Search NASA⌕ Search

SEARCH · Search NASA

Results for “comprehensive two-dimensional gas chromatography (GC×GC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development of gas chromatographic pattern recognition and classification tools for compliance and forensic analyses of fuels: A review

Gas chromatography (GC) is undoubtedly the analytical technique of choice for analyzing the composition of petroleum-based fuels. Over the past twenty years, as comprehensive two-dimensional gas chromatography (GC×GC) has evolved, fuel analysis has often been highlighted in scientific reports, as their complexity allows for illustration of the impressive peak capacity gains afforded by GC×GC. Indeed, several research groups in recent years have applied GC×GC and chemometrics to demonstrate the potential of these analytical tools to address important compliance (tax evasion, tax credits, physical quality standards) and forensic (arson investigations, oil spills) applications involving fuels. None the less, routine use of GC×GC in forensic laboratories has been limited largely by (1) legal and regulatory guidelines, (2) lack of chemometrics training, and (3) concerns about the reproducibility of GC×GC. The goal of this review is to highlight recent advances in one-dimensional GC (1D-GC) and GC×GC analyses of fuels for compliance and forensic applications, in an effort to assist scientists in overcoming the aforementioned hindrances. An introduction to 1D-GC principles, GC×GC technology (column stationary phases and modulators) and several chemometric techniques will be provided. More specifically, chemometric techniques will be broken down into (1) signal pre-processing, (2) peak decomposition, identification and quantification, and (3) classification and pattern recognition. Examples of compliance and forensic applications will be discussed, with particular emphasis on the demonstrated success of the employed chemometric techniques. Overall, this review will hopefully make 1D-GC and GC×GC coupled with chemometric data analysis tools more accessible to the larger scientific community, and aid in eventual widespread standardization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorinated ionic liquids as gas chromatographic stationary phases for the separation of volatile per- and polyfluoroalkyl substances

Background Here, the production of fluorinated organic compounds in the manufacturing, semiconductor, and pharmaceutical industries has increased exponentially over the past decade. This rapid growth has created an urgent need for efficient chromatographic platforms capable of selectively separating these compounds from complex mixtures, not only to support industrial quality control and waste management practices, but also to enable reliable environmental monitoring of volatile fluorinated contaminants. Conventional GC stationary phases lack the fluorophilic interactions needed for highly fluorinated analytes. Consequently, there is a clear demand for specialized stationary phases designed to improve chromatographic retention and selectivity for these compounds. Results Three stationary phases composed of fluorinated ionic liquids (ILs) with varied extent of fluorination were prepared to study fluorophilic interactions with fluorinated/non-fluorinated probe molecules by gas chromatography (GC). IL stationary phases featuring linear and branched perfluoroalkyl moieties, as well as a branched alkyl moiety, were systematically investigated. Chromatographic performance was examined using fluorinated compounds and their hydrocarbon analogs, including CF 3 -substituted aromatics, aliphatic alcohols, fluorotelomer alcohols (FTOHs), and perfluoroalkenes. Measurements on 5 m and 20 m columns revealed that the IL possessing branched alkyl provided stronger dispersive and hydrogen bonding interactions toward non-fluorinated aromatic and long-chain alcohols, whereas the fluorinated ILs enhanced retention of highly fluorinated FTOHs and perfluorodecene. Comprehensive two-dimensional GC (GC × GC), using a nonpolar primary column coupled with secondary columns featuring cross-bonded poly(trifluoropropylmethyl siloxane) (Rtx-200 ms), the branched fluorinated IL, or the branched non-fluorinated IL, highlighted complementary selectivity with the branched fluorinated IL providing the strongest interactions with fluorinated analytes. Significance These results demonstrate that fluorinated IL stationary phases are promising alternatives to conventional polysiloxane stationary phases for improving the separation of per- and polyfluoroalkyl substances and related fluorinated compounds. By correlating IL structure with fluorophilic interactions, this work establishes design principles for GC stationary phases that enable enhanced selectivity for highly fluorinated analytes while maintaining complementary interactions with non-fluorinated compounds.

