Search NASA⌕ Search

SEARCH · Search NASA

Results for “complexity metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessing software upgrades, plan properties and patient geometry using intensity modulated radiation therapy (IMRT) complexity metrics

Purpose: The aim of this study is to compare the sensitivity of different metrics to detect differences in complexity of intensity modulated radiation therapy (IMRT) plans following upgrades, changes to planning parameters, and patient geometry. Correlations between complexity metrics are also assessed. Method: A program was developed to calculate a series of metrics used to describe the complexity of IMRT fields using monitor units (MUs) and multileaf collimator files: Modulation index (MI), modulation complexity score (MCS), and plan intensity map variation (PIMV). Each metric, including the MUs, was used to assess changes in beam complexity for six prostate patients, following upgrades in the inverse planning optimization software designed to incorporate direct aperture optimization (DAO). All beams were delivered to a 2D ionization chamber array and compared to those calculated using gamma analysis. Each complexity metric was then calculated for all beams, on a different set of six prostate IMRT patients, to assess differences between plans calculated using different minimum field sizes and different maximum segment numbers. Different geometries, including CShape, prostate, and head and neck phantoms, were also assessed using the metrics. Correlations between complexity metrics were calculated for 20 prostate IMRT patients. Results: MU, MCS, MI, and PIMV could all detect reduced complexity following an upgrade to the optimization leaf sequencer, although only MI and MCS could detect a reduction in complexity when one-step optimization (DAO) was employed rather than two-step optimization. All metrics detected a reduction in complexity when the minimum field size was increased from 1 to 4 cm and all apart from PIMV detected reduced complexity when the number of segments was significantly reduced. All metrics apart from MI showed differences in complexity depending on the treatment site. Significant correlations exist between all metrics apart from MI and PIMV for prostate IMRT patients. Treatment deliverability appeared to be more correlated with MI and MCS than MU or PIMV. Conclusions: The application of complexity metrics in the IMRT treatment planning process has been demonstrated. Complexity of treatment plans can vary for different inverse planning software versions and can depend on planning parameters and the treatment site. MCS is most suitable for inclusion within the cost function to limit complexity in IMRT optimization due to its sensitivity to complexity changes and correlation to treatment deliverability.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of aperture-based complexity metrics using film and EPID measurements of static MLC openings

Purpose: Complexity metrics have been suggested as a complement to measurement-based quality assurance for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). However, these metrics have not yet been sufficiently validated. This study develops and evaluates new aperture-based complexity metrics in the context of static multileaf collimator (MLC) openings and compares them to previously published metrics. Methods: This study develops the converted aperture metric and the edge area metric. The converted aperture metric is based on small and irregular parts within the MLC opening that are quantified as measured distances between MLC leaves. The edge area metric is based on the relative size of the region around the edges defined by the MLC. Another metric suggested in this study is the circumference/area ratio. Earlier defined aperture-based complexity metrics—the modulation complexity score, the edge metric, the ratio monitor units (MU)/Gy, the aperture area, and the aperture irregularity—are compared to the newly proposed metrics. A set of small and irregular static MLC openings are created which simulate individual IMRT/VMAT control points of various complexities. These are measured with both an amorphous silicon electronic portal imaging device and EBT3 film. The differences between calculated and measured dose distributions are evaluated using a pixel-by-pixel comparison with two global dose difference criteria of 3% and 5%. The extent of the dose differences, expressed in terms of pass rate, is used as a measure of the complexity of the MLC openings and used for the evaluation of the metrics compared in this study. The different complexity scores are calculated for each created static MLC opening. The correlation between the calculated complexity scores and the extent of the dose differences (pass rate) are analyzed in scatter plots and using Pearson’s r-values. Results: The complexity scores calculated by the edge area metric, converted aperture metric, circumference/area ratio, edge metric, and MU/Gy ratio show good linear correlation to the complexity of the MLC openings, expressed as the 5% dose difference pass rate, with Pearson’s r-values of −0.94, −0.88, −0.84, −0.89, and −0.82, respectively. The overall trends for the 3% and 5% dose difference evaluations are similar. Conclusions: New complexity metrics are developed. The calculated scores correlate to the complexity of the created static MLC openings. The complexity of the MLC opening is dependent on the penumbra region relative to the area of the opening. The aperture-based complexity metrics that combined either the distances between the MLC leaves or the MLC opening circumference with the aperture area show the best correlation with the complexity of the static MLC openings.

