Search NASA⌕ Search

SEARCH · Search NASA

Results for “compton scattering, sodium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Quantum Monte Carlo Endstation for Petascale Computing

The major achievements enabled by QMC Endstation grant include * Performance improvement on clusters of x86 multi-core systems, especially on Cray XT systems * New and improved methods for the wavefunction optimizations * New forms of trial wavefunctions * Implementation of the full application on NVIDIA GPUs using CUDA The scaling studies of QMCPACK on large-scale systems show excellent parallel efficiency up to 216K cores on Jaguarpf (Cray XT5). The GPU implementation shows speedups of 10-15x over the CPU implementation on older generation of x86. We have implemented hybrid OpenMP/MPI scheme in QMC to take advantage of multi-core shared memory processors of petascale systems. Our hybrid scheme has several advantages over the standard MPI-only scheme. * Memory optimized: large read-only data to store one-body orbitals and other shared properties to represent the trial wave function and many-body Hamiltonian can be shared among threads, which reduces the memory footprint of a large-scale problem. * Cache optimized: the data associated with an active Walker are in cache during the compute-intensive drift-diffusion process and the operations on an Walker are optimized for cache reuse. Thread-local objects are used to ensure the data affinity to a thread. * Load balanced: Walkers in an ensemble are evenly distributed among threads and MPI tasks. The two-level parallelism reduces the population imbalance among MPI tasks and reduces the number of point-to-point communications of large messages (serialized objects) for the Walker exchange. * Communication optimized: the communication overhead, especially for the collective operations necessary to determine ET and measure the properties of an ensemble, is significantly lowered by using less MPI tasks. The multiple forms of parallelism afforded by QMC algorithms make them ideal candidates for acceleration in the many-core paradigm. We presented the results of our effort to port the QMCPACK simulation code to the NVIDIA CUDA GPU platform. We restructured the CPU algorithms to express additional parallelism, minimize GPU-CPU communication, and efficiently utilize the GPU memory hierarchy. Using mixed precision on GT200 GPUs and MPI for intercommunication and load balancing, we observe typical full-application speedups of approximately 10x to 15x relative to quad-core Xeon CPUs alone, while reproducing the double-precision CPU results within statistical error. We developed an all-electron quantum Monte Carlo (QMC) method for solids that does not rely on pseudopotentials, and used it to construct a primary ultra-high-pressure calibration based on the equation of state of cubic boron nitride. We computed the static contribution to the free energy with the QMC method and obtained the phonon contribution from density functional theory, yielding a high-accuracy calibration up to 900 GPa usable directly in experiment. We computed the anharmonic Raman frequency shift with QMC simulations as a function of pressure and temperature, allowing optical pressure calibration. In contrast to present experimental approaches, small systematic errors in the theoretical EOS do not increase with pressure, and no extrapolation is needed. This all-electron method is applicable to first-row solids, providing a new reference for ab initio calculations of solids and benchmarks for pseudopotential accuracy. We compared experimental and theoretical results on the momentum distribution and the quasiparticle renormalization factor in sodium. From an x-ray Compton-profile measurement of the valence-electron momentum density, we derived its discontinuity at the Fermi wavevector finding an accurate measure of the renormalization factor that we compared with quantum-Monte-Carlo and G0W0 calculations performed both on crystalline sodium and on the homogeneous electron gas. Our calculated results are in good agreement with the experiment. We have been studying the heat of formation for various Kubas complexes of molecular hydrogen on Ti(1,2)ethylene-nH2 using Diffusion Monte Carlo. This work has been started and is ongoing. We are studying systems involving 1 and 2 Ti bonding sites with up to 10 hydrogen molecules in numerous configurations. This work will establish a benchmark that will test the accuracy of density functional calculations and establish the feasibility of our methods for similar systems.

