Search NASA⌕ Search

SEARCH · Search NASA

Results for “contamination control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Permanent Foam Fixatives for Radioactive Contamination Control: Environmental Chamber Testing

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with closing cleanup sites throughout the DOE-EM complex. A major component of successfully closing the sites is the deactivation and decommissioning (D&D) of radioactively contaminated buildings in nuclear facilities. Deactivation consists of the process of placing a contaminated facility in stable condition in order to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning consists of leaving the buildings in an agreed upon end state to provide future protection against hazards. Hazards include radiation but can also include asbestos, polychlorinated biphenyls, and other environmental and physical hazards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling Bacterial Contamination During Fuel Ethanol Fermentation Using Thermochemically Depolymerized Lignin Bio-Oils

Lactic acid bacteria (LAB) contamination during fuel ethanol fermentation can lead to significant economic loses. To circumvent this, fuel ethanol plants add antibiotics prophylactically, but their overuse has resulted in the emergence of antibiotic-resistant LAB strains. Lignin is a sustainable biopolymer that can be found as a waste product from lignocellulosic biorefineries. Technical lignins and their smaller phenolic subunits have been shown to exhibit broad-spectrum antimicrobial properties, but there is a lack of demonstrations of lignin derivatives with highly selective properties in the literature. Here, corn stover lignin from a biorefinery was oxidatively depolymerized using an environmentally benign organic oxidant, peracetic acid, into a bio-oil that has selective antimicrobial properties against LAB and not yeasts. The resulting bio-oil demonstrated up to 90% inhibition of commercially sampled LAB (including antibiotic-resistant strains) at 4 mg ml-1 with no inhibition against an industrial yeast strain. These antimicrobial properties of the bio-oil are attributed to larger unidentified lignin oligomers, compared to monolignols, that have a membrane damaging mode of action. Using the bio-oil (4 mg ml-1) during simultaneous saccharification and fermentation (SSF) of raw corn starch showed no inhibition of enzymatic activity, and in LAB contaminated fermentations the bio-oil treatments showed an 8% increase in ethanol yields at higher bacterial contamination ratios (l : 100 yeast to LAB, CFU per ml). This study illustrates the efficacy of using lignin bio-oil as an antibiotic replacement during fuel ethanol fermentation and demonstrates the highly selective antimicrobial properties of lignin oligomers, which creates a viable lignin valorization strategy for biorefineries.

bio-oil↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

National Ignition Facility. Facility and Infrastructure Systems Maintenance Plan

Ensuring the reliability of the NIF, including its support systems, laser systems, target diagnostic systems, and utilities, is essential to the availability of the NIF in its support of NNSA missions. NIF is a key capability in the DOE Stockpile Stewardship Program and supports high energy physics experiments for nuclear weapons, energy, and astrophysics applications. High system reliability provides opportunities for shots and scientific discoveries with opportunities to enhance and upgrade capabilities. This Maintenance Plan (MP) identifies the policies and procedures used to perform and support asset management of the NIF Facility and Infrastructure Systems (FInS), NIF Lasers & Alignment (LASE), NIF Target Experimental Operations (TOPS), NIF Target Area Science and Engineering (TASE), and NIF&PS Control Systems (NCS). The FInS systems include the facility, HVAC, contamination control, beampath, and Line Replaceable Units (LRUs) as well as utilities which create the beampath environments, such as vacuum, argon, or clean dry air. The LASE systems are Programmatic systems which include laser diagnostics, alignment, power conditioning, pulsed power, and input laser systems. The TOPS and TASE systems are also Programmatic systems which include target and diagnostic delivery systems and positioners, many different insertable and fixed target diagnostics, and cryogenic and target gas fill systems. Finally, the NCS systems include both software and hardware for industrial and shot operation control systems. Policies governing administrative and operational practices related to maintenance of FInS, LASE, TOPS, TASE, and NCS systems are described in this plan. In addition, the plan provides processes and procedures for managing, tracking, and documenting the work. This document, the NIF Operations Management Plan, NIF-5020544 (Ref. 1), and NIF Shot Operations Plan, NIF-5018506 (Ref. 2), together satisfy the requirements of the Conduct of Operations. Duties, responsibilities, and reporting requirements of the various positions associated with FInS, LASE, and TOPS maintenance are detailed in this plan. The FInS systems include both Real Property systems with asset management requirements specified in DOE Order 430.1C (Ref. 3) and Programmatic systems. In addition, for FInS, there is a list of the System Level Maintenance Plans (SLMPs) in NIF-1007419198 (Ref. 4) which provide the system descriptions and maintenance plan and schedule. In addition, the list includes the Reliability Centered Maintenance (RCM) and Experience Centered Maintenance (ECM) evaluations that have been performed for applicable FInS systems as well as reliability criticality per Section 3.5. The -AM version of the NIF Maintenance Plan focuses on the reliability program for FInS, LASE, TOPS, TASE, and NCS within the context of the overall NIF Reliability, Availability, and Maintainability (RAM) program and incorporates changes since the -AL version from August 2011 and has been updated to be fully consistent with the updates to Ref. 1. It also includes asset management considerations, updates to the Work Order (WO) process within the NIF Computerized Maintenance Management System (CMMS) which is EAM infor® System Maintenance and Reliability Tracking (SMaRT) (Ref. 5), and updates to metrics and key performance indicators (KPIs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nuclear Decontamination Evolution and Revolution - 20349