60 APPLIED LIFE SCIENCES↗

SU-F-T-312: Identifying Distinct Radiation Therapy Plan Classes Through Multi-Dimensional Analysis of Plan Complexity Metrics

Purpose: To determine whether body site-specific treatment plans form unique “plan class” clusters in a multi-dimensional analysis of plan complexity metrics such that a single beam quality correction determined for a representative plan could be universally applied within the “plan class”, thereby increasing the dosimetric accuracy of a detector’s response within a subset of similarly modulated nonstandard deliveries. Methods: We collected 95 clinical volumetric modulated arc therapy (VMAT) plans from four body sites (brain, lung, prostate, and spine). The lung data was further subdivided into SBRT and non-SBRT data for a total of five plan classes. For each control point in each plan, a variety of aperture-based complexity metrics were calculated and stored as unique characteristics of each patient plan. A multiple comparison of means analysis was performed such that every plan class was compared to every other plan class for every complexity metric in order to determine which groups could be considered different from one another. Statistical significance was assessed after correcting for multiple hypothesis testing. Results: Six out of a possible 10 pairwise plan class comparisons were uniquely distinguished based on at least nine out of 14 of the proposed metrics (Brain/Lung, Brain/SBRT lung, Lung/Prostate, Lung/SBRT Lung, Lung/Spine, Prostate/SBRT Lung). Eight out of 14 of the complexity metrics could distinguish at least six out of the possible 10 pairwise plan class comparisons. Conclusion: Aperture-based complexity metrics could prove to be useful tools to quantitatively describe a distinct class of treatment plans. Certain plan-averaged complexity metrics could be considered unique characteristics of a particular plan. A new approach to generating plan-class specific reference (pcsr) fields could be established through a targeted preservation of select complexity metrics or a clustering algorithm that identifies plans exhibiting similar modulation characteristics. Measurements and simulations will better elucidate potential plan-class specific dosimetry correction factors.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

SU-E-T-76: A Software System to Monitor VMAT Plan Complexity in a Large Radiotherapy Centre

Purpose: To develop a system that analyses and reports the complexity of Volumetric Modulated Arc Therapy (VMAT) plans to aid in the decision making for streamlining patient specific dosimetric quality assurance (QA) tests. Methods: A software system, Delcheck, was developed in-house to calculate VMAT plan and delivery complexity using the treatment delivery file. Delcheck has the functionality to calculate multiple plan complexity metrics including the Li-Xing Modulation Index (LI-MI), multiplicative combination of Leaf Travel and Modulation Complexity Score (LTMCSv), Monitor Units per prescribed dose (MU/D) and the delivery complexity index (MIt) that incorporates the modulation of dose rate, leaf speed and gantry speed. Delcheck includes database functionality to store and compare plan metrics for a specified treatment site. The overall plan and delivery complexity is assessed based on the 95% conformance limit of the complexity metrics as Similar, More or Less complex. The functionality of the software was tested using 42 prostate conventional, 10 prostate SBRT and 15 prostate bed VMAT plans generated for an Elekta linear accelerator. Results: The mean(σ) of LI-MI for conventional, SBRT and prostate bed plans were 1690(486), 3215.4(1294) and 3258(982) respectively. The LTMCSv of the studied categories were 0.334(0.05), 0.325(0.07) and 0.3112(0.09). The MU/D of the studied categories were 2.4(0.4), 2.7(0.7) and 2.5(0.5). The MIt of the studied categories were 21.6(3.4), 18.2(3.0) and 35.9(6.6). The values of the complexity metrics show that LI-MI appeared to resolve the plan complexity better than LTMCSv and MU/D. The MIt value increased as the delivery complexity increased. Conclusion: The developed software was shown to be working as expected. In studied treatment categories Prostate bed plans are more complex in both plan and delivery and SBRT is more complex in plan and less complex in delivery as demonstrated by LI-MI and MIt. This project was funded through a Cancer Council NSW Project Grant (RG14-11)

60 APPLIED LIFE SCIENCES↗

Structural properties of scandium inorganic salts

Here, the structural properties of reported inorganic scandium (Sc) salts were reviewed, including the halide (Cl, Br, and I), nitrate, sulfate, and phosphate salts. Additional analytical techniques used for characterization of these complexes (metrical data, FTIR and 45 Sc NMR spectroscopy) were tabulated. A structural comparison of Sc to select lanthanide (La, Gd, Lu) salt complexes was briefly evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Data Processing Pipeline for Adversarial Socio-Technical Network Analysis

