At least 19 records

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics↗

Non-reciprocal acoustoelectric microwave amplifiers with net gain and low noise in continuous operation

Abstract Piezoelectric acoustic devices that are integrated with semiconductors can leverage the acoustoelectric effect, allowing functionalities such as gain and isolation to be achieved in the acoustic domain. This could lead to performance improvements and miniaturization of radio-frequency electronic systems. However, acoustoelectric amplifiers that offer a large acoustic gain with low power consumption and noise figure at microwave frequencies in continuous operation have not yet been developed. Here we report non-reciprocal acoustoelectric amplifiers that are based on a three-layer heterostructure consisting of an indium gallium arsenide (In 0.53 Ga 0.47 As) semiconducting film, a lithium niobate (LiNbO 3 ) piezoelectric film, and a silicon substrate. The heterostructure can continuously generate 28.0 dB of acoustic gain (4.0 dB net radio-frequency gain) for 1 GHz phonons with an acoustic noise figure of 2.8 dB, while dissipating 40.5 mW of d.c. power. We also create a device with an acoustic gain of 37.0 dB (11.3 dB net gain) at 1 GHz with 19.6 mW of d.c. power dissipation and a non-reciprocal transmission of over 55 dB.

42 ENGINEERING↗

Over 8 hours of continuous operation of a free-electron laser driven by a laser-plasma accelerator

Since the emergence of laser-plasma accelerators (LPAs), substantial work has been dedicated to using LPAs to drive free-electron lasers (FELs) for a broad range of applications. Despite recent breakthroughs, which have proven the fundamental feasibility of operating FELs with an LPA source, stable FEL operation over multiple hours without operator input had yet to be achieved. In this work, we report significant improvements to the stability of a hundred terawatt laser system, resulting in successful demonstration of reliable, long-term operation of an LPA-driven FEL in the self-amplified spontaneous emission (SASE) regime at 420 nm. The LPA source delivered 100 MeV electron beams at 1 Hz with high stability over more than 10 h, enabling over 8 h of continuous FEL operation without operator input. The acquired data were subsequently used to investigate correlations between the measured undulator radiation and parameters of the drive laser, plasma source, and electron beam. The revealed connections between LPA and FEL performance gave important additional insights into ways to further improve and stabilize the system, thus demonstrating the capability of our setup to serve as a powerful platform for future studies of LPA-driven FEL operation. The one-of-a-kind integration of multiple stabilization concepts onto the LPA facility discussed in this manuscript yielded significant accelerator and light source improvements (with residual correlations suggesting even more is possible), which will positively impact LPA applications at large.

Kohrell, Finn [Lawrence Berkeley National Laborato↗

Ensuring continued operation of INSPIRE as a cornerstone of the HEP information infrastructure

The INSPIRE platform — the most widely-used discovery service specifically tailored to the needs of researchers in High Energy Physics (HEP) — has become a central component of the information infrastructure for the discipline. Despite this, INSPIRE's continued sustainability is frequently endangered by resource constraints, recently made more acute by the loss of support from historical funders changing their research priorities. If the European particle physics community wishes to ensure INSPIRE's long-term sustainability, the community should secure international support and ensure appropriate funding.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Tri‐Metallic Catalyst for Oxygen Evolution Reaction Enables Continuous Operation of Anion Exchange Membrane Electrolyzer at 1A cm −2 for Hundreds of Hours

Abstract Although numerous efforts are made to synthesize active electrocatalysts for green hydrogen production; catalyst stability, and facile synthesis to scale up the production are still challenging. Herein, the production of novel non‐PGM catalysts for the oxygen reduction reaction (OER) in an alkaline aqueous medium is reported, which is based on the synthesis of a trimetallic metal–organic framework (MOF) precursors. Fine‐tuning of the composition of the metal centers (Ni, Co, and Fe) shows a great effect on OER activity after the MOF undergoes dynamic chemical and structural transformations under OER conditions. In situ characterization reveals the origin of OER activity enhancement as metals’ oxidation state increases, inducing compressive mechanical strain on metal centers, enhancing the electronic conductivity through the formation of oxygen vacancies, and stronger metal–oxygen covalency. Catalysts are used in membrane electrode assembly (MEA) setup within an industrial full‐cell anion exchange membrane electrolyzer (AEMEC), showing a stable performance for 550 h without noticeable decay at 750 and 1000 mA cm −2 industrial level current densities.

