Search NASA⌕ Search

SEARCH · Search NASA

Results for “complex mixtures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures

Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R{sup 2} = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R{sup 2} = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Persistent activation of DNA damage signaling in response to complex mixtures of PAHs in air particulate matter

Complex mixtures of polycyclic aromatic hydrocarbons (PAHs) are present in air particulate matter (PM) and have been associated with many adverse human health effects including cancer and respiratory disease. However, due to their complexity, the risk of exposure to mixtures is difficult to estimate. In the present study the effects of binary mixtures of benzo[a]pyrene (BP) and dibenzo[a,l]pyrene (DBP) and complex mixtures of PAHs in urban air PM extracts on DNA damage signaling was investigated. Applying a statistical model to the data we observed a more than additive response for binary mixtures of BP and DBP on activation of DNA damage signaling. Persistent activation of checkpoint kinase 1 (Chk1) was observed at significantly lower BP equivalent concentrations in air PM extracts than BP alone. Activation of DNA damage signaling was also more persistent in air PM fractions containing PAHs with more than four aromatic rings suggesting larger PAHs contribute a greater risk to human health. Altogether our data suggests that human health risk assessment based on additivity such as toxicity equivalency factor scales may significantly underestimate the risk of exposure to complex mixtures of PAHs. The data confirms our previous findings with PAH-contaminated soil (Niziolek-Kierecka et al., 2012) and suggests a possible role for Chk1 Ser317 phosphorylation as a biological marker for future analyses of complex mixtures of PAHs. -- Highlights: ► Benzo[a]pyrene (BP), dibenzo[a,l]pyrene (DBP) and air PM PAH extracts were compared. ► Binary mixture of BP and DBP induced a more than additive DNA damage response. ► Air PM PAH extracts were more potent than toxicity equivalency factor estimates. ► Larger PAHs (> 4 rings) contribute more to the genotoxicity of PAHs in air PM. ► Chk1 is a sensitive marker for persistent activation of DNA damage signaling from PAH mixtures.

60 APPLIED LIFE SCIENCES↗

Effective Ion Mobility Peak Width as a New Isomeric Descriptor for the Untargeted Analysis of Complex Mixtures Using Ion Mobility-Mass Spectrometry

Ion mobility coupled with mass spectrometry was proven to be an efficient way to characterize complex mixtures such as petroleum samples. However, the identification of isomeric species is difficult owing to the molecular complexity of petroleum and no availability of standard molecules. This paper proposes a new simple indicator to estimate the isomeric content of highly complex mixtures. This indicator is based on the full width at half maximum (FWHM) of the extracted ion mobility peak measured in millisecond or square angstrom that is corrected for instrumental factors such as ion diffusion. This value can be easily obtained without precisely identifying the number of isomeric species under the ion mobility peaks. Considering the Boduszynski model, the ion mobility profile for a particular elemental composition is expected to be a continuum of various isomeric species. The drift time-dependent fragmentation profile was studied and confirmed this hypothesis, a continuous evolution of the fragmentation profile showing that the larger alkyl chain species were detected at higher drift time values. This new indicator was proven to be a fast and efficient method to compare vacuum gas oils for which no difference was found using other analytical techniques. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative comparison of combined gas chromatographic/mass spectrometric profiles of complex mixtures

The paper describes a method called HISLIB for automatic quantitative comparison of gas chromatographic/mass spectrometric (GC/MS) results obtained on complex mixtures of organic compounds. The method is based on comparing new mixtures to 'historical' libraries of previous results. Co-occurrence of components is determined by matching relative retention indices (RRIs) and mass spectra after background removal and resolution of overlapping GC components. Internal standards are used to quantify the relative concentrations of components. Applications of HISLIB include validation of analytical procedures to isolate complex mixtures; development of historical libraries which might include complete summaries of all past observations, compilations of controls, or any other selected subset of results; improvement of the quality of existing libraries of mass spectral data; and detection of differences in kind and/or amounts of individual components. Limitations of the method are mentioned along with causes of their occurrence.

