Search NASA⌕ Search

SEARCH · Search NASA

Results for “condensate pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Capillary-Condenser-Pumped Heat-Transfer Loop

Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

Silverstein, Calvin C.↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

Operation and maintenance costs for nuclear power plants are very large. Reactors are starting to shut down even after their operating licenses have been extended, because they are not price competitive compared to other energy sources. The nuclear industry is witnessing early closure of nuclear power plants due to economic reasons despite excellent safety records. Therefore, it is imperative to reduce costs to prevent these early closures. This paper showcases recent research into advanced fault diagnostics techniques and preventative maintenance optimization to reduce these maintenance costs. This report focuses on the condensate and feedwater system for both pressurized and boiling water reactor systems. The computerized maintenance management system, which contains the plant’s digital record of all the corrective- and preventative-maintenance work orders, was used as a ground truth to locate potential faults and label the process data as healthy or faulty. Various feature extraction techniques were utilized to further differentiate the faults from the healthy data. Support vectors machines were used to categorize other test sets of process data as healthy or faulty through a cross validation procedure. Similar faults were not found within this system leading to preventative maintenance optimization. Unnecessary amounts of preventative maintenance lead to inflated maintenance costs. This paper summarizes the steps for preventative maintenance optimization from component health determination to recommendation for action. This optimization was completed for condensate pumps, condensate booster pumps, and the respective motors that drive them.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization NPIC presentation

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Closed-cycle power supply for fluidic control systems

Power supply utilizes small quantities of two-phase fluid of suitable thermodynamic properties for circulation in a capillary-pumped heat transfer loop. Fluid is vaporized in evaporator, passed through fluidic system load, condensed, pumped by multistage capillary pump, and returned to the evaporator.

Fiet, O.↗

Gravity Effects in Condensing and Evaporating Films

A general overview of gravity effects in condensing and evaporating films is presented. The topics include: 1) Research Overview; 2) NASA Recognizes Critical Need for Condensation & Evaporation Research to Enable Human Exploration of Space; 3) Condensation and Evaporation Research in Reduced Gravity is Enabling for AHST Technology Needs; 4) Differing Role of Surface Tension on Condensing/Evaporating Film Stability; 5) Fluid Mechanisms in Condensing and Evaporating Films in Reduced Gravity; 6) Research Plan; 7) Experimental Configurations for Condensing Films; 8) Laboratory Condensation Test Cell; 9) Aircraft Experiment; 10) Condensation Study Current Test Conditions; 11) Diagnostics; 12) Shadowgraph Images of Condensing n- pentane Film in Unstable (-1g) Configuration; 13) Condensing n-Pentane Film in Normal Gravity (-1g) at Constant Pressure; 14) Condensing n-Pentane Film in Normal Gravity (-1g) with Cyclic Pressure; 15) Non-condensing Pumped Film in Normal Gravity (-1g); 16) Heat Transfer Coefficient in Developing, Unstable Condensing Film in Normal Gravity; 17) Heat Transfer for Unsteady Condensing Film (-1g); 18) Ultrasound Measurement of Film Thickness N-pentane Film, Stable (+1g) Configuration; and 19) Ultrasound Measurement of Film Thickness N-pentane Film, Unstable (-1g) Configuration.

Hermanson, J. C.↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

Thermal Control Utilizing an Thermal Control Utilizing an Two-Phase Loop with High Heat Flux Source

The electric field applied in dielectric fluids causes an imbalance in the dissociation-recombination reaction generated free space charges. The generated charges are redistributed by the applied electric field resulting in the heterocharge layers in the Vicinity of the electrodes. Proper design of the electrodes generates net axial flow motion pumping the fluid. The electrohydrodynamic (EHD) conduction pump is a new device that pumps dielectric fluids utilizing heterocharge layers formed by imposition of electrostatic fields. This paper evaluates the experimental performance of a two-phase breadboard thermal control loop consisting of an EHD conduction pump, condenser, pre-heater, high heat flux evaporator (HE), transport lines, and reservoir (accumulator). The generated pressure head and the maximum applicable heat flux are experimentally determined at various applied voltages and sink temperatures. Recovery from dryout condition by increasing the applied voltage to the pump is also demonstrated.

Jeong, Seong-Il↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

DEMONSTRATION OF A PASSIVE CONDENSER LOOP

Building HVAC consumes significant amount of energy. It is estimated that about 7% of the total electricity consumed by water cooled chiller is used to drive the condenser water pump. A passive condenser loop is developed to curb this energy consumption by replacing the open pumped loop to a closed loop thermosyphon system. The loop thermosyphon uses waste heat to circulate the condenser fluid, eliminating the electrical pumping power requirement and the large circulation pump. Since it is a closed loop, it also reduces the maintenance cost and enables both wet and dry cooling modes. A demonstration unit with a riser about 40 feet (12.2 meters) tall is fabricated and tested at powers up to 25 kW. The result has successfully showed that the loop thermosyphon is able to transfer the heat near isothermally (∆T < 0.4C) over the long distance without the need of any pump and consuming any electricity.

Loop thermosyphon, building HVAC, condenser loop↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