Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressibility factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Turbulent mixing in supercritical jets: effect of compressibility factor and inflow condition

Fuel injection and turbulent mixing at supercritical pressures determines ignition and combustion in numerous engineering applications. Flow evolution under such conditions is characterized by strong non-linear coupling between dynamics, transport coefficients, and thermodynamics. Experimental studies observe that the jets injected at supercritical pressures exhibit significantly different dynamics from the jets at subcritical conditions, owing to the lack of distinct liquid and gas phases in supercritical state. Thus, the averaged flow quantities such as the potential core length, jet spatial growth rate and velocity decay profiles differ in the two conditions, resulting in different mixed-fluid distributions. In this study, turbulent jet direct numerical simulations (DNS) are performed to examine the variations in flow statistics between injection of Nitrogen (N₂) in Nitrogen (N₂) at both subcritical (perfect-gas) and supercritical conditions. In all cases, isothermal round jets at Reynolds number (Re_{D}), based on jet diameter (D) and jet orifice velocity (U₀), of 5000 are considered. For mixing analyses, a passive scalar transported with the flow is examined.

Sharan, Nek↗

Potential capabilities for compression of information of certain data processing systems

This article undertakes to study a generalized block diagram of a data collection and processing system of a spacecraft in which a number of sensors or outputs of scientific instruments are cyclically interrogated by a commutator, methods of writing the supplementary information in a frame on the example of a certain hypothetical telemetry system, and the influence of statistics of number of active channels in a frame on frame compression factor. The separation of the data compression factor of the collection and processing system of spacecraft into two parts used in this work allows determination of the compression factor of an active frame depending not only on the statistics of activity of channels in the telemetry frame, but also on the method of introduction of the additional address and time information to each frame.

Khodarev, Y. K.↗

Technology Directions for the 21st Century

Data compression is an important tool for reducing the bandwidth of communications systems, and thus for reducing the size, weight, and power of spacecraft systems. For data requiring lossless transmissions, including most science data from spacecraft sensors, small compression factors of two to three may be expected. Little improvement can be expected over time. For data that is suitable for lossy compression, such as video data streams, much higher compression factors can be expected, such as 100 or more. More progress can be expected in this branch of the field, since there is more hidden redundancy and many more ways to exploit that redundancy.

Crimi, Giles↗

Numerical Modeling of Unsteady Thermofluid Dynamics in Cryogenic Systems

A finite volume based network analysis procedure has been applied to model unsteady flow without and with heat transfer. Liquid has been modeled as compressible fluid where the compressibility factor is computed from the equation of state for a real fluid. The modeling approach recognizes that the pressure oscillation is linked with the variation of the compressibility factor; therefore, the speed of sound does not explicitly appear in the governing equations. The numerical results of chilldown process also suggest that the flow and heat transfer are strongly coupled. This is evident by observing that the mass flow rate during 90-second chilldown process increases by factor of ten.

Majumdar, Alok↗

A packet data compressor

We are in the preliminary stages of creating an operational system for losslessly compressing packet data streams. The end goal is to reduce costs. Real world constraints include transmission in the presence of error, tradeoffs between the costs of compression and the costs of transmission and storage, and imperfect knowledge of the data streams to be transmitted. The overall method is to bring together packets of similar type, split the data into bit fields, and test a large number of compression algorithms. Preliminary results are very encouraging, typically offering compression factors substantially higher than those obtained with simpler generic byte stream compressors, such as Unix Compress and HA 0.98.

Grunes, Mitchell R.↗

Efficient transfer of images over networks

Effective remote observing requires sending large images over long distances. The usual approach to the transfer problem is to require high bandwidth transmission links, which are expensive to install and operate. An alternative approach is to use existing low-bandwidth connections, such as phone lines or the Internet, in a highly efficient manner by compressing the images. The combined use of existing low-cost infrastructure and standard networking software means that remote observing can be made practical even for small observatories with limited network resources. The authors have implemented such a scheme based on the H-transform compression method developed for astronomical images, which are often resistant to compression because they are noisy. The H-transform can be used for either lossy or lossless compression, and compression factors of at least 10 can be achieved with no noticeable losses in the astrometric or photometric properties of the compressed images. The H-transform allows us to organize the information in an image so that the 'useful' information can be sent first, followed by the noise, which makes up the bulk of the transmission. The receiver can invert a partially received set of H-coefficients, creating an image that improves with time. The H-transform is particularly well-suited to this style of incremental reconstruction, because the spatially localized nature of the basis functions of the H-transorm prevents the appearance of artifacts such as ringing around point sources and edges. The authors' implementation uses the WIYN Telescope Control System's TCP-based communications protocol. An 800x800 16-bit astronomical image was sent over a 2400 baud connection, which would normally take about 71 minutes; after only 60 seconds, the partially received H-transform produced an image that did not differ appreciably from the original. This poster presents a quantification of the efficiencies, as well as examples of images reconstructed from partial data.

Percival, J. W.↗

High pressure real gas effects for helium and nitrogen

Critical flow factor is calculated that permits the isentropic mass-flow rate of the gases through critical flow nozzles to be calculated from plenum conditions. Results include nozzle throat velocity, compressibility factor, entropy, enthalpy, specific heat, and ratios of throat to plenum pressure, density, and temperature.