Decontamination, one of the oldest practices in the nuclear industry, is about to change. While no single approach to decontamination is appropriate in all situations, decontamination of highly contaminated surfaces is historically viewed as difficult and/or marginally effective and fixatives and strippable coatings are often called on to manage time sensitive contamination control issues. The deferral of proper decontamination can lead to accumulated concentrations of radioactive material increasing the risk of cross-contamination of workers and equipment while also increasing radiation levels, which further discourages decontamination. The results of the subject testing demonstrate that superior decontamination factors are readily achievable and the ALARA benefit of decontamination is viable through advanced decontamination technologies in conjunction with innovative application techniques. The collateral benefits will save countless radiological man-hours and personnel radiological exposure. The appropriate use of radiological decontamination techniques can prevent or limit the adverse effects of highly radioactive contamination in the work area. High levels of radiological contamination are typically associated with some of the most physically demanding work in the nuclear industry. Additionally, working in highly contaminated environments increases the risk of exposure to elevated levels of airborne radioactivity and radiation from the source term of the contamination, particularly in hard to reach areas or complex equipment. Veolia's Alaron Nuclear Services (Alaron), a fully integrated nuclear facility, has provided the nuclear industry waste treatment, consolidation, repackaging, and broad decontamination services for almost 35 years. In looking at solutions for its customers, as well as for their own facility, Alaron has recently collaborated with Environmental Alternatives, Inc. (EAI), which has provided innovative solutions addressing difficult nuclear decontamination and industrial cleaning challenges since 1989. This broad range of experience along with the products to support the work created an ideal partner for Alaron's needs at their facility. The benefits of collaboration were immediately recognizable to the management of both companies although the decontamination challenge was significant. Due to the nature of the services offered, contamination at the Alaron facility is routine. The recent decontamination experience at Alaron utilized an innovative surfactant process that quickly produces remarkably higher decontamination factors for both removable surface contamination and fixed contamination. Considering the time to decontaminate areas historically designated for high radiological hazard work, the results from this decontamination effort not only reduced contamination levels but also significantly lowered exposure rates in the working environment. The relative ease with which the surfactant is applied, combined with extraordinary decontamination test results, indicates the potential to alter current radiological work processes in a way that improves worker comfort, and removes radiological engineering barriers, allowing Alaron to complete complex radiological tasks more efficiently and effectively. In a series of two simple applications of the decontamination agent to contaminated high bay vertical surfaces, as well as a variety of horizontal and vertical surfaces with variable porousness and surface sealants, there was an overall reduction in removable contamination of approximately 73% with a reduction in area dose of approximately 93%. The results indicate additional reduction in fixed contamination with application of the surfactant. These values are much higher than experienced with more traditional decontamination agents. In conjunction with demonstrating EAI's surfactant on room surfaces, additional studies were conducted on complex geometry equipment including waste processing equipment, tools, and heavily contaminated parts normally handled from Alaron's customers. Evaluations were made with straight application of EAI's surfactant as well as adding additional techniques to the treatment which afforded revolutionary improvements in the levels of contamination removed. Successful decontamination with up to 95% reduction in removable contamination with just one application were demonstrated in several of the trials. This paper outlines the planned approach to use this technology, the variety of surfaces and equipment treated, and the results of the decontamination efforts. Furthermore, this paper discusses options for pretreatment of certain heavily contaminated equipment prior to employees handling and/or working with the equipment. The potential for dose saving and the reduced risk of cross-contamination with the added benefit of lower PPE requirements, produces an enormous potential for cost and time savings. Attendees will benefit from Alaron's experiences and more fully understand the capabilities of EAI's decontamination process. With the variety of contamination agents, forms and surfaces on which the technology was demonstrated, the information will be valuable to a broad cross-section of industry users. The significance of this report demonstrates superior decontamination factors are achievable utilizing the next evolution of decontamination technology and that the ALARA benefits of decontamination are available through advanced and modern decontamination efforts. The collateral benefits will save countless radiological man-hours and valuable personnel radiological exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas delivery system for environmental transmission electron microscope

