Comparing Server Energy Use and Efficiency Using Small Sample Sizes

This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a group is similar to all other components as a group. However, some differences were observed. The Supermicro server used 27 percent more power at idle compared to the other brands. The Intel server had a power supply control feature called cold redundancy, and the data suggest that cold redundancy can provide energy savings at low power levels. Test and evaluation methods that might be used by others having limited resources for IT equipment evaluation are explained in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characteristics and Energy Use of Volume Servers in the United States

Servers’ field energy use remains poorly understood, given heterogeneous computing loads, configurable hardware and software, and operation over a wide range of management practices. This paper explores various characteristics of 1- and 2-socket volume servers that affect energy consumption, and quantifies the difference in power demand between higher-performing SPEC and ENERGY STAR servers and our best understanding of a typical server operating today. We first establish general characteristics of the U.S. installed base of volume servers from existing IDC data and the literature, before presenting information on server hardware configurations from data collection events at a major online retail website. We then compare cumulative distribution functions of server idle power across three separate datasets and explain the differences between them via examination of the hardware characteristics to which power draw is most sensitive. We find that idle server power demand is significantly higher than ENERGY STAR benchmarks and the industry-released energy use documented in SPEC, and that SPEC server configurations—and likely the associated power-scaling trends—are atypical of volume servers. Next, we examine recent trends in server power draw among high-performing servers across their full load range to consider how representative these trends are of all volume servers before inputting weighted average idle power load values into a recently published model of national server energy use. Finally, we present results from two surveys of IT managers (n=216) and IT vendors (n=178) that illustrate the prevalence of more-efficient equipment and operational practices in server rooms and closets; these findings highlight opportunities to improve the energy efficiency of the U.S. server stock.

97 MATHEMATICS AND COMPUTING↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗

Optimization of Selected Remote Sensing Algorithms for Embedded NVIDIA Kepler GPU Architecture

This paper evaluates the potential of embedded Graphic Processing Units in the Nvidias Tegra K1 for onboard processing. The performance is compared to a general purpose multi-core CPU and full fledge GPU accelerator. This study uses two algorithms: Wavelet Spectral Dimension Reduction of Hyperspectral Imagery and Automated Cloud-Cover Assessment (ACCA) Algorithm. Tegra K1 achieved 51 for ACCA algorithm and 20 for the dimension reduction algorithm, as compared to the performance of the high-end 8-core server Intel Xeon CPU with 13.5 times higher power consumption.

Riha, Lubomir↗

Optimization of Selected Remote Sensing Algorithms for Embedded NVIDIA Kepler GPU Architecture

This paper evaluates the potential of embedded Graphic Processing Units (GPUs) in Nvidia's Tegra K1 (based on Kepler (TM) hardware) for onboard processing. The performance is compared to a general purpose multi-core CPU (Central Processing Unit) and a fully-fledged GPU accelerator. This study uses two algorithms: Wavelet Spectral Dimension Reduction of Hyperspectral Imagery and Automated Cloud-Cover Assessment (ACCA) Algorithm. Tegra K1 achieved 51 for the ACCA algorithm and 20 for the dimension reduction algorithm, as compared to the performance of the high-end 8-core server Intel Xeon CPU with 13.5 times higher power consumption.

data reduction↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Land and Atmosphere Near-Real-Time Capability for Earth Observing System

