Search NASA⌕ Search

SEARCH · Search NASA

Results for “concentrated electrolyte”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Regulation of body fluid volume and electrolyte concentrations in spaceflight

Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian rhythms. Atrial natriuretic peptide does not seem to play an important role in the control of natriuresis during spaceflight. Inflight activity of the sympathetic nervous system, assessed by measuring catecholamines and their metabolites and precursors in body fluids, generally seems to be no greater than on Earth, but this system is usually activated at landing. Collaborative experiments on the Mir and the International Space Station should provide more of the data needed from long-term flights, and perhaps help to resolve some of the discrepancies between U.S. and Russian data. The use of alternative methods that are easier to execute during spaceflight, such as collection of saliva instead of blood and urine, should permit more thorough study of circadian rhythms and rapid hormone changes in weightlessness. More investigations of dietary intake of fluid and electrolytes must be performed to understand regulatory processes. Additional hormones that may participate in these processes, such as other natriuretic hormones, should be determined during and after spaceflight. Alterations in body fluid volume and blood electrolyte concentrations during spaceflight have important consequences for readaptation to the 1-G environment. The current assessment of fluid and electrolyte status during weightlessness and at landing and our still incomplete understanding of the processes of adaptation to weightlessness and readaptation to Earth's gravity have resulted in the development of countermeasures that are only partly successful in reducing the postflight orthostatic intolerance experienced by astronauts and cosmonauts. More complete knowledge of these processes can be expected to produce countermeasures that are even more successful, as well as expand our comprehension of the range of adaptability of human physiologic processes.

NASA Discipline Number 18-10↗

Electrolyte concentration changes during operation of the nickel cadmium cell

The concentration and distribution of aqueous potassium hydroxide (KOH) electrolyte in a sealed nickel cadmium cell is considered. The reactions at both electrodes during charge and discharge involve the production or utilization of hydroxyl ion (OH) or water (H2O) which directly affects concentration. Changes in electrolyte concentration relative to the individual electrode reactions is discussed. Quantitative values are provided for the changes in concentration for 6, 12, and 20 ah cells with accepted quantities of precharge and accepted initial quantity of 31% aqueous KOH. Consideration is given to a more correct equation which includes net changes in hydroxyl concentration in addition to water. Also, expected concentrations of electrolyte in cells in the fully charged, 75% charged, 50% charged, 25% charged and discharged condition are calculated. The expected concentration changes for cells in the accelerated tests are also tabulated and compared with measured values. All calculations are made on the assumption that there are no side reactions. Various properties which depend on KOH concentration are listed. The variables include O2, H2, and Cd(OH)2 solubilities in addition to viscosity and conductivity.

Halpert, G.↗

Electrolyte Concentrates Treat Dehydration

Wellness Brands Inc. of Boulder, Colorado, exclusively licensed a unique electrolyte concentrate formula developed by Ames Research Center to treat and prevent dehydration in astronauts returning to Earth. Marketed as The Right Stuff, the company's NASA-derived formula is an ideal measure for athletes looking to combat dehydration and boost performance. Wellness Brands also plans to expand with products that make use of the formula's effective hydration properties to help treat conditions including heat stroke, altitude sickness, jet lag, and disease.

Source record↗

Study to define and verify the personal oral hygiene requirements for extended manned space flight: Oral physiology and microbiology in Skylab manned space missions

Methods for metabolic fingerprinting of pathogenic oral bacteria were developed and the effects of Skylab missions on salivary electrolyte levels were studied. High resolution gas liquid chromatographic (GLC) and pyrolysis-GLC procedures were used to obtain metabolic profiles of closely related bacteria associated with dental caries and periodontal disease. It was found that the GLC procedures provide a practical and reproducible means of obtaining metabolic markers for identifying closely related strains of these organisms. Fractions of stimulated whole saliva samples from the prime and back-up crews of the three Skylab missions were used to measure salivary electrolyte concentrations. All the electrolytes previously reported as having increased in urine and feces during the missions were assessed. Sodium, potassium, calcium, magnesium, phosphorous and chloride were studied. A decrease in sodium and an increase in magnesium were observed, but the mineral imbalances attributable to the mission-related increases in urinary electrolytes were not detected.