A portable, compact gas delivery system can support an environmental transmission electron microscope. Environment transmission electron microscopy provides researchers a unique capability of assessing a material's surface conditions at atomic resolution in a variety of reactive and oxidizing environments. The ability to precisely control the analysis chamber's environmental conditions over time is key to the success of a typical surface analysis. The gas delivery system provides the correct balance or pressure delivery precision, contamination control, and gas isolation.

Nogan, John Joseph↗

Are light curve classification metrics good proxies for SN Ia cosmological constraining power?

Context. When selecting a light curve classifier for use as part of a photometric supernova Ia (SN Ia) cosmological analysis, it is common to make decisions based on metrics of classification performance, such as the contamination within the photometrically classified SN Ia sample, rather than a measure of cosmological constraining power. If the former is an appropriate proxy for the latter, this practice would eliminate the computational expense of a full cosmology forecast in the analysis pipeline design process. Aims. This study tests the assumption that light curve classification metrics are an appropriate proxy for cosmology metrics. Methods. We emulated photometric SN Ia cosmology light curve samples with controlled contamination rates of individual contaminant classes and evaluated each of them under a set of classification metrics. We then derived cosmological parameter constraints from all samples under two common analysis approaches and quantified the impact of contamination by each contaminant class on the resulting cosmological parameter estimates. Results. We observe that cosmology metrics are sensitive to both the contamination rate and the class of the contaminating population, whereas the classification metrics are shown to be insensitive to the latter. Conclusions. Based on these findings, we discourage any exclusive reliance on light curve classification-based metrics for analysis design decisions, which (counterintuitively) include but are not limited to the classifier choice. Instead, we recommend optimising science analysis pipeline design choices using a metric of the information gained about the physical parameters of interest.

79 ASTRONOMY AND ASTROPHYSICS↗

Sulfur Loading and Speciation Control the Hydrophobicity, Electron Transfer, Reactivity, and Selectivity of Sulfidized Nanoscale Zerovalent Iron

Sulfidized nanoscale zerovalent iron (SNZVI) is a promising material for groundwater remediation. However, the relationships between sulfur content and speciation and the properties of SNZVI materials are unknown, preventing rational design. Here, the effects of sulfur on the crystalline structure, hydrophobicity, sulfur speciation, corrosion potential, and electron transfer resistance are determined. Sulfur incorporation extended the nano-Fe 0 BCC lattice parameter, reduced the Fe local vacancies, and lowered the resistance to electron transfer. Impacts of the main sulfur species (FeS and FeS 2 ) on hydrophobicity (water contact angles) are consistent with density functional theory calculations for these FeS x phases. These properties well explain the reactivity and selectivity of SNZVI during the reductive dechlorination of trichloroethylene (TCE), a hydrophobic groundwater contaminant. Controlling the amount and speciation of sulfur in the SNZVI made it highly reactive (up to 0.41 L m -2 d -1 ) and selective for TCE degradation over water (up to 240 moles TCE per mole H 2 O), with an electron efficiency of up to 70%, and these values are 54-fold, 98-fold, and 160-fold higher than for NZVI, respectively. These findings can guide the rational design of robust SNZVI with properties tailored for specific application scenarios.

