Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous glucose monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring

Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. In this research, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a “watch strap”, electrochemical glucose sensors, customized circuits, and display units integrated into a “dial” platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO 2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.

47 OTHER INSTRUMENTATION↗

Open Humans: A platform for participant-centered research and personal data exploration

Background: Many aspects of our lives are now digitized and connected to the internet. As a result, individuals are now creating and collecting more personal data than ever before. This offers an unprecedented chance for human-participant research ranging from the social sciences to precision medicine. With this potential wealth of data comes practical problems (e.g., how to merge data streams from various sources), as well as ethical problems (e.g., how best to balance risks and benefits when enabling personal data sharing by individuals). Results: To begin to address these problems in real time, we present Open Humans, a community-based platform that enables personal data collections across data streams, giving individuals more personal data access and control of sharing authorizations, and enabling academic research as well as patient-led projects. We showcase data streams that Open Humans combines (e.g., personal genetic data, wearable activity monitors, GPS location records, and continuous glucose monitor data), along with use cases of how the data facilitate various projects. Conclusions: Open Humans highlights how a community-centric ecosystem can be used to aggregate personal data from various sources, as well as how these data can be used by academic and citizen scientists through practical, iterative approaches to sharing that strive to balance considerations with participant autonomy, inclusion, and privacy.

59 BASIC BIOLOGICAL SCIENCES↗

In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors

Background: Electrochemical enzymatic glucose sensors are intended to measure blood or interstitial fluid glucose concentrations. One class of these glucose sensors are continuous glucose monitors (CGMs), indicated for tracking and trending of glucose concentrations in interstitial fluid and as an adjunct to blood glucose testing. Currently approved CGMs employ a glucose oxidase (GOx) electrochemical detection scheme. Potential interfering agents can impact the accuracy of results obtained by glucose sensors, including CGMs. Methods: Seven sugars, seven sugar alcohols, and three artificial sweeteners were in vitro screened for interference with amperometric glucose oxidase (GOx) sensors at concentrations greater than physiologic concentrations. Galactose was investigated further at physiologically relevant concentrations using a custom amperometric system. Furthermore, glucose and galactose calibration experiments were conducted to facilitate multiple enzyme kinetic analysis approaches (Michaelis-Menten and Hill equation) to understand the potential source and mechanism of interference from galactose. Results: Under in vitro testing, except for galactose, xylose and mannose, all screened compounds exhibited interference bias, expressed in mean absolute relative difference (MARD), of ⩽ 20% even at concentrations significantly higher than normal physiologic concentrations. Galactose exhibited, CGM-dependent, MARD of 47-72% and was subjected to further testing. The highest recorded mean relative difference (MRD) was 6.9 ± 1.3% when testing physiologically relevant galactose concentrations (0.1-10 mg/dL). Enzyme kinetic analysis provided calculations of maximum reaction rates ([Formula: see text]), apparent Michaelis constants ([Formula: see text]), and Hill equation h parameters for glucose and galactose substrates for the enzymes in the CGMs. Conclusion: Under the conditions of in vitro screening, 14 of the 17 compounds did not exhibit measuarable interference. Galactose exhibited the highest interference during screening, but did not substantially interfere with CGMs under the conditions of in vitro testing at physiologically relevant concentrations. Enzyme kinetic analysis conducted with galactose supported the notion that (1) the reactivity of GOx enzyme toward nonglucose sugars and (2) the presence of enzymatic impurities (such as galactose oxidase) are two potential sources for sugar interference with GOx glucose sensors, and thus, should be considered during device development.

Boehm, Ryan↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

54 ENVIRONMENTAL SCIENCES↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

60 - APPLIED LIFE SCIENCES↗

Engineered Glucose Oxidase‐Carbon Nanotube Conjugates for Tissue‐Translatable Glucose Nanosensors