Johnson, R. C.↗

Tables of critical-flow functions and thermodynamic properties for methane and computational procedures for both methane and natural gas

Procedures for calculating the mass flow rate of methane and natural gas through nozzles are given, along with the FORTRAN 4 subroutines used to make these calculations. Three sets of independent variables are permitted in these routines. In addition to the plenum pressure and temperature, the third independent variable is either nozzle exit pressure, Mach number, or temperature. A critical-flow factor that becomes a convenient means for determining the mass flow rate of methane through critical-flow nozzles is tabulated. Other tables are included for nozzle throat velocity and critical pressure, density, and temperature ratios, along with some thermodynamic properties of methane, including compressibility factor, enthalpy, entropy, specific heat, specific-heat ratio, and speed of sound. These tabulations cover a temperature range from 120 to 600 K and pressures to 3 million N/sq m.

Johnson, R. C.↗

Thermophysical properties of sodium

Assessment is given of physical and thermodynamic properties of sodium. FORTRAN subroutine computes enthalphy and entropy of sodium in given state, and composition, molecular weight, volume, and compressibility factor of corresponding vapor. Tabular results for saturated liquid and vapor are presented for a 500-2500 degree F range.

Golden, G. H.↗

A priori estimate of the quality of a data compression system based on statistical characteristics of the sensors used

Knowledge of the composition and certain statistical characteristics of the output signals of the scientific instruments on board a space vehicle allows determination of possible signal processing algorithms in the system and to evaluate the prospects for utilization of data reduction. A method is presented to estimate the compression factor of an on-board data collection and processing system with known mean activities of the sensors used and unknown mutual correlation of their output signals.

Khodarev, Y. K.↗

ITOS VHRR on-board data compression study

Data compression methods for ITOS VHRR data were studied for a tape recorder record-and playback application. A playback period of 9 minutes was assumed with a nominal 18 minute record period for a 2-to-1 compression ratio. Both analog and digital methods were considered with the conclusion that digital methods should be used. Two system designs were prepared. One is a PCM system and the other is an entropy-coded predictive-quantization, sometimes called entropy-coded DPCM or just DPCM, system. Both systems use data management principles to transmit only the necessary data. Both systems use a medium capacity standard tape recorder from specifications provided by the technical officer. The 10 to the 9th power bit capacity of the recorder is the basic limitation on the compression ratio. Both systems achieve the minimum desired 2 to 1 compression ratio. A slower playback rate can be used with the DPCM system due to a higher compression factor for better link performance at a given CNR in terms of bandwidth utilization and error rate. The report is divided into two parts. The first part summarizes the theoretical conclusions of the second part and presents the system diagrams. The second part is a detailed analysis based upon an empirically derived random process model arrived at from specifications and measured data provided by the technical officer.

Gray, R. M.↗

Normal- and oblique-shock flow parameters in equilibrium air including attached-shock solutions for surfaces at angles of attack, sweep, and dihedral

Normal- and oblique-shock flow parameters for air in thermochemical equilibrium are tabulated as a function of shock angle for altitudes ranging from 15.24 km to 91.44 km in increments of 7.62 km at selected hypersonic speeds. Post-shock parameters tabulated include flow-deflection angle, velocity, Mach number, compressibility factor, isentropic exponent, viscosity, Reynolds number, entropy difference, and static pressure, temperature, density, and enthalpy ratios across the shock. A procedure is presented for obtaining oblique-shock flow properties in equilibrium air on surfaces at various angles of attack, sweep, and dihedral by use of the two-dimensional tabulations. Plots of the flow parameters against flow-deflection angle are presented at altitudes of 30.48, 60.96, and 91.44 km for various stream velocities.

Hunt, J. L.↗

Commonality Study of the Pressure-Volume-Temperature Based Propellant Gaging Software Modules for the Auxiliary Power Unit, Reaction Control System, and Orbital Maneuvering System

Computer storage requirements can be reduced if areas of commonality exist in two or more programs placed in the same computer and identical code can be used by more than one program. The pressure-volume-temperature (P-V-T) relationship for the propellant tank pressurant agent is utilized as the basis for either a primary of a backup propellant gaging program for the auxiliary power unit (APU), the reaction control system (RCS), and the orbital maneuvering system (OMS). These three propellant gaging programs were investigated. It was revealed that a very limited degree of software commonality exits among them. An examination of this common software indicated that only the computation of the helium compressibility factor in an external function subprogram accessible to both the RCS and OMS propellant gaging programs appears to offer a savings in computer storage requirements.

Duhon, D. D.↗

Noiseless coding for the Gamma Ray spectrometer

The payload of several future unmanned space missions will include a sophisticated gamma ray spectrometer. Severely constrained data rates during certain portions of these missions could limit the possible science return from this instrument. This report investigates the application of universal noiseless coding techniques to represent gamma ray spectrometer data more efficiently without any loss in data integrity. Performance results demonstrate compression factors from 2.5:1 to 20:1 in comparison to a standard representation. Feasibility was also demonstrated by implementing a microprocessor breadboard coder/decoder using an Intel 8086 processor.

Rice, R.↗