97 MATHEMATICS AND COMPUTING↗

Neutron Compton scattering as a molecular characterization technique: A study on NaHF{sub 2}

Inelastic neutron scattering experiments were performed at intermediate and high momentum transfers, up to 85-90 A ring {sup -1}, to study the proton momentum distribution in polycrystalline sodium hydrogen fluoride (NaHF{sub 2}) at low temperature (below 5 K). The H mean kinetic energy was extracted and compared to the results from hydrogen-projected density of phonon states derived from intermediate momentum transfer inelastic neutron scattering and lattice dynamics simulations. A reasonable agreement between the two figures was found. In addition, relevant aspects of high momentum transfer neutron scattering from NaHF{sub 2} were explored in detail, ranging from an alternative evaluation of final state effects to the role played by the instrumental resolution and to the possibility to reconstruct the potential felt by a proton from its momentum distribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of Multihole Collimator Gamma Camera Simulation Modeled Using MCNP5

This paper describes the characteristics of the multihole collimator gamma camera that is simulated using the combination of the Monte Carlo N-Particles Code (MCNP) version 5 and in-house software. The model is constructed based on the GCA-7100A Toshiba Gamma Camera at the Royal Surrey County Hospital, Guildford, Surrey, UK. The characteristics are analyzed based on the spatial resolution of the images detected by the Sodium Iodide (NaI) detector. The result is recorded in a list-mode file referred to as a PTRAC file within MCNP5. All pertinent nuclear reaction mechanisms, such as Compton and Rayleigh scattering and photoelectric absorption are undertaken by MCNP5 for all materials encountered by each photon. The experiments were conducted on Tl-201, Co-57, Tc-99 m and Cr-51 radio nuclides. The comparison of full width half maximum value of each datasets obtained from experimental work, simulation and literature are also reported in this paper. The relationship of the simulated data is in agreement with the experimental results and data obtained in the literature. A careful inspection at each of the data points of the spatial resolution of Tc-99 m shows a slight discrepancy between these sets. However, the difference is very insignificant, i.e. less than 3 mm only, which corresponds to a size of less than 1 pixel only (of the segmented detector)00.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An x ray scatter approach for non-destructive chemical analysis of low atomic numbered elements

A non-destructive x-ray scatter (XRS) approach has been developed, along with a rapid atomic scatter algorithm for the detection and analysis of low atomic-numbered elements in solids, powders, and liquids. The present method of energy dispersive x-ray fluorescence spectroscopy (EDXRF) makes the analysis of light elements (i.e., less than sodium; less than 11) extremely difficult. Detection and measurement become progressively worse as atomic numbers become smaller, due to a competing process called 'Auger Emission', which reduces fluorescent intensity, coupled with the high mass absorption coefficients exhibited by low energy x-rays, the detection and determination of low atomic-numbered elements by x-ray spectrometry is limited. However, an indirect approach based on the intensity ratio of Compton and Rayleigh scattered has been used to define light element components in alloys, plastics and other materials. This XRS technique provides qualitative and quantitative information about the overall constituents of a variety of samples.

Ross, H. Richard↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Case Study Correlating Innovative Gamma Ray Scanning Detection Systems Data to Surface Soil Gamma Spectrometry Results - 13580

HydroGeoLogic (HGL), Inc. completed a United States Environmental Protection Agency (USEPA) study to characterize radiological contamination at a site near Canoga Park, California. The characterized area contained 470 acres including the site of a prototype commercial nuclear reactor and other nuclear design, testing, and support operations from the 1950's until 1988 [1]. The site history included radiological releases during operation followed by D and D activities. The characterization was conducted under an accelerated schedule and the results will support the project remediation. The project has a rigorous cleanup to background agenda and does not allow for comparison to risk-based guidelines. To target soil sample locations, multiple lines of evidence were evaluated including a gamma radiation survey, geophysical surveys, historical site assessment, aerial photographs, and former worker interviews. Due to the time since production and decay, the primary gamma emitting radionuclide remaining is cesium-137 (Cs-137). The gamma ray survey covered diverse, rugged terrain using custom designed sodium iodide thallium-activated (NaI(Tl)) scintillation detection systems. The survey goals included attaining 100% ground surface coverage and detecting gamma radiation as sensitively as possible. The effectiveness of innovative gamma ray detection systems was tested by correlating field Cs-137 static count ratios to Cs-137 laboratory gamma spectrometry results. As a case study, the area encompassing the former location of the first nuclear power station in the U. S. was scanned, and second by second global positioning system (GPS)-linked gamma spectral data were evaluated by examining total count rate and nuclide-specific regions of interest. To compensate for Compton scattering from higher energy naturally occurring radionuclides (U-238, Th-232 and their progeny, and K-40), count rate ratios of anthropogenic nuclide-specific regions of interest to the total count rate were calculated. From the scanning data, locations with observed Cs-137 ratios exceeding six standard deviations above the mean ratio were mapped in high resolution [2]. Field teams returned to those locations to collect static count measurements using the same detection systems. Soil surface samples were collected at 30 locations and analyzed for Cs-137. An exponential correlation was identified between Cs-137 concentrations in surface soil and field-scanned Cs-137 ratios. The data indicate field minimum detectable concentration (MDC) of Cs-137 at 0.02 Bq/g (0.5 pCi/g) or lower depending on contaminant distribution in soil. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Experiment for testing special relativity theory