Comprehensive two-dimensional GC↗

Evaluation of different getter substrates using two-dimensional gas chromatography with time of flight mass spectrometry

We report while understanding hydrogen uptake by organic based getters such as 1,4-bis(phenylethynyl)benzene (DEB) combined with a palladium(0)bis(dibenzylideneacetone) (Pd(dba) 2 ) catalyst is essential, another crucial element to understand is the decomposition of the DEB, Pd(dba) 2 , and/or substrate material. The breakdown of these materials may create unwanted volatiles, which may interact with and lead to deterioration of sensitive materials. Moreover, it is critical to understand if different substrates cause the getter and/or catalyst to degrade in different manners. Utilizing comprehensive two-dimensional gas chromatography (GC×GC) with time-of-flight mass spectrometry (TOFMS), the presence of volatiles located in the headspace of various DEB/Pd(dba) 2 getter substrates is examined. These samples include a getter infused silicone foam, a hydrogenated getter infused silicone foam, an activated carbon getter pellet, and a hydrogenated activated carbon getter pellet. Application of Fisher ratio (F-ratio) analyses lead to the identification of several compounds that are generated or consumed through the hydrogenation process. These include benzene derivatives such as bibenzyl, benzaldehyde, and vinyl benzoate in the activated carbon pellets and 1,5-diphenyl-3-pentanone, toluene, styrene, and 1–1'(2-pentene 1,5-diyl)bis benzene in the silicone foams, and alkane/alkene derivatives such undecane, 4-tridecene, and decane in the activated carbon pellets and 2,6-dimethyl undecane in the silicone foams. Further comparison of the different hydrogenated getter substrates (e.g. activated carbon pellet and silicone foam) indicates that the different substrates alter the decomposition products created from the degradation of the DEB and Pd(dba) 2 .

47 OTHER INSTRUMENTATION↗

Comprehensive two-dimensional gas chromatography under low-pressure conditions

The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC × GC), allows for resolution of compounds that would typically coelute using GC. Here, in this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC × GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC × GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 °C less on the low-pressure GC × GC-TOFMS configuration compared to the conventional GC × GC-TOFMS configuration. Moreover, the compounds were separated in ~13 min on the low-pressure GC × GC-TOFMS as opposed to 33 min for conventional GC × GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC × GC-TOFMS had a lower, β corrected 2D peak capacity, n c,β,2D , of 1260 while the conventional GC × GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC × GC-TOFMS, respectively. A “real world” sample of diesel fuel was tested on the low-pressure and conventional GC × GC-TOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC × GC-TOFMS configuration was higher than that of the conventional GC × GC-TOFMS method.

47 OTHER INSTRUMENTATION↗

Intrinsic Kinetics of Polyethylene Terephthalate Pyrolysis via Micropyrolysis and Multivariate Chromatographic Analysis

This study provides an in-depth investigation of the primary decomposition of polyethylene terephthalate (PET) via pyrolysis, employing an experimental-analytic workflow that integrates design of experiments (DoE), micropyrolysis coupled with comprehensive two-dimensional gas chromatography (GC×GC), and multivariate data analysis to verify intrinsic kinetic conditions and elucidate evolving product distributions for mapping key reaction pathways. Peaks that could not be identified using commercial spectral libraries were assigned using Mass Frontier simulations, enabling the identification of divinyl terephthalate, ethyl vinyl terephthalate, and 2-(benzoyloxy)ethyl vinyl terephthalate. A polar×polar (non-orthogonal) column set tailored for the detection of carboxylic acids enhanced the quantification of benzoic acid, 4-vinylbenzoic acid, 4-ethylbenzoic acid, and methylbenzoic acid by up to 6-fold relative to an orthogonal column combination (non-polar×mid-polar). Moreover, pyrolysis variables were systematically evaluated using a Box- Behnken design (BBD), encompassing pyrolysis temperature (500−600 °C), sample weight (50−150 μg), and carrier gas flow rate (100−300 mL min −1 ). Among these, pyrolysis temperature was the only statistically significant factor influencing product yields, ranging from 58.78 to 84.26 wt %. In contrast, neither the sample weight nor the carrier gas flow rate had a significant effect on product yields within the evaluated experimental space. At 600 °C, the major pyrolysis products were benzoic acid (up to 20.20 ± 1.46 wt %) and CO 2 (up to 21.28 ± 1.46 wt %), which can be produced through decarboxylation reactions. These findings underscore the critical importance of selecting appropriate analytical columns for the accurate quantification of heteroatomcontaining products such as carboxylic acids, which may otherwise be underestimated or undetected due to their reactivity with the stationary phase of non-polar and mid-polar columns, as well as other GC components. They also highlight the importance of selecting pyrolysis conditions for investigating the primary decomposition of PET under an isothermal kinetically limited regime.

