Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous glucose monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Effects of oral glucose on exercise thermoregulation in men after water immersion

To test the hypothesis elevated blood glucose would attenuate the rise in exercise rectal temperature, six men age 35 plus or minus S.D. 7 years participated in each of three trials by 4-hr water immersion to the neck: (1) 2.0 g/kg body wt of oral glucose (33.8 percent wt./vol.) was consumed followed by 80 min controlled rest (Glu/Rest), and 70 min horizontal supine cycle exercise at 62.8 percent plus or minus S.E. 0.5 percent (1.97 plus or minus 0.02 L/min) of peak O2 uptake followed by 10 min recovery (2) with (Glu/Ex) and (3) without prior flucose (No Glu/Ex). Blood samples were taken at -25, 0, 15, 45, and 68 min of exercise and after plus 10 min of recovery for measurement of hemoglobin, hematocrit, and blood glucose. Both mean skin (T sub sk) (from six sites) and rectal temperatures (T sub re) were monitored continuously. Sweat rate was measured by resistanc hygrometry. The mean of delta PV for the exercise trials was -12.2 plus or minus 2.1 percent. Mean blood glucose for the Glu/Ex trial was higher than that of the No Glu/Ex trial was (108.4 equal or minus 3.9 and 85.6 plus or minus 1.6 mg/dl, respectively, P less than 0.05. At the end of exercise T(sub sk) for the Glu/Ex trial was lower than for No Glu/Ex(32.0 plus or minus 0.3 and 32.4 equals or minus 0.2 C, respectively, P less than 0.05); T(sub re) for the Glu/Ex trial was lower than for No Glu/Es (38.22 plus or minus 0.17 and 38.60 plus or minus 0.11 C, respectively, P less than 0.05); and forearm sweat rate for the Glu/Ex trial (0.34 plus or minus 0.04 and 0.43 plus or minus g/sq cm, respectively, P less than 0.05). These data suggest that elevation of blood glucose prior to horizontal exercise following hypohydration attenuates the increase in body temperature without altering heat production or exercise hypovolemia.

Dearborn, Alan S.↗

Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts

Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.

Tohda, Koji↗

NASA Tech Briefs, October 2006

Topics covered include: Protein Sensors Based on Optical Ring Resonators; Phase Sensor for Aligning a Segmented Telescope Mirror; Control Software for Advanced Video Guidance Sensor; Generating Control Commands From Gestures Sensed by EMG; Multiple-Flat-Panel System Displays Multidimensional Data; 3D X-Ray Luggage-Screening System; Probe Station and Near-Field Scanner for Testing Antennas; Photodetector Arrays for Multicolor Visible/Infrared Imaging; Semiconductor Bolometers Give Background-Limited Performance; Multichannel X-Band Dielectric-Resonator Oscillator; Automatic Alignment of Displacement-Measuring Interferometer; Earth Observing System Data Gateway; Power User Interface; Mercury Shopping Cart Interface; Cassini Archive Tracking System; Architecture Adaptive Computing Environment; Computing Fault Displacements from Surface Deformations; Oxygen-Permeable, Hydrophobic Membranes of Silanized alpha-Al2O3; SiC Composite Turbine Vanes; Retaining Device for the Interior Structure of a Spacecraft Payload; Tool for Torquing Circular Electrical-Connector Collars; System for Continuous Deaeration of Hydraulic Oil; Solar-Powered Cooler and Heater for an Automobile Interior; Improved Oxygen-Beam Texturing of Glucose-Monitoring Optics; Tool for Two Types of Friction Stir Welding; Stationary Apparatus Would Apply Forces of Walking to Feet; Instrument Would Detect and Collect Biological Aerosols; Boundary Condition for Modeling Semiconductor Nanostructures; Miniature Distillation Column for Producing LOX From Air; Even Illumination from Fiber-Optic-Coupled Laser Diodes; Optically Driven Deformable Mirrors; Algorithm for Automated Detection of Edges of Clouds; Exploiting Quantum Resonance to Solve Combinatorial Problems; Hybrid Terrain Database; On Release of Microbe-Laden Particles from Mars Landers; A Concept for Run-Time Support of the Chapel Language; Thermoelectric Inhomogeneities in (Ag(sub 1-y)SbTe2)(sub x)(PbTe)(sub 1-x); and Spacecraft Escape Capsule.

