Enhanced-Contrast Viewing of White-Hot Objects in Furnaces

An apparatus denoted a laser image contrast enhancement system (LICES) increases the contrast with which one can view a target glowing with blackbody radiation (a white-hot object) against a background of blackbody radiation in a furnace at a temperature as high as approximately 1,500 C. The apparatus utilizes a combination of narrowband illumination, along with band-pass filtering and polarization filtering to pass illumination reflected by the target while suppressing blackbody light from both the object and its background.

Witherow, William K.↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

The use of photographic methods in contrast enhancement of ERTS-1 images

The contrast of ERTS 70mm positive images can be enhanced to varying degrees by rephotographing the images with different types of negative films, and by overdeveloping the films with different developers. A combination of high contrast copy film (Kodak 5069) and a high energy developer (Kodak D-11) yields high contrast. Still greater contrast may be otbained by using a film of higher contrast capability and a developer of higher energy capability. Contrast can also be enhanced in the printing process with the use of highcontrast photographic papers, or with the use of polycontrast photographic paper and filters. Contrast enhancement by photocopying delineates topographic boundaries and may aid in the objective measurement of topographic parameters.

Harris, L. F.↗

Contrast enhancement of transparencies

System can enhance or reduce contrast of photographic transparency for printing or projection by using constructive and destructive interference of collimated laser beam. System is potentially less expensive than electronic CRT methods and is more accurate than trial-and-error manual techniques.

Shulman, A. R.↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

Efficient laser-driven proton acceleration from a petawatt contrast-enhanced second harmonic mixed-glass laser system

Efficient laser-driven plasma acceleration of ion beams requires precision control of the target–plasma profile, which is crucial to optimize the laser energy transfer. Along the laser propagation direction, this can be achieved by tailoring the temporal structure of the laser pulse. We show for the first time that frequency-doubling of a short pulse (hundreds-femtosecond range) petawatt-class mixed-glass laser system, which results in temporal intensity contrast enhancement, enables surface and volumetric laser–energy coupling, and the acceleration of proton beams from few-nanometer-thick foil targets. Experimentally, maximum ion energies and laser-to-proton energy conversion efficiencies were found to be both maximized at optimum laser and target conditions manifested when the normalized target density nearly equalizes the normalized laser vector potential, which is in agreement with theory and simulations. These signatures are recognized as a unique indication of the interaction between ultra-intense laser pulses with high temporal intensity contrast and ultra-thin nanometer-scale targets. Transverse modulations of accelerated proton beams in the form of bubble- and ring-like structures measured in the thinnest targets provide additional evidence of volumetric laser-driven particle acceleration regimes and transitional features in ultra-thin foil targets specific to laser–plasma interactions characterized by a high temporal intensity contrast. These results open avenues in the generation of high contrast laser pulses from short-pulse-femtosecond petawatt mixed-glass laser systems and demonstrate the feasibility of this technique for applications requiring high laser intensity contrast with high efficiency.

Physics↗

Laser Image Contrast Enhancement System

An optical image enhancement system provides improved image contrast in imaging of a target in high temperature surroundings such as a furnace. The optical system includes a source of vertically polarized light such as laser and a beam splitter for receiving the light and directing the light toward the target. A retardation plate is affixed to a target-facing surface of the beam splitter and a vertical polarizer is disposed along a common optical path with the beam splitter between the retardation plate and the target. A horizontal polarizer disposed in the common optical path, receives light passing through a surface of the beam splitter opposed to the target-facing surface. An image detector is disposed at one end of the optical path. A band pass filter having a band pass filter characteristic matching the frequency of the vertically polarized light source is disposed in the path between the horizontal polarizer and the image detector. The use of circular polarization, together with cross polarizers, enables the reflected light to be passed to the detector while blocking thermal radiation.

Robert L Kurtz↗

Photographic contrast enhancement of Landsat imagery

The effect of increased contrast of Landsat imagery is to stretch the informational content over a much greater density range. This results in greater density differences among scene features and provides a more interpretable image. The stretch required for MSS 5 and 7 is in the gamma range of 1.5 to 3.0. Several different film types, developers, and development times were used to reprocess Landsat images in a range of gammas from 1.0 to above 4.0. The gamma value to which the imagery was processed depended on the densitometric range of scene features in the image relative to the gray scale. An example of a photographically enhanced MSS 4 image is shown, in which the standard 0.94 density units was increased to 2.19 density units. The results are similar to those obtained in a computerized contrast stretch of digital CCT data, but are obtained at a far lesser cost.

