Search NASA⌕ Search

SEARCH · Search NASA

Results for “computed tomography (CT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Tools for pressure core sub-coring and pore-scale micro-CT (computed tomography) scans

Abstract. The pore habits of gas hydrate in natural sediment matrices provide essential clues for understanding physical (mechanical, thermal, hydraulic, and electrical) properties of hydrate-bearing sediments, yet there are no tools that can directly visualize the pore habits of natural gas hydrate other than indirect interpretation based on core-scale or field-scale observations. A significant challenge is to obtain a mini-core from pressure cores retrieved from natural reservoirs for high-resolution micro-CT (computed tomography) scans while maintaining pressure and temperature conditions required for stability of gas hydrate during all operational steps including manipulation, cutting, transferring, sub-coring and CT scanning. We present a new set of tools for pore-scale micro-CT imaging of natural hydrate-bearing sediments while maintaining pressure and temperature control. The tests with laboratory-prepared cores and pressure cores successfully demonstrate the capability of this set of tools to subsample a mini-core from pressure cores, transfer the mini-core to an X-ray transparent core holder, and conduct micro-CT scans. Successfully obtained CT images prove the functionality of this set of tools.

Seol, Yongkoo↗

Imaging APO-BMI with Micro X-ray Computed Tomography (CT)

APO-BMI is a high-strength, high-temperature, and low-density foam comprised of 1,2-bis(2-aminophenylthio) ethane (APO-Link, formerly Apocure-601) and 4,4’-bismaleimidodiphenylmethane (BMI) that is used structural applications within the aerospace and weapons manufacturing sectors. APO-link is the diamine reagent used to synthesize BMI, a thermosetting resin. This resin can remain in a molten, flowing state for an extended period of time before crosslinking, allowing addition of glass or carbon microballoons to form its final structure. A portion of the current project was to observe the thermal effects on the structural integrity of the foam associated with exposure to an ion beam. Features within the foam were imaged using micro X-ray computed tomography (CT). The resulting imaging provided evidence that microballoon structure remained mostly intact at the points of failure, indicating that the failure of the material was occurring in the binder material.

36 MATERIALS SCIENCE↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Computed Tomography (CT) Analysis of 3D Printed Lattice Structures

LATTICE structures are increasingly used in product design across different industries, including the Department of Energy (DOE), due to their high strength and lightweight properties. These structures possess qualities such as high stiffness, energy absorption, large surface area, and structural support. To ensure lattice structures' quality and symmetry, it is crucial to have defect-free structures. However, in some cases, traditional non-destructive evaluation methods may not be practical due to encasing lattice structures in material. To analyze the lattice structures' quality, this project will employ CT imaging to gain access to the encased structures and perform a detailed analysis of each section. Three 3D printed complex lattice cubes were created, with two exposed and one encased in material, for this project. The CT X-ray cabinet will be used to scan all three cubes, and the data collected will be reconstructed and evaluated using complex interpretation software. This analysis will allow for a detailed examination of the structure's porosity, inclusions, cracks, wall thickness, and symmetry in each section.

