology as a stand-alone, fire retardant fixative. Furthermore, this activity highlighted significant shortfalls in common fixatives currently used to support decommissioning activities and brought to the forefront the need for a methodical, uniformed approach to certifying fixative technologies for operational use in Deactivation and Decommissioning (D&D) activities. An essential component of this research was to evaluate the state of industry fixatives currently in use and set the foundation for comparison to alternative technological solutions. A baseline of five (5) commonly used fixatives and decontamination gels (hereafter collectively referred to as fixatives) was conducted, and notable shortfalls and deficiencies were revealed, particularly when exposed to thermal, water, and other environmental stressors. At temperatures as low as 300 °F - 400 °F (148.89 °C – 204.44 °C), all commonly used fixatives melted from the substrates within 3-5 minutes of exposure, resulting in contaminant transport. Significant degradation in terms of mass loss, desiccation, and off-gassing occurred, and the chemical breakdown of the polymer was so complete researchers assessed there would likely have been a release of residual contamination. Additional vulnerabilities became evident when exposed to water immersion and high humidity; existing fixatives took up water, swelling and frequently delaminating from the substrate, once again increasing the likelihood of a contaminant release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COTS Data Analytics Software User Manual: Version 1.0

Large volumes of data are being collected by Sandia National Laboratories as part of an active commercial-off-the-shelf (COTS) part testing and surveillance program. This user manual documents Python-based COTS Data Analytics software that has been developed for standardizing, displaying, visualizing, and analyzing the resulting COTS part testing and surveillance data. It is the objective of these software tools to streamline the analysis of COTS testing and surveillance data and improve the efficiency with which test engineers and data analytics experts can pinpoint possible performance and reliability problems in COTS parts.

42 ENGINEERING↗

A Demonstration of Intelligent Container Surveillance Using Stationary and Mobile Camera Platforms

Surveillance of nuclear material storage containers is required to ensure that the container safety boundary is maintained during the service life of the container. As many of these container types are the first and only containment barrier to release protecting the worker, public, and environment, it is imperative to develop robust surveillance tools to characterize container degradation. Machine learning (ML) techniques have matured quickly in the past decade and are slowly becoming a routine application in data analysis. While more popular architectures have been developed with different applications in mind, these can be easily translated to container surveillance requirements. In this study, we developed a ML model based on the Detectron2 framework to identify slip lid containers and common exterior container defects, primarily dents. Commercial-off-the-shelf cameras are combined into a stationary camera array or are mounted to a robotic arm to provide more mobility for positioning needs. Results from the model evaluations on the images indicate that the stationary camera arrays outperform the accuracy of the mobile camera systems for both individual camera and composite image detections. Overall, however, the detection accuracies of the systems fell short of 50% and were less than satisfactory. Future efforts to improve the system involve focusing on a single camera deployable solution that combines a controllable light source that eliminates one of the biggest environmental factors that influence ML model detection performance. Additional training set collection is planned to build a more robust model that enables accurate detection from a wider range of imaging conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

TEAMER - Acoustic Particle Velocity Measurements - CRADA 601 (Abstract)

With relatively few deployments of tidal turbines, the extent and effect of underwater sounds generated from these turbines is not well understood. The University of Washington (UW) is deploying a cross-flow turbine system, the Turbine Lander, in the entrance channel to Sequim Bay. The deployment of this system provides an opportunity to understand the noise radiated by the turbine and its sources. There are three hypothesized sound sources associated with operation of the turbine: 1) a continuous tone associated with energized power electronics; 2) sound associated with the generator when the turbine is rotating; and 3) sound associated with the bearing pack that supports the rotor. PNNL is collaborating with UW and Integral Consulting Inc. (Integral) to simultaneously measure sound sources using three different devices. The NoiseSpotter®, an acoustic sensor system designed by Integral, measures acoustic pressure and a three-dimensional particle velocity vector. The NoiseSpotter, along with a commercial-off-the-shelf acoustic particle motion and pressure sensor (M20-105, Geospectrum Technologies Inc.) owned by PNNL will be deployed on the seabed approximately 50-100 m from the Turbine Lander. UW will concurrently deploy Drifting Acoustic Instrumentation SYstems (DAISYs) to characterize acoustic pressure near the Turbine Lander and localize sounds using a Time Delay of Arrival (TDOA) algorithm. Integral, UW, and PNNL will collaborate on data analysis and interpretation, with the intention of jointly authoring an archival paper on the results. The noise generated from the Turbine Lander is not expected to be significant, yet this experiment will help to evaluate the efficacy of combining technologies to characterize noise and provide insights for approaches to consider for future turbine deployments at other locations.

16 TIDAL AND WAVE POWER↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