Best, R. G.↗

Characterization of flowing liquid films as a regenerating plasma mirror for high repetition-rate laser contrast enhancement

In this paper, we characterize a high repetition-rate regenerating plasma mirror produced by the thin film of liquid formed when two laminar streams collide. The use of a flowing liquid film is inexpensive and the interaction surface refreshes automatically, avoiding buildup of on-target debris. The composition of the liquid material and the relative angle of the film-generating nozzles was optimized for this application. Spectra measured in reflection from a water-based plasma mirror showed a blue shift but an optical reflectivity of up to 30%. The thickness of the film was found to be of the order of 2 μm, and the stability of the reflected spot was ≈1 mrad. The reflected beam profile was highly distorted but stable. Further optimization of the nozzles to affect the fluid flow should enable significant improvements in control of the fluid films and increase in the reflectivity of these mirrors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Z-Contrast Enhancement in Au–Pt Nanocatalysts by Correlative X-ray Absorption Spectroscopy and Electron Microscopy: Implications for Composition Determination

The properties of bimetallic nanoparticles (BNPs) vary widely as a function of their composition and size distributions. X-ray absorption fine structure analysis is commonly used to characterize their structure, but its application to elements that are close to each other in the periodic table is hampered by poor Z-contrast. For this study, we trained an artificial neural network to recognize the partial coordination numbers in AuPt NPs synthesized via peptide templating using their X-ray absorption near-edge structure spectra. This approach, combined with scanning transmission electron microscopy analysis, revealed unique details of this prototype catalytic system that has different forms of heterogeneities at both the intra- and inter-particle levels. Our method based on the enhancement of Z-contrast of metal species will have implications for compositional studies of BNPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

Contrast enhanced spectroscopic optical coherence tomography

A method of forming an image of a sample includes performing SOCT on a sample. The sample may include a contrast agent, which may include an absorbing agent and/or a scattering agent. A method of forming an image of tissue may include selecting a contrast agent, delivering the contrast agent to the tissue, acquiring SOCT data from the tissue, and converting the SOCT data into an image. The contributions to the SOCT data of an absorbing agent and a scattering agent in a sample may be quantified separately.

Boppart, Stephen A.↗

Rational Control of Off‐State Heterogeneity in a Photoswitchable Fluorescent Protein Provides Switching Contrast Enhancement**

Abstract Reversibly photoswitchable fluorescent proteins are essential markers for advanced biological imaging, and optimization of their photophysical properties underlies improved performance and novel applications. Here we establish a link between photoswitching contrast, one of the key parameters that dictate the achievable resolution in nanoscopy applications, and chromophore conformation in the non‐fluorescent state of rsEGFP2, a widely employed label in REversible Saturable OpticaL Fluorescence Transitions (RESOLFT) microscopy. Upon illumination, the cis chromophore of rsEGFP2 isomerizes to two distinct off ‐state conformations, trans1 and trans2 , located on either side of the V151 side chain. Reducing or enlarging the side chain at this position (V151A and V151L variants) leads to single off ‐state conformations that exhibit higher and lower switching contrast, respectively, compared to the rsEGFP2 parent. The combination of structural information obtained by serial femtosecond crystallography with high‐level quantum chemical calculations and with spectroscopic and photophysical data determined in vitro suggests that the changes in switching contrast arise from blue‐ and red‐shifts of the absorption bands associated to trans1 and trans2 , respectively. Thus, due to elimination of trans2 , the V151A variants of rsEGFP2 and its superfolding variant rsFolder2 display a more than two‐fold higher switching contrast than their respective parent proteins, both in vitro and in E. coli cells. The application of the rsFolder2‐V151A variant is demonstrated in RESOLFT nanoscopy. Our study rationalizes the connection between structural and photophysical chromophore properties and suggests a means to rationally improve fluorescent proteins for nanoscopy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preoperative Radiomic Approach to Evaluate Tumor-Infiltrating CD8{sup +} T Cells in Hepatocellular Carcinoma Patients Using Contrast-Enhanced Computed Tomography

Background: To help identify potential hepatocellular carcinoma (HCC) candidates for immunotherapies, we aimed to develop and validate a radiomics-based biomarker (Rad score) to predict the infiltration of tumor-infiltrating CD8{sup +} T cells in HCC patients, and to evaluate the correlation of Rad score with tumor immune characteristics. Methods: Overall, 142 HCC patients (n = 100 and n = 42 in the training and validation sets, respectively) were subjected to radiomic feature extraction. Imaging features and immunochemistry data of patients in the training set were subjected to elastic-net regularized regression analysis to predict the level of CD8{sup +} T cell infiltration. Results: A Rad score for CD8{sup +} T-cell infiltration, which contained seven variables, was developed and was validated in the validation set (area under the curve [AUC]: training set 0.751, 95% confidence interval [CI] 0.656–0.846; validation set 0.705, 95% CI 0.547–0.863). The decision curve indicated the clinical usefulness of the Rad score. A higher Rad score correlated with superior overall and disease-free survival outcomes (p = 0.012 and 0.0088, respectively). Using the pathological slides, we found that the Rad score positively correlated with the percentage of tumor-infiltrating lymphocytes (TILs; Spearman rho = 0.51, p < 0.0001). Moreover, the Rad score could also discriminate inflamed tumors from immune-desert and immune-excluded tumors (Kruskal–Wallis, p < 0.0001), and higher Rad scores could be found in patients with positive programmed cell death ligand 1 expression in tumor/immune cells, as well as those with positive programmed cell death protein 1 expression. Conclusion: The newly developed Rad score was a powerful predictor of CD8{sup +} T-cell infiltration, which could be useful in identifying potential HCC patients who can benefit from immunotherapies when validated in large-scale prospective cohorts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