The past decade has seen a rapid increase in availability and usage of near-real-time data from satellite sensors. The EOSDIS (Earth Observing System Data and Information System) was not originally designed to provide data with sufficiently low latency to satisfy the requirements for near-real-time users. The EOS (Earth Observing System) instruments aboard the Terra, Aqua and Aura satellites make global measurements daily, which are processed into higher-level 'standard' products within 8-40 hours of observation and then made available to users, primarily earth science researchers. However, applications users, operational agencies, and even researchers desire EOS products in near-real-time to support research and applications, including numerical weather and climate prediction and forecasting, monitoring of natural hazards, ecological/invasive species, agriculture, air quality, disaster relief and homeland security. These users often need data much sooner than routine science processing allows, usually within 3 hours, and are willing to trade science product quality for timely access. While Direct Broadcast provides more timely access to data, it does not provide global coverage. In 2002, a joint initiative between NASA (National Aeronautics and Space Administration), NOAA (National Oceanic and Atmospheric Administration), and the DOD (Department of Defense) was undertaken to provide data from EOS instruments in near-real-time. The NRTPE (Near Real Time Processing Effort) provided products within 3 hours of observation on a best-effort basis. As the popularity of these near-real-time products and applications grew, multiple near-real-time systems began to spring up such as the Rapid Response System. In recognizing the dependence of customers on this data and the need for highly reliable and timely data access, NASA's Earth Science Division sponsored the Earth Science Data and Information System Project (ESDIS)-led development of a new near-real-time system called LANCE (Land, Atmosphere Near-Real-Time Capability for EOS) in 2009. LANCE consists of special processing elements, co-located with selected EOSDIS data centers and processing facilities. A primary goal of LANCE is to bring multiple near-real-time systems under one umbrella, offering commonality in data access, quality control, and latency. LANCE now processes and distributes data from the Moderate Resolution Imaging Spectroradiometer (MODIS), Atmospheric Infrared Sounder (AIRS), Advanced Microwave Scanning Radiometer Earth Observing System (AMSR-E), Microwave Limb Sounder (MLS) and Ozone Monitoring Instrument (OMI) instruments within 3 hours of satellite observation. The Rapid Response System and the Fire Information for Resource Management System (FIRMS) capabilities will be incorporated into LANCE in 2011. LANCE maintains a central website to facilitate easy access to data and user services. LANCE products are extensively tested and compared with science products before being made available to users. Each element also plans to implement redundant network, power and server infrastructure to ensure high availability of data and services. Through the user registration system, users are informed of any data outages and when new products or services will be available for access. Building on a significant investment by NASA in developing science algorithms and products, LANCE creates products that have a demonstrated utility for applications requiring near-real-time data. From lower level data products such as calibrated geolocated radiances to higher-level products such as sea ice extent, snow cover, and cloud cover, users have integrated LANCE data into forecast models and decision support systems. The table above shows the current near-real-time product categories by instrument. The ESDIS Project continues to improve the LANCE system and use the experience gained through practice to seek adjustments to improve the quality and performance of the system. For example, anGC-compliant Web Map Service (WMS) will be added shortly that will allow users to download geo-referenced MODIS images for arbitrary bounding boxes. Further, an OGC-compliant Web Coverage Service (WCS) will be added later this year that will expedite user access to arbitrary data subsets or re-formatted products. AIRS images are now served through WMS and available in multiple formats (PNG, GeoTIFF, KMZ). NASA has established a LANCE User Working Group to steer the development of the system and create a forum for sharing ideas and experiences that are expected to further improve the LANCE capabilities. The LANCE system has proved a success by satisfying the growing needs of the applications and operational communities for land and atmosphere data in near-real-time. NASA's Earth Sciences Division was able to leverage existing science research capabilities to provide the near-real-time community with products and imagery that support monitoring of disasters in a timely manner.

Murphy, Kevin J.↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighbouring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchains↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power system model parameter conditioning tool

A power system model parameter conditioning tool including a server control processor in communication with phasor measurement unit monitored data records of multiple disturbance events, a model calibration unit providing event screening, power system model simulation, and simultaneous tuning of model parameters. The model calibration performing a simulation using default model parameters, the processor comparing the simulation results to the monitored data. If the prediction is within threshold, then terminating conditioning; else performing parameter identifiability analysis to determine differing effects of various model parameters on power system model accuracy, selecting a parameter set causing a degradation in power system model prediction, and updating the default model parameters corresponding to members of the parameter set with values selected to reduce the degradation. A method and a non-transitory computer readable medium are also disclosed.

Baone, Chaitanya Ashok↗

Validating Safecast data by comparisons to a U. S. Department of Energy Fukushima Prefecture aerial survey

Safecast is a volunteered geographic information (VGI) project where the lay public collects radiation measurements via hand-held sensors that are uploaded to a central server and then made freely available. However, Safecast data fidelity is uncertain given that the these sensors are hand assembled with various levels of technical proficiency, and that the sensors may not be properly deployed. We validated Safecast data gathered in the Fukushima Prefecture shortly after the Daiichi nuclear power plant catastrophe by comparing it with authoritative data collected by the Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) during the same period. We found that the two data sets were highly correlated, though the DOE/NNSA observations were generally higher than the Safecast measurements. We concluded that this high correlation alone makes Safecast a viable data source for detecting and monitoring fallout during radiological emergencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sequence Hopping Algorithm For Securing Goose Messages

Embodiments of the present invention include methods and apparatuses for securing data transfer in power-system automation and smart grids. Embodiments of the present invention can be particularly helpful in securing GOOSE messages. A method of securing data transfer according to an embodiment of the present invention can include a message sequence synchronization and monitoring server (MSSMS) providing random seeds to a publisher intelligent electronic device (IED) and a subscriber IED, both having a pseudo random number generators (PRNGs), inputting the random seeds into the PRNG of the publisher IED and generating a publisher sequence hopping number, sending a message to the subscriber IED with the publisher sequence hopping number attached, and determining if the message is valid by comparing the message attached publisher sequence hopping number to a subscriber sequence hopping number generated by the subscriber PRNG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA SpaceCube Edge TPU SmallSat Card for Autonomous Operations and Onboard Science-Data Analysis

