Search NASA⌕ Search

SEARCH · Search NASA

Results for “computation time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real time computations of cryogenic He properties

The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC and provide protons to the remainder of the existing accelerator complex. The new LINAC consists of a warm front end, 23 superconducting RF cryomodules, and a beam transfer line to the existing complex. The cryomodules (CMs) are to be tested at Fermilab's CryoModule Test Facility (CMTF).An important measurement in cryogenic testing is the heat load of each CM. Traditionally, at Fermilab, these measurements were made collecting archived data offline and analyzing it. The new control system for PIP-II is being developed with the EPICS (Experimental Physics and Industrial Control System) framework, which allows us to compute the heat load in real time using the HePak library.We are exploring other $He$ properties, such as flow, where flow meters are not available, which can also be calculated in real time and fed back to the cryogenics engineers.This paper details the real time heat load calculation and $He$ flow software developed for CM testing at CMTF, as well as the first results from the prototype HB650 CM. Future plans for 2-phase $LHe$ flow will also be outlined.

Hanlet, Pierrick [Fermilab]↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Comparing computational times for simulations when using PBPK model template and stand-alone implementations of PBPK models

Introduction We previously developed a PBPK model template that consists of a single model “superstructure” with equations and logic found in many physiologically based pharmacokinetic (PBPK) models. Using the template, one can implement PBPK models with different combinations of structures and features. Methods To identify factors that influence computational time required for PBPK model simulations, we conducted timing experiments using various implementations of PBPK models for dichloromethane and chloroform, including template and stand-alone implementations, and simulating four different exposure scenarios. For each experiment, we measured the required computational time and evaluated the impacts of including various model features (e.g., number of output variables calculated) and incorporating various design choices (e.g., different methods for estimating blood concentrations). Results We observed that model implementations that treat body weight and dependent quantities as constant (fixed) parameters can result in a 30% time savings compared with options that treat body weight and dependent quantities as time-varying. We also observed that decreasing the number of state variables by 36% in our PBPK model template led to a decrease of 20–35% in computational time. Other factors, such as the number of output variables, the method for implementing conditional statements, and the method for estimating blood concentrations, did not have large impacts on simulation time. In general, simulations with PBPK model template implementations of models required more time than simulations with stand-alone implementations, but the flexibility and (human) time savings in preparing and reviewing a model implemented using the PBPK model template may justify the increases in computational time requirements. Conclusion Our findings concerning how PBPK model design and implementation decisions impact computational speed can benefit anyone seeking to develop, improve, or apply a PBPK model, with or without the PBPK model template.

Bernstein, Amanda S.↗

SU-E-T-121: Analyzing the Broadening Effect On the Bragg Peak Due to Heterogeneous Geometries and Implementing User-Routines in the Monte-Carlo Code FLUKA in Order to Reduce Computation Time

Purpose: Aim of this study was to analyze the modulating, broadening effect on the Bragg Peak due to heterogeneous geometries like multi-wire chambers in the beam path of a particle therapy beam line. The effect was described by a mathematical model which was implemented in the Monte-Carlo code FLUKA via user-routines, in order to reduce the computation time for the simulations. Methods: The depth dose curve of 80 MeV/u C12-ions in a water phantom was calculated using the Monte-Carlo code FLUKA (reference curve). The modulating effect on this dose distribution behind eleven mesh-like foils (periodicity ∼80 microns) occurring in a typical set of multi-wire and dose chambers was mathematically described by optimizing a normal distribution so that the reverence curve convoluted with this distribution equals the modulated dose curve. This distribution describes a displacement in water and was transferred in a probability distribution of the thickness of the eleven foils using the water equivalent thickness of the foil’s material. From this distribution the distribution of the thickness of one foil was determined inversely. In FLUKA the heterogeneous foils were replaced by homogeneous foils and a user-routine was programmed that varies the thickness of the homogeneous foils for each simulated particle using this distribution. Results: Using the mathematical model and user-routine in FLUKA the broadening effect could be reproduced exactly when replacing the heterogeneous foils by homogeneous ones. The computation time was reduced by 90 percent. Conclusion: In this study the broadening effect on the Bragg Peak due to heterogeneous structures was analyzed, described by a mathematical model and implemented in FLUKA via user-routines. Applying these routines the computing time was reduced by 90 percent. The developed tool can be used for any heterogeneous structure in the dimensions of microns to millimeters, in principle even for organic materials like lung tissue.

