An Authentication Vulnerability Assessment of Connected Lighting Systems

Emerging connected lighting systems (CLS) that incorporate distributed intelligence, network interfaces, and sensors can become data-collection platforms that enable a wide range of valuable new capabilities as well as greater energy savings in buildings and cities. However, CLS technology is currently at an early stage of development, and its increased connectivity introduces cybersecurity risks that are new to the lighting industry and that must be addressed for successful integration with other systems. While a number of existing frameworks, guidelines, and tests for evaluating cybersecurity vulnerability may apply to CLS in whole or in part, there is currently no mandatory requirement for cybersecurity testing or certification. The lighting industry, including technology developers and specification organizations, is currently evaluating the suitability of existing frameworks and guidelines for CLS. To support these efforts, Pacific Northwest National Laboratory (PNNL) is conducting a series of studies intended to educate lighting industry stakeholders on specific cybersecurity practices and characterize their implementation in commercially available CLS with varying system architectures, network-communication technologies, and degrees of maturity. This study demonstrates that tests for authentication vulnerabilities can be developed with objective pass/fail criteria, therby facilitating comparisons between CLS. Based on the limited results of this study, it appears that the CLS that are being brought to market have varying levels of authentication vulnerability. It is hoped that these evaluations will support and perhaps accelerate industry discussions on the risks of specific security vulnerabilities, what vulnerabilities should be addressed by in-development of future lighting-specific best practices, and whether any such practices should be included in voluntary lighting standards.

42 ENGINEERING↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Observational Understanding of Connected Lighting Systems

As part of the Internet of Things (IoT), connected lighting systems provide additional control capabilities and nonlighting-related services (such as communications and data infrastructure) to reduce energy use while increasing both application efficiency and system value. But the positive or negative energy impact of implementing these systems is still largely unknown due to the variety of human factors associated with installation, maintenance, and use. These complications interfere with adoption and acceptance rates of products that will play a significant role in achieving energy savings long-term. Next Generation Lighting Systems, or NGLS, developed and implemented an observational research methodology for connected lighting systems. The methodology was implemented at an indoor (classroom/office) Living Lab at Parsons School of Design in New York City, and an outdoor (parking lot) Living Lab at Virginia Tech Transportation Institute in Blacksburg, Virginia. Although this report focuses on the approach to indoor installations, observational research in both settings provides insight to the type, scale, and frequency of issues across available products as experienced by installing contractors, end users, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Influence of Communication on the Complexity of Connected Lighting Systems

Experience in the Next Generation Lighting Systems (NGLS) ”Living Lab” at the Parsons School of Design, has clearly shown the impacts of communication on the configuration complexity of the connected lighting systems installed there. Since 2017, NGLS has invited manufacturers to submit connected lighting systems for assessment against a set of specifications. To date, 14 systems of wirelessly connected LED luminaires and controls have been installed in classrooms with existing lighting. In nine of the rooms, new LED linear pendants or recessed troffers replaced existing luminaires; in the other rooms, LED “kits” were retrofitted into the existing troffers. Eleven of the installations featured sensors integrated in the luminaires or retrofit kits; the others used ceiling mounted sensors. All systems provided wall control devices for manual operation. For half of the installations, the complete systems were furnished by single companies; for the other half, luminaires and controls were furnished by separate companies. A total of 18 different companies provided products, with four of these located outside the United States including, Korea, Poland, Germany, and the Netherlands. In addition, two different electrical contractors in New York City provided multiple installation teams totaling 10 individuals, none of whom were familiar with any of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Wall Control Performance on Connected Lighting Systems

Wall controls form the only touchpoint for individual room users and that room’s lighting control system. As such, these interfaces strongly influence user understanding and utilization of the system, as well as overall acceptance. The Next Generation Lighting Systems (NGLS) program began an evaluation of the wall controls in 14 connected lighting systems installed in various rooms of the NGLS Living Lab at Parsons School of Design in New York City. These systems demonstrate the wide range of approaches to wall control setup and functionality taken by manufacturers. Characterizing the 14 controls across six attributes, only four, or 29%, were identical. Requirements for wall control design were not specified explicitly by NGLS. Rather, wall controls were required to provide system performance according to three criteria: vacancy control (manual on/auto off) of two zones; manual continuous dimming of the same two zones; and an AV presentation mode in one of the two zones. This report examines the classification of entries, the assessment method used to evaluate the systems from installation through day-to-day use, and the system performance observed to date for each.