Smith, D. H.↗

Liquid class predictor for liquid handling of complex mixtures

A method of establishing liquid classes of complex mixtures for liquid handling equipment. The mixtures are composed of components and the equipment has equipment parameters. The first step comprises preparing a response curve for the components. The next step comprises using the response curve to prepare a response indicator for the mixtures. The next step comprises deriving a model that relates the components and the mixtures to establish the liquid classes.

47 OTHER INSTRUMENTATION↗

PyKrev: A Python Library for the Analysis of Complex Mixture FT-MS Data

In this study, we present PyKrev, a Python library for the analysis of complex mixture Fourier transform mass spectrometry (FT-MS) data. PyKrev is a comprehensive suite of tools for analysis and visualization of FT-MS data after formula assignment has been performed. These comprise formula manipulation and calculation of chemical properties, intersection analysis between multiple lists of formulas, calculation of chemical diversity, assignment of compound classes to formulas, multivariate analysis, and a variety of visualization tools producing van Krevelen diagrams, class histograms, PCA score, and loading plots, biplots, scree plots, and UpSet plots. The library is showcased through analysis of hot water green tea extracts and Scotch whisky FT-ion cyclotron resonance-MS data sets. PyKrev addresses the lack of a single, cohesive toolset for researchers to perform FT-MS analysis in the Python programming environment encompassing the most recent data analysis techniques used in the field.

47 OTHER INSTRUMENTATION↗

Comprehensive Metabolite Identification Strategy Using Multiple Two-Dimensional NMR Spectra of a Complex Mixture Implemented in the COLMARm Web Server

Identification of metabolites in complex mixtures represents a key step in metabolomics. A new strategy is introduced, which is implemented in a new public web server, COLMARm, that permits the co-analysis of up to three 2D NMR spectra, namely 13C-1H HSQC, 1H-1H TOCSY, and 13C-1H HSQC-TOCSY for the comprehensive, accurate, and efficient performance of this task. The highly versatile and interactive nature of COLMARm permits its application to a wide range of metabolomics samples independent of the magnetic field. Database query is performed using the HSQC spectrum and the top metabolite hits are then validated against the TOCSY-type experiment(s) by superimposing the expected cross-peaks on the mixture spectrum. In this way the user can directly accept or reject candidate metabolites by taking advantage of the complementary spectral information offered by these experiments and their different sensitivities. The power of COLMARm is demonstrated for a human serum sample uncovering the existence of 14 metabolites that hitherto were not identified by NMR.

Bingol, Kerem↗

Improved Resolution of Hydrocarbon Structures and Constitutional Isomers in Complex Mixtures Using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry

Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography/mass spectrometry (GC/MS) techniques. In this study, we use vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally “unresolved complex mixture” by separating components by GC retention time, t R , and mass-to-charge ratio, m/z, which are used to determine carbon number, N C , and the number of rings and double bonds, N DBE . Constitutional isomers are resolved on the basis of t R , enabling the most complete quantitative analysis to date of structural isomers in an environmentally relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. Lastly, the classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved resolution of hydrocarbon structures and constitutional isomers in complex mixtures using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry (GC-VUV-MS)

Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography-mass spectrometry (GC-MS) techniques. This work uses vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally"unresolved complex mixture" by separating components by GC retention time, tR, and mass-to-charge ratio, m/Q, which are used to determine carbon number, NC, and the number of rings and double bonds, NDBE. Constitutional isomers are resolved based on tR, enabling the most complete quantitative analysis to date of structural isomers in an environmentally-relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. The classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterisation of metals in the electronic waste of complex mixtures of end-of-life ICT products for development of cleaner recovery technology