60 APPLIED LIFE SCIENCES↗

Region-oriented CT image representation for reducing computing time of Monte Carlo simulations

Purpose. We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. Material and methods. The proposed approach, based on an implicit volume representation named segmented volume, coupled with an adapted segmentation procedure and a distance map, allows us to minimize the number of boundary crossings, which slows down simulation. The method was implemented with the GEANT4 toolkit and compared to four other methods: One box per voxel, parameterized volumes, octree-based volumes, and nested parameterized volumes. For each representation, we compared dose distribution, time, and memory consumption. Results. The proposed method allows us to decrease computational time by up to a factor of 15, while keeping memory consumption low, and without any modification of the transportation engine. Speeding up is related to the geometry complexity and the number of different materials used. We obtained an optimal number of steps with removal of all unnecessary steps between adjacent voxels sharing a similar material. However, the cost of each step is increased. When the number of steps cannot be decreased enough, due for example, to the large number of material boundaries, such a method is not considered suitable. Conclusion. This feasibility study shows that optimizing the representation of an image in memory potentially increases computing efficiency. We used the GEANT4 toolkit, but we could potentially use other Monte Carlo simulation codes. The method introduces a tradeoff between speed and geometry accuracy, allowing computational time gain. However, simulations with GEANT4 remain slow and further work is needed to speed up the procedure while preserving the desired accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Challenges in reducing the computational time of QSTS simulations for distribution system analysis.

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modelling and impact analysis. Unlike conventional scenario - based studies , quasi - static time - series (QSTS) simulation s can realistically model time - dependent voltage controllers and the diversity of potential impacts that can occur at different times of year . However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1 - second resolution is often required , which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled . This computational burden is a clear l imitation to the adoption of QSTS simulation s in interconnection studies and for determining optimal control solutions for utility operations . Our ongoing research to improve the speed of QSTS simulation has revealed many unique aspects of distribution system modelling and sequential power flow analysis that make fast QSTS a very difficult problem to solve. In this report , the most relevant challenges in reducing the computational time of QSTS simulations are presented: number of power flows to solve, circuit complexity, time dependence between time steps, multiple valid power flow solutions, controllable element interactions, and extensive accurate simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NNSA?s Computing Strategy, Acquisition Plan, and Basis for Computing Time Allocation

This report is in response to the Omnibus Appropriations Act, 2009 (H.R. 1105; Public Law 111-8) in its funding of the National Nuclear Security Administration's (NNSA) Advanced Simulation and Computing (ASC) Program. This bill called for a report on ASC's plans for computing and platform acquisition strategy in support of stockpile stewardship. Computer simulation is essential to the stewardship of the nation's nuclear stockpile. Annual certification of the country's stockpile systems, Significant Finding Investigations (SFIs), and execution of Life Extension Programs (LEPs) are dependent on simulations employing the advanced ASC tools developed over the past decade plus; indeed, without these tools, certification would not be possible without a return to nuclear testing. ASC is an integrated program involving investments in computer hardware (platforms and computing centers), software environments, integrated design codes and physical models for these codes, and validation methodologies. The significant progress ASC has made in the past derives from its focus on mission and from its strategy of balancing support across the key investment areas necessary for success. All these investment areas must be sustained for ASC to adequately support current stockpile stewardship mission needs and to meet ever more difficult challenges as the weapons continue to age or undergo refurbishment. The appropriations bill called for this report to address three specific issues, which are responded to briefly here but are expanded upon in the subsequent document: (1) Identify how computing capability at each of the labs will specifically contribute to stockpile stewardship goals, and on what basis computing time will be allocated to achieve the goal of a balanced program among the labs. (2) Explain the NNSA's acquisition strategy for capacity and capability of machines at each of the labs and how it will fit within the existing budget constraints. (3) Identify the technical challenges facing the program and a strategy to resolve them.