42 ENGINEERING↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

A Cybersecurity Threat Profile for a Connected Lighting System

In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement.

97 MATHEMATICS AND COMPUTING↗

Presence Detection in Connected Lighting Systems

Despite established technology and decades of experience, presence detection still faces challenges, including resistance to its use. This report provides context for current presence detection in lighting, considers various failure modes and their causes, characterizes various approaches to implementing presence detection, and describes performance evaluation as conducted in classrooms and offices at the Living Lab.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing Connected Lighting Systems

In the context of evaluating a lighting control system, characterization refers to the identification and description of key attributes and distinctive features of that system. NGLS has to date characterized both the form and function of 14 lighting control systems installed in the Living Lab at Parsons School of Design in New York City. The goal of NGLS characterizations in the Living Lab has been to achieve a broad understanding of “these types of systems” as a class, rather than a detailed description of any individual system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hadronic Vacuum Polarization for the Muon 𝑔 − 2 from Lattice QCD: Long-Distance and Full Light-Quark Connected Contribution

We present results for the dominant light-quark connected contribution to the long-distance window of the hadronic vacuum polarization (HVP) contribution to the muon 𝑔 − 2 from lattice quantum chromodynamics. Specifically, with a new determination of the lattice scale on MILC’s physical-mass HISQ ensembles, using the Ω− baryon mass, we obtain a result of 𝑎$^{𝑙⁢𝑙,LD}_{𝜇}$⁡(conn) = 400.2⁢(2.3) stat ⁢(3.7) syst ⁢[4.3] total × 10 −10 . Summing this result with our recent determinations of the light-quark connected contributions to the short- and intermediate-distance windows, we obtain a subpercent precision determination of the light-quark-connected contribution to HVP of 𝑎$^{𝑙⁢𝑙}_{𝜇}$⁡(conn) = 655.2⁢(2.3) stat ⁢(3.9) syst ⁢[4.5]total×10 −10 . Finally, as a consistency check, we verify that an independent analysis of the full contribution is in agreement with the sum of individual windows. We discuss our future plans for improvements of our HVP calculations to meet the target precision of the Fermilab 𝑔 − 2 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Leveraging Multiple Connected Traffic Light Signals in an Energy-Efficient Speed Planner

Connecting automated vehicles to traffic lights can lead to significant energy savings by enabling them to pass through intersections in an energy-efficient way without unnecessary stops. A cellular-based communication system connecting multiple traffic lights can help realize the full potential of energy-efficient driving at intersections. Thus, we propose a hierarchical speed planner that can leverage information from multiple connected traffic lights. The proposed speed planner consists of two modules: a green window selector and a reference trajectory generator. The green window selector, based on Dijkstra’s algorithm, finds a series of "green windows" for connected traffic lights that builds an energy-optimal path for vehicles to follow. The reference trajectory generator finds optimal entering times, based on the selected green window at each intersection, and then computes reference trajectories. Deriving and using analytical optimal entering speeds as a function of entering times allows us to guarantee the computational simplicity suitable for real-time implementation. We also demonstrate how to balance energy and traffic flow perspectives in the reference trajectory generator. Lastly, a high-fidelity simulation framework is used to evaluate the proposed speed planner and quantify the extent to which it can save energy in various real-world urban route scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opening the Door to Grid-Interactive Efficient Buildings with Energy Codes

Building codes represent standard design practice in the construction industry and must continually evolve to account for advancing technologies and innovative practices. Energy codes have historically focused on energy efficiency within buildings and across their systems. However, many of tomorrow's technologies go beyond efficiency and target increased flexibility. These demand flexibility (DF) measures can postpone or reduce building electric load based on price or other grid signals, and include smart appliances, connected lighting, and connected mechanical systems. Expanding codes to enable such grid-interactive efficient building (GEB) has the potential to influence their realization at scale, which will support renewable-energy grid-integration and building-sector decarbonization. However, considering DF measures in code development creates a new set of challenges for codes and the practices contained therein. This paper considers the role of building energy codes in enabling GEB. Specifically, it reviews the status of demand flexibility (DF) measures in current commercial building energy code. It examines the national model code development process and identifies components barring the consideration and inclusion of DF measures - including code scope, characterization and analysis of proposed new prescriptive measures, and accounting for time-of-day and geographic differences in their benefits. The paper presents findings from code development analyses that indicate the cost benefit of DF measures and the limitations associated with current code development conventions. To encourage building flexibility and improved energy resilience moving forward, recommendations are made for removing code development barriers and sanctioning DF measure consideration in future model codes.

