Search NASA⌕ Search

SEARCH · Search NASA

Results for “content”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The oxygen content of the high-temperature superconducting compound Bi(2+x)Sr(3-y)CayCu2O(8+d) with respect to varying Ca and Bi contents

The oxygen content of Bi(2+x)Sr(3-y)Cu2O(8+d) (2212 phase) has been determined as a function of its cation concentration. With increasing Ca and Bi content the oxygen content increases and T(sub c) decreases. The oxygen content of Ca rich 2212 phase increases with decreasing annealing temperatures. The study shows that the T(sub c) of the 2212 phase primarily is controlled by its cation concentration.

Majewski, P.↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Effect of restricted mobility on RNA content and nucleotide composition and on protein content in motoneurons of spinal cord anterior horns

An investigation into the effect of hypokinesia on the ribonucleic acid (RNA) content, the nucleotide composition, and dynamics of protein content in the motoneuron of the rat spinal cord anterior horns is described. Methodology and findings are presented. The study results showed that the nucleotide composition of the total cellular RNA at all the studied periods of hypokinesia remained unchanged and is characteristic for the cytoplasmic, high polymer ribosomal RNA. This means that with a change in the functional state of the neuron the newly formed RNA of the nerve cell has the same composition of bases as the original RNA that belongs to the ribosomal type.

Gorbunova, A. V.↗

Relative water content of Spruce needles determined by the leaf water content index

Leaf relative water content (RWC) is defined as the volume of water in a leaf divided by the volume at full turgor. Using reflectance factors of wavelengths 0.83 micron and 1.6 microns, a Leaf Water Content Index (LWCI) was derived from the Lambert-Beer Law such that LWCI should equal RWC; LWCI was equal to RWC for Picea pungens, Picea rubens, Liquidambar styraciflua, and Quercus agrifolia. Algebraic manipulation shows that R(1.6)/R(0.83) termed the Moisture Stress Index (MSI), is near-linearly correlated to RWC and to the Equivalent Water Thickness (EWT). Five species tested so far had the same relationship between MSI and EWT, but EWT is not a measure of plant water status.

Hunt, E. Raymond, Jr.↗

Water Contents of the Mantle Beneath the Rio Grande Rift: FTIR Analysis of Kilbourne Hole Peridotite Xenoliths

Although nominally anhydrous mantle minerals contain only trace amounts of water, they are the main reservoir of water in the mantle. Added up at the scale of the Earth's mantle, these trace amounts of water represent oceans worth in mass]. Mantle xenoliths from Kilbourne Hole in southern New Mexico are ideal to study mantle water distribution in a rift tectonic setting as they come from a recently‐erupted maar in the middle of the Rio Grande Rift. Eleven lherzolites, one harzburgite, and one dunite are being analyzed for water contents by FTIR. The xenoliths will also be analyzed for major and trace element composition, Fe3+/Summation (Fe) ratios, and characterized petrologically. Olivines exhibit variable water contents with less water at the rims compared to the cores. This is probably due to H loss during decompression and xenolith transport by the host magma. Mantle water contents appear to have been primarily preserved in the core of the olivines, based on diffusion modeling of the typically plateau-shaped water content profiles across these grains. Water concentrations are in equilibrium between clino- and orthopyroxene, but olivine concentrations are typically not in equilibrium with those of either pyroxene. Lherzolites analyzed so far have water contents of 2‐12 ppm H2O in olivines, 125‐165 ppm H2O in orthopyroxenes, and 328‐447 ppm H2O in clinopyroxenes. These water contents are similar to, but with a narrower range, than those for the respective minerals in other continental peridotite xenoliths. The lherzolites have bulk-rock (BR) Al2O3 contents that range between 3.17 and 3.78 wt%, indicating similar degrees of partial melting, which could explain the narrow range of their pyroxene water contents. Primitive mantle normalized rare earth element (REE) profiles of the bulk lherzolites vary from light REE depleted to flat, with no significant differences between, nor relation to, their mineral water contents. Consequently, the metasomatic agents that enriched LREEs in these lherzolites were most likely water-poor. The harzburgite and the dunite have lower weight percent Al2O3 compared to the lherzolites (2.11% and 0.34% respectively) indicating higher degrees of melting. Their olivine water contents, however, are similar to those of the lherzolites. Moreover, no correlations are observed between pyroxene water contents and indices of melting or metasomatism between the lherzolite group, the harzburgite, and the dunite, although the latter has the lowest pyroxene water contents. More samples will be analyzed to determine if the water contents are controlled by melting, metasomatism, or a combination of the two in the Kilbourne Hole mantle.