36 MATERIALS SCIENCE↗

Toward real-time optimization through model reduction and model discrepancy sensitivities

Optimization problems arise in a range of scenarios, from optimal control to model parameter estimation. In many applications, such as the development of digital twins, it is essential to solve these optimization problems within wall-clock-time limitations. However, this is often unattainable for complex systems, such as those modeled by nonlinear partial differential equations. One strategy for mitigating this issue is to construct a reduced-order model (ROM) that enables more rapid optimization. In particular, the use of nonintrusive ROMs—those that do not require access to the full-order model at evaluation time—is popular because they facilitate the computation of optimization solutions within the wall-clock time requirements. However, the optimization solution will be unreliable if the iterates move outside the ROM training data. This article proposes the use of hyper-differential sensitivity analysis with respect to model discrepancy (HDSA-MD) as a computationally efficient tool to augment ROM-constrained optimization and improve its reliability. The proposed approach consists of two phases: (i) an offline phase where several full-order model evaluations are computed to train the ROM, and (ii) an online phase where a ROM-constrained optimization problem is solved, a limited number of full-order model evaluations are computed, and HDSA-MD is used to enhance the optimization solution. Numerical results are demonstrated for two examples, atmospheric contaminant control and wildfire ignition location estimation, in which a ROM is trained offline using inaccurate atmospheric data. In conclusion, the HDSA-MD update yields a significant improvement in the ROM-constrained optimization solution using only one full-order model evaluation online with corrected atmospheric data.

PDE-constrained optimization↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Physics and applications of dusty plasmas: The Perspectives 2023

Dusty plasmas are electrically quasi-neutral media that, along with electrons, ions, neutral gas, radiation, and electric and/or magnetic fields, also contain solid or liquid particles with sizes ranging from a few nanometers to a few micrometers. These media can be found in many natural environments as well as in various laboratory setups and industrial applications. As a separate branch of plasma physics, the field of dusty plasma physics was born in the beginning of 1990s at the intersection of the interests of the communities investigating astrophysical and technological plasmas. An additional boost to the development of the field was given by the discovery of plasma crystals leading to a series of microgravity experiments of which the purpose was to investigate generic phenomena in condensed matter physics using strongly coupled complex (dusty) plasmas as model systems. Finally, the field has gained an increasing amount of attention due to its inevitable connection to the development of novel applications ranging from the synthesis of functional nanoparticles to nuclear fusion and from particle sensing and diagnostics to nano-contamination control. The purpose of the present perspectives paper is to identify promising new developments and research directions for the field. As such, dusty plasmas are considered in their entire variety: from classical low-pressure noble-gas dusty discharges to atmospheric pressure plasmas with aerosols and from rarefied astrophysical plasmas to dense plasmas in nuclear fusion devices. Both fundamental and application aspects are covered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atacama Cosmology Telescope: Component-separated maps of CMB temperature and the thermal Sunyaev-Zel’dovich effect

Optimal analyses of many signals in the cosmic microwave background (CMB) require map-level extraction of individual components in the microwave sky, rather than measurements at the power spectrum level alone. To date, nearly all map-level component separation in CMB analyses has been performed exclusively using satellite data. In this paper, we implement a component separation method based on the internal linear combination (ILC) approach which we have designed to optimally account for the anisotropic noise (in the 2D Fourier domain) often found in ground-based CMB experiments. Using this method, we combine multi-frequency data from the Planck satellite and the Atacama Cosmology Telescope Polarimeter (ACTPol) to construct the first wide-area, arcminute-resolution component-separated maps (≈ 2100 sq. deg.) of the CMB temperature anisotropy and the thermal Sunyaev-Zel'dovich (tSZ) effect sourced by the inverse-Compton scattering of CMB photons off hot, ionized gas. Our ILC pipeline allows for explicit deprojection of various contaminating signals, including a modified blackbody approximation of the cosmic infrared background (CIB) spectral energy distribution. The cleaned CMB maps will be a useful resource for CMB lensing reconstruction, kinematic SZ cross-correlations, and primordial non-Gaussianity studies. Here, the tSZ maps will be used to study the pressure profiles of galaxies, groups, and clusters through cross-correlations with halo catalogs, with dust contamination controlled via CIB deprojection. The data products described in this paper are available on LAMBDA.