Abstract Continuous and non‐invasive glucose monitoring and imaging is important for disease diagnosis, treatment, and management. However, glucose monitoring remains a technical challenge owing to the dearth of tissue‐transparent glucose sensors. In this study, we present the development of near‐infrared fluorescent single‐walled carbon nanotube (SWCNT) based nanosensors directly functionalized with glucose oxidase (GOx) capable of immediate and reversible glucose imaging in biological fluids and tissues. We prepared GOx‐SWCNT nanosensors by facile sonication of SWCNT with GOx in a manner that—surprisingly—does not compromise the ability of GOx to detect glucose. Importantly, we find by using denatured GOx that the fluorescence modulation of GOx‐SWCNT is not associated with the catalytic oxidation of glucose but rather triggered by glucose‐GOx binding. Leveraging the unique response mechanism of GOx‐SWCNT nanosensors, we developed catalytically inactive apo‐GOx‐SWCNT that enables both sensitive and reversible glucose imaging, exhibiting a ΔF/F 0 of up to 40 % within 1 s of exposure to glucose without consuming the glucose analyte. We finally demonstrate the potential applicability of apo‐GOx‐SWCNT in biomedical applications by glucose quantification in human plasma and glucose imaging in mouse brain slices.

Chemistry↗

A Review of the Security of Insulin Pump Infusion Systems

Insulin therapy has enabled diabetic patients to maintain blood glucose control to lead healthier lives. Today, rather than manually injecting insulin using syringes, a patient can use a device, such as an insulin pump, to programmatically deliver insulin. This allows for more granular insulin delivery while attaining blood glucose control. The insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this paper we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components including the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but we also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues both for now and in the future.

59 BASIC BIOLOGICAL SCIENCES↗

Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

60 APPLIED LIFE SCIENCES↗

Capillary absorption spectroscopy for high temporal resolution measurements of stable carbon isotopes in soil and plant-based systems

Capillary Absorption Spectroscopy (CAS) is a relatively new analytical technique for performing stable isotope analysis. Here, we demonstrate the utility of CAS by recording and quantifying variation in 13C in controlled and biologically relevant applications. We calibrated CAS system response to increased 13CO2, with an observed ~4‰ increase in measured Δ13C for each 0.03 ppm shift in 13CO2 concentration. We leveraged this calibration to quantify rates of biogeochemical processes using a 13C tracer. For example, we monitored microbial respiration of 13C-glucose within an agricultural soil at 10 s quantification intervals and results demonstrated 8.6% ± 0.4 of added glucose was converted to 13CO2 within 1.5 h of incubation. We expanded the demonstration by adapting a rhizobox to permit continuous monitoring of 13CO2 in a soil (as distinct from plant) headspace to track the timing and quantify respiration rates of fresh plant photosynthate and observed a 3.5 h delay between plant exposure to a13CO2 tracer and the first signs of respiration by soil biota. These experiments highlight CAS is effective in producing high temporal resolution quantification of 13CO2 and demonstrate potential applications.

13CO2↗

Depth-resolved monitoring of diffusion of hyperosmotic agents in normal and malignant human esophagus tissues using optical coherence tomography in-vitro

Depth-resolved monitoring with differentiation and quantification of glucose diffusion in healthy and abnormal esophagus tissues has been studied in vitro. Experiments have been performed using human normal esophagus and esophageal squamous cell carcinoma (ESCC) tissues by the optical coherence tomography (OCT). The images have been continuously acquired for 120 min in the experiments, and the depth-resolved and average permeability coefficients of the 40 % glucose solution have been calculated by the OCT amplitude (OCTA) method. We demonstrate the capability of the OCT technique for depth-resolved monitoring, differentiation, and quantifying of glucose diffusion in normal esophagus and ESCC tissues. It is found that the permeability coefficients of the 40 % glucose solution are not uniform throughout the normal esophagus and ESCC tissues and increase from (3.30 {+-} 0.09) Multiplication-Sign 10{sup -6} and (1.57 {+-} 0.05) Multiplication-Sign 10{sup -5} cm s{sup -1} at the mucous membrane of normal esophagus and ESCC tissues to (1.82 {+-} 0.04) Multiplication-Sign 10{sup -5} and (3.53 {+-} 0.09) Multiplication-Sign 10{sup -5} cm s{sup -1} at the submucous layer approximately 742 {mu}m away from the epithelial surface of normal esophagus and ESCC tissues, respectively. (optical coherence tomography)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relating fish health and reproductive metrics to contaminant bioaccumulation at the Tennessee Valley Authority Kingston coal ash spill site