With the rapid adoption of emerging technologies, there is a need to catalog and model sociotechnical interdependencies that have been historically used to influence the operation of Critical Infrastructure networks including the impacts of mergers and acquisitions, hostile takeovers, and foreign investment. Our research intends to address this need with two primary contributions. First, we have developed a data curation and processing pipeline to generate sociotechnical networks extracted from a variety of data sources including SEC filings and infrastructure asset databases. The pipeline, implemented in Apache Airflow, extracts and normalizes the representation of entities and relations, specified within ontologies. Our intent is to provide an extensible, machine-actionable approach to quickly communicate such models, reproduce previous results, and adapt them to new, unanticipated situations. Second, networks produced by our pipeline enable the development of graph-theoretic metrics that consider the properties of network components in addition to its topology. Metadata associated with network components---whether semantic, temporal, or geospatial---affects the alignment of generated networks with assumptions underlying complexity metrics. Validation of generated networks relative to component types defined by an ontology, may allow the research community to adapt metrics to the semantics of the domains being studied. Generated networks may be processed as knowledge, dynamic, or spatial graphs and enables a variety of analyses including automated reasoning and measures of network complexity. Automated reasoning views extracted entities and relations as a knowledge graph; this enables application of inference rules that represent historically-attested adversarial business methods and applies that behavior to a specific geographic context. Measures of network complexity, including degree distribution, reachability analyses, temporal analysis, and community detection can be adapted to indicate adversarial organizational influence.

97 MATHEMATICS AND COMPUTING↗

Incorporating Love- and Rayleigh-wave magnitudes, unequal earthquake and explosion variance assumptions and interstation complexity for improved event screening

Our objective is to improve seismic event screening using the properties of surface waves, We are accomplishing this through (1) the development of a Love-wave magnitude formula that is complementary to the Russell (2006) formula for Rayleigh waves and (2) quantifying differences in complexities and magnitude variances for earthquake and explosion-generated surface waves. We have applied the M{sub s} (VMAX) analysis (Bonner et al., 2006) using both Love and Rayleigh waves to events in the Middle East and Korean Peninsula, For the Middle East dataset consisting of approximately 100 events, the Love M{sub s} (VMAX) is greater than the Rayleigh M{sub s} (VMAX) estimated for individual stations for the majority of the events and azimuths, with the exception of the measurements for the smaller events from European stations to the northeast. It is unclear whether these smaller events suffer from magnitude bias for the Love waves or whether the paths, which include the Caspian and Mediterranean, have variable attenuation for Love and Rayleigh waves. For the Korean Peninsula, we have estimated Rayleigh- and Love-wave magnitudes for 31 earthquakes and two nuclear explosions, including the 25 May 2009 event. For 25 of the earthquakes, the network-averaged Love-wave magnitude is larger than the Rayleigh-wave estimate. For the 2009 nuclear explosion, the Love-wave M{sub s} (VMAX) was 3.1 while the Rayleigh-wave magnitude was 3.6. We are also utilizing the potential of observed variances in M{sub s} estimates that differ significantly in earthquake and explosion populations. We have considered two possible methods for incorporating unequal variances into the discrimination problem and compared the performance of various approaches on a population of 73 western United States earthquakes and 131 Nevada Test Site explosions. The approach proposes replacing the M{sub s} component by M{sub s} + a* {sigma}, where {sigma} denotes the interstation standard deviation obtained from the stations in the sample that produced the M{sub s} value. We replace the usual linear discriminant a* M{sub s}+b*{sub m{sub b}} with a* M{sub s}+b*{sub m{sub b}} + C*{sigma}. In the second approach, we estimate the optimum hybrid linear-quadratic discriminant function resulting from the unequal variance assumption. We observed slight improvement for the discriminant functions resulting from the theoretical interpretations of the unequal variance function. We have also studied the complexity of the ''magnitude spectra'' at each station. Our hypothesis is that explosion spectra should have fewer focal mechanism-produced complexities in the magnitude spectra than earthquakes. We have developed an intrastation ''complexity'' metric {Delta}M{sub s}, where {Delta}M{sub s} = M{sub s}(i)-M{sub s}(i+1) at periods, i, which are between 9 and 25 seconds. The complexity by itself has discriminating power but does not add substantially to the conditional hybrid discriminant that incorporates the differing spreads of the earthquake and explosion standard deviations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