Highlights: • New characterisation methodology has been established to understand an industrially processed ICT waste. • Particle size distribution, composition, thermal–chemical behaviour and occurrence of metals were considered. • The characterisation provides direct guidelines for values recovery from the waste. - Abstract: Recycling of valuable metals from electronic waste, especially complex mixtures of end-of-life information and communication technology (ICT) products, is of great difficulty due to their complexity and heterogeneity. One of the important reasons is the lack of comprehensive characterisation on such materials, i.e. accurate compositions, physical/chemical properties. In the present research, we focus on developing methodologies for the characterisation of metals in an industrially processed ICT waste. The morphology, particle size distribution, compositional distribution, occurrence, liberation as well as the thermo-chemical properties of the ICT waste were investigated with various characterisation techniques, including X-ray Fluorescence Spectrometry (XRF), differential scanning calorimetry (DSC) and scanning electron microscopy (SEM) with energy dispersed spectroscopy (EDS). Due to the high heterogeneity of the material, special sample preparation procedures were introduced to minimise the discrepancies during compositional analyses. As a result, a clearer overview of the ICT waste has been reached. This research provides better understanding of the extractability of each metal and improves the awareness of potential obstacles for extraction. It will lead to smarter decisions during further development of a clean and effective recovery process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method of analysis of polymerizable monomeric species in a complex mixture

Method of selective quantitation of a polymerizable monomeric species in a well spacer fluid, said method comprising the steps of adding at least one solvent having a refractive index of less than about 1.33 to a sample of the complex mixture to produce a solvent phase, and measuring the refractive index of the solvent phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondispersive infrared analyzer for specific gases in complex mixtures

Analyzer identifies and measures particular diatomic or polyatomic gases in complex gas mixtures. Mixing of absorption effects on light energy passing through gases to photodetector produces a signal component that is related to the absorption caused by reference-gas component in unknown gas mixture.

Dimeff, J.↗

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a preferred technique for analyzing complex organic mixtures. Currently, there is no consensus normalization approach, nor an objective method for selecting one, for quantitative analyses of FT-ICR-MS data. We investigate a method to evaluate and score the amount of bias various normalization approaches introduce into the data. We evaluate the ability of the Statistical Procedure for the Analysis of Normalization Strategies (SPANS) to guide selection of appropriate normalization approaches for two different FT-ICR-MS datasets. Further, we test the robustness of SPANS results to changes in SPANS parameter values and assess the impact of using various normalization approaches on downstream statistical analyses. The normalization approach identified by SPANS differed for the two datasets. Normalization methods impacted the statistical significance of peaks differently, underscoring the importance of carefully evaluating potential methods. More consistent SPANS scores resulted when at least 120 significant peaks are used, where larger sets of peaks were obtained by increasing the p-value threshold. Interestingly, we show that Total Sum Scaling and highest peak normalization, used in previous studies, underperformed relative to SPANS-recommended normalization approaches. While there is no single, best normalization method for all datasets, SPANS provides a mechanism to identify an appropriate normalization method for analyzing FT-ICR-MS data quantitatively. As a result, the number of peaks used in the background distributions of SPANS contributes more significantly to the reproducibility of results than the p-value thresholds used to obtain those peaks.

47 OTHER INSTRUMENTATION↗

Final Technical Report: Transport of Complex Mixtures in Ion-Containing Polymer Membranes

Permselective ion-containing membranes are an integral component for many applications from water treatment, fuel cells, and solar fuels devices where the selective transport of molecules and ions is desired. In solar fuels devices, ion-containing polymer membranes are responsible for permitting selective transport of ions between electrodes to maintain overall charge neutrality yet limit transport of reaction products produced at the electrodes. While the transport of single solutes through such membranes has been fairly well described, binary and multicomponent transport is poorly understood due to the myriad of interactions that occur in these systems (i.e. between co-permeants and between permeants and the membrane). Solar fuels devices are just one example of an application where understanding the transport of multiple simultaneous species is critically important to improving device performance as product crossover leads to reductions in overall device performance. The objectives of this research was to improve our understanding of the complex array of factors that influence transport behavior of multiple solutes within ion-containing polymer membranes. This experimental project addressed the lack of fundamental understanding of multicomponent transport behavior by synthesizing ion exchange membranes with varied incorporation of comonomers (ionic and neutral moieties) to investigate fundamental relationships between membrane structure, membrane physiochemical properties, and transport behavior of solutes and complex solute mixtures through dense, hydrated membranes.

25 ENERGY STORAGE↗