Brown, L. R.↗

Electrolyte management considerations in modern nickel hydrogen and nickel cadmium cell and battery designs

In the early 1980's the NASA Lewis group addressed the topic of designing nickel hydrogen cells for LEO applications. As published in 1984, the design addressed the topics of gas management, liquid management, plate expansion, and the recombination of oxygen during overcharge. This design effort followed principles set forth in an earlier Lewis paper that addressed the topic of pore size engineering. At about that same time, the beneficial effect on cycle life of lower electrolyte concentrations was verified by Hughes Aircraft as part of a Lewis funded study. A succession of life cycle tests of these concepts have been carried out that essentially verified all of this earlier work. During these past two decades, some of the mysteries involved in the active material of the nickel electrode have been resolved by careful research efforts carried out at several laboratories. At The Aerospace Corporation, Dr. Zimmerman has been developing a sophisticated model of an operating nickel hydrogen cell which will be used to model certain mechanisms that have contributed to premature failures in nickel hydrogen and nickel cadmium cells. During the course of trying to understand and model abnormal nickel hydrogen cell behaviors, we have noted that not enough attention has been paid to the potassium ion content in these cells, and more recently batteries. Several of these phenomenon have been well known in the area of alkaline fuel cells, but only recently have they been examined as they might impact alkaline cell designs. This paper will review three general areas where the potassium ion content can impact the performance and life of nickel hydrogen and nickel cadmium devices, Once these phenomenon are understood conceptually, the impact of potassium content on a potential cell design can be evaluated with the aid of an accurate model of an operating cell or battery. All three of these areas are directly related to the volume tolerance and pore size engineering aspects of the components used in the cell or battery design: (1) The gamma phase uptake of potassium ion can result in a lowering of the electrolyte concentration. This leads to a higher electrolyte resistance as well as electrolyte diffusional limitations on the discharge rate. This phenomenon will also impact the response of the cell to a reconditioning cycle. (2) The impact of low level shunt currents in multi-cell con figurations will result in the movement of potassium ion from one part of the battery to another. This will impact the electrolyte volume/vapor pressure relationships within the cell or battery. (3) The transport of water vapor from place to place under the driving force of a tempetature gradient has already impacted cells for the case where water vapor is condensed on a colder cell wall. The paper will explore the convective and diffusive movement of gases saturated with water vapor from a warmer plate pack to a cooler one - both with and without liquid communication.

Thaller, L. H.↗

Development and testing of a high cycle life 30 A-h sealed AgO-Zn battery

A two-phase program was initiated to investigate design parameters and technology to develop an improved AgO-Zn battery. The basic performance goal was 100 charge/discharge cycles (22 h/2 h) at 50 percent depth of discharge following a six-month period of charged stand at room temperature. Phase 1, cell evaluation, involved testing 70 cells in five-cell groups. The major design variables were active material ratios, electrolyte concentrations, separator systems, and negative plate shape. Phase 1 testing showed that cycle life could be improved 10 percent to 20 percent by using greater ratios of zinc to silver oxide and higher electrolyte concentrations. Wedge-shaped negatives increased cycle life by nearly 100 percent. Phase 2 battery evaluation, which was initiated before the Phase 1 results were known completely, involved evaluation of six designs as 19-cell batteries. Only one battery exceeded 100 cycles following nine months charged stand.