Source record↗

Non-invasive optical detection of glucose in cell culture nutrient medium

The objective of the proposed research was to begin the development of a non-invasive optical sensor for measuring glucose concentration in the output medium of cell cultures grown in a unique NASA bioreactor referred to as an integrated rotating-wall vessel (IRWV). The input, a bovine serum based nutrient media, has a known glucose concentration. The cells within the bioreactor digest a portion of the glucose. Thus, the non-invasive optical sensor is needed to monitor the decrease in glucose due to cellular consumption since the critical parameters for sustained cellular productivity are glucose and pH. Previous glucose sensing techniques have used chemical reactions to quantify the glucose concentration. Chemical reactions, however, cannot provide for continuous, real time, non-invasive measurement as is required in this application. Our effort while in the fellowship program was focused on the design, optical setup, and testing of one bench top prototype non-invasive optical sensor using a mid-infrared absorption spectroscopy technique. Glucose has a fundamental vibrational absorption peak in the mid-infrared wavelength range at 9.6 micron. Preliminary absorption data using a CO2 laser were collected at this wavelength for water based glucose solutions at different concentrations and one bovine serum based nutrient medium (GTSF) with added glucose. The results showed near linear absorption responses for the glucose-in-water data with resolutions as high at 108 mg/dl and as low as 10 mg/dl. The nutrient medium had a resolution of 291 mg/dl. The variability of the results was due mainly to thermal and polarization drifts of the laser while the decrease in sensitivity to glucose in the nutrient medium was expected due to the increase in the number of confounders present in the nutrient medium. A multispectral approach needs to be used to compensate for these confounders. The CO2 laser used for these studies was wavelength tunable (9.2 to 10.8 micrometers), however, it was to unstable across wavelengths to test the multispectral approach. From this research, further NASA support was obtained to continue the work throughout the year in which a more stable light source will be used at smaller, near-infrared, wavelengths. It is anticipated that a more compact, non-invasive, optical glucose sensor will be realized which can be used with a bioreactor on future space shuttle missions. It is also anticipated that a multispectral optical sensor may be used to determine the concentration of other molecules needed within the NASA bioreactor, such as fructose and galactose.

Cote, Gerald L.↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

Novel Approaches to Cellular Transplantation from the US Space Program

Research in the treatment of type I diabetes is entering a new era that takes advantage of our knowledge in an ever increasing variety of scientific disciplines. Some may originate from very diverse sources, one of which is the Space Program at National Aeronautics and Space Administration (NASA). The Space Program contributes to diabetes-related research in several treatment modalities. As an ongoing effort for medical monitoring of personnel involved in space exploration activities NASA and the extramural scientific community investigate strategies for noninvasive estimation of blood glucose levels. Part of the effort in the space protein crystal growth program is high-resolution structural analysis insulin as a means to better understand the interaction with its receptor and with host immune components and as a basis for rational design of a "better" insulin molecule. The Space Program is also developing laser technology for potential early cataract detection as well as a noninvasive analyses for addressing preclinical diabetic retinopathy. Finally, NASA developed an exciting cell culture system that affords some unique advantages in the propagation and maintenance of mammalian cells in vitro. The cell culture system was originally designed to maintain cell suspensions with a minimum of hydrodynamic and mechanical sheer while awaiting launch into microgravity. Currently the commercially available NASA bioreactor (Synthecon, Inc., Houston, TX) is used as a research tool in basic and applied cell biology. In recent years there is continued strong interest in cellular transplantation as treatment for type I diabetes. The advantages are the potential for successful long-term amelioration and a minimum risk for morbidity in the event of rejection of the transplanted cells. The pathway to successful application of this strategy is accompanied by several substantial hurdles: (1) isolation and propagation of a suitable uniform donor cell population; (2) management of host immune rejection; (3) protection from the autoimmune component of the disease; and (4) anatomic placement of the engrafted cells that permits timely response to blood sugar levels as well as effective release and deployment of insulin. Bioreactor technology may provide some critical advances for surmounting some of these scientific hurdles. The NASA bioreactor is a horizontally rotating cylinder that is completely filled with culture medium. Gaseous exchange is maintained by a concentric cylinder of permeable silicon. In slow rotation (15-25 rpm) particles of small mass such as cells and tissue aggregates remain suspended in the rotating body of fluid. This novel approach suspends cells without stirring thus, allowing objects of different size mass to colocate and interact in a very low shear environment. In fact, analysis of the forces acting on individual cells in the rotating bioreactor reveals that the cells are continuously falling through the fluid medium. The conditions in the bioreactor permit assembly of cells into aggregates. three-dimensional tissue growth, synthesis of intercellular matrix,10 differentiation, and some sinusoid formations that may serve as a surrogate vasculature for larger tissue segments.

Pellis, Neal R.↗

Advanced sensor systems for biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 .mu.W., which yields a lifetime of approximately 6-9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38.times.28 mm to 22.times.8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗

Advanced Sensor Systems for Biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 microW, which yields a lifetime of approximately 6 - 9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38 x 28 mm to 22 x 8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