A 4.1 million m 3 release of coal ash into the Emory and Clinch rivers in December 2008 at Tennessee Valley Authority s Kingston Fossil Plant has prompted a long-term, large-scale biological monitoring effort to determine if there are chronic effects of this spill on biota. Of concern in this spill were arsenic (As) and selenium (Se), heavy metal constituents of coal ash that can be toxic to fish and wildlife and also mercury (Hg): a legacy contaminant that can interact with Se in organisms. We used fish filet bioaccumulation data from Bluegill Lepomis macrochirus, Redear Lepomis microlophus, Largemouth Bass Micropterus salmoides and Channel Catfish Ictalurus punctatus and metrics of fish health including fish condition indices, blood chemistry parameters and liver histopathology data collected from 2009-2013 to determine whether tissue heavy metal burdens relate 1) to each other 2) to metrics of fish health (e.g., blood chemistry characteristics and liver histopathology) and condition, and 3) whether relationships between fish health characteristics and heavy metals are related to site and ash-exposure. We found that burdens of Se and As are generally related to each other between tissues, but burdens of Hg between tissues are not generally positively associated. Taking analyses together, there appears to be reductions in growth and sublethal liver and kidney dysfunction in Bluegill and Largemouth Bass as indicated by blood chemistry parameters (elevated blood protein, glucose, phosphorous, blood urea nitrogen and creatinine in ash-affected sites) and related to concentrations of As and Se. Seeing sub-lethal effects in these species of fish is interesting because Redear had the highest filet burdens of Se, but did not have biomarkers indicating disease or dysfunction. We conclude our study by highlighting the complexities inherent in multimetric fish health data and the need for continued monitoring to further untangle contaminant and fish health associations.

54 ENVIRONMENTAL SCIENCES↗

Development and Fabrication of Nanoporous Silicon-based Bioreactors within a Microfluidic Chip

Multi-scale lithography and cryogenic deep reactive ion etching techniques were used to create ensembles of nanoporous, picoliter volume, reaction vessels within a microfluidic system. The fabrication of these vessels is described and how this process can be used to tailor vessel porosity by controlling the width of slits that constitute the vessel pores is demonstrated. Control of pore size allows the containment of nucleic acids and enzymes that are the foundation of biochemical reaction systems, while allowing smaller reaction constituents to traverse the container membrane and continuously supply the reaction. In this work, a 5.4kB DNA plasmid was retained within the reaction vessels and labeled under microfluidic control with ethidium bromide as an initial proof-of-principle. Subsequently, a coupled enzyme reaction, in which glucose oxidase and horseradish peroxidase were contained and fed with a substrate solution of glucose and Amplex Red to produce fluorescent Resorufin, was carried out under microfluidic control and monitored using fluorescent microscopy. The fabrication techniques presented are broadly applicable and can be adapted to produce devices in which a variety of high aspect ratio, nanoporous silicon structures can be integrated within a microfluidic network. The devices shown here are amenable to being scaled in number and organized to implement more complex reaction systems for applications in sensing and production of biologically based therapeutics as well as fundamental studies of biological reaction systems.

09 BIOMASS FUELS↗

Final Technical Report - Commercially Important Carbohydrate Diacids - Building Blocks from Renewable Carbohydrates

