Search NASA⌕ Search

SEARCH · Search NASA

Results for “contactless sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Geolocation tracking for human identification and activity recognition using radar deep transfer learning

Abstract Human identification and activity recognition (HIAR) is crucial for many applications, such as surveillance, smart homes, and assisted living. As a sensing modality, radar has many unique characteristics including privacy protection, and contactless sensing. Single classification systems have shown to be accurate, but for long‐term solutions both human identification (ID) and human activity recognition (HAR) will need to be integrated in one system where it can be utilised simultaneously. In this article, a novel radar‐based human tracking system is presented where three classifiers are utilised to identify the subject and his/her behaviour. For any kind of motion, the system tracks the subject and detect the type of his/her motion. Based on the detected type of motion, the three classifiers are utilised for identification and activity recognition. The classifiers are built utilising deep transfer learning where three radar datasets are established to train and validate each of the deep networks. To recognise six activities and 10 human subjects, the three classifiers, namely, HAR, Gait ID, and Heart sound ID, achieve superior performance compared to the best reported results in literature with classification accuracies of 97.6%, 100%, and 41.8% respectively. Three successful examples are presented to demonstrate the introduced concept.

Alkasimi, Ahmad↗

Enhanced Machine-Learning Flow for Microwave-Sensing Systems for Contaminant Detection in Food

The presence of foreign bodies in packaged food is a serious concern for both fnal consumers (allergies, injuries, choking) and food manufacturers (reputation and economic losses). In particular, low-density plastics, glass and wood splinters are hard to detect even by the most advanced X-ray imagers. One solution is Machine-Learning-based Microwave Sensing (MLMWS): a non-invasive, contactless, and real-time method which uses a machine-learning (ML) classifer to analyze the scattered microwaves from the irradiated target object. In this paper, we want to extend our previous work about contaminant detection in cocoa-hazelnut spread jars by proposing an enhanced ML flow to increase the accuracy of the ML classifier. For the first time in this case study, we use a multi-class classifier, we train it with scattering parameters measured at multiple microwave frequencies, with a new pre-processing scaler, data augmentation, quantization-aware training and a pruning schedule. The results show a contaminant detection multi-class accuracy of 94.167% with a latency of 26 µs when targeting an AMD/Xilinx Kria K26 FPGA. Finally, we released our datasets publicly to OpenML.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resonance-induced sensitivity enhancement method for conductivity sensors

Methods and systems for improving the sensitivity of a variety of conductivity sensing devices, in particular capacitively-coupled contactless conductivity detectors. A parallel inductor is added to the conductivity sensor. The sensor with the parallel inductor is operated at a resonant frequency of the equivalent circuit model. At the resonant frequency, parasitic capacitances that are either in series or in parallel with the conductance (and possibly a series resistance) is substantially removed from the equivalent circuit, leaving a purely resistive impedance. An appreciably higher sensor sensitivity results. Experimental verification shows that sensitivity improvements of the order of 10,000-fold are possible. Examples of detecting particulates with high precision by application of the apparatus and methods of operation are described.

Tai, Yu-Chong↗

Contactless conductivity detector for microchip capillary electrophoresis

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.

NASA Center JPL↗

Advanced Measurement Devices for the Microgravity Electromagnetic Levitation Facility EML

This paper reports on two advanced measurement devices for the microgravity electromagnetic levitation facility (EML), which is currently under construction for the use onboard the "International Space Station (ISS)": the "Sample Coupling Electronics (SCE)" and the "Oxygen Sensing and Control Unit (OSC)". The SCE measures by a contactless, inductive method the electrical resistivity and the diameter of a spherical levitated metallic droplet by evaluating the voltage and electrical current applied to the levitation coil. The necessity of the OSC comes from the insight that properties like surface tension or, eventually, viscosity cannot seriously be determined by the oscillating drop method in the EML facility without knowing the conditions of the surrounding atmosphere. In the following both measurement devices are explained and laboratory test results are presented.

