At least 19 records

Instrument continuously measures density of flowing fluids

Electromechanical densitometer continuously measures the densities of either single-phase or two-phase flowing cryogenic fluids. Measurement is made on actual flow. The instrument operates on the principle that the mass of any vibrating system is a primary factor in determining the dynamic characteristics of the system.

Jacobs, R. B.

A New Instrument for the Continuous Measurement of Condensation Nuclei

An instrument is described which provides a continuous measurement of airborne particle concentrations in the size range down to 0.00 1 microns. The concentration range of the instrument is from 10 to 10 (sup 7) particles per cubic centimeter with a response time in the order of 1 to 2 seconds. The Instrument is designed for continuous unattended operation and employs a unique dual beam, single phototube optical system in which the reference beam passes through the same optical elements as the measuring beam.

Skala, George F.

Continuous measurements of the total ozone content in the full moon period

Presented are the experimental data on the total ozone content obtained during continuous measurements (day-night-...-night-day) by Brewer 044 spectrophotometer near the Issyk Kul Lake (42.59N, 77.04W) at 1650 m above the sea level at full moon from 13 to 18 October 1989 under anomalously high transparent atmospheric conditions (the horizontal visibility range exceeded 50 km). At night the total O3 content decreased regularly to about 20 percent of the average daytime values. The minimum values at night were observed in 1-2 hours after the maximum solar dip below the horizon. In the daytime the measurements were carried out from direct Sun, at night - from the Moon. The values of the total ozone content for adjacent measurements from the Sun and from the Moon in the evening as well as in the morning are in good agreement.

Ishov, Alexander G.

Continuous Measurement Of Mass Density Of Yarn

Prototype instrument provides measurement data from which one computes mass density of strand of yarn. Includes fixtures placing known length of yarn under known tension across fixed and movable support. Transverse vibrations induced in yarn by moving movable support up and down. Source of light illuminates photodetector at midlength of yarn, and photodetector senses repeated shadowing caused by vibration of yarn through light, thereby measuring vibrations. Also used for continuous real-time monitoring of such yarn-manufacturing processes as coating or impregnation.

Hinkley, Jeffrey A.

Hamiltonian learning using machine-learning models trained with continuous measurements

Here, we build upon recent work on the use of machine-learning models to estimate Hamiltonian parameters using continuous weak measurement of qubits as input. We consider two settings for the training of our model: (1) supervised learning, where the weak-measurement training record can be labeled with known Hamiltonian parameters, and (2) unsupervised learning, where no labels are available. The first has the advantage of not requiring an explicit representation of the quantum state, thus potentially scaling very favorably to a larger number of qubits. The second requires the implementation of a physical model to map the Hamiltonian parameters to a measurement record, which we implement using an integrator of the physical model with a recurrent neural network to provide a model-free correction at every time step to account for small effects not captured by the physical model. We test our construction on a system of two qubits and demonstrate accurate prediction of multiple physical parameters in both the supervised context and the unsupervised context. We demonstrate that the model benefits from larger training sets, establishing that it is “learning,” and we show robustness regarding errors in the assumed physical model by achieving accurate parameter estimation in the presence of unanticipated single-particle relaxation.

97 MATHEMATICS AND COMPUTING

Mechanism continuously measures static and dynamic cable loads

Pulley mechanism measures the tensile loads on a cable under static and dynamic conditions, without disturbing the continuity of operation of the system. A set of takeoff pulleys are mounted on a pivoted frame that is linked to a strain gage which measures the frame displacement as a function of the static or dynamic tensile load on the cable.

Source record

Continuous measurement of aircraft wing icing

Ice formation on the wings of aircraft is a problem that has plagued air travel since its inception. Several recent incidents have been attributed to ice formation on the lifting surfaces of wings. This paper describes a SBIR Phase 1 research effort on the use of small flat dielectric sensors in detecting a layer of ice above the sensor. The sensors are very small, lightweight, and inexpensive. The electronics package that controls the sensor is also small, and could be even smaller using commonly available miniaturization technologies. Thus, several sensors could be placed on a surface such that a representative ice thickness profile could be measured. The benefits offered by developing this technology go beyond the safety improvements realized by monitoring ice formation on the wings of an aircraft. Continuous monitoring of anti-icing fluid concentrations on the ground would warn the pilot of impending fluid failure as well as allowing the stations to use less de-icing solution per aircraft. This in turn would increase the safety of takeoffs and reduce the overall discharge of de-icing solution into the environment, thus reducing the biohazard of the de-icing procedure.

Yao, Stephen S. C.

The continuous measurement of hydrogen chloride in the ambient atmosphere using the dual isotope infrared absorption technique

The results of a program to develop a prototype gas filter correlation NDIR analyzer capable of providing the required HCl measurement capability, while maintaining an adequate rejection of any other gases anticipated in the atmosphere are presented. Examples of the performance of the prototype analyzer are presented which show an rms noise equivalent concentration of 0.06 ppm of HCl was achieved while maintaining an electronically determined 10% to 90% time response to gas samples of about 2 seconds. No measureable response was observed to CO2, CO, and H2O while maintaining an adequate rejection of the hydrocarbons, for example CH4 and n-hexane. The experiments were performed which demonstrate that the span stability of the HCl gas filter correlation analyzer is unaffected by the presence of water vapor and which support the belief that the incorporation of a relatively open-volume, multiple path sample cell into the instrument would enable ground station as well as airborne measurements of trace quantities of HCl in the ambient atmosphere to be performed.

