Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuation power flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Hierarchical Distributed Optimal Power Flow of HV and MV Distribution Networks With Continuous and Discrete Devices

With large-scale distributed photovoltaics (PVs) being integrated into distribution networks (DNs), coordinated optimal power flow (OPF) of high voltage (HV) and medium voltage (MV) DNs should be investigated to optimally dispatch the distributed PVs and other network devices. Here, this paper presents a hierarchical distributed OPF method for HV and MV DNs with on-load tap changers, reactive power compensators, feeder switches and distributed PVs. A hierarchical master-slave control architecture is applied to implement coordinated OPF of two-layer DNs. The HV master problem and MV subproblems are transformed into mixed-integer convex problems respectively with second order cone programming and LinDistFlow approximation. Since there is no efficient distributed algorithm to solve such OPF models with integer subproblems, a novel distributed algorithm is proposed in this paper to efficiently solve the hierarchical coordinated OPF model with integer subproblems in a distributed manner. In the proposed algorithm, the coordinated OPF model is solved in a branch-and-bound framework, where in each branch node generalized Benders decomposition (GBD) algorithm is applied to decompose the coordinated OPF model into a master problem and relaxed subproblems and solves them iteratively to get optimal solution. The GBD optimal and feasible cutting planes generated in a branch node are proved to be valid for its descendants. Moreover, three acceleration techniques are introduced into the proposed algorithm to improve computational efficiency. Finally, the effectiveness and accuracy of the proposed method are verified via simulation tests in Jinzhai DNs of China.

42 ENGINEERING↗

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

An Assessment of Technical Hydropower Potential at Non-Powered Dams in the United States

Historically, dams have been constructed for a variety of purposes, such as providing a more secure and reliable water supply, mitigating impacts from variations in river flow, allowing continuous navigability, and harnessing mechanical power. A relatively small portion of dams have been designed to store or regulate flows for the purpose of generating electricity (roughly 3% of nationally inventoried dams in the US and 17% of the dams included in the World Register of Dams). The remaining population of existing non-powered dams (NPDs) presents both an opportunity to generate renewable energy and a need to modernize aging infrastructure. This report describes an assessment of more than 2,600 NPDs in the US that have a collective potential of nearly 4 GW in new power capacity. Previous national-scale assessments were aimed at evaluating the theoretical maximum power potential at existing dams in the United States. These estimates were based on the best available information at the time for water availability, hydraulic head, and representative regional capacity factors. This study revisits a subset of 3,299 dams identified in the most recent theoretical resource assessment and uses more detailed and updated hydrologic data to produce estimates of technical potential. These improvements in data enable estimates that more realistically reflect what is physically possible given simple assumptions about the existing structure and constraints on flow and head (Figure 1).

13 HYDRO ENERGY↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Scale-up of microwave-assisted, continuous flow, liquid phase reactors: Application to 5-Hydroxymethylfurfural production

Microwave (MW) technology can be powerful for the electrification and intensification of chemical manufacturing. However, very few examples of scaled MW processes exist. In this work, we build a scaled, MW-assisted, continuous flow reactor for the processing of liquid phase chemistries with specific application to 5-hydroxymethylfurfural (HMF) production. Here, we demonstrate a corresponding computational fluid dynamics model to simulate the reactor’s temperature profile and performance, both of which are in good agreement with experiments. We construct a surrogate model to relate operating parameters to performance for guiding experiments, without demanding simulations, via active learning. Heat recirculation is demonstrated in this scaled reactor, further extending its scale and reducing the energy demand. An HMF yield of ~55 % and a productivity of 0.1 kg/hr, 8x higher than any other reactor, at a flowrate >20x than prior work, are demonstrated while maintaining energy efficiency of >98 %. A basic economic analysis estimates a $1.85/kg cost of HMF from fructose and >60 % reduction in CO 2 emissions than a conventional system without considering the impact of green electricity. We demonstrate that MW technology is well-applied to systems larger than the laboratory scale, and strategies to further reduction in cost and CO 2 are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARPA-E Grid Optimization (GO) Competition Challenge 3

Synthetic Input Data and Team Results for the GO Competition Challenge 3 for Events 1 - 4 and the Sandbox, along with problem and format descriptions and code to validate data and solutions, are available here. Data for industry scenarios will not be made public. The Grid Optimization (GO) Competition Challenge 3 focused on the security-constrained optimal power flow (SCOPF) problem. It is part of a continuing effort begun with Challenges 1 and 2, to successfully discover, develop, and test innovative and disruptive software solutions for critical energy challenges and to overcome existing barriers. The broader goal of the of the GO Competition is to accelerate the development of transformational and disruptive methods for solving problems related to the electric power grid and to provide a transparent, fair, and comprehensive evaluation of new solution methods. Challenge 3 used multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. In Event 4, whose submission window was August 31-September 4, 2023, 14 teams solved for the objective values of 669 scenarios (39 scenarios required solutions both with and without line switching being allowed). The 591 synthetic scenarios from 9 network models (3.6 GB) are available here. Ten teams were funded to participate and 7 won prizes totaling $2,400,000. The largest prize ($550,000) went to Mississippi State University. An additional $600,000 was awarded in Event 3 (6/15-16/2023). No prizes were awarded in Events 1 (1/25-27/2023) or 2 (4/13-14/2023). For more information on the competition and challenge see the "GO Competition Challenge 3 Information" resource below.