Brillo, Jurgen↗

Using Fiducial Markers for Pose Estimation of an OSWEC in a Wave Tank: Preprint

In this study, we consider a novel method of sensing the motion of a wave energy converter during testing in a wave flume under the influence of incoming waves. The wave energy converter considered in our research is an oscillating surge wave energy converter, which is a hinged paddle that responds to incoming waves. Motion sensing is normally done with inertial sensors, which can hinder the motion due to suspended cables that carry power and transmit signals. Our proposed method is contactless and can be implemented economically. A camera is used to record different marker patterns affixed to the moving paddle and the motion deduced by pose estimation algorithms. Fiducial markers are commonly used for robot localization and in augmented reality. There are many types of fiducial markers, including ArUco-type markers which are accurate, fast and robust. The system consists of markers attached to the paddle element and recorded using a machine vision camera. A pose estimation algorithm is then applied to the detected markers to estimate the tilt of the paddle. In this work, we examine the challenges of image acquisition and calibration for underwater targets, compare the motion obtained by this new system with a calibrated tilt sensor and identify areas where the new system may be superior.

computer vision↗

Advancing Industry 4.0: Multimodal Sensor Fusion for AI-Based Fault Detection in 3D Printing

Additive manufacturing, particularly fused deposition modeling, is transforming modern production by enabling rapid prototyping and complex part fabrication. However, its layer-by-layer process remains vulnerable to faults such as nozzle clogging, filament runout, and layer misalignment, which compromise print quality and reliability. Traditional inspection methods are costly, time-intensive, and often limited to post-process analysis, making them unsuitable for real-time intervention. In this current study, the authors developed a novel, low-cost, and portable faultdetection system that leverages multimodal sensor fusion and artificial intelligence for real-time monitoring in FDM-based 3D printing. The system integrates acoustic, vibration, and thermal sensing into a non-intrusive architecture, capturing complementary data streams that reflect both mechanical and process-related anomalies. Acoustic and thermal sensors operate in a fully contactless manner, while the vibration sensor requires minimal attachment such that it will not interfere with printer hardware, thereby preserving portability and ease of deployment. The multimodal signals are processed into spectrograms and time-frequency features, which are classified using convolutional neural networks for intelligent fault detection. The proposed system advances Industry 4.0 objectives by offering an affordable, scalable, and practical monitoring solution that improves faultdetection accuracy, reduces waste, and supports sustainable, adaptive manufacturing.

42 ENGINEERING↗

Ionically Active MXene Nanopore Actuators

Reversible electrochemical intercalation of cations into the interlayer space of 2D materials induces tunable physical and chemical properties in them. In MXenes, a large class of recently developed 2D carbides and nitrides, low intercalation energy, high storage capacitance, and reversible intercalation of various cations have led to their improved performance in sensing and energy storage applications. In this work, a coupled nanopore-actuator system where an ultrathin free-standing MXene film serves as a nanopore support membrane and ionically active actuator is reported. In this system, the contactless MXene membrane in the electric field affects the cation movement in the field through their (de)intercalation between individual MXene flakes. This results in reversible swelling and contraction of the membrane monitored by ionic conductance through the nanopore. This unique nanopore coupled to a mechanical actuation system could provide new insights into designing single-molecule biosensing platforms at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete

Abstract Although contactless ultrasonic wavefield imaging shows potential for effective nondestructive inspection of various engineering materials, it has been rarely applied to concrete materials owing to technical challenges including low signal-to-noise ratio (SNR) caused by inherent heterogeneity of concrete. This paper presents development of a multi-channel MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete materials. The developed multi-channel MEMS ultrasonic microphone array system contains eight MEMS ultrasonic microphone elements and a signal conditioning circuit that enables measurements of ultrasonic signals with high SNR. A compressed sensing approach, based on the multiple measurement vector (MMV) concept, is applied to reconstruct a full dense ultrasonic wavefield data from sparsely sampled ultrasonic wavefield data. Experiments are carried out on a laboratory concrete sample to verify the performance of the developed MEMS microphone array system and proposed compressed sensing approach and then large-scale concrete samples to demonstrate practical application. The experimental results demonstrate that the developed MEMS microphone array system provides high-quality (SNR > 20 dB) ultrasonic data collected from concrete elements; furthermore, the proposed compressed sensing approach provides accurate reconstruction of dense wavefield data, as determined by peak signal-to-noise ratio (PSNR), from sparsely measured wavefield data with compression ratios up to 85% and PSNR above 25 dB in data collected form realistic large-scale concrete samples. By combining the MEMS array system and compressed sensing approach, the total ultrasonic data acquisition time needed to produce dense wavefield data can be significantly reduced.

Instruments & Instrumentation↗