Williams, K. G.

Continuous measurement of nontidal variations of gravity

Records from seven superconducting gravimeters operated at five different locations in California and one in Boulder, CO, are examined after removal of tides and the gravitational attraction of the atmosphere. Fluctuations over periods between a few days and several months were observed at all sites with peak amplitudes of order 10 microgal. By contrast, a 640-day record obtained with one of the instruments in Germany showed peak fluctuations of only 2 microgal. In most of the records the causes of these aperiodic variations were not determined so that they serve to set limits on the vertical motion or displacement of mass at the respective locations. However, at The Geysers geothermal field, much of the gravity variation is correlated with seismic activity, reinjection rate, and rainfall. Measurements of this type were not possible prior to the development of the superconducting device. Consequently, these results provide the first evidence for the existence of gravity variations on the time scale and of the magnitude described here. Vertical crustal motion, motion related to seismic events, and hydrological phenomena can lead to variations on this scale. Unambiguous identification of causal relationships will require either special circumstances such as found at The Geysers or operation of the instruments in pairs.

Goodkind, John M.

Continuing Measurements of CO2 Crystals with a Hand-Held 35 GHz Radiometer

In order to increase our knowledge of the Martian polar caps, an improved understanding of the behavior of both frozen H2O and CO2 in different parts of the electromagnetic spectrum is needed. The thermal microwave part of the spectrum has received relatively little attention compared to the visible and infrared wavelengths. A simple experiment to measure the brightness temperature of frozen CO2 was first performed in the winter of 1998 using a 35 GHz radiometer. in experiments performed during the winter of 1999 and 2000, passive microwave radiation emanating from within layers of manufactured CO2 (dry ice) crystals was again measured with a 35 GHz handheld radiometer. Both large (0.8 cm) and small (0.3 cm) cylindrical-shaped dry ice pellets, at a temperature of 197 K (-76 C), were measured. A 1 sq m plate of aluminum sheet metal was positioned beneath the dry ice so that microwave emissions from the underlying soil layers would be minimized. Non-absorbing foam was positioned around the sides of the plate in order to keep the dry ice in place and to assure that the incremental deposits were level. Thirty-five GHz measurements of this plate were made through the dry ice deposits in the following way. Layers of dry ice were built up and measurements were repeated for the increasing CO2 pack. First, 7 cm of large CO2 pellets were poured onto the sheet metal plate, then an additional 7 cm were added, and finally, 12 cm were added on top of the 14 cm base. Hand-held 35 GHz measurements were made each time the thickness of the deposit was increased. The same process was repeated for the smaller grain pellets. Furthermore, during the past winter, 35 GHz measurements were taken of a 25 kg (27 cm x 27 cm x 27 cm) solid cube Of CO2, which was cut in half and then re-measured. Additional information is contained in the original extended abstract.

Foster, J.

Continuous Measurements and Quantitative Constraints: Challenge Problems for Discrete Modeling Techniques

We present some diagnosis and control problems that are difficult to solve with discrete or purely qualitative techniques. We analyze the nature of the problems, classify them and explain why they are frequently encountered in systems with closed loop control. This paper illustrates the problem with several examples drawn from industrial and aerospace applications and presents detailed information on one important application: In-Situ Resource Utilization (ISRU) on Mars. The model for an ISRU plant is analyzed showing where qualitative techniques are inadequate to identify certain failure modes and to maintain control of the system in degraded environments. We show why the solution to the problem will result in significantly more robust and reliable control systems. Finally, we illustrate requirements for a solution to the problem by means of examples.

Goodrich, Charles H.

Overview of NASA’s Science Mission Directorate Small Satellites Programs and Advances in Transformative Science Measurements with Small Satellites

Small satellites have become an accepted platform for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to support high spatial and temporal measurements, continuity measurements, and constellations in response to science objectives described in NASA’s Decadal Surveys. Across six divisions of the Science Mission Directorate (SMD), over 12 years, SMD has funded 88 CubeSat/ SmallSat Missions and 59 Studies to date. Currently, SMD has 53 small spacecraft science missions (87spacecraft) in implementation or formulation. This paper provides the background of efforts to promote the implementation of small satellites within NASA as a balanced portfolio for the agency’s science, technology, and exploration goals. We include analysis of SmallSat awards and trends funded by SMD through Research Opportunities in Space and Earth Sciences (ROSES), Small Innovative Missions for Planetary Exploration (SIMPLEx), and Small Explorer (SMEX) and Medium Explorer (MIDEX) calls over the last 12years. The data source of this assessment is a subset of the NASA SmallSat Coordination Group Database, a collection of all known funded NASA SmallSat and CubeSat missions and studies. This paper also provides an overview of small satellite programs and selected missions from SMD’s divisions: Astrophysics, Heliophysics, Earth Science, and Planetary Science, and describes SMD’s efforts in fostering an incremental and continuous path to achieve high-priority science through transformative science measurements. This paper recognizes the latest observations and trends of the NASA CubeSat / SmallSat Science missions with masses ranging between 1kg to 500kg.

Small Satellites, SMD SmallSat, CubeSat,