Schaffer, Lillian A.↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector concave total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the Isokinetic Probe version 2 (IKP2), which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window probes to the measurements made with the underwing and nose probes. The key findings were: (1) the Ice Crystal Detector concave water content sensor efficiency factor to glaciated conditions was similar to previous estimates, but reduced with increased ice crystal median mass diameter; (2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values—although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and (3) the ice water content at the 17 in. standoff from the port window varied from about 50 percent to nearly three times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Measurement of leaf relative water content by infrared reflectance

From basic considerations and Beer's law, a leaf water content index incorporating reflectances of wavelengths from 0.76 to 0.90 microns and from 1.55 to 1.75 microns was developed that relates leaf reflectance to leaf relative water content. For the leaf succulent, Agave deserti, the leaf water content index was not significantly different from the relative water content for either individual leaves or an entire plant. Also, the relative water contents of intact plants of Encelia farinosa and Hilaria rigida in the field were estimated by the leaf water content index; variations in the proportion of living to dead leaf area could cause large errors in the estimate of relative water content. Thus, the leaf water content index may be able to estimate average relative water content of canopies when TM4 and TM5 are measured at a known relative water content and fraction of dead leaf material.

Hunt, E. Raymond, Jr.↗

Water content and the conversion of phytochrome regulation of lettuce dormancy

In an effort to determine which biological reactions can occur in relation to the water content of seeds, the regulation of lettuce seed dormancy by red and far red light was determined at various hydration levels. Far red light had an inhibiting effect on germination for seeds at all moisture contents from 4 to 32% water. Germination was progressively stimulated by red light as seed hydration increased from 8 to 15%, and reached a maximum at moisture contents above 18%. Red light was ineffective at moisture contents below 8%. Seeds that had been stimulated by red light and subsequently dried lost the enhanced germinability if stored at moisture contents above 8%. The contrast between the presumed photoconversion of phytochrome far red-absorbing (Pfr) to (Pr) occurring at any moisture content and the reverse reaction occurring only if the seed moisture content is greater than 8% may be explained on the basis of the existence of unstable intermediates in the Pr to Pfr conversion. Our results suggest that the initial photoreaction involved in phytochrome conversion is relatively independent of water content, while the subsequent partial reactions become increasingly facilitated as water content increases from 8 to 18%.

Non-NASA Center↗

Estimation of the oxalate content of foods and daily oxalate intake

BACKGROUND: The amount of oxalate ingested may be an important risk factor in the development of idiopathic calcium oxalate nephrolithiasis. Reliable food tables listing the oxalate content of foods are currently not available. The aim of this research was to develop an accurate and reliable method to measure the food content of oxalate. METHODS: Capillary electrophoresis (CE) and ion chromatography (IC) were compared as direct techniques for the estimation of the oxalate content of foods. Foods were thoroughly homogenized in acid, heat extracted, and clarified by centrifugation and filtration before dilution in water for analysis. Five individuals consuming self-selected diets maintained food records for three days to determine their mean daily oxalate intakes. RESULTS: Both techniques were capable of adequately measuring the oxalate in foods with a significant oxalate content. With foods of very low oxalate content (<1.8 mg/100 g), IC was more reliable than CE. The mean daily intake of oxalate by the five individuals tested was 152 +/- 83 mg, ranging from 44 to 352 mg/day. CONCLUSIONS: CE appears to be the method of choice over IC for estimating the oxalate content of foods with a medium (>10 mg/100 g) to high oxalate content due to a faster analysis time and lower running costs, whereas IC may be better suited for the analysis of foods with a low oxalate content. Accurate estimates of the oxalate content of foods should permit the role of dietary oxalate in urinary oxalate excretion and stone formation to be clarified. Other factors, apart from the amount of oxalate ingested, appear to exert a major influence over the amount of oxalate excreted in the urine.