36 MATERIALS SCIENCE↗

Study on efficiency of time computation in x-ray imaging simulation base on Monte Carlo algorithm using graphics processing unit

Monte Carlo (MC) is one of the powerful techniques for simulation in x-ray imaging. MC method can simulate the radiation transport within matter with high accuracy and provides a natural way to simulate radiation transport in complex systems. One of the codes based on MC algorithm that are widely used for radiographic images simulation is MC-GPU, a codes developed by Andrea Basal. This study was aimed to investigate the time computation of x-ray imaging simulation in GPU (Graphics Processing Unit) compared to a standard CPU (Central Processing Unit). Furthermore, the effect of physical parameters to the quality of radiographic images and the comparison of image quality resulted from simulation in the GPU and CPU are evaluated in this paper. The simulations were run in CPU which was simulated in serial condition, and in two GPU with 384 cores and 2304 cores. In simulation using GPU, each cores calculates one photon, so, a large number of photon were calculated simultaneously. Results show that the time simulations on GPU were significantly accelerated compared to CPU. The simulations on the 2304 core of GPU were performed about 64 -114 times faster than on CPU, while the simulation on the 384 core of GPU were performed about 20 – 31 times faster than in a single core of CPU. Another result shows that optimum quality of images from the simulation was gained at the history start from 10{sup 8} and the energy from 60 Kev to 90 Kev. Analyzed by statistical approach, the quality of GPU and CPU images are relatively the same.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bound on quantum computation time: Quantum error correction in a critical environment

We obtain an upper bound on the time available for quantum computation for a given quantum computer and decohering environment with quantum error correction implemented. First, we derive an explicit quantum evolution operator for the logical qubits and show that it has the same form as that for the physical qubits but with a reduced coupling strength to the environment. Using this evolution operator, we find the trace distance between the real and ideal states of the logical qubits in two cases. For a super-Ohmic bath, the trace distance saturates, while for Ohmic or sub-Ohmic baths, there is a finite time before the trace distance exceeds a value set by the user.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-driving thin film laboratory: autonomous epitaxial atomic-layer synthesis via real-time computer vision analysis of electron diffraction

Emerging materials science platforms with the ability to make autonomous decisions on the fly are fundamentally changing the outlook and protocols for materials optimization and discovery. Because AI-driven self-navigating schemes can effectively reduce the total number of iterations needed to arrive at the "answer" (i.e. the best stochiometric composition for a desired physical property, optimum materials processing parameters, etc.) by significant margins, they have the potential to revolutionize materials and chemical manufacturing processes at large in research laboratory settings as well as in industrial plants. Here, we demonstrate a successful implementation of real-time closed-loop autonomous navigation of a multi-dimensional materials synthesis parameter space for fabricating phase-pure epitaxial films of a metastable phase of a functional oxide in a combinatorial pulsed laser deposition chamber. Sequential epitaxial growth iterations in search of the optimized recipe to stabilize the desired crystal phase were performed using frame-by-frame quantitative computer vision analysis of reflection high-energy electron diffraction (RHEED) images of the unit-cell level film being deposited. The autonomous scheme regularly resulted in > 30-fold reduction in the number of required experiments compared to a comprehensive mapping of the parameter space. The real-time workflow developed here can be readily extended to a variety of thin film synthesis platforms opening the door for self-driving atomic-level materials design as well as autonomous optimization of semiconductor manufacturing.

36 MATERIALS SCIENCE↗

Towards a real-time computation of timelike hadronic vacuum polarization and light-by-light scattering: Schwinger Model tests

Hadronic vacuum polarization (HVP) and light-by-light scattering (HLBL) are crucial for evaluating the Standard Model predictions concerning the muon’s anomalous magnetic moment. However, direct first-principle lattice gauge theory-based calculations of these observables in the timelike region remain challenging. Discrepancies persist between lattice quantum chromodynamics (QCD) calculations in the spacelike region and dispersive approaches relying on experimental data parametrization from the timelike region. Here, we introduce a methodology employing 1+1-dimensional quantum electrodynamics (QED), i.e. the Schwinger Model, to investigate the HVP and HLBL. To that end, we use both tensor network techniques, specifically matrix product states, and classical emulators of digital quantum computers. Demonstrating feasibility in a simplified model, our approach sets the stage for future endeavors leveraging digital quantum computers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DECREASING COMPUTING TIME WITH SYMPLECTIC CORRECTORS IN ADAPTIVE TIMESTEPPING ROUTINES

It has previously been shown that varying the numerical timestep during a symplectic orbital integration leads to a random walk in energy and angular momentum, destroying the phase space-conserving property of symplectic integrators. Here we show that when altering the timestep symplectic correctors can be used to reduce this error to a negligible level. Furthermore, these correctors can also be employed to avoid a large error introduction when changing the Hamiltonian's partitioning. We have constructed a numerical integrator using this technique that is nearly as accurate as widely used fixed-step routines. In addition, our algorithm is drastically faster for integrations of highly eccentricitic, large semimajor axis orbits, such as those found in the Oort Cloud.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