Using state-of-the-art artificial intelligence (AI)frameworks onboard spacecraft is challenging because common spacecraft processors cannot provide comparable performance to datacenters with server-grade CPUs and GPUs available for terrestrial applications and advanced deep-learning networks. This limitation makes small, lo w-p o we r AI microchip architectures, such as the Google Coral Edge Tensor Processing Unit (TPU), attractive for space missions where the application-specific design enables both high-performance and power-efficient computing for AI applications. To address these challenging considerations for space deployment, this research introduces the design and capabilities of a CubeSat-sized Edge TPU-based co-processor card, known as the SpaceCube Low-power Ed g e Artificial Intelligence Resilient Node (SC-LEARN). This design conforms to NASA’s CubeSat Card Specification (CS2) for integration into next-generation SmallSat and CubeSat systems. This paper describes the overarching architecture and design of the SC-LEARN, as well as, the supporting test card designed for rapid prototyping and evaluation. The SC-LEARN was developed with three operational modes: (1) a high-performance parallel-processing mode,(2)a fault-tolerant mode for onboard resilience, and (3) a power-saving mode with cold spares. Importantly, this research also elaborates on both training and quantization of Tensor Flow models for the SC-LEARN for use onboard with representative, open-source datasets. Lastly, we describe future research plans, including radiation-beam testing and flight demonstration.

Advanced avionics↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings and usability of zero-client computing in office settings

This study provides a detailed comparison of the power consumption, usability, and applicability of virtual machines (VMs) - accessed through zero-client devices - and traditional laptop computers in office settings. The study analyzed high-level plug loads across two office spaces, one using traditional laptops, the other using zero clients. In addition, the individual power consumption of four workstations was monitored and compared. Each workstation user switched between using a laptop or zero client for one week and then using the alternate system the second week. Results of the high-level and workstation analysis show that average workstation plug loads are lower for occupants using zero clients. However, this does not include power consumed by the data center managing VMs. This study calculates the affiliated data center power draw of VMs and shows that server-related loads push total zero-client computing energy higher than that of traditional laptops. Finally, a questionnaire was administered to building occupants to determine the appropriateness of zero-client computing for various user groups, with the results indicating that VMs are most appropriate for more basic software functions. The findings of this study suggest that advances in server technology can help improve both the overall efficiency and the usability of zero-client computing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New approach based on group technology for the consolidation problem in cloud computing-mathematical model and genetic algorithm

Resource management is a hotspot issue in distributed systems like cloud computing (CC). It means how to prepare the computational resources, i.e., servers and virtual machines (VMS), to execute the tasks. This paper offers a new approach based on Group Technology (GT)—known as a powerful philosophy for the resource management in cellular manufacturing systems—to deal with the resource management problem in CC. We develop a mathematical model to optimally consolidate the VMs, servers and tasks simultaneously to control several important factors such as task migrations and server load variation, as well as the number of VMs. To test the validity of our proposed model, several small problems are generated randomly and solved by LINGO 9 software. Furthermore, to cope with larger problems, which cannot be solved optimally, a genetic algorithm is proposed. We, finally, compare our methods with the most well-known algorithms in this context, round robin (RR) and first-come, first-served (FCFS) algorithms.

97 MATHEMATICS AND COMPUTING↗

Tropical Cyclone Information System

The JPL Tropical Cyclone Infor ma tion System (TCIS) is a Web portal (http://tropicalcyclone.jpl.nasa.gov) that provides researchers with an extensive set of observed hurricane parameters together with large-scale and convection resolving model outputs. It provides a comprehensive set of high-resolution satellite (see figure), airborne, and in-situ observations in both image and data formats. Large-scale datasets depict the surrounding environmental parameters such as SST (Sea Surface Temperature) and aerosol loading. Model outputs and analysis tools are provided to evaluate model performance and compare observations from different platforms. The system pertains to the thermodynamic and microphysical structure of the storm, the air-sea interaction processes, and the larger-scale environment as depicted by ocean heat content and the aerosol loading of the environment. Currently, the TCIS is populated with satellite observations of all tropical cyclones observed globally during 2005. There is a plan to extend the database both forward in time till present as well as backward to 1998. The portal is powered by a MySQL database and an Apache/Tomcat Web server on a Linux system. The interactive graphic user interface is provided by Google Map.

Li, P. Peggy↗