NASA Discipline Regulatory Physiology↗

Protonospheric columnar electron content determination. II - Observations

The results of over 300 hours of measurements of the quantity I sub w - the difference between total columnar electron content, derived from the differential phase-path data, and Faraday electron content - is presented. The interpretation of the measurements in terms of protonospheric content is discussed in the light of a previous analysis which demonstrates that good protonospheric content measurements can only be obtained under certain geometries of observations unless information on the shape and height of the ionospheric layer is available. A strong correlation between I sub w and the ionospheric content is observed in most of the Arecibo data, because they were collected under unfavorable conditions. The Stanford data, on the other hand, yield good measurements of the protonospheric content. The May 1969 observations show a strong depletion of protonospheric content during a magnetic storm and its subsequent recovery. This is in general agreement with flux tube content behavior observed by the whistler technique during similar conditions.

Almeida, O. G.↗

A scheme for parameterizing ice-cloud water content in general circulation models

The optical properties of ice clouds are a primary issue for climate and climate change. Evaluating these optical properties in three-dimensional models for studying climate will require a method to calculate the ice water content of such clouds. A procedure is developed to parameterize ice water content as a function of large-scale meteorological characteristics for use in circulation models in which the ice water content is not calculated by means of a three-dimensional prognostic equation for condensed water. The technique identifies large-scale flows in which ice clouds exist and calculates their ice water content by reconstructing the trajectory associated with cloud formation. As the cloud forms, its ice content changes both by deposition of ice from water vapor and by ice removal by sedimentation. The sedimentation process is found to modify significantly the ice water content expected from deposition alone. Ice water contents predicted by the parameterization are compared with aircraft observations collected in the middle latitudes and the tropics, and show reasonable agreement over four orders-of-magnitude of ice water content. A parameterization for the sublimation of ice crystals settling into ice-subsaturated environments is also presented.

Heymsfield, Andrew J.↗

Ice Particle Impact on Cloud Water Content Instrumentation

Determining the total amount of water contained in an icing cloud necessitates the measurement of both the liquid droplets and ice particles. One commonly accepted method for measuring cloud water content utilizes a hot wire sensing element, which is maintained at a constant temperature. In this approach, the cloud water content is equated with the power required to keep the sense element at a constant temperature. This method inherently assumes that impinging cloud particles remain on the sensing element surface long enough to be evaporated. In the case of ice particles, this assumption requires that the particles do not bounce off the surface after impact. Recent tests aimed at characterizing ice particle impact on a thermally heated wing section, have raised questions about the validity of this assumption. Ice particles were observed to bounce off the heated wing section a very high percentage of the time. This result could have implications for Total Water Content sensors which are designed to capture ice particles, and thus do not account for bouncing or breakup of ice particles. Based on these results, a test was conducted to investigate ice particle impact on the sensing elements of the following hot-wire cloud water content probes: (1) Nevzorov Total Water Content (TWC)/Liquid Water Content (LWC) probe, (2) Science Engineering Associates TWC probe, and (3) Particle Measuring Systems King probe. Close-up video imaging was used to study ice particle impact on the sensing element of each probe. The measured water content from each probe was also determined for each cloud condition. This paper will present results from this investigation and attempt to evaluate the significance of ice particle impact on hot-wire cloud water content measurements.