An experiment aimed at testing special relativity via a comparison of the velocity of a nonmatter particle (annihilation photon) with the velocity of the matter particle (Compton electron) produced by the second annihilation photon from the decay {sup 22}Na ({beta}+){sup 22}Ne is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of sample thickness on 511 keV single Compton-scattered gamma rays

Gamma backscattering experiments were performed on metal foils varying some geometric parameters of the assembly. A collimated beam from a {sup 22}Na source impinges on aluminum sheets of dimensions 33.3×20.4×1.0 cm{sup 3} and iron sheets of (33.2×20.4×0.2) cm{sup 3}. The backscattered photons are detected by a 3″×3″ CsI scintillator detector placed at 90° to the incident beam. The experimental results show that thickness of metalic samples can be determined with a very small uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-189: A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification

Purpose: To test two new techniques, the distance-of-closest approach (DCA) and Compton line (CL) filters, developed as a means of improving the spatial resolution of Compton camera (CC) imaging. Methods: Gammas emitted from {sup 22}Na, {sup 137}Cs, and {sup 60}Co point sources were measured with a prototype 3-stage CC. The energy deposited and position of each interaction in each stage were recorded and used to calculate a “cone-of-origin” for each gamma that scattered twice in the CC. A DCA filter was developed which finds the shortest distance from the gamma’s cone-of-origin surface to the location of the gamma source. The DCA filter was applied to the data to determine the initial energy of the gamma and to remove “bad” interactions that only contribute noise to the image. Additionally, a CL filter, which removes gamma events that do not follow the theoretical predictions of the Compton scatter equation, was used to further remove “bad” interactions from the measured data. Then images were reconstructed with raw, unfiltered data, DCA filtered data, and DCA+CL filtered data and the achievable image resolution of each dataset was compared. Results: Spatial resolutions of ∼2 mm, and better than 2 mm, were achievable with the DCA and DCA+CL filtered data, respectively, compared to > 5 mm for the raw, unfiltered data. Conclusion: In many special cases in medical imaging where information about the source position may be known, such as proton radiotherapy range verification, the application of the DCA and CL filters can result in considerable improvements in the achievable spatial resolutions of Compton imaging.

60 APPLIED LIFE SCIENCES↗

COMPTON DEGRADATION OF GAMMA-RAY LINE EMISSION FROM RADIOACTIVE ISOTOPES IN THE CLASSICAL NOVA V2491 CYGNI

To account for the non-thermal emission from the classical nova V2491 Cygni, we perform a series of numerical calculations of radiative transfer of {gamma}-ray photons from the radioactive isotope {sup 22}Na in the matter ejected from a white dwarf. Using a simple wind model for the dynamical evolution of the ejecta and a Monte Carlo code, we calculate radiative transfer of the {gamma}-ray photons in the ejecta. Repeated scattering of the {gamma}-ray photons by electrons in the ejecta, i.e., Compton degradation, results in an extremely flat spectrum in the hard X-ray range, which successfully reproduces the observed spectrum of the X-ray emission from V2491 Cygni. The amount of the isotope {sup 22}Na synthesized in the ejecta is required to be 3 x 10{sup -5} M {sub sun} to account for the flux of the hard X-ray emission. Our model indicates that the ejecta become transparent to the {gamma}-ray photons within several tens days. Using the results, we briefly discuss the detectability of the {gamma}-ray line emission by the INTEGRAL gamma-ray observatory and the Fermi Gamma-ray Space Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