Chemistry↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Benchmarking SARS CoV-2 Infection in the Workplace to Support Continuity of Operations

Objective: The COVID-19 pandemic jeopardizes continuity of operations of workplaces and the health and safety of workers. Exemplar workplace-related SARS-CoV-2 benchmarks are described and illustrated with empirical data. Methods: Benchmarks were collected over a 9-month period on a large workplace (N = 5500+). These ranged from quantitative indices associated with RT-qPCR targeted testing and random surveillance screening, surveillance for new variants of SARS-CoV-2, intensive contact tracing, case management, return to work procedures, to monitoring of antibody seropositive status. Results: Data and analyses substantiated effectiveness of interventions. This was evidenced in suppressed infection rates, rapid case identification and isolation, acceptance of the program by employees, documentation of presumptive immunity, and working relationships with senior management. Conclusions: These SARS-CoV-2 exemplar benchmarks provided an evidence-base for practice and contributed strategically to organizational decisions.

60 APPLIED LIFE SCIENCES↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Thin THz QCL active regions for improved continuous-wave operating temperature

We compare the performance of 10 and 5 μm thick metal–metal waveguide terahertz quantum-cascade laser ridges operating around 2.7 THz and based on a 4-well phonon depopulation active region design. Thanks to reduced heat dissipation and lower thermal resistance, the 5 μm thick material shows an 18 K increase in continuous wave operating temperature compared to the 10 μm material, despite a lower maximum pulsed-mode operating temperature and a larger input power density. A maximum continuous wave operating temperature of 129 K is achieved using the 5 μm thick material and a 15 μm wide ridge waveguide, which lased up to 155 K in the pulsed mode. The use of thin active regions is likely to become increasingly important to address the increasing input power density of emerging 2- and 3-well active region designs that show the highest pulsed operating temperatures.

47 OTHER INSTRUMENTATION↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Advancements in High-Q development for novel medium-velocity 644 MHz 5-cell elliptical superconducting RF cavities for continuous-wave operation in heavy-ion linacs

The Facility for Rare Isotope Beams is a world-leading center for experimental nuclear physics research, and relies on a first-in-kind superconducting RF driver linac to supply 400 kW beams of a uniquely large range of particles, from protons through the heaviest uranium ions. The FRIB400 project proposes to double the end energy of the current superconducting FRIB linac for the heaviest uranium ions from 200 MeV per nucleon (MeV/u) to 400 MeV/u, which equates to approximately 1 GeV for protons. The increased rare isotope production from higher-energy drive beams would deliver new and exciting capabilities to FRIB users, which include extending the facility's reach along the neutron drip-line, greatly increasing the facility's rare isotope yield, and significantly improving the precision of parameter measurements for the nuclear matter equation of state, which is a particularly timely complement to the recent advent of multi-messenger astronomy, and the study of neutron star mergers. The unique set of design parameters defined by the 400 MeV/u (uranium) energy goal, the physical size, continuous-wave operation, and cryogenic capacity of the extant facilities at FRIB, requires development of a first-in-kind beta = v/c = 0.65, 644 MHz 5-cell elliptical superconducting RF (SRF) cavity, with field-leading efficiency, measured by the cavity's intrinsic quality factor, Q_0. The field of SRF has recently experienced a very active period of development, which demonstrated the potential to raise the Q_0 of 1.3 GHz cavities by factors of two to three or more. In addition to uncovering fascinating new properties of the fundamental physics of superconducting RF phenomena, these improvements suggest substantial improvements could be made over the minimum Q_0 of the proposed FRIB400 upgrade SRF cavities, if these new techniques can be adapted to the beta = 0.65, 644 MHz regime. This work presents the first validation of the the novel beta = 0.65, 644 MHz 5-cell elliptical superconducting RF cavity design, and the first results of both conventional and advanced RF surface preparation techniques. In particular, this work focuses on two recently-developed high-Q_0 recipes: N-doping, and furnace baking, setting the current world-record Q_0 for this type of resonant cavity at 3.8 x 10^10 at the FRIB400 operating gradient of 17.5 MV/m. We also find evidence that these results may be further improved upon, and make the case for further RF surface preparation recipe optimization. We then pair these high-power RF investigations with techniques borrowed from material science to try to better understand the ways in which specific properties of the niobium material, such as grain structure and superconducting flux pinning force, can be related to its superconducting RF performance. These experiments better elucidate the effects of high-temperature annealing on niobium samples, which suggest methods of further optimizing cavity flux expulsion and thus SRF performance.Read