Emery, Edward F.↗

Determination of aerosol content in the atmosphere from ERTS-1 data

The author has identified the following significant results. Significant results, relating the radiance over water surfaces to the atmospheric aerosol content, have been obtained. The results indicate that the MSS channels 4, 5, and 6 centered at 0.55, 0.65, and 0.75 microns have comparable sensitivity, and that the aerosol content can be determined within + or - 10% with the assumed measurement errors of the MSS. The fourth channel, MSS 7, is not useful for aerosol determination due to the water radiance values from this channel generally being less than the instrument noise. The accuracy of the aerosol content measurement could be increased by using an instrument specifically designed for this purpose. This radiance-aerosol content relationship can possibly provide a basis for monitoring the atmospheric aerosol content on a global basis, allowing a base-line value of aerosols to be established. The contrast-aerosol content investigation shows useful linear relationships in MSS channels 4 and 5, allowing the aerosol content to be determined within + or - 10%. MSS 7 is not useful due to the low accuracy in the water radiance, and MSS 6 is found to be too insensitive. These results rely on several assumptions due to the lack of ground truth data, but do serve to indicate which channels are most useful.

Griggs, M.↗

Exploring the Relationship Between Reflectance Red Edge and Chlorophyll Content in Slash Pine

Chlorophyll is a key indicator of the physiological status of a forest canopy. However, its distribution may vary greatly in time and space, so that the estimation of chlorophyll content of canopies or branches by extrapolation from leaf values obtained by destructive sampling is labor intensive and potentially inaccurate. Chlorophy11 content is related positively to the point of maximum slope in vegetation reflectance spectra which occurs at wavelengths between 690-740 nm and is known as the "red edge." The red edge of needles on individual slash pine (Piniis elliottii Engelm.) branches and in whole forest canopies was measured with a spectroradiometer. Branches were measured on the ground against a spectrally flat reflectance target and canopies were measured from observation towers against a spectrally variable understory and forest floor. There was a linear relationship between red edge and chlorophyll content of branches (R(exp 2) = 0.91). Measurements of the red edge and this relationship were used to estimate the chlorophyll content of other branches with an error that was lower than that associated with the colorimetric (laboratory) method. There was no relationship between the red edge and the chlorophyll content of whole canopies. This can be explained by the overriding influence of the understory and forest floor, an influence that was illustrated by spectral mixture modeling. The results suggest that the red edge could be used to estimate the chlorophyll content in branches but it is unlikely to be of value for the estimation of chlorophyll content in canopies unless the canopy cover is high.

Curran, Paul J.↗

Porous media matric potential and water content measurements during parabolic flight

Control of water and air in the root zone of plants remains a challenge in the microgravity environment of space. Due to limited flight opportunities, research aimed at resolving microgravity porous media fluid dynamics must often be conducted on Earth. The NASA KC-135 reduced gravity flight program offers an opportunity for Earth-based researchers to study physical processes in a variable gravity environment. The objectives of this study were to obtain measurements of water content and matric potential during the parabolic profile flown by the KC-135 aircraft. The flight profile provided 20-25 s of microgravity at the top of the parabola, while pulling 1.8 g at the bottom. The soil moisture sensors (Temperature and Moisture Acquisition System: Orbital Technologies, Madison, WI) used a heat-pulse method to indirectly estimate water content from heat dissipation. Tensiometers were constructed using a stainless steel porous cup with a pressure transducer and were used to measure the matric potential of the medium. The two types of sensors were placed at different depths in a substrate compartment filled with 1-2 mm Turface (calcined clay). The ability of the heat-pulse sensors to monitor overall changes in water content in the substrate compartment decreased with water content. Differences in measured water content data recorded at 0, 1, and 1.8 g were not significant. Tensiometer readings tracked pressure differences due to the hydrostatic force changes with variable gravity. The readings may have been affected by changes in cabin air pressure that occurred during each parabola. Tensiometer porous membrane conductivity (function of pore size) and fluid volume both influence response time. Porous media sample height and water content influence time-to-equilibrium, where shorter samples and higher water content achieve faster equilibrium. Further testing is needed to develop these sensors for space flight applications.

Parabolic Flight↗