aromatic compounds↗

An In Situ , Automated High-Explosives Aging Method Utilizing Two-Dimensional Gas Chromatography–Mass Spectrometry

Understanding chemical changes that occur in high explosives as they age is of great importance to the safe employment and storage of these compounds. Traditional methods of aging high explosives even under accelerated aging conditions are time intensive with durations on the order of months to years. The nature of traditional aging analyses reduces each sample to a snapshot data point often separated widely in time, requiring many assumptions as to how the degradation products develop. Further complicating matters, several analytical techniques are typically employed for each sample analysis in order to ascertain an entire picture of the decomposition pathways. To address these shortcomings with existing methods, a new method of accelerated aging of high explosives utilizing comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry (GC × GC-HRMS) was developed using 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) as a model compound for method development. This in situ automated method reduces the time scale of aging to a matter of hours using the inlet of the GC × GC as the aging vessel. GC × GC in combination with HRMS allowed for the collection of both evolved gases and other decomposition products produced during the entire aging process in real time with HRMS providing far greater certainty in identification of explosives aging products. Additionally, this method allowed for a higher throughput of samples with greatly simplified sample preparation. Chemometric analysis of the GC × GC-HRMS data set via the alteration analysis (ALA) enabled discovery of statistically significant chemical changes providing insight into the variation of decomposition pathways with varying aging temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Inventory and Comparative Organic Profiling of A Homogenized Aggregate Sample From Asteroid (101955) Bennu

Evaluating the distribution and diversity of solvent-soluble organic molecules in extraterrestrial materials provide information about the physicochemical environments where prebiotic chemistry occurred and is essential for assessing the inventory of prebiotic compounds available to the early Earth. In this work, we conducted a comprehensive molecular characterization of solvent-soluble organic compounds in a homogenized aggregate sample (ID: OREX-800107-128) of unsorted regolith from asteroid (101955) Bennu returned by NASA’s OSIRIS-REx mission. Using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HRMS), we identified 87 organic compounds across several molecular classes, including alkanes, polycyclic aromatic hydrocarbons, and nitrogen-, oxygen-, and sulfur-bearing species. Comparison with the organic inventory of CI (Orgueil), C2-ungrouped (Tagish Lake and Tarda), and CM2 (Murchison) carbonaceous chondrites revealed that Bennu sample OREX-800107-128 is most similar to Tagish Lake and Tarda yet compositionally distinct from all of these meteorites. This Bennu sample exhibits a relatively high abundance of low-molecular-weight aromatics (e.g., toluene), pyridine derivatives, and sulfur species such as dimethyl sulfite, consistent with episodic low-temperature aqueous alteration. The presence of these organic compounds suggests that this material experienced chemically diverse processes in the parent body conducive to complex organic synthesis, including aldol condensation reactions responsible for N- and O-bearing compounds. We also compared the molecular distributions of this Bennu sample and previously analyzed samples from (162173) Ryugu to assess potential common origins between these two carbonaceous asteroids. Bennu shows more chemically diverse and nitrogen-rich organic materials than Ryugu. While both asteroids share broadly similar primitive compositions, the observed chemical differences indicate distinct evolutionary histories within a likely common formation environment though whether Bennu and Ryugu derive from a single compositionally heterogeneous parent body or from multiple closely related progenitors remains unresolved. Further detailed comparative analyses of material from Bennu, Ryugu, and specific carbonaceous meteorites (e.g., Tagish Lake and Tarda) will provide new insights into how the N-rich molecular profile observed in Bennu samples was formed and evolved in the outer Solar System.

sample return↗