79 ASTRONOMY AND ASTROPHYSICS↗

Biomineralization of Cu 2 S Nanoparticles by Geobacter sulfurreducens

Biomineralization of Cu has been shown to control contaminant dynamics and transport in soils. However, very little is known about the role that subsurface microorganisms may play in the biogeochemical cycling of Cu. In this study, we investigate the bioreduction of Cu(II) by the subsurface metal-reducing bacterium Geobacter sulfurreducens. Rapid removal of Cu from solution was observed in cell suspensions of G. sulfurreducens when Cu(II) was supplied, while transmission electron microscopy (TEM) analyses showed the formation of electron-dense nanoparticles associated with the cell surface. Energy-dispersive X-ray spectroscopy (EDX) point analysis and EDX spectrum image maps revealed that the nanoparticles are rich in both Cu and S. This finding was confirmed by X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) analyses, which identified the nanoparticles as Cu 2 S. Biomineralization of Cu x S nanoparticles in soils has been reported to enhance the colloidal transport of a number of contaminants, including Pb, Cd, and Hg. However, formation of these Cu x S nanoparticles has only been observed under sulfate-reducing conditions and could not be repeated using isolates of implicated organisms. As G. sulfurreducens is unable to respire sulfate, and no reducible sulfur was supplied to the cells, these data suggest a novel mechanism for the biomineralization of Cu 2 S under anoxic conditions. The implications of these findings for the biogeochemical cycling of Cu and other metals as well as the green production of Cu catalysts are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Algal Biomass Yield Improvements in an Integrated Process (Final Report)

This project built on the success of Global Algae Innovations Algae Biomass Yield Phase 1 project to accelerate the commercialization of algal biofuels through development of an integrated, economical, photosynthetic, open raceway system to produce algal oil. Two parallel pathways to a biofuel were investigated. In the algal crude oil pathway, highlighted in blue, the dewatered algal biomass slurry is used as a feed to hydrothermal liquefaction to produce an algae crude oil and recycle aqueous stream. In the algal lipid oil pathway, highlighted in green, the algal biomass slurry is dried, and the oil is extracted to produce an algal lipid oil biofuel intermediate and a high protein algae meal co-product. Upgrading to drop-in fuels has been demonstrated for the biofuel intermediates in both pathways. Since the algal lipid oil pathway requires lipid accumulation, the productivity is generally lower than the algal crude oil pathway, but the required productivity for economical algal biofuel production is also lower because the coproduct value is greater. The outdoor cultivation was performed at the Kauai Algae Farm. The project team has expertise across the full breadth strain development, advanced algal cultivation, open raceway contamination control, CO 2 supply, harvesting, dewatering, extraction, hydrothermal liquefaction, technoeconomic analysis and life cycle analysis: Hildebrand laboratory at Scripps Institution of Oceanography – diatom strain development. Mayfield laboratory at UCSD - green algae strain development. TSD Management Associates- CO 2 supply, algal harvesting and dewatering, and algal drying and extraction. Qualitas - large-scale test site for algal harvesting technology. Texas A&M University - algal drying and extraction technology. Pacific Northwest National Laboratory - hydrothermal liquefaction technology. GE Water and Power - membrane technology. National Renewable Energy Laboratory - algal techno-economic analysis. Phase 1 of the project resulted in tremendous productivity and pre-processing improvements in an integrated, large-scale, low-cost cultivation and pre-processing process that moved algal technology closer to economic viability for biofuels than ever before. Phase 2 accomplishments further facilitate development of a commercial algal biofuel industry by adding: several top performing strains and strain development tools including breeding; open-pond cultivation innovations that achieved a 30% improvement in overall productivity, an 83% reduction in cost, and a 95% reduction in energy use relative to conventional technology; further improvements in harvesting that led to the Zobi harvester ® as a universal, economical, low energy, commercially available microalgae harvesting solution; breakthroughs in drying and extraction including a new low energy drying process and several new low energy extraction unit operations that together with the Zobi harvester ® achieve a 90% reduction in cost and 97% reduction in energy use relative to conventional technology. These improvements are sufficient to enable economical production of algae biofuel and protein meal co-product if the process were scaled up to a commercial-scale 5,000-acre algae farm.

09 BIOMASS FUELS↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory [Slides]

Sufficient AGN-201M fuel plate material exists at Y-12 to support the development of a new, inherently safe, subcritical assembly for use in NCS training courses at ORNL. Four experiments with the ORNL subcritical assembly are possible and feasible. Future work includes the final design of the core and reflector and split table component design specifications. The ORNL Material Demonstration Facility (MDF) may be used to 3D print ORSA stand/table components and graphite reflector. Researchers will consider fuel coatings for contamination control, rather than an Al can. A visit to Y-12 will be made to determine the location of AGN fuel plates and remaining fuel transportation considerations. Final facility location will be considered

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful sel ection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RCT Module 2.15 Radiological Considerations for First Aid [Presentation]

Standard first aid is applied before contamination control whenever it is considered to have life-saving value or is important to the patient for the relief of pain or prevention of disability. It is the obligation of all who assist a patient to render such aid within the limits of their training and qualifications.

61 RADIATION PROTECTION AND DOSIMETRY↗