ACOPF↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

QES-Plume v1.0: a Lagrangian dispersion model

Low-cost simulations providing accurate predictions of transport of airborne material in urban areas, vegetative canopies, and complex terrain are demanding because of the small-scale heterogeneity of the features influencing the mean flow and turbulence fields. Common models used to predict turbulent transport of passive scalars are based on the Lagrangian stochastic dispersion model. The Quick Environmental Simulation (QES) tool is a low-computational-cost framework developed to provide high-resolution wind and concentration fields in a variety of complex atmospheric-boundary-layer environments. Part of the framework, QES-Plume, is a Lagrangian dispersion code that uses a time-implicit integration scheme to solve the generalized Langevin equations which require mean flow and turbulence fields. Here, QES-Plume is driven by QES-Winds, a 3D fast-response model that computes mass-consistent wind fields around buildings, vegetation, and hills using empirical parameterizations, and QES-Turb, a local-mixing-length turbulence model. In this paper, the particle dispersion model is presented and validated against analytical solutions to examine QES-Plume’s performance under idealized conditions. In particular, QES-Plume is evaluated against a classical Gaussian plume model for an elevated continuous point-source release in uniform flow, the Lagrangian scaling of dispersion in isotropic turbulence, and a non-Gaussian plume model for an elevated continuous point-source release in a power-law boundary-layer flow. In these cases, QES-Plume yields a maximum relative error below 6 % when compared with analytical solutions. In addition, the model is tested against wind-tunnel data for a uniform array of cubical buildings. QES-Plume exhibits good agreement with the experiment with 99 % of matched zeros and 59 % of the predicted concentrations falling within a factor of 2 of the experimental concentrations. Furthermore, results also emphasize the importance of using high-quality turbulence models for particle dispersion in complex environments. Finally, QES-Plume demonstrates excellent computational performance.

58 GEOSCIENCES↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this paper, we discuss our design and demonstration of a water management strategy that supports high current and long cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water management approach is based on water vapor feeding in the hydrogen electrode, and water evaporation in the iron electrode, thus enabling the high current density operation of 300 mA cm −2 .

25 ENERGY STORAGE↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this article, we discuss our design and demonstration of a water‐management strategy that supports high current and long‐cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water‐management approach is based on water vapor feeding in the hydrogen electrode and water evaporation in the iron electrode, thus enabling high current density operation of 300 mA cm −2 .

Yan, Litao↗

Active liquid crystals powered by force-sensing DNA-motor clusters

Significance Single-molecule techniques have elucidated how isolated molecular motors generate piconewton forces with unprecedented detail. However, in diverse biological and synthetic settings, force-generating proteins collectively power nonequilibrium dynamics, including continuous large-scale rearrangements and persistent fluid flows. Characterizing motor-generated forces in these dense and dynamical environments remains a challenge. We assembled a reversible DNA-based force-sensing probe that, by an optical readout, reveals the molecular arrangements and the force loads experienced by kinesin motors. These probes provide insight into motor-generated forces that collectively power the unique dynamics of microtubule-based active nematics, a noteworthy example of an internally driven active matter system. DNA-based force probes can be extended to study forces and stresses in various synthetic systems as well as diverse cellular environments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Voltage Support With PV Inverters in Low-Voltage Distribution Networks: An Overview

Large solar photovoltaic (PV) penetration using inverters in low voltage (LV) distribution networks may pose several challenges, such as reverse power flow and voltage rise situations. These challenges will eventually force grid operators to carry out grid reinforcement to ensure continued safe and reliable operations. However, smart inverters with reactive power control capability enable PV systems to support voltage quality in the distribution network better. Here, this paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. In addition, the (control) technical issues of PV systems integrated into the LV distribution network are considered from a control point of view. By comparing the control issues of PV integration into the grid, the paper aims to help distribution system operators to expand the volume of PV generation in the distribution system in an efficient and safe manner. Additionally, it will help control engineers and researchers select proper control strategies for PV systems as well as other distributed renewable sources.

42 ENGINEERING↗