McGee, Kellen E.↗

Switching from batch to continuous granulation: A case study of metoprolol succinate ER tablets

Continuous manufacturing (CM) has been used to produce several immediate release drug products. No extended-release (ER) product manufactured employing CM technology has been approved yet. Herein this study investigated the critical aspects of switching from the batch mode of high shear granulation to the continuous operation of twin-screw granulation for extended-release tablets. Metoprolol succinate ER tablets was used as a model ER formulation for this purpose. A central composite design (CCD) was employed to determine the effects of high shear granulator (HSG) parameters, namely impeller speed, granulation time, and binder liquid feeding rate, on the critical granulation characteristics important for product performance. These critical granulation characteristics served as a guide for switching from the batch processing to the continuous operation for achieving the same breaking strength and dissolution for this ER metoprolol tablets. The granulation time was the most critical factor affecting the bulk properties of granules which contributed to tablet dissolution. The higher density and lower compressibility of granules were attained at the longest granulation time of 5.4 min with the fastest liquid feeding rate of 75 g/min. The granules’ density was the primary factor negatively affecting the dissolution of metoprolol tablets. However, the breaking strength of tablets confounded the effect of granules density on metoprolol dissolution. Switching the processing parameters of high shear granulation to twin-screw granulation achieved similar dissolution profiles (F2 greater than 50). The screw speed was not found to affect bulk properties of granules. The root cause of granulation failures in twin-screw granulation, such as premature consolidation, excessive swelling, poor cohesion, inconsistent shearing effects, and formation of deformed agglomerates, were identified. In conclusion, the use of critical granulation characteristics through a performance-based approach of ER tablets facilitated the switching of manufacturing of an ER formulation form batch to continuous operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning nonlinear operators via DeepONet based on the universal approximation theorem of operators

It is widely known that neural networks (NNs) are universal approximators of continuous functions. However, a less known but powerful result is that a NN with a single hidden layer can accurately approximate any nonlinear continuous operator. This universal approximation theorem of operators is suggestive of the structure and potential of deep neural networks (DNNs) in learning continuous operators or complex systems from streams of scattered data. Here, in this work, we thus extend this theorem to DNNs. We design a new network with small generalization error, the deep operator network (DeepONet), which consists of a DNN for encoding the discrete input function space (branch net) and another DNN for encoding the domain of the output functions (trunk net). We demonstrate that DeepONet can learn various explicit operators, such as integrals and fractional Laplacians, as well as implicit operators that represent deterministic and stochastic differential equations. We study different formulations of the input function space and its effect on the generalization error for 16 different diverse applications.

97 MATHEMATICS AND COMPUTING↗

CST R9120-B 30x60 Media Pretreatment and Digestion Standard Development to Support Tank Closure Cesium Removal 1A (TCCR-1A) Operations

In support of continued operations of Savannah River Remediation’s (SRR) ion exchange process to remove radioactive cesium from Savannah River Site (SRS) dissolved saltcake, referred to as the Tank Closure Cesium Removal 1A process (TCCR-1A; containing the second set of at-tank ion exchange columns), SRNL was tasked with: 1) validating the field protocol planned for pretreating the crystalline silicotitanate (CST) ion exchange media to be used in the columns, 2) preparing CST media for use in in-tank batch contact testing, and 3) developing a digestion standard to verify complete CST dissolution prior to characterization following each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed previously in support of the TCCR Demonstration (which contained the first set of ion exchange columns) based on evaluations of a different CST production lot with a larger particle size range to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