The primary objective of this project was to develop oxidation methods appropriate for the conversion of agriculturally derived simple sugars to their corresponding diacids (aldaric acids) for use as biobased chemical building blocks for new biodegradable polymers and other materials. Principal target diacids were D-glucaric, meso-xylaric, D-mannaric and L-arabinaric acid, each to be prepared by nitric acid oxidation of the naturally occurring precursor carbohydrates (monosaccharides) D-glucose, D-xylose, D-mannose and L-arabinose, respectively, all from hydrolysis of naturally abundant plant polysaccharides. These conversions were to be designed for scale up to a level suitable for transfer first to a pilot plant scale, and then to an industrial plant scale. The core of the project involved a comprehensive study of the title oxidation employing a computer controlled reactor. The plan of action involved defining experimental parameters to allow for control of the oxidations with considerable precision and reproducibility. The prototype oxidations were typically run using ca. 0.75 molar amounts of carbohydrate, with a goal of eventually doubling the reaction size when appropriate reaction parameters were established. During the course of the funding period for this grant, the fundamentals of reaction control were established for oxidation of D-glucose, a critical component of the project given the exothermic character of the reaction. The reactions were monitored using a reliable GC/MS protocol. The glucose to glucaric acid conversion represented the most important and potentially highest value conversion. During the grant period we were able to establish one workable system to carry out the glucose to glucaric acid conversion, but were not able to optimize the process or establish a protocol that was satisfactory for a scale up to a pilot plant scale. However, the work carried out showed the possibility that with appropriate innovation and continued effort, a prototype for a successful pilot plant scale operation might be possible. It was not possible to explore oxidations with the other simple sugars indicated during the time frame of this project. A graduate student, J. Brand, and an undergraduate student, B. O'Connor received partial support for research done on the project. A manuscript for publication entitled ANitric Acid Oxidation of D-Glucose to D-Glucaric Acid: Improved Process and Analytical Assessment@, is in preparation for submission to Industrial & Engineering Chemistry Research or Carbohydrate Research.

36 MATERIALS SCIENCE↗

Intratumoral Injection of Hypertonic Glucose in Treating Refractory Pneumothorax Caused by Microwave Ablation: a Preliminary Study

Purpose: The purpose of this technical report is to describe the technique of intratumoral injection of hypertonic glucose combined with low-negative pressure drainage to treat refractory pneumothorax (RP) after microwave ablation (MWA) of lung tumors. Materials and Methods: Between September 2016 and May 2018, four patients who developed RP after MWA of peripheral lung cancer were managed by a combined method, including intratumoral injection of hypertonic glucose and catheter drainage under low-negative pressure. Blood gas values were recorded and compared before the treatment and one-week posttreatment. All patients were followed up for at least one month to monitor the possible recurrence of pneumothorax by chest CT. Results: All patients were successfully treated. One patient received the intratumoral injection of hypertonic glucose twice, while the remaining three patients received a single injection. The technical success rate was 100%. Dyspnea related to RP was significantly relieved in all patients, and PaO{sub 2} and SaO{sub 2} values were higher than those measured before treatment. No patient suffered a recurrence of pneumothorax during the follow-up. Conclusion: The combined method of intratumoral injection of hypertonic glucose and continuous catheter drainage under low-negative pressure might be an effective method to manage RP caused by MWA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.

47 OTHER INSTRUMENTATION↗

Near-infrared fluorescence glucose sensing based on glucose/galactose-binding protein coupled to 651-Blue Oxazine

Highlights: •We showed that the NIR fluorophore, 651-Blue Oxazine, is solvatochromic (polarity sensitive). •Blue Oxazine was covalently attached to mutants of glucose/galactose-binding protein (GBP). •Fluorescence intensity of GBP-Blue Oxazine increased with addition of glucose. •Fluorescence from bead-immobilised GBP-Blue Oxazine was detectable through skin in vitro. •This shows proof-of-concept for non-invasive glucose sensing using GBP-Blue Oxazine. -- Abstract: Near-infrared (NIR) fluorescent dyes that are environmentally sensitive or solvatochromic are useful tools for protein labelling in in vivo biosensor applications such as glucose monitoring in diabetes since their spectral properties are mostly independent of tissue autofluorescence and light scattering, and they offer potential for non-invasive analyte sensing. We showed that the fluorophore 651-Blue Oxazine is polarity-sensitive, with a marked reduction in NIR fluorescence on increasing solvent polarity. Mutants of glucose/galactose-binding protein (GBP) used as the glucose receptor were site-specifically and covalently labelled with Blue Oxazine using click chemistry. Mutants H152C/A213R and H152C/A213R/L238S showed fluorescence increases of 15% and 21% on addition of saturating glucose concentrations and binding constants of 6 and 25 mM respectively. Fluorescence responses to glucose were preserved when GBP-Blue Oxazine was immobilised to agarose beads, and the beads were excited by NIR light through a mouse skin preparation studied in vitro. We conclude GBP-Blue Oxazine shows proof-of-concept as a non-invasive continuous glucose sensing system.

60 APPLIED LIFE SCIENCES↗