Building Energy Codes and Standards, Grid-Interact↗

Data-driven estimates for light-quark-connected and strange-plus-disconnected hadronic g − 2 window quantities

A number of discrepancies have emerged between lattice computations and data-driven dispersive evaluations of the RBC/UKQCD intermediate-window-hadronic contribution to the muon anomalous magnetic moment. It is therefore interesting to obtain data-driven estimates for the light-quark-connected and strange-plus-disconnected components of this window quantity, allowing for a more detailed comparison between the lattice and data-driven approaches. The aim of this paper is to provide these estimates, extending the analysis to several other window quantities, including two windows designed to focus on the region in which the two-pion contribution is dominant. Clear discrepancies are observed for all light-quark-connected contributions considered, while good agreement with lattice results is found for strange-plus-disconnected contributions to the quantities for which corresponding lattice results exist. The largest of these discrepancies is that for the RBC/UKQCD intermediate window, where, as previously reported, our data-driven result, a μ W 1 , lqc = 198.9 ( 1.1 ) × 10 − 10 , is in significant tension with the results of 8 different recent lattice determinations. Our strategy is the same as recently employed in obtaining data-driven estimates for the light-quark-connected and strange-plus-disconnected components of the full leading-order hadronic vacuum polarization contribution to the muon anomalous magnetic moment. Updated versions of those earlier results are also presented, for completeness. Published by the American Physical Society 2024

Benton, Genessa (ORCID:0009000515763654)↗

Data-driven results for light-quark connected and strange-plus-disconnected hadronic g − 2 short- and long-distance windows

A key issue affecting the attempt to reduce the uncertainty on the Standard Model prediction for the muon anomalous magnetic moment is the current discrepancy between lattice-QCD and data-driven results for the hadronic vacuum polarization. Progress on this issue benefits from precise data-driven determinations of the isospin-limit light-quark-connected (lqc) and strange-plus-light-quark-disconnected ( s + lqd ) components of the related RBC/UKQCD windows. In this paper, using a strategy employed previously for the intermediate window, we provide data-driven results for the lqc and s + lqd components of the short- and long-distance RBC/UKQCD windows. Comparing these results with those from the lattice, we find significant discrepancies in the lqc parts but good agreement for the s + lqd components. We also explore the impact of recent CMD- 3 e + e − → π + π − cross section results, demonstrating that an upward shift in the ρ -peak region of the type seen in the CMD-3 data serves to eliminate the discrepancies for the lqc components without compromising the good agreement between lattice and data-driven s + lqd results. Published by the American Physical Society 2025

Benton, Genessa (ORCID:0009000515763654)↗

Light-quark connected intermediate-window contributions to the muon 𝑔 − 2 hadronic vacuum polarization from lattice QCD

We present a lattice-QCD calculation of the light-quark connected contribution to window observables associated with the leading-order hadronic vacuum polarization contribution to the anomalous magnetic moment of the muon, $a^{HVP,LO}_μ$. We employ the MILC Collaboration’s isospin-symmetric QCD gauge-field ensembles, which contain four flavors of dynamical highly improved staggered quarks with four lattice spacings between $a ≈ 0.06-0.15$ fm and close-to-physical quark masses. We consider several effective-field-theory-based schemes for finite volume and other lattice corrections and combine the results via Bayesian model averaging to obtain robust estimates of the associated systematic uncertainties. After unblinding, our final results for the intermediate and "W2" windows are $a^{U,W}_μ$(conn) = 206.6(1.0) x 10 -10 and $a^{U,W2}_μ$ (conn) = 100.7(3.2) x 10 -10 , respectively

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Let's Get Greedy: The L-Prize Invites Innovators to 'Have It All'

LEDs have arrived. They’re long-lasting, energy-efficient, and priced competitively with the products they’re replacing. Case closed and let’s move on, right? And yet… transformative lighting has the capacity do more, with excellent energy and application efficiency, data-driven functionality, material sustainability, and the ability to make buildings better places to work, live, learn, and heal – for people in all communities. This article on the DOE L-Prize invites competitors to participate in the $12.2 million L-Prize competition. The competition sets ambitious innovation goals for efficacy, quality of light, connectivity, material sustainability, and diversity, equity, and inclusion. LED lighting offers the opportunity to address all of these - to "have it all". The article will be published in the August edition of Lighting Design and Application (LD&A) magazine.

LED Lighting, Efficacy, Lighting Quality, Connecte↗