Bogner, R. S.↗

New Secondary Batteries Utilizing Electronically Conductive Polypyrrole Cathode

To gain a better understanding of the dynamic behavior in electronically conducting polypyrroles and to provide guidance toward designs of new secondary batteries based on these polymers, two mathematical models are developed; one for the potentiostatically controlled switching behavior of polypyrrole film, and one for the galvanostatically controlled charge/discharge behavior of lithium/polypyrrole secondary battery cell. The first model is used to predict the profiles of electrolyte concentrations, charge states, and electrochemical potentials within the thin polypyrrole film during switching process as functions of applied potential and position. Thus, the detailed mechanisms of charge transport and electrochemical reaction can be understood. Sensitivity analysis is performed for independent parameters, describing the physical and electrochemical characteristic of polypyrrole film, to verify their influences on the model performance. The values of independent parameters are estimated by comparing model predictions with experimental data obtained from identical conditions. The second model is used to predict the profiles of electrolyte concentrations, charge state, and electrochemical potentials within the battery system during charge and discharge processes as functions of time and position. Energy and power densities are estimated from model predictions and compared with existing battery systems. The independent design criteria on the charge and discharge performance of the cell are provided by studying the effects of design parameters.

Yeu, Taewhan↗

Electrolysis cell stimulation

Computer program represents attempt to understand and model characteristics of electrolysis cells. It allows user to determine how cell efficiency is affected by temperature, pressure, current density, electrolyte concentration, characteristic dimensions, membrane resistance, and electrolyte circulation rate. It also calculates ratio of bubble velocity to electrolyte velocity for anode and cathode chambers.

Gordon, L. H.↗

Effect of training on blood volume and plasma hormone concentrations in the elderly

The purpose of this investigation was to determine the effects of 6 months of endurance training on resting plasma (PV) and blood volume (BV), and resting hormone and electrolyte concentrations in the elderly. Thirty-eight elderly men and women (ages 60-82 yr) were assigned to endurance exercise training (N = 29) or to control (N = 9) groups. Resting plasma levels of adrenocorticotropic hormone, vasopressin, aldosterone, norepinephrine, epinephrine, sodium, potassium, and protein were measured at the start (T1) and end (T2) of 26 wk of training. PV measurement was performed using the Evan's blue dye technique. Endurance training consisted of uphill treadmill walking or stairclimbing exercise 3 times.wk-1, 30-45 min.d-1, at 75-84% of maximal heart rate reserve. The exercise group increased VO2max by 11.2% (P < or = 0.05) and increased resting PV and BV by 11.2% and 12.7% (P < or = 0.05), respectively. Hormone and electrolyte levels in the exercise group remained unchanged; all variables were unchanged in the control group. These results are similar to findings in younger individuals. Because plasma hormone concentrations were maintained despite a chronically elevated BV, endurance training in healthy, elderly subjects may be associated with a resetting of volume receptors.

Clinical Trial↗

An Automated Method for Ozonesonde Calibration: New Insights

An automated method for preparation of the electrochemical concentration cell (ECC) ozonesonde is presented. Development of a computer-controlled system for preparation and calibration of the ECC is an improvement over the manual preparation method, and reduces subjectivity considerably. Preparation measurements in digital form aids analysis of the ECC before release and enhances post-flight data certification. Calibration of ozonesondes over a range of ozone concentrations between 0 mPA and 30 mPA is discussed. This presentation describes the automatic system, gives examples of calibrations. The automated system enables comparison of varying potassium iodide (KI) concentrations that should allow adjustment of earlier ozonesonde data obtained with different KT concentrations used since 1970, i.e., 2, 1.5, 1, and 0.5 percent. Preliminary results indicate ECC accuracy has a strong dependence on the electrolyte concentration and should not be considered linear with altitude.

Schmidlin, F. J.↗

Potential of zero charge

Frequency and electrolyte concentration effects on capacity on platinum electrode and relation to zero charge potential

FREQUENCY↗

Exploring Li-Air Batteries for High Specific Energy and High Power Applications: A Simulation Study

Commercialization of lithium-air batteries face many challenges, such as electrolyte decomposition, short cycle life, low energy efficiency, low power density, etc. However, commercialization of Li-air batteries for mass sensitive applications such as electric vehicles, portable power source, and drones is more challenging due to additional constraints of safety, electrolyte evaporation, high specific energy requirements, and reliable discharge times. In this presentation, we will present our finite element simulation results comparing Li-O2 and Li-air batteries using power density, energy density, specific power, and discharge times as metrics to evaluate different electrolytes and electrode geometry to reduce total mass and maximize discharge current. We use a finite element model and a discharge product model developed in which is based on porous electrode and concentrated electrolyte theories and the discharge product is modeled using quantum tunneling; for reaction kinetics and oxygen diffusion, an improved model was used. The electrolyte properties such as ion conductivity and ion diffusion were obtained from Molecular Dynamics (MD) simulations while the other parameters for the finite element model were calibrated to match experiments at high discharge current densities (>1.5 mA/cm2). The mass densities of different electrolytes were computed using MD simulations as well. For this presentation, we examine the practical electrochemical mass of a system at different current ratings, the sensitivity of mass to the use of ambient air as compared to pure oxygen as well as the electrolyte, which affects maximum current density and the total mass associated with the electrolyte (which includes the mass of additional components), and, the optimization of battery geometry for total discharge time, average discharge voltage, maximum discharge current, and minimum electrochemical mass.

Mehta, M.↗

Long-Duration Space Flight Provokes Pathologic Q-Tc Interval Prolongation

Space flight has a profound influence on the cardiovascular and autonomic nervous systems. Alterations in baroreflex function, plasma catecholamine concentrations, and arterial pressure regulation have been observed. Changes in autonomic regulation of cardiac function may lead to serious rhythm disturbances. In fact, ventricular tachycardia has been reported during long-duration space flight. The study aim was to determine the effects of space flight on cardiac conduction. Methods and Results: Electrocardiograms (ECGs) and serum electrolytes were obtained before and after short-duration (SD) (4-16 days) and long-duration (LD) (4-6 months) missions. Holter recordings were obtained from 3 different subjects before, during and after a 4-month mission. P-R, R-R, and Q-T intervals were measured manually in a random, blinded fashion and Bazzet's formula used to correct the Q-T interval (Q-Tc). Space flight had no clinically significant effect on electrolyte concentrations. P-R and RR intervals were decreased after SD flight (p<0.05) and recovered 3 days after landing. In the same subjects, P-R and Q-Tc intervals were prolonged after LD flight (p<0.01). Clinically significant Q-Tc prolongation (>0.44 sec) occurred during the first month of flight and persisted until 3 days after landing (p<0.01). Conclusions - Space flight alters cardiac conduction with more ominous changes seen with LD missions. Alterations in autonomic tone may explain ECG changes associated with space flight. Primary cardiac changes may also contribute to the conduction changes with LD flight. Q-Tc prolongation may predispose astronauts to ventricular arrhythmias during and after long-duration space flight.

D'Aunno, DOminick S.↗

Probabilistic Modeling of the Renal Stone Formation Module

The Integrated Medical Model (IMM) is a probabilistic tool, used in mission planning decision making and medical systems risk assessments. The IMM project maintains a database of over 80 medical conditions that could occur during a spaceflight, documenting an incidence rate and end case scenarios for each. In some cases, where observational data are insufficient to adequately define the inflight medical risk, the IMM utilizes external probabilistic modules to model and estimate the event likelihoods. One such medical event of interest is an unpassed renal stone. Due to a high salt diet and high concentrations of calcium in the blood (due to bone depletion caused by unloading in the microgravity environment) astronauts are at a considerable elevated risk for developing renal calculi (nephrolithiasis) while in space. Lack of observed incidences of nephrolithiasis has led HRP to initiate the development of the Renal Stone Formation Module (RSFM) to create a probabilistic simulator capable of estimating the likelihood of symptomatic renal stone presentation in astronauts on exploration missions. The model consists of two major parts. The first is the probabilistic component, which utilizes probability distributions to assess the range of urine electrolyte parameters and a multivariate regression to transform estimated crystal density and size distributions to the likelihood of the presentation of nephrolithiasis symptoms. The second is a deterministic physical and chemical model of renal stone growth in the kidney developed by Kassemi et al. The probabilistic component of the renal stone model couples the input probability distributions describing the urine chemistry, astronaut physiology, and system parameters with the physical and chemical outputs and inputs to the deterministic stone growth model. These two parts of the model are necessary to capture the uncertainty in the likelihood estimate. The model will be driven by Monte Carlo simulations, continuously randomly sampling the probability distributions of the electrolyte concentrations and system parameters that are inputs into the deterministic model. The total urine chemistry concentrations are used to determine the urine chemistry activity using the Joint Expert Speciation System (JESS), a biochemistry model. Information used from JESS is then fed into the deterministic growth model. Outputs from JESS and the deterministic model are passed back to the probabilistic model where a multivariate regression is used to assess the likelihood of a stone forming and the likelihood of a stone requiring clinical intervention. The parameters used to determine to quantify these risks include: relative supersaturation (RS) of calcium oxalate, citrate/calcium ratio, crystal number density, total urine volume, pH, magnesium excretion, maximum stone width, and ureteral location. Methods and Validation: The RSFM is designed to perform a Monte Carlo simulation to generate probability distributions of clinically significant renal stones, as well as provide an associated uncertainty in the estimate. Initially, early versions will be used to test integration of the components and assess component validation and verification (V&V), with later versions used to address questions regarding design reference mission scenarios. Once integrated with the deterministic component, the credibility assessment of the integrated model will follow NASA STD 7009 requirements.

kidney stones↗

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗

A Multi-Physics Study on High-Specific Power Li-O2 Batteries for Electric Aircraft

Commercialization of lithium-air batteries faces many challenges, such as electrolyte decomposition, short cycle life, low energy and power density, etc. However, commercialization of Li-O2 batteries for aeronautics is much more challenging due to additional safety constraints on cyclability and performance (high specific power and specific energy). For this presentation, we will discuss inter-related aspects of physics-based modeling of a pack: cell and battery model calibration. In addition, we will evaluate and present optimal battery designs for high discharge current density, high discharge time, and low battery mass using simulation-based optimization.The Finite Element Model (FEM) used to simulate a Li-O2 cell is based on the work of Bevara [1]. The different aspects of the model are based on: porous electrode theory and concentrated electrolyte theory; quantum tunneling model for the resistance of conformal layer of discharge product (Li2O2) [1]; Butler-Volmer kinetics for electrochemical reaction; Fick's diffusion for oxygen transport; and an oxygen dissolution model is applied at the air/electrolyte interface [2]. The electrolyte properties such as ion conductivity, ion diffusion, oxygen diffusion, and mass density of the electrolyte were taken from Molecular Dynamics (MD) simulations [3]; while the other model parameters, which includes mass of cell components, were calibrated to match experiments at high discharge current densities. The cell mass includes the anode, cathode, separator, electrolyte, and other components (such as current collector). This calibrated model is used to perform parametric studies on cathode thickness, porosity, tortuosity, carbon particle size, electrolyte transport and material properties, partial pressure of oxygen, discharge time, and discharge current density to study optimal designs for high specific power and energy. References:1. Bevara, V. & Andrei, P. (2014), J. Electrochem. Soc. 161 (14), A2068-A2079.2.Mehta, M. & Andrei, P. (2015), J. Power Sources. 286, 299-308.3.Liyana-Arachchi, T.; Haskins, J.; Burke, C.; Diederichsen, K.; McCloskey, B.; & Lawson, J. (2018), J. Phys. Chem. B. 122 (36), 8548 - 8559.4.Choi, W.; Kikumoto, H.; Choudhary, R. & Ooka, R. (2018), Applied Energy, 209, 306-321.

Mehta, Mohit↗

Modification of a fuel-cell engine for control by a digital computer

A manually operated fuel-cell system was modified to be monitored and controlled by a digital computer. The purpose was to have a test item with which to study possible system-computer interface problems. The modification consisted of installing solenoid valves, circuitry, transducers, and limit switches on the system. These modifications permit computer control of load current, reactant purge, water removal, and electrolyte concentration and computer initiation of system shutdown.

Hagedorn, N. H.↗