36 MATERIALS SCIENCE↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

Wettability Alteration with Weak Acid-Assisted Surfactant Flood

Oil-wetness and heterogeneity are two key reasons for low oil recovery by waterflooding in carbonate reservoirs. Surfactants have been effective in altering the oil-wet matrix to a more water-wet condition and initiating spontaneous imbibition. Because it takes time for the surfactant to alter wettability, oil recovery from the tight matrix is slow and sometimes not economically feasible. Acids have the potential of dissolving minerals, which may alter wettability. In this study, the enhanced oil recovery (EOR) performance of an acid-assisted surfactant solution, a novel technique, was evaluated for low-temperature applications. A set of acids and their acetates were tested. Bulk rock-acid reaction, wettability alteration (WA) tests, and spontaneous imbibition measurements were conducted at reservoir temperature (35°C) to identify effective candidates. Coreflood tests were then performed to evaluate the selected acid-surfactant formulations. Before and after a coreflood test, the core was scanned using micro-computed tomography (CT) to investigate pore structure alteration. Bulk reaction measurements showed that weak acids, especially acetic acid (AA), have the desired low reaction rates at 35°C. WA tests showed that AA can remove the crude oil off the rock surface and alter wettability through mineral dissolution. The surfactant can reduce contact angles from 160° to 58°; adding acid into the surfactant can further reduce it to 52°. Spontaneous imbibition experiments showed the synergy between the acid and the surfactant; the AA-surfactant solution had the highest oil recovery (62.6%) among acid-surfactant formulations. The acid improves the WA efficiency by the surfactant through surface mineral dissolution and lower ζ-potential. The imbibition transports the acid-surfactant solutions into the matrix, which minimizes face dissolution. Coreflood tests show that the AA-surfactant flood can increase the oil recovery rate and recover about 8% more oil compared to the surfactant flood. Micro-CT showed that a few mineral particles were transported along the core and partially plugged pore throats, which reduced permeability and diverted flow leading to improved oil recovery. Here, the transport of the acid in reservoirs and the potential plugging issues have to be carefully evaluated in future studies.

58 GEOSCIENCES↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

CT Scans of Cores Metadata, Utqiagvik (Barrow), Alaska, 2015

Individual ice cores were collected from Barrow Environmental Observatory in Barrow, Alaska, throughout 2013 and 2014. Cores were drilled along different transects to sample polygonal features (i.e. the trough, center and rim of high, transitional and low center polygons). Most cores were drilled around 1 meter in depth and a few deep cores were drilled around 3 meters in depth. Three-dimensional images of the frozen cores were constructed using a medical X-ray computed tomography (CT) scanner. TIFF files can be uploaded to ImageJ (an open-source imaging software) to examine soil structure and soil densities within each core.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Assessment of Dynamic Fracture in Ultra-High Performance Concrete Using Synchrotron X-ray Source

Ultra-high-performance concretes (UHPCs) retain higher ultimate (compressive) strengths and greater durability relative to traditional concrete materials. As a result, they are enabling construction materials for blast resistant structures, where a higher capacity for energy absorption is required. In past investigations, the strength of UHPCs was shown to retain a dependency on strain rate. Still, the failure mechanisms which govern this rate dependency have yet to be completely elucidated. In the current study, the dynamic fracture behavior of Cor-tuf UHPC was assessed, in-situ, using a Synchrotron X-ray source in phase contrast imaging (PCI) mode. Prior to testing, the material’s morphology was characterized using X-ray computed tomography (CT) and scanning electron microscopy (SEM). A polychromatic pulsed X-ray source, high-speed camera and Kolsky bar apparatus were used in tandem, to observe the transient failure modes. A pin was placed at the end of the incident bar to control the location of damage initiation, and tests were performed at a constant velocity of ~6 m/s. These test conditions were observed to yield cracks with median and/or cone like geometries. Despite the variation in the crack paths, a significant difference in peak load was not observed. The failure mode was also observed to depend on the microstructure of the concrete samples.

Kolsky bar↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

A New Workflow of X-ray CT Image Processing and Data Analysis of Structural Features in Rock Using Open-Source Software

X-ray computed tomography (CT) images of rock specimens often contain artifacts which must be corrected before scientific analyses are performed. Here, we present a new workflow of automated image processing to utilize poor-quality X-ray CT scan images. The workflow runs on the open-source image analysis software and efficiently separates desired features from low-contrast scanned images. The new workflow is a two-step technique using contrast enhancement and automated feature segmentation to generate noise-free binary images. The results of binary images using the proposed workflow and using a conventional thresholding technique are analyzed to show the quality of the proposed method. The paper also presents a workflow of estimating the structural geometries of features in two and three dimensions. The results of the structural feature analyses and computational time were compared between the open-source (ImageJ) and commercial image analysis software (Bruker Computed Tomography Analyzer). The commercial software was more computationally efficient, but the task-specific macros in open-source software enabled the user-desired automation in image processing and data extraction of desired structural features of comparable quality.

47 OTHER INSTRUMENTATION↗