Search NASA⌕ Search

SEARCH · Search NASA

Results for “concentration profile fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Segregation of Impurities in Directionally Solidified Silicon

Hall measurements and four-point probe resistivity measurements are used to determine the concentration profile of boron and iron in doped semi-conductor silicon ingots grown by the Bridgman technique. The concentration profiles are fitted to the normal segregation equation and the effective segregation coefficient, K sub eff, is calculated. The average value of K sub eff, is 0.803 for boron. For iron, K sub eff, is concentration dependent and is in the range 0.00008 to 0.00012.

Ravishankar, P. S.↗

Impact of Gender on Pharmocokinetics of Intranasal Scopolamine

Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS), which is commonly experienced by astronauts during space missions. The bioavailability and pharmacokinetics (PK) were evaluated under IND guidelines. Since information is lacking on the effect of gender on the PK of Scopolamine, we examined gender differences in PK parameters of INSCOP at three dose levels of 0.1, 0.2 and 0.4 mg. Methods: Plasma scopolamine concentrations as a function of time data were collected from twelve normal healthy human subjects (6 male/6 female) who participated in a fully randomized double blind crossover study. The PK parameters were derived using WinNonlin. Covariate analysis of PK profiles was performed using NONMEN and statistically compared using a likelihood ratio test on the difference of objective function value (OFV). Statistical significance for covariate analysis was set at P<0.05(ΔOFV=3.84). Results: No significant difference in PK parameters between male and female subjects was observed with 0.1 and 0.2 mg doses. However, CL and Vd were significantly different between male and female subjects at the 0.4 mg dose. Results from population covariate modeling analysis indicate that a onecompartment PK model with first-order elimination rate offers best fit for describing INSCOP concentration-time profiles. The inclusion of sex as a covariate enhanced the model fitting (ΔOFV=-4.1) owing to the genderdependent CL and Vd differences after the 0.4 mg dose. Conclusion: Statistical modeling of scopolamine concentration-time data suggests gender-dependent pharmacokinetics of scopolamine at the high dose level of 0.4 mg. Clearance of the parent compound was significantly faster and the volume of distribution was significantly higher in males than in females, As a result, including gender as a covariate to the pharmacokinetic model of scopolamine offers the best fit for PK modeling of the drug at dose of 0.4 mg or higher.

Putcha, L.↗

Thermal and solutal conditions at the tips of a directional dendritic growth front

The line-of-sight averaged, time-dependent dendrite tip concentrations for the diffusion dominated vertical directional solidification of a metal model (ammonium chloride and water) were obtained by extrapolating exponentially fit diffusion layer profiles measured using a laser interferometer. The tip concentrations were shown to increase linearly with time throughout the diffusion dominated growth process for an initially stagnant dendritic array. The process was terminated for the cases chosen by convective breakdown suffered when the conditionally stable diffusion layer exceeded the critical Rayleigh criteria. The transient tip concentrations were determined to significantly exceed the values predicted for steady state, thus producing much larger constitutional undercoolings. This has ramifications for growth speeds, arm spacings and the dendritic structure itself.

Mccay, T. D.↗

Solutal diffusion coefficient for liquid PbTe-SnTe

The solutal diffusion coefficient has been determined for liquid lead telluride-tin telluride using a modified shear cell technique. Postdiffusion concentration profiles are presented for several diffusion couples. The best analytical curve fit to the data gives a composition-dependent diffusion coefficient of (/3/7/ to the C power) x 0.00014 sq cm/sec, where C is the PbTe concentration. In addition, data are presented to show the importance of solutal convection in the lead-tin-telluride system.

Clark, I. O.↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

Validation of a Best-Fit Pharmacokinetic Model for Scopolamine Disposition after Intranasal Administration

An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Motion Sickness. Bioavailability and pharmacokinetics (PK) were determined per Investigative New Drug (IND) evaluation guidance by the Food and Drug Administration. Earlier, we reported the development of a PK model that can predict the relationship between plasma, saliva and urinary scopolamine (SCOP) concentrations using data collected from an IND clinical trial with INSCOP. This data analysis project is designed to validate the reported best fit PK model for SCOP by comparing observed and model predicted SCOP concentration‐time profiles after administration of INSCOP.

Wu, L.↗

Time-dependent oral absorption models

The plasma concentration-time profiles following oral administration of drugs are often irregular and cannot be interpreted easily with conventional models based on first- or zero-order absorption kinetics and lag time. Six new models were developed using a time-dependent absorption rate coefficient, ka(t), wherein the time dependency was varied to account for the dynamic processes such as changes in fluid absorption or secretion, in absorption surface area, and in motility with time, in the gastrointestinal tract. In the present study, the plasma concentration profiles of propranolol obtained in human subjects following oral dosing were analyzed using the newly derived models based on mass balance and compared with the conventional models. Nonlinear regression analysis indicated that the conventional compartment model including lag time (CLAG model) could not predict the rapid initial increase in plasma concentration after dosing and the predicted Cmax values were much lower than that observed. On the other hand, all models with the time-dependent absorption rate coefficient, ka(t), were superior to the CLAG model in predicting plasma concentration profiles. Based on Akaike's Information Criterion (AIC), the fluid absorption model without lag time (FA model) exhibited the best overall fit to the data. The two-phase model including lag time, TPLAG model was also found to be a good model judging from the values of sum of squares. This model also described the irregular profiles of plasma concentration with time and frequently predicted Cmax values satisfactorily. A comparison of the absorption rate profiles also suggested that the TPLAG model is better at prediction of irregular absorption kinetics than the FA model. In conclusion, the incorporation of a time-dependent absorption rate coefficient ka(t) allows the prediction of nonlinear absorption characteristics in a more reliable manner.

Non-NASA Center↗

Discovery of a New Cassini-Size Basin on Mars from MOLA Topographic Data

MOLA profile data collected during the Science Phasing Operations have revealed a previously unknown, 450 km wide, 2 km deep basin on Mars centered at 30N, 312W near the Phison Rupes. This structure, as large as and somewhat deeper than the very obvious Cassini impact basin located 1000 km to the SW, is not apparent in the existing good quality Viking imagery. Gridded MOLA data show the basin as a closed depression, but elevation contours show only weak correlation with what little structure exists in the area and with mapped geologic units. From analysis of slope breaks readily visible in two MOLA profiles we suggest this is at least a three-ring basin. Portions of rings from concentric fits to slope breaks align with some of the linear ridge-like structures of the Phison Rupes, and outline a region of lower crater density and smoother inter-crater plains. The discovery of such a pronounced topographic depression which lacks obvious visible structure suggests more such previously unknown features may exist on Mars, and that MOLA data may be useful in finding them.

Frey, H.↗

Current State of Modeling the Photochemistry of Titan's Mutually Dependent Atmosphere and Ionosphere

In the context of recent observations, microphysical models, and laboratory data, a photochemical model of Titan's atmosphere, including updated chemistry focusing on rate coefficients and cross sections measured under appropriate conditions, has been developed to increase understanding of these processes and improve upon previous Titan photochemical models. The model employs a two-stream discrete ordinates method to characterize the transfer of solar radiation, and the effects of electron-impact, cosmic-ray deposition, and aerosol opacities from fractal and Mie particles are analyzed. Sensitivity studies demonstrate that an eddy diffusion profile with a homopause level of 850 km and a methane stratospheric mole fraction of 2.2% provides the best fit of stratospheric and upper atmosphere observations and an improved fit over previous Titan photochemical models. Lack of fits for C3H8, HC3N, and possibly C2H3CN can be resolved with adjustments in aerosol opacity. The model presents a benzene profile consistent with its detection in Titan's stratosphere [Coustenis et al., 2003], which may play an important role in the formation of Titan hazes. An electron peak concentration of 4200 cm(exp -3) is calculated, which exceeds observations by 20%, considerably lower than previous ionosphere models. With adjustments in aerosol opacities and surface fluxes the model illustrates that reasonable fits to existing observations are possible with a single eddy diffusion profile, contrary to the conclusions of previous Titan models. These results will aid in the receipt and interpretation of data from Cassini-Huygens, which will arrive at Titan in 2004 and deploy a probe into Titan's atmosphere in January 2005.

ion chemistry↗

A New Fitting Procedure for the Blended He I 1083 nm Multiplet

The He I 1083 nm multiplet is a powerful tool for observing the outer solar atmosphere but is difficult to analyze because the lines are weak, highly variable, and spectrally blended, both internally and with other neighboring solar and telluric lines. After separation from nearby spectral features, two components of the He I multiplet are resolved. Fitting these lines with two unconstrained Gaussian profiles always gives a ratio of major to minor component of less than half the value which would be expected for optically thin lines. One possibility for explaining the discrepancy between the weakness of the lines and the ratio of the spectral components is to assume that the line formation regions are concentrated in laterally unresolved, optically thick structures with small filling factor. However, we present here a least-squares fitting technique using cubic splines with fixed breakpoints with the constraint that the blend is the sum of three identically shaped profiles shifted in wavelength according to the atomic structure of the blend and weighted by the corresponding statistics weights, in agreement with optically thin line formation. The basis functions for the fitting procedure have no built-in spectral symmetry or shape. The resulting underlying profiles tend to be asymmetric with excess absorption to the blue, consistent with formation by "hot" and "cool" spatial elements within the observed volume, with the hotter regions having differential motion toward the observer. The results agree well with NASA/XSO Spectromagnetograph observations in quiet sun and coronal holes. Partial funding of this research was provided through the NASA Sun-Earth Connection SR&T program.

Jones, H. P.↗

Radiation and chemistry in the stratosphere - Sensitivity to O2 absorption cross sections in the Herzberg continuum

It is suggested that the discrepancies between observed and modeled vertical profiles of such halocarbons as CFCl3, as well as the problem of simultaneously fitting N2O, CH4, CF2Cl2 and CFCl3 profiles with a single eddy diffusion model, are due to an overestimation of the molecular oxygen absorption cross sections in the 200-220 nm spectral region. The replacement of current O2 cross sections in this range with values that are in better agreement with results for the compounds cited leads to N2O, CF2Cl2 and CFCl3 concentration reductions of factors 0.70, 0.62 and 0.19, respectively. Profiles of CH4, H2 and CO remain unchanged, and the predicted concentration of HNO3 above 30 km is reduced by about 50% for yet another improved fit with observations. It is noted that the correction proposed produces a 30% ozone increase near the 20-25 km peak.

Froidevaux, L.↗

Coronal Magnetography of Solar Active Regions Using Coordinated SOHO/CDS and VLA Observations

The purpose of this project is to apply the coronal magnetographic technique to SOHO (Solar Heliospheric Observatory) /CDS (Coronal Diagnostic Spectrometer) EUV (Extreme Ultraviolet Radiation) and coordinated VLA microwave observations of solar active regions to derive the strength and structure of the coronal magnetic field. A CDS observing plan was developed for obtaining spectra needed to derive active region differential emission measures (DEMs) required for coronal magnetography. VLA observations were proposed and obtained. SOHO JOP 100 was developed, tested, approved, and implemented to obtain coordinated CDS (Coronal Diagnostic Spectrometer)/EIT (Ultraviolet Imaging Telescope)/ VLA (Very Large Array)/ TRACE (Transition Region and Coronal Explorer)/ SXT (Solar X Ray Telescope) observations of active regions on April 12, May 9, May 13, and May 23. Analysis of all four data sets began, with heaviest concentration on COS data. It is found that 200-pixel (14 A in NIS1) wavelength windows are appropriate for extracting broadened Gaussian line profile fit parameters for lines including Fe XIV at 334.2, Fe XVI at 335.4, Fe XVI at 360.8, and Mg IX at 368.1 over the 4 arcmin by 4 arcmin CDS field of view. Extensive efforts were focused on learning and applying were focused on learning and applying CDS software, and including it in new IDL procedures to carry out calculations relating to coronal magnetography. An important step is to extract Gaussian profile fits to all the lines needed to derive the DEM in each spatial pixel of any given active region. The standard CDS absolute intensity calibration software was applied to derived intensity images, revealing that ratios between density-insensitive lines like Fe XVI 360.8/335.4 yield good agreement with theory. However, the resulting absolute intensities of those lines are very high, indicating that revisions to the CDS absolute intensity calibrations remain to be included in the CDS software, an essential step to deriving reliable coronal magnetograms. With lessons learned and high quality data obtained during the past year, coronal magnetography will be successfully pursued under my new SOHO GI program.

Brosius, Jeffrey W.↗

Electrical Capacitance Volume Tomography for the Packed Bed Reactor ISS Flight Experiment

Fixed packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a highly desirable unit operation for long duration life support systems in space. NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. To validate these models, the instantaneous distribution of the gas and liquid phases must be measured.Electrical Capacitance Volume Tomography (ECVT) is a non-invasive imaging technology recently developed for multi-phase flow applications. It is based on distributing flexible capacitance plates on the peripheral of a flow column and collecting real-time measurements of inter-electrode capacitances. Capacitance measurements here are directly related to dielectric constant distribution, a physical property that is also related to material distribution in the imaging domain. Reconstruction algorithms are employed to map volume images of dielectric distribution in the imaging domain, which is in turn related to phase distribution. ECVT is suitable for imaging interacting materials of different dielectric constants, typical in multi-phase flow systems. ECVT is being used extensively for measuring flow variables in various gas-liquid and gas-solid flow systems. Recent application of ECVT include flows in risers and exit regions of circulating fluidized beds, gas-liquid and gas-solid bubble columns, trickle beds, and slurry bubble columns. ECVT is also used to validate flow models and CFD simulations. The technology is uniquely qualified for imaging phase concentrations in packed bed reactors for the ISS flight experiments as it exhibits favorable features of compact size, low profile sensors, high imaging speed, and flexibility to fit around columns of various shapes and sizes. ECVT is also safer than other commonly used imaging modalities as it operates in the range of low frequencies (1 MHz) and does not radiate radioactive energy. In this effort, ECVT is being used to image flow parameters in a packed bed reactor for an ISS flight experiment.

Tomography↗

Production of CS and S in Comet Bradfield /1979 X/

High and low resolution ultraviolet spectra of carbon monosulfide (CS) in Comet Bradfield (1979 X) were obtained with the IUE satellite. The high resolution rotational profile of the (0, 0) band at 257.5 nm can be fitted with a theoretical profile derived assuming a Boltzmann temperature of 70 K. Spatial plots of the low resolution data for both S and CS show that these emissions are concentrated toward the cometary nucleus. The results that have been obtained are consistent with a Haser model for CS and S where the parent molecule is CS2. A very rapid variation of CS brightness with heliocentric distance is found.

Jackson, W. M.↗

Chandra X-ray Grating Spectrometry of Eta Carinae near X-ray Minimum: I. Variability of the Sulfur and Silicon Emission Lines

We report on variations in important X-ray emission lines in a series of Chandra grating spectra of the supermassive colliding wind binary star eta Car, including key phases around the X-ray minimum/periastron passage in 2003.5. The X-rays arise from the collision of the slow, dense wind of eta Car with the fast, low-density wind of an otherwise hidden companion star. The X-ray emission lines provide the only direct measure of the flow dynamics of the companion's wind along the wind-wind collision zone. We concentrate here on the silicon and sulfur lines, which are the strongest and best resolved lines in the X-ray spectra. Most of the line profiles can be adequately fit with symmetric Gaussians with little significant skewness. Both the silicon and sulfur lines show significant velocity shifts and correlated increases in line widths through the observations. The R = forbidden-to-intercombination ratio from the Si XIII and S XV triplets is near or above the low-density limit in all observations, suggesting that the line-forming region is > 1.6 stellar radii from the companion star, and that the emitting plasma may be in a non-equilibrium state. We show that simple geometrical models cannot simultaneously fit both the observed centroid variations and changes in line width as a function of phase. We show that the observed profiles can be fitted with synthetic profiles with a reasonable model of the emissivity along the wind-wind collision boundary. We use this analysis to help constrain the line formation region as a function of orbital phase, and the orbital geometry. Subject headings: X-rays: stars -stars: early-type-stars: individual (q Car)

Henley, D. B.↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Equatorial ozone profiles from the Solar Maximum Mission - A comparison with theory

The UV spectrometer polarimeter on the Solar Maximum Mission has been utilized to measure mesospheric O3 altitude profiles by the technique of solar occultation. Sunset data are presented for 1980, during the fall equinoctal period within + or - 20 deg of the geographic equator. Mean O3 concentrations are (40, 16, 5.5, and 1.5) x 10 to the 9th/cu cm at 50, 55, 60, and 65 km, respectively. Some profiles exhibit altitude structure which is wavelike. The mean O3 profile is fit best with the results of a time-dependent model if the assumed water-vapor mixing ratio employed varies from 6 ppm at 65 km.

Aikin, A. C.↗

Variations in the upper stratosphere's ozone profile

The ozone concentration profile was measured on five balloon flights using an instrument which employs the strong absorption in ultraviolet to measure ozone in situ. Altitudes up to 44 km were obtained. All the flights were made during the daytime except for one that was launched at 3 AM local time to obtain a nighttime profile and to observe sunrise effects. Although the measurements were obtained at different times of day and during different seasons, ozone concentrations in the upper stratosphere varied by only a few percent. Quadratic, least squares fits to the data between 34 km and 40 km for the four daytime flights, yield a mean concentration at 37 km of 1.02 x 10 to the 12th power molecules/cu cm with a 2 percent standard deviation. Measurements made through sunrise show a small increase in ozone at 37 km commencing shortly after the beginning of astronomical twilight. The concentration at 37 km returned to predawn levels about 2 1/2 hours later.

